Reda Čerapaitė-Trušinskienė
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Reda Čerapaitė-Trušinskienė has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Arvaidas Galdikas
Physics Department, Kaunas University of Technology, Studentu 50, LT-51368 Kaunas, Lithuania
2 shared publications - Diana Adliene
Department of Physics, Kaunas University of Technology, Studentų str. 50, 51368 Kaunas, Lithuania
2 shared publications - Diana Meilutytė-Lukauskienė
Department of Physics, Mathematics and Biophysics, Lithuanian University of Health Sciences, Kaunas, Lithuania
2 shared publications - Andrius Macas
Department of Anesthesiology, Faculty of Medicine, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
1 shared publication Egle Jonaitiene
1 shared publicationGediminas Adlys
1 shared publication
Latest Publications
- Open Access
- 5 March 2026
- Published by Oxford University Press (OUP) in European Heart Journal Open
- Vol. 6 (2)
Prognostic utility of Killip classification in acute myocardial infarction: a retrospective cohort analysis in contemporary clinical practice
Aims: The Killip classification is a long-established bedside tool for early haemodynamic risk stratification in ST-elevation myocardial infarction (STEMI). However, its prognostic performance in contemporary STEMI populations treated with primary percutaneous coronary intervention (PCI) remains debated. We aimed to re-evaluate the association between Killip class and in-hospital mortality in a modern STEMI cohort. Methods and results: We conducted a retrospective cohort study including 288 consecutive adults admitted with confirmed STEMI to the Hospital of the Lithuanian University of Health Sciences, Kaunas Clinics, between 1 January 2018 and 31 December 2021. STEMI was diagnosed according to the Fourth Universal Definition of Myocardial Infarction and ESC guidelines. The primary endpoint was in-hospital all-cause mortality. Independent predictors were identified using multivariable logistic regression. Model discrimination was assessed using receiver operating characteristic (ROC) analysis. Overall, in-hospital mortality was 18.2% (52/286 evaluable patients). Mortality increased substantially across Killip classes, from 1.0% in Class I and 3.0% in Class II to 69.6% in Class IV (P < 0.001). In multivariable analysis, Killip Class IV remained an independent predictor of in-hospital mortality (OR 60.94, 95%: CI 15.98–232.46; P < 0.001), together with age, body mass index, troponin level, and asystole. The final model demonstrated excellent discrimination (AUC 0.969, 95% CI: 0.945–0.992). Conclusion: In this temporary STEMI cohort, Killip Class IV was strongly and independently associated with in-hospital mortality. Although lower Killip classes showed limited prognostic separation, the Killip classification remains a rapid and clinically accessible tool for early risk assessment, particularly in haemodynamically unstable patients.
- 5 March 2026
- Published by Oxford University Press (OUP) in European Heart Journal Open
- Vol. 6 (2)
Open AccessPrognostic utility of Killip classification in acute myocardial infarction: a retrospective cohort analysis in contemporary clinical practice
Aims: The Killip classification is a long-established bedside tool for early haemodynamic risk stratification in ST-elevation myocardial infarction (STEMI). However, its prognostic performance in contemporary STEMI populations treated with primary percutaneous coronary intervention (PCI) remains debated. We aimed to re-evaluate the association between Killip class and in-hospital mortality in a modern STEMI cohort. Methods and results: We conducted a retrospective cohort study including 288 consecutive adults admitted with confirmed STEMI to the Hospital of the Lithuanian University of Health Sciences, Kaunas Clinics, between 1 January 2018 and 31 December 2021. STEMI was diagnosed according to the Fourth Universal Definition of Myocardial Infarction and ESC guidelines. The primary endpoint was in-hospital all-cause mortality. Independent predictors were identified using multivariable logistic regression. Model discrimination was assessed using receiver operating characteristic (ROC) analysis. Overall, in-hospital mortality was 18.2% (52/286 evaluable patients). Mortality increased substantially across Killip classes, from 1.0% in Class I and 3.0% in Class II to 69.6% in Class IV (P < 0.001). In multivariable analysis, Killip Class IV remained an independent predictor of in-hospital mortality (OR 60.94, 95%: CI 15.98–232.46; P < 0.001), together with age, body mass index, troponin level, and asystole. The final model demonstrated excellent discrimination (AUC 0.969, 95% CI: 0.945–0.992). Conclusion: In this temporary STEMI cohort, Killip Class IV was strongly and independently associated with in-hospital mortality. Although lower Killip classes showed limited prognostic separation, the Killip classification remains a rapid and clinically accessible tool for early risk assessment, particularly in haemodynamically unstable patients.
- Open Access
Modeling of Plasma Nitriding of Austenitic Stainless Steel through a Mask
In this work, 2D simulations of stainless steel nitriding through a mask were performed with two configurations: with and without lateral adsorption under the mask, depending on the strength of the mask adhesion. The stress-induced diffusion and trapping–detrapping process are included as the main mechanisms of nitrogen mass transport. The main focus is on the analysis of the swelling process, which affects the expansion of the material. The surface concentration profiles and topographical profiles along the surface are calculated and compared with experimentally registered ones taken from the literature, and they show a good agreement. This allows for estimation of the values of model parameters. Because nitriding processes takes place in vertical and horizontal directions, the anisotropic aspect of nitriding are analyzed. It is shown that the adherence of the mask significantly influences the topographical profile and the anisotropy of nitriding, because in the case of a weakly adhered mask, a lateral adsorption process takes place under the mask. The influence of swelling and anisotropy in the case of pattern nitriding in small dimensions is discussed.
Open AccessModeling of Plasma Nitriding of Austenitic Stainless Steel through a Mask
In this work, 2D simulations of stainless steel nitriding through a mask were performed with two configurations: with and without lateral adsorption under the mask, depending on the strength of the mask adhesion. The stress-induced diffusion and trapping–detrapping process are included as the main mechanisms of nitrogen mass transport. The main focus is on the analysis of the swelling process, which affects the expansion of the material. The surface concentration profiles and topographical profiles along the surface are calculated and compared with experimentally registered ones taken from the literature, and they show a good agreement. This allows for estimation of the values of model parameters. Because nitriding processes takes place in vertical and horizontal directions, the anisotropic aspect of nitriding are analyzed. It is shown that the adherence of the mask significantly influences the topographical profile and the anisotropy of nitriding, because in the case of a weakly adhered mask, a lateral adsorption process takes place under the mask. The influence of swelling and anisotropy in the case of pattern nitriding in small dimensions is discussed.
- Open Access
- 1 January 2024
- Published by Taras Shevchenko National University of Kyiv in Medical physics – the current status, problems, the way of development. Innovation technologies
- No. 1,p. 335-343
SECONDARY CANCER RISK ASSESSMENT OF PELVIC CONE BEAM COMPUTED TOMOGRAPHY IMAGING PROTOCOLS
Introduction. This study evaluates the secondary cancer risks associated with low-dose ionizing radiation from pelvic cone beam computed tomography (CBCT) imaging protocols in the context of image-guided radiotherapy (IGRT). Methods. The research identifies that effective dose varies significantly with protocol choice and field size; larger fields result in higher doses, emphasizing the need for optimization to balance diagnostic accuracy with safety. Results. Protocols such as Pelvis Fast, characterized by reduced default mAs and shorter scan times, demonstrate substantially lower effective doses compared to alternatives like Pelvis Large, translating to a decreased excess absolute risk (EAR) for secondary cancer development. Utilizing the BEIR VII model for risk assessment, the study underscores the importance of selecting imaging protocols with lower EAR values to mitigate secondary cancer risks effectively. Conclutions. These findings highlight the critical role of protocol selection in reducing radiation exposure while maintaining high image quality, providing valuable guidance for enhancing patient safety in medical imaging practices.
- 1 January 2024
- Published by Taras Shevchenko National University of Kyiv in Medical physics – the current status, problems, the way of development. Innovation technologies
- No. 1,p. 335-343
Open AccessSECONDARY CANCER RISK ASSESSMENT OF PELVIC CONE BEAM COMPUTED TOMOGRAPHY IMAGING PROTOCOLS
Introduction. This study evaluates the secondary cancer risks associated with low-dose ionizing radiation from pelvic cone beam computed tomography (CBCT) imaging protocols in the context of image-guided radiotherapy (IGRT). Methods. The research identifies that effective dose varies significantly with protocol choice and field size; larger fields result in higher doses, emphasizing the need for optimization to balance diagnostic accuracy with safety. Results. Protocols such as Pelvis Fast, characterized by reduced default mAs and shorter scan times, demonstrate substantially lower effective doses compared to alternatives like Pelvis Large, translating to a decreased excess absolute risk (EAR) for secondary cancer development. Utilizing the BEIR VII model for risk assessment, the study underscores the importance of selecting imaging protocols with lower EAR values to mitigate secondary cancer risks effectively. Conclutions. These findings highlight the critical role of protocol selection in reducing radiation exposure while maintaining high image quality, providing valuable guidance for enhancing patient safety in medical imaging practices.
- 1 December 2008
- Published by Elsevier in Applied Surface Science
- Vol. 255 (5) , 1929-1933
Real-time kinetic modeling of YSZ thin film roughness deposited by e-beam evaporation technique
- 1 December 2008
- Published by Elsevier in Applied Surface Science
- Vol. 255 (5) , 1929-1933
Real-time kinetic modeling of YSZ thin film roughness deposited by e-beam evaporation technique
- 1 January 2008
- Published by Lithuanian Academy of Sciences in Lithuanian Journal of Physics
- Vol. 48 (4) , 333-339
Non-monotonous dependences of thin film surface roughness on substrate temperature and deposited atom flux
- 1 January 2008
- Published by Lithuanian Academy of Sciences in Lithuanian Journal of Physics
- Vol. 48 (4) , 333-339
Non-monotonous dependences of thin film surface roughness on substrate temperature and deposited atom flux
- 17 May 2005
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 114 (1-3) , 399-402
Optimisation of X-ray examinations in Lithuania: start of implementation in mammography
Optimisation of medical X-ray examinations is very important for the enhancement of the reliability of the examination and for the reduction of the radiation dose to patients. Results of investigations of doses to patients during mammography using thermoluminescence dosemeters at different hospitals are presented together with a brief overview of the situation for mammography in Lithuania. It is shown that the entrance surface air kerma varies in a broad range and differed from hospital to hospital. Nevertheless the calculated values of average glandular dose (AGD) for a ‘standard’ breast being relatively high were comparable with those (3.2 mGy per exposure at net optical density 1.4) currently accepted by international authorities. Differences in AGD values evaluated at different hospitals demonstrate the existing potential for optimisation of the mammography screening procedures. The results of this investigation will be included in a database for patient doses in Lithuania and used for establishing a national reference dose level for mammography. Currently, reference levels recommended by international authorities are used in Lithuania.
- 17 May 2005
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 114 (1-3) , 399-402
Optimisation of X-ray examinations in Lithuania: start of implementation in mammography
Optimisation of medical X-ray examinations is very important for the enhancement of the reliability of the examination and for the reduction of the radiation dose to patients. Results of investigations of doses to patients during mammography using thermoluminescence dosemeters at different hospitals are presented together with a brief overview of the situation for mammography in Lithuania. It is shown that the entrance surface air kerma varies in a broad range and differed from hospital to hospital. Nevertheless the calculated values of average glandular dose (AGD) for a ‘standard’ breast being relatively high were comparable with those (3.2 mGy per exposure at net optical density 1.4) currently accepted by international authorities. Differences in AGD values evaluated at different hospitals demonstrate the existing potential for optimisation of the mammography screening procedures. The results of this investigation will be included in a database for patient doses in Lithuania and used for establishing a national reference dose level for mammography. Currently, reference levels recommended by international authorities are used in Lithuania.