Priya Ranjan Muduli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Priya Ranjan Muduli has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Vinit Kumar
Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, India
8 shared publications - Anirban Mukherjee
Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, West Bengal, India
6 shared publications - Naragoni Saidulu
Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, India
6 shared publications Umesh Chandra Pati
Department of Electronics and Communication Engineering, National Institute of Technology, Rourkela-769008, India
3 shared publications- Anirban Dasgupta
Department of Electronics and Electrical Engineering, Indian Institute of Technology Guwahati, Guwahati, India
2 shared publications - Atul Kumar
Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, India
2 shared publications
Latest Publications
- Open Access
Development and Preliminary Evaluation of an Electric Kick-Scooter Platform with BLDC Drive Control, Battery Voltage–Current Logging, and Rider-Mass-Based Theoretical Range Estimation
Electric kick scooters are becoming popular for short-distance applications on campuses, in industrial facilities and in gated communities, but their electrical demand and integrated low-cost operational functions are not fully addressed. A 350 W brushless direct-current hub motor, a 36 V, 4.4 Ah lithium-ion battery pack and a Hall-sensor-based controller with 120° six-step trapezoidal commutation were developed. A battery voltage–current data logger, a preliminary rider-mass-based theoretical range-estimation approach and a mobile application prototype were also developed. The gate states and phase-terminal voltage responses were simulated in MATLAB/Simulink R2021b, while preliminary hardware testing confirmed motor operation. The maximum observed motor speed was 1753 rpm, and the minimum was 1632 rpm. During partial charging and load-based discharging, the battery voltage and current were recorded by the data logger. Average currents of 3.88, 7.40 and 8.30 A were recorded in three pilot trials involving rider masses of 60, 80 and 140 kg, respectively. Assuming nominal battery energy and an average speed of 15 km/h, the corresponding theoretical ranges were calculated as 17.01, 8.92 and 7.95 km. These results demonstrate battery voltage–current acquisition by the data logger and provide descriptive pilot observations across the rider-mass cases; they do not establish a validated predictive or causal relationship between rider mass and actual scooter range.
Open AccessDevelopment and Preliminary Evaluation of an Electric Kick-Scooter Platform with BLDC Drive Control, Battery Voltage–Current Logging, and Rider-Mass-Based Theoretical Range Estimation
Electric kick scooters are becoming popular for short-distance applications on campuses, in industrial facilities and in gated communities, but their electrical demand and integrated low-cost operational functions are not fully addressed. A 350 W brushless direct-current hub motor, a 36 V, 4.4 Ah lithium-ion battery pack and a Hall-sensor-based controller with 120° six-step trapezoidal commutation were developed. A battery voltage–current data logger, a preliminary rider-mass-based theoretical range-estimation approach and a mobile application prototype were also developed. The gate states and phase-terminal voltage responses were simulated in MATLAB/Simulink R2021b, while preliminary hardware testing confirmed motor operation. The maximum observed motor speed was 1753 rpm, and the minimum was 1632 rpm. During partial charging and load-based discharging, the battery voltage and current were recorded by the data logger. Average currents of 3.88, 7.40 and 8.30 A were recorded in three pilot trials involving rider masses of 60, 80 and 140 kg, respectively. Assuming nominal battery energy and an average speed of 15 km/h, the corresponding theoretical ranges were calculated as 17.01, 8.92 and 7.95 km. These results demonstrate battery voltage–current acquisition by the data logger and provide descriptive pilot observations across the rider-mass cases; they do not establish a validated predictive or causal relationship between rider mass and actual scooter range.
- 9 July 2026
- Published by Elsevier in Physica Medica
- Vol. 148, 105874
DARL-Net: Deformable-asymmetric residual learning and learnable non-local attention-based low-dose CT image denoising
- 9 July 2026
- Published by Elsevier in Physica Medica
- Vol. 148, 105874
DARL-Net: Deformable-asymmetric residual learning and learnable non-local attention-based low-dose CT image denoising
- Open Access
- 20 February 2026
- Published by Elsevier in Artificial Intelligence in Emergency Medicine
- Vol. 1
A multi-domain feature-based ensemble learning approach for cuffless blood pressure estimation
- 20 February 2026
- Published by Elsevier in Artificial Intelligence in Emergency Medicine
- Vol. 1
Open AccessA multi-domain feature-based ensemble learning approach for cuffless blood pressure estimation
- 4 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 27 (3) , 108-109
IEEE Day 2025 Celebration by IEEE MTT-S Student Branch Chapter IIT BHU Varanasi [Around the Globe]
- 4 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 27 (3) , 108-109
IEEE Day 2025 Celebration by IEEE MTT-S Student Branch Chapter IIT BHU Varanasi [Around the Globe]
- 4 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 27 (3) , 110-111
Report on DML Talk Organized by IEEE MTT-S Student Branch Chapter IIT BHU Varanasi [Around the Globe]
- 4 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 27 (3) , 110-111
Report on DML Talk Organized by IEEE MTT-S Student Branch Chapter IIT BHU Varanasi [Around the Globe]
- 11 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
QCM-Based Electronic Nose for Near-Real-Time BTEX Detection
The detection of Benzene, Toluene, Ethylbenzene, and Xylene (BTEX) is critical for safety in the oil and gas industry due to their toxic and carcinogenic effects. This study presents a portable Electronic Nose (E-Nose) system based on Quartz Crystal Microbalance (QCM)-coated with Polyvinyl Acetate (PVAc) and Tungsten Oxide (WO₃) for near-real-time detection of BTEX vapours in ambient conditions. The PVAc-coated QCM sensor achieved high sensitivity for benzene (5.14 ± 0.25 Hz/ppm) and ethylbenzene (5.85 ± 0.31 Hz/ppm), while the WO₃-coated sensor demonstrated notable sensitivity to toluene (5.69 ± 0.22 Hz/ppm). The sensitivity for xylene was in the range of 5.00 ± 0.31 Hz/ppm for both the sensor. The Limits of Detection (LOD) for PVAc and WO₃ coated sensors for BTEX were 1.69 ppm and 1.26 ppm, respectively. The system was validated using Gas Chromatography-Mass Spectrometry (GC-MS), verifying the accurate detection of less than 4 ppm BTEX mixture with 2-3 min analysis times. Principal Component Analysis (PCA) combined with clustering algorithms, such as k-Means and BIRCH, provided high classification accuracy, achieving Silhouette scores of 0.53 and 0.51, respectively. This work demonstrates a novel approach to integrating QCM sensors with advanced data analytics for effective near-real-time BTEX monitoring in industrial environments.
- 11 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
QCM-Based Electronic Nose for Near-Real-Time BTEX Detection
The detection of Benzene, Toluene, Ethylbenzene, and Xylene (BTEX) is critical for safety in the oil and gas industry due to their toxic and carcinogenic effects. This study presents a portable Electronic Nose (E-Nose) system based on Quartz Crystal Microbalance (QCM)-coated with Polyvinyl Acetate (PVAc) and Tungsten Oxide (WO₃) for near-real-time detection of BTEX vapours in ambient conditions. The PVAc-coated QCM sensor achieved high sensitivity for benzene (5.14 ± 0.25 Hz/ppm) and ethylbenzene (5.85 ± 0.31 Hz/ppm), while the WO₃-coated sensor demonstrated notable sensitivity to toluene (5.69 ± 0.22 Hz/ppm). The sensitivity for xylene was in the range of 5.00 ± 0.31 Hz/ppm for both the sensor. The Limits of Detection (LOD) for PVAc and WO₃ coated sensors for BTEX were 1.69 ppm and 1.26 ppm, respectively. The system was validated using Gas Chromatography-Mass Spectrometry (GC-MS), verifying the accurate detection of less than 4 ppm BTEX mixture with 2-3 min analysis times. Principal Component Analysis (PCA) combined with clustering algorithms, such as k-Means and BIRCH, provided high classification accuracy, achieving Silhouette scores of 0.53 and 0.51, respectively. This work demonstrates a novel approach to integrating QCM sensors with advanced data analytics for effective near-real-time BTEX monitoring in industrial environments.
- 11 June 2025
- Published by Springer Nature
- p. 463-480
Ambulatory ECG Measurement Denoising and Implementation for Smart Healthcare Applications
- 11 June 2025
- Published by Springer Nature
- p. 463-480
Ambulatory ECG Measurement Denoising and Implementation for Smart Healthcare Applications
- 11 April 2025
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 44 (8) , 6006-6026
Dynamic Perception-oriented Low-dose CT Image Denoising Network using Structure-aware Self-similarity
- 11 April 2025
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 44 (8) , 6006-6026
Dynamic Perception-oriented Low-dose CT Image Denoising Network using Structure-aware Self-similarity
- 18 March 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 190, 109965
Asymmetric Convolution-based GAN Framework for Low-Dose CT Image Denoising
- 18 March 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 190, 109965
Asymmetric Convolution-based GAN Framework for Low-Dose CT Image Denoising
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Voxel-Sensitive Attention-Based Lattice Structure Residual Network for Low-Dose CT Image Denoising Using Wavelet-Based Structure Loss
Low-dose computed tomography (LDCT) imaging safeguards patients from potentially harmful X-rays. However, the signal-to-noise ratio (SNR) and CT image quality deteriorate due to lower X-ray flux in the LDCT imaging modality. The custom design of deep networks with vanilla convolution layers ignores sensitive voxel information. Hence, voxel details for reconstructing low-contrast regions and high-frequency lesion edges may be lost during noise suppression. In addition, existing techniques do not satisfactorily address the problem of adversarial learning-induced structural deformation. This paper proposes a low-dose CT denoising method based on Wasserstein GAN (WGAN) with three novel contributions. First, we introduce a novel build block called a voxel-sensitive attention-based lattice residual block (VSA-LRB). The generator network with stacked VSA-LRB can preserve the long-range pixel dependency while aggregating the voxel-sensitive features extracted along the spatial (H ×W) and depth-wise (D) directions. Furthermore, we train the proposed denoising network to learn efficient structural features via our proposed wavelet-based structural loss. The error is estimated on the wavelet-domain structural feature space, extracted by a dedicated pre-trained CT-specific structure-aware network (CT-SANet). Hence, the wavelet-based loss function effectively mitigates structural distortions. We introduce a differential content loss to improve high-frequency lesion boundaries. The proposed method is validated qualitatively and quantitatively using two publicly available datasets: the ”2016 NIH-AAPM-Mayo Clinic LDCT Grand Challenge dataset” and the” Low-dose-CT Image and Projection dataset.” The proposed method demonstrates a superior performance as compared to state-of-the- art techniques.
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Voxel-Sensitive Attention-Based Lattice Structure Residual Network for Low-Dose CT Image Denoising Using Wavelet-Based Structure Loss
Low-dose computed tomography (LDCT) imaging safeguards patients from potentially harmful X-rays. However, the signal-to-noise ratio (SNR) and CT image quality deteriorate due to lower X-ray flux in the LDCT imaging modality. The custom design of deep networks with vanilla convolution layers ignores sensitive voxel information. Hence, voxel details for reconstructing low-contrast regions and high-frequency lesion edges may be lost during noise suppression. In addition, existing techniques do not satisfactorily address the problem of adversarial learning-induced structural deformation. This paper proposes a low-dose CT denoising method based on Wasserstein GAN (WGAN) with three novel contributions. First, we introduce a novel build block called a voxel-sensitive attention-based lattice residual block (VSA-LRB). The generator network with stacked VSA-LRB can preserve the long-range pixel dependency while aggregating the voxel-sensitive features extracted along the spatial (H ×W) and depth-wise (D) directions. Furthermore, we train the proposed denoising network to learn efficient structural features via our proposed wavelet-based structural loss. The error is estimated on the wavelet-domain structural feature space, extracted by a dedicated pre-trained CT-specific structure-aware network (CT-SANet). Hence, the wavelet-based loss function effectively mitigates structural distortions. We introduce a differential content loss to improve high-frequency lesion boundaries. The proposed method is validated qualitatively and quantitatively using two publicly available datasets: the ”2016 NIH-AAPM-Mayo Clinic LDCT Grand Challenge dataset” and the” Low-dose-CT Image and Projection dataset.” The proposed method demonstrates a superior performance as compared to state-of-the- art techniques.