Melaty Amirruddin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Melaty Amirruddin has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Hana Abdull Halim
School of Electrical Engineering and Telecommunications, University of New South Wales, Sydney, Australia
5 shared publications - Mohd Rafi Adzman
Universiti Malaysia Perlis
4 shared publications Muhd Hafizi Idris
Centre of Excellence for Renewable Energy (CERE) School of Electrical System Engineering, Universiti Malaysia Perlis, Arau, Malaysia
4 shared publicationsNurhakimah M. Mukhtar
4 shared publicationsFarrah Salwani Abdullah
PPK Sistem Elektrik, Universiti Malaysia Perlis
2 shared publications- Mohd Alif Ismail
School of Electrical System Engineering, Universiti Malaysia Perlis (UniMAP), Kampus UniMAP Pauh Putra, 02600 Arau, Perlis, Malaysia
2 shared publications
Latest Publications
- Open Access
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (6) , 7254-7265
Improved impressed current cathodic protection systems by incorporating a pulse-feeding technique integrated with internet of things capabilities
This paper introduces an innovative improvement to impressed current cathodic protection (ICCP) systems by integrating a pulse-feeding technique designed to address metal protection degradation during off-potential periods, a common issue in conventional systems. The proposed system enhances the overall effectiveness and reliability of ICCP, providing consistent corrosion protection for critical metal structures. A notable advantage of this method is its simplicity, utilizing a cost-effective microcontroller for pulse feeding. This approach simplifies integration processes and enhances cost-effectiveness, making it an attractive solution for improving cathodic protection system performance without substantial additional costs. The method addresses conventional ICCP weaknesses by applying a high-frequency pulse current during off-potential periods. This reduces excessive negative charge buildup on metal surfaces during interruptions, boosting the system’s effectiveness and stability. Research laboratory experiments were conducted using pulse width modulation (PWM) on an ATmega328P microcontroller to demonstrate the method’s effectiveness. Additionally, an IoT-monitored ICCP system was developed using an ESP32 microcontroller and the Blynk application. Results highlight the superiority of a 50 kHz pulse feeding frequency in preventing corrosion compared to lower frequencies. Overall, this advancement significantly enhances ICCP systems, providing improved corrosion protection and durability in harsh environments.
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (6) , 7254-7265
Open AccessImproved impressed current cathodic protection systems by incorporating a pulse-feeding technique integrated with internet of things capabilities
This paper introduces an innovative improvement to impressed current cathodic protection (ICCP) systems by integrating a pulse-feeding technique designed to address metal protection degradation during off-potential periods, a common issue in conventional systems. The proposed system enhances the overall effectiveness and reliability of ICCP, providing consistent corrosion protection for critical metal structures. A notable advantage of this method is its simplicity, utilizing a cost-effective microcontroller for pulse feeding. This approach simplifies integration processes and enhances cost-effectiveness, making it an attractive solution for improving cathodic protection system performance without substantial additional costs. The method addresses conventional ICCP weaknesses by applying a high-frequency pulse current during off-potential periods. This reduces excessive negative charge buildup on metal surfaces during interruptions, boosting the system’s effectiveness and stability. Research laboratory experiments were conducted using pulse width modulation (PWM) on an ATmega328P microcontroller to demonstrate the method’s effectiveness. Additionally, an IoT-monitored ICCP system was developed using an ESP32 microcontroller and the Blynk application. Results highlight the superiority of a 50 kHz pulse feeding frequency in preventing corrosion compared to lower frequencies. Overall, this advancement significantly enhances ICCP systems, providing improved corrosion protection and durability in harsh environments.
- Open Access
- 1 January 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1432 (1) , 012066
Analysis of flexible antenna performance on partial discharges detection
This paper reports a short finding on the use of a flexible substrate in the design of Partial discharge (PD) detection antenna. This flexible antenna was designed and simulated using CST Microwave Studio to detect corona discharge which is one types of PD that occur in power transformers. The flexible substrate that been used in designing the antenna is paper that has permittivity of 3.2 and the chosen frequency is between 300MHz until 3GHz. The overall dimension is 208×168×1.6 mm3. The simulations of the antenna’s return loss were conducted under two conditions; 1) flat and 2) bending along H- planes. The result were been analysed to understand the performance of paper properties, so that practical system requirements are met. This implies that the performance of paper antennas can be used in the PD field with altering some of the characteristic to upgrade its performance.
- 1 January 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1432 (1) , 012066
Open AccessAnalysis of flexible antenna performance on partial discharges detection
This paper reports a short finding on the use of a flexible substrate in the design of Partial discharge (PD) detection antenna. This flexible antenna was designed and simulated using CST Microwave Studio to detect corona discharge which is one types of PD that occur in power transformers. The flexible substrate that been used in designing the antenna is paper that has permittivity of 3.2 and the chosen frequency is between 300MHz until 3GHz. The overall dimension is 208×168×1.6 mm3. The simulations of the antenna’s return loss were conducted under two conditions; 1) flat and 2) bending along H- planes. The result were been analysed to understand the performance of paper properties, so that practical system requirements are met. This implies that the performance of paper antennas can be used in the PD field with altering some of the characteristic to upgrade its performance.
- 31 December 2019
- Published by Institute of Advanced Scientific Research in Journal of Advanced Research in Dynamical and Control Systems
- Vol. 11 (12-SPECIAL) , 871-878
Assessing Voltage Sags Caused by Transformer Energisation
- 31 December 2019
- Published by Institute of Advanced Scientific Research in Journal of Advanced Research in Dynamical and Control Systems
- Vol. 11 (12-SPECIAL) , 871-878
Assessing Voltage Sags Caused by Transformer Energisation
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 19, 1-6
Evaluation of Denoising Performance for Noisy Arc Fault Signal Based on Mother Wavelet Selection
Arc fault detection in a power system network is a vital diagnostic test for condition monitoring in order to remain the consistency of the service. The issue of electrical faults has been largely investigated in the literature to foresee the existence of arc fault at the earliest stage. However, the identification measurement has faced noise disturbance from surrounding area. Thus, this paper presents an arc fault signals detection and analysis using Discrete Wavelet Transform (DWT) technique as a denoising technique. The effectiveness that influence the different types of mother wavelets is analyzed based on calculated signal to noise ratio (SNR) before denoising and after denoising, mean square error (MSE), correlation coefficient (CC) and mean absolute percentage error (MAPE). Each mother wavelet will be used to extract important features of a voltage signal from a single measurement point that were performed under 4th decomposition level using Universal (Sqtwolog) thresholding rule with soft thresholding function.The results are manipulated based on Haar (haar), Daubechies (db), Symlets (sym), Coiflets (coif), BiorSplines (bior) and Reverse-Bior (rbio) mother wavelets. The outcome demonstrates the data analysis approaches can provide better understanding to obtain the most optimum mother wavelet hence can enhance the performance of arc fault detection using wavelet transform as a denoising purposed.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 19, 1-6
Evaluation of Denoising Performance for Noisy Arc Fault Signal Based on Mother Wavelet Selection
Arc fault detection in a power system network is a vital diagnostic test for condition monitoring in order to remain the consistency of the service. The issue of electrical faults has been largely investigated in the literature to foresee the existence of arc fault at the earliest stage. However, the identification measurement has faced noise disturbance from surrounding area. Thus, this paper presents an arc fault signals detection and analysis using Discrete Wavelet Transform (DWT) technique as a denoising technique. The effectiveness that influence the different types of mother wavelets is analyzed based on calculated signal to noise ratio (SNR) before denoising and after denoising, mean square error (MSE), correlation coefficient (CC) and mean absolute percentage error (MAPE). Each mother wavelet will be used to extract important features of a voltage signal from a single measurement point that were performed under 4th decomposition level using Universal (Sqtwolog) thresholding rule with soft thresholding function.The results are manipulated based on Haar (haar), Daubechies (db), Symlets (sym), Coiflets (coif), BiorSplines (bior) and Reverse-Bior (rbio) mother wavelets. The outcome demonstrates the data analysis approaches can provide better understanding to obtain the most optimum mother wavelet hence can enhance the performance of arc fault detection using wavelet transform as a denoising purposed.
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Design of Triangle Loop Antenna for Partial Discharge Impulse Signal Detection
The objective of this study was to evaluate the performance of a triangle loop antenna to assess its use as a potential sensor in partial discharge (PD) impulse signals detection. PD impulse signals were measured over a frequency up to 100 MHz at 3 kV through Needle-Plate Electrode experiment. The experiment was conducted to create an artificial PD acting as a breakdown that causes insulation failure. Subsequently, the characteristic of PD impulse signals was captured by triangle loop antenna with variation of diameters and number of turns. The number of turns is up to three turns and diameters of triangle loop antenna intervals are 6 cm, 8 cm and 10 cm. Then, the Fast Fourier Transforms (FFT) analysis was carried out to measure the frequency bandwidth. The results revealed that an experimental frequency is 32.01 MHz. Then, it can be observed that the amplitude value of peak-to-peak voltage (Vpp) for three turns 10 cm diameter of triangle loop antenna higher than the amplitude value for one turn and two turns of triangle loop antennas.
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Design of Triangle Loop Antenna for Partial Discharge Impulse Signal Detection
The objective of this study was to evaluate the performance of a triangle loop antenna to assess its use as a potential sensor in partial discharge (PD) impulse signals detection. PD impulse signals were measured over a frequency up to 100 MHz at 3 kV through Needle-Plate Electrode experiment. The experiment was conducted to create an artificial PD acting as a breakdown that causes insulation failure. Subsequently, the characteristic of PD impulse signals was captured by triangle loop antenna with variation of diameters and number of turns. The number of turns is up to three turns and diameters of triangle loop antenna intervals are 6 cm, 8 cm and 10 cm. Then, the Fast Fourier Transforms (FFT) analysis was carried out to measure the frequency bandwidth. The results revealed that an experimental frequency is 32.01 MHz. Then, it can be observed that the amplitude value of peak-to-peak voltage (Vpp) for three turns 10 cm diameter of triangle loop antenna higher than the amplitude value for one turn and two turns of triangle loop antennas.
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 29-33
Auto-reclose Relay Simulation for Research and Education
Auto-reclose relay is an important relay used to reenergize a line after the line was tripped by main protection relay due to fault occurrence. Failure of auto-reclose relay to reenergize the line will make power can't be transmitted through the line and power system will be in stress condition. Knowledge of auto-reclose protection scheme is quite difficult to be understood and only few power system software has auto-reclose model for power system study and the software are costly. This research is about modelling auto-reclose relay and its' scheme using Matlab Simulink. The developed model has been developed with some limitations to simplify the modelling process and the results gained show the capability of Matlab Simulink software to be used to model the scheme for education and research purpose.
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 29-33
Auto-reclose Relay Simulation for Research and Education
Auto-reclose relay is an important relay used to reenergize a line after the line was tripped by main protection relay due to fault occurrence. Failure of auto-reclose relay to reenergize the line will make power can't be transmitted through the line and power system will be in stress condition. Knowledge of auto-reclose protection scheme is quite difficult to be understood and only few power system software has auto-reclose model for power system study and the software are costly. This research is about modelling auto-reclose relay and its' scheme using Matlab Simulink. The developed model has been developed with some limitations to simplify the modelling process and the results gained show the capability of Matlab Simulink software to be used to model the scheme for education and research purpose.
- Open Access
- 1 February 2017
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 97, 01001
Mathematical Derivation of Switching Angles of Multilevel Voltage Source Inverter based on Alternative Phase Opposition Disposition (APOD)
MATEC Web of Conferences, open access proceedings in Materials science, Engineering and Chemistry
- 1 February 2017
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 97, 01001
Open AccessMathematical Derivation of Switching Angles of Multilevel Voltage Source Inverter based on Alternative Phase Opposition Disposition (APOD)
MATEC Web of Conferences, open access proceedings in Materials science, Engineering and Chemistry
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 40-44
Modeling and simulation of inverse time overcurrent relay using Matlab/Simulink
Overcurrent relay is an important relay used to protect transmission and distribution feeders, transformer, bus coupler etc. It can be used as main or backup protection relays. The modeling of overcurrent relay and other protection relays is important in the research on the effects of network parameters and configurations on the operation of these relays. This research deal with modeling and simulation of inverse time overcurrent relay using commonly used Matlab/Simulink software. The developed model was tested with single line to ground fault and phase to phase fault with various fault locations and fault resistances to evaluate phase and earth detectors in sensing the fault current. Simulations results show the feasibility of the software to be used to develop the relay.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 40-44
Modeling and simulation of inverse time overcurrent relay using Matlab/Simulink
Overcurrent relay is an important relay used to protect transmission and distribution feeders, transformer, bus coupler etc. It can be used as main or backup protection relays. The modeling of overcurrent relay and other protection relays is important in the research on the effects of network parameters and configurations on the operation of these relays. This research deal with modeling and simulation of inverse time overcurrent relay using commonly used Matlab/Simulink software. The developed model was tested with single line to ground fault and phase to phase fault with various fault locations and fault resistances to evaluate phase and earth detectors in sensing the fault current. Simulations results show the feasibility of the software to be used to develop the relay.
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 337-341
An Improved Protection Scheme for Smart Distribution Grid
This paper presents an implementation to enhance the protection scheme of smart distribution grid. In order to improve the existing protection scheme used in Malaysia that is "Current Differential Protection", to a new level of protection that used the idea of combining the "Current Differential Protection" and "Fast Current Protection". This project was developed to increase the efficiency of protection, decrease any unnecessary cost regarding the protection maintenance or equipment used, and space used for installing a particular protection scheme. Besides that, neither "Current Differential Protection" nor "Fast Current Protection" has their own advantages and disadvantages for their perspective protection scheme. The results were proven by simulating the design using PSCAD software, which the new design, combined both theories of "Current Differential Protection" and "Fast Current Protection". The building cost for the new design can be reduced in installation or maintenance.
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 337-341
An Improved Protection Scheme for Smart Distribution Grid
This paper presents an implementation to enhance the protection scheme of smart distribution grid. In order to improve the existing protection scheme used in Malaysia that is "Current Differential Protection", to a new level of protection that used the idea of combining the "Current Differential Protection" and "Fast Current Protection". This project was developed to increase the efficiency of protection, decrease any unnecessary cost regarding the protection maintenance or equipment used, and space used for installing a particular protection scheme. Besides that, neither "Current Differential Protection" nor "Fast Current Protection" has their own advantages and disadvantages for their perspective protection scheme. The results were proven by simulating the design using PSCAD software, which the new design, combined both theories of "Current Differential Protection" and "Fast Current Protection". The building cost for the new design can be reduced in installation or maintenance.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21668523,p. 300-305
Simulation Study of the Transient Recovery Voltage (TRV) on Circuit Breaker
This project is to present the transient recovery voltage on circuit breaker in power system network. The transient recovery voltage is a characteristic in power system and will found just only microsecond in the power system network. The objective of this project is to simulate and analysis the transient recovery voltage on circuit breaker. It is to investigate the transient recovery voltage before and after the circuit breaker interrupts and also the transient recovery voltage under the fault. The method used in this project is by simulating the circuit using the PSCAD software. This software will simulate the circuit model and collect some data to give more understanding about transient recovery voltage. This project will continue by analyzing the result based on the data collected. The simulation results are same with the expected results and thus, it show that the simulation results are correct and pre theoretical. In conclusion, the transient recovery voltage affects the breaking capacity of the circuit breaker operation and also affects the power system network operation.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21668523,p. 300-305
Simulation Study of the Transient Recovery Voltage (TRV) on Circuit Breaker
This project is to present the transient recovery voltage on circuit breaker in power system network. The transient recovery voltage is a characteristic in power system and will found just only microsecond in the power system network. The objective of this project is to simulate and analysis the transient recovery voltage on circuit breaker. It is to investigate the transient recovery voltage before and after the circuit breaker interrupts and also the transient recovery voltage under the fault. The method used in this project is by simulating the circuit using the PSCAD software. This software will simulate the circuit model and collect some data to give more understanding about transient recovery voltage. This project will continue by analyzing the result based on the data collected. The simulation results are same with the expected results and thus, it show that the simulation results are correct and pre theoretical. In conclusion, the transient recovery voltage affects the breaking capacity of the circuit breaker operation and also affects the power system network operation.