BPBorislava Petrovic

Borislava Petrovic

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Borislava Petrovic has a total of 101 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • EURADOS survey on IGRT practices in European radiotherapy clinics

    by Milana Vezirović, Teemu Siiskonen, Borislava Petrović, Toni Kansanoja, Serhii Brovchuk

  • Open Access

    Assessment of occupational eye lens exposure during image-guided orthopedic procedures

    by Jelena J. Samac, Predrag M. Božović, Jelena S. Stanković-Petrović, Borislava Petrovic, Miodrag N. Vranješ, Predrag V. Rašović, Mirko M. Obradović

    This study aimed to investigate the level of exposure of eye lenses in orthopedic surgeons performing routine clinical work and to determine future monitoring practice, as Serbian radiation protection law still employs higher limits. The dose was measured monthly in terms of H (0.03) with three different dosimeters placed on a 3-D-printed headband, worn on a forehead by three orthopedic surgeons, during all procedures involving fluoroscopy. The mean dose for the left and right eye was 271 ? 109 ?Sv and 269 ? 101 ?Sv, respectively, with no significant difference (p-value 0.977) between the left and right eye observed. Considering the highest recorded monthly value, the annual dose is expected to be 4.85 mSv without protective items, well below the new ICRP limit of 20 mSv. There was no observed correlation between eye lens dose and both fluoroscopy time and exposure parameters. Considering the cumulative impact of dose and the evidence pointing to an elevated incidence of lenticular opacities for cumulative doses exceeding 10 mSv, it is advisable to institute ongoing monitoring, especially when new surgeons incorporate image-guided procedures or when novel techniques are introduced into surgical practice.


  • Open Access

    Ultra-Hypofractionated vs. Moderate Fractionated Whole Breast Three Dimensional Conformal Radiotherapy during the COVID-19 Pandemic

    by Olivera Ivanov, Aleksandra Milovančev, Borislava Petrović, Nataša Prvulović Bunović, Jelena Ličina, Marko Bojović, Ivan Koprivica, Milijana Rakin, Milana Marjanović, Dejan Ivanov, et al.

    Background and Objectives: Reducing time of treatment during COVID-19 outbreaks has been recommended by the leading Radiation Oncology societies. Still minimizing radiation induced tissue toxicity is one of the most important issues in breast cancer patients. The study aimed to investigate compliance, clinical and dosimetry normal tissue toxicity, and cosmetic results between moderated and ultra-fractionated regimes for breast cancer patients during COVID-19 pandemic. Materials and Methods: This pilot prospective randomized study included 60 patients with early breast cancer after preserving surgery, 27 patients advocated to ultra-hypofractionated whole-breast three dimensional (3D) conformal radiotherapy of 26 Gy in 5 fractions over 1 week and 33 patients with moderate fractionated breast 3D conformal radiotherapy patients between March 2020 and July 2020, during the COVID pandemic outbreak. The compliance to treatment, dosimetric parameters, acute and late skin toxicity, subcutaneous tissue toxicity, cosmetic results and clinical follow up for 18 months for the two regimes were analyzed and compared. Results: When two regimes were compared 5 fraction group had significantly lower prevalence of newly infected cases of SARS-CoV-2 and thus delayed/interrupted treatment (p = 0.05), comparable grade 1 CTCAE v5, acute skin toxicity (p = 0.18), Grade 1 Radiation Morbidity Scoring Scheme (RESS) subcutaneous tissue toxicity (p = 0.18), Grade 1 RESS late skin toxicity (p = 0.88) and cosmetic results (p = 0.46). Dosimetric results reveled that patients in 5 fraction group received significantly lower median ipsilateral lung doses (p < 0.01) in addition to left breast cancer patients that received significantly lower median heart dose (p < 0.01) and median left anterior descending artery (LAD) dose (p < 0.01). Conclusion: Ultra-hypofractionated radiotherapy for breast cancer is comparable to moderate hypofractionation regimen regarding grade 1 acute skin toxicity, grade 1 subcutaneous tissue toxicity, late skin toxicity and cosmetic results. Application of ultra-hypofractionated radiotherapy with significantly lower radiation doses for lung and heart could be crucial in reducing the risk of acute/late pulmonary and heart radiation-induced toxicity.


  • Open Access

    Left breast radiotherapy – the impact of heart and left anterior descending artery doses to cardiovascular diseases developed eight years after treatment

    by Borislava Petrovic, Milovan Petrovic, Branislav Djuran, Igor Djan, Tatjana Miljkovic, Milenko Cankovic, Csilla Pesznyak, Laza Rutonjski, Olivera Ivanov

    Introduction/Objective. Left breast cancer patients undergoing radiotherapy are at higher risk of cardiovascular diseases (CVD), as a partial volume of the heart is anatomically close to target volume. This may cause cardiovascular diseases in the years following cancer treatment. The aim of this work was to develop a scoring system which identifies patients with increased risk of development of cardiovascular diseases, as consequence of left breast irradiation. Methods. The patients followed up in this study were treated during 2009. Eight years later, they were invited to participate in a study where they underwent a cardiology evaluation. Their current condition was statistically correlated to the doses received by their heart and left anterior descendant (LAD) artery. Results. Out of 114 patients, thirty-one women were evaluable for cardiology assessment. Out of these 31 subjects, six women were with a history of CVD before cancer treatment. Four women never developed any kind of heart associated disease, while in the other 27, newly onset CVD were diagnosed ranging from hypertension to myocardial infarction, strongly positively correlated to doses to heart and LAD (p = 0.003). Severity of developed cardiovascular toxicity was formulated through the correlation of mean heart and mean LAD doses with cardiovascular diseases developed in form of the scoring system. Conclusion. The doses to critical organs depend on patient anatomy and technique of irradiation. The cardiovascular complications are proven as consequence of radiotherapy. Scoring system based on doses received by heart and LAD is reliable tool in predicting CVD.


  • Open Access

    Implementation of accelerated partial breast irradiation at the Oncology Institute of Vojvodina

    by Olivera Ivanov, Jelena Licina, Borislava Petrovic, Jelena Trivkovic, Milana Marjanovic

    Introduction. Early breast cancer is usually treated with breast conserving surgery followed by radiation treatment. Whole breast irradiation is standard of care so far, but currently there is an increasement in accelerated partial breast irradiation for selected patients which showed many advantages. The aim of this paper is to present the implementation of the accelerated partial breast irradiation in Oncology Institute of Vojvodina. Case outline. A 54-year-old woman was referred to radiotherapy after breast conserving surgery. After she met all of the inclusion criteria, she underwent accelerated partial breast irradiation with 38.5 Gy in 10 fractions. Active breathing control device was used during the treatment and cone beam computed tomography was performed before each fraction for the purpose of target position control. She terminated therapy in good health condition with only adverse effect of mild radiation dermatitis of irradiated area. On the first follow up, she was without any symptom or sign of disease or complication. Conclusion. Accelerated partial breast irradiation is safe and effective. Radiation oncologist should be encouraged to implement this technique.


  • Open Access

    The transition from conformal to advanced radiotherapy techniques in the treatment planning of gynecological cancer patients

    by Borislava Petrovic, Olivera Ivanov, Milana Marjanovic, Jelena Licina, Ivan Gencel, Nemanja Golubovac

    Background/Aim. The transition from standard to highly conformal radiation therapy techniques requires the implementation of complex advanced dosimetry. The aim of the study was to compare dosimetric parameters of the three-dimensional conformal radiotherapy (3DCRT) and volumetric modulated arc therapy (VMAT) plan, as well as complications after treatment in relation to dosimetric parameters in gynecological cancer patients. Methods. A total of 49 gynecological cancer patients were included in the study. All patients were planned for 3DCRT, but due to unacceptable doses to organs at risk (OARs), treatment plans for intensity modulated radiation therapy (IMRT), or VMAT, were generated for 21 patients. The patients were prescribed 50.4 Gy/28 fractions (4 patients) and 45 Gy/25 fractions (45 patients). The coverage of planning target volume (PTV) and doses to OARs were recorded. PTV margins were evaluated for both techniques according to the Van Herk formula. Results. ICRU 83 criteria were fulfilled in all 3DCRT/ VMAT/IMRT plans providing optimal coverage of PTV. Doses to OARs, on average, the V45Gy in the small bowel in IMRT/VMAT plans was four times smaller than the same in 3DCRT plans. The V45 Gy of small bowels was, on average, 49.4 cm(3) in IMRT/VMAT plans, while in 3DCRT plans, it was 211.6 cm(3). In the case of the femoral head, a significant reduction in V30Gy (10.8% vs. 33.1%) and mean dose in the case of IMRT/VMAT plans was recorded (30.4 Gy in 3DCRT vs. 23.6 Gy). Rectum was planned with a significantly lower dose in terms of V30Gy (79.5% vs. 95.2%) in IMRT/VMAT plans. The bladder was better spared in VMAT plans in terms of V40Gy (51% vs. 91%), but the maximum dose was higher in VMAT plans than in 3DCRT (50.1 Gy to 48.1 Gy on average). For all OARs, there was a statistically significant difference registered at p < 0.05. Toxicities recorded in VMAT and 3DCRT patients included mainly radiation-induced cystitis and enteritis. Patients treated with 3DCRT generally had longer recovery time. The homogeneity index was 0.11 for VMAT plans and 0.09 for 3DCRT plans. Conclusions. Analysis of dosimetric parameters revealed significant differences in normal tissue doses for the same 3DCRT and VMAT patients, which confirmed the necessity for the implementation of advanced techniques for as many patients as possible.

  • Occupational radiation dose of personnel involved in sentinel node biopsy procedure

    by Borislava Petrovic, Ferenc Vicko, Dragana Radovanovic, Jelena Samac, Arpad Tot, Zoran Radovanovic, Tatjana Ivkovic- Kapicl, Dejan Lukic, Milana Marjanovic, Olivera Ivanov


  • Open Access

    Assessment of computed tomography simulators used in radiotherapy treatment planning in Serbia, Croatia, and Bosnia and Herzegovina

    by Borislava S. Petrović, Dario Z. Faj, Mladen B. Marković, Arpad A. Tot, Milana S. Marjanović, Mladen D. Kasabašić, Ivan V. Gencel, Dragomir R. Paunović, Jelena V. Stanković, Jelena Krestic-Vesovic, et al.

    The purpose of this work was to evaluate computed tomography (CT) simulators used in radiotherapy treatment planning in Serbia, Croatia and Bosnia and Herzegovina. A survey of quality assurance programmes of 24 CT simulators in 16 facilities was conducted. Dedicated CT-to-ED phantom was scanned at 120 kV and 140 kV, to obtain CT-to-ED (ED- Electron Density) conversion curves as well as CTDIvol. Thoracal phantoms were scanned in standard and extended field of view to evaluate dosimetric effect on treatment planning and delivery. Mean age of measured scanners was 5.5 years. The mean water HU value was -6.5 (all scanners, all voltages) and air HU value was -997. Extended field of view CT data differ from standard field of view and differences between conversion curves have significant dosimetric impact. The CTDI data showed large range of values between centers. Better QA of CT simulators in all countries is recommended. CT-to-ED curve could be used as default at one voltage and per manufacturer. Extended field of view imaging can be used, but treatment planning should be avoided in the regions out of standard field of view.


  • Open Access

    An IAEA survey of radiotherapy practice including quality assurance extent and depth

    by B. J. Healy, M. Budanec, B. Ourdane, T. Peace, B. Petrovic, D. E. Sanz, D. J. Scanderbeg, L. Tuntipumiamorn

    Background: The IAEA recommends a quality assurance program in radiotherapy to ensure safe and effective treatments. In this study, radiotherapy departments were surveyed on their current practice including the extent and depth of quality assurance activities. Methods: Radiotherapy departments were voluntarily surveyed in three stages, firstly, in basic facility information, secondly, in quality assurance activities and treatment techniques, and thirdly, in a snapshot of quality assurance, departmental and treatment activities. Results: The IAEA received completed surveys from 381 radiotherapy departments throughout the world with 100 radiotherapy departments completing all three surveys. Dominant patterns were found in linac-based radiotherapy with access to treatment planning systems for 3D-CRT and 3D imaging. Staffing levels for major staff groups were on average in the range recommended by the IAEA. The modal patient workload per EBRT unit was as expected in the range of 21–30 patients per day, however significant instances of high workload (more than 50 patients per day per treatment unit) were reported. Staffing levels were found to correlate with amount of treatment equipment and patient workload. In a self-assessment of quality assurance performance, most radiotherapy departments reported that they would perform at least 60% of the quality assurance activities itemized in the second survey, with particular strength in equipment quality control. In a snapshot survey of quality assurance performance, again equipment quality control practice was well developed, particularly for the treatment equipment. Conclusions: The IAEA surveys provide a snapshot of current radiotherapy practice including quality assurance activities.