Matteo Moratti
Research Subjects
Matteo Moratti has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Nicola Scattarreggia
University School for Advanced Studies IUSS Pavia, Pavia, Italy
3 shared publications - Andrea Orgnoni
University School for Advanced Studies, IUSS Pavia, Pavia, Italy
2 shared publications Gian Michele Calvi
2 shared publications- Paolo Martino Calvi
Department of Civil and Environmental engineering, University of Washington, Seattle, WA 98195, USA
2 shared publications - Rui Pinho
Department of Civil Engineering and Architecture, University of Pavia, 27100 Pavia, Italy
2 shared publications Andrea Orgnoni
Engineering Consultant, Modelling and Structural Analysis Consulting, Mosayk Ltd., Via Fratelli Cuzio 42, 27100 Pavia, Italy
1 shared publication
Latest Publications
- Open Access
Seismic Strengthening of Elevated Reinforced Concrete Tanks: Analytical Framework and Validation Techniques
The prevalence of elevated reinforced concrete tanks is widespread across Italian water distribution networks, particularly in flat or low-relief areas. Primarily constructed by the late 1970s, these tanks often suffer from outdated hydraulic efficiency, unable to cope with the increasing urban water demands. With rising construction costs, the economic advantage has shifted toward underground tanks, leading to the decommissioning of many elevated tanks. Despite being obsolete, elevated tanks from the 1960s and 1970s still stand in densely urbanized regions. However, demolishing them may prove less cost-effective than retrofitting to restore their original structural capacity. The widespread presence of these structures, coupled with their susceptibility to decay from weathering and poor maintenance, necessitates a comprehensive assessment of their resilience against gravitational and lateral forces, including seismic activity. Consequently, there is a pressing need to develop an analysis and verification methodology, particularly focused on seismic resilience, tailored to existing elevated tanks. These structures, distinct from conventional reinforced concrete frames, are primarily designed to withstand vertical forces, emphasizing the importance of optimizing material usage in their retrofitting efforts.
Open AccessSeismic Strengthening of Elevated Reinforced Concrete Tanks: Analytical Framework and Validation Techniques
The prevalence of elevated reinforced concrete tanks is widespread across Italian water distribution networks, particularly in flat or low-relief areas. Primarily constructed by the late 1970s, these tanks often suffer from outdated hydraulic efficiency, unable to cope with the increasing urban water demands. With rising construction costs, the economic advantage has shifted toward underground tanks, leading to the decommissioning of many elevated tanks. Despite being obsolete, elevated tanks from the 1960s and 1970s still stand in densely urbanized regions. However, demolishing them may prove less cost-effective than retrofitting to restore their original structural capacity. The widespread presence of these structures, coupled with their susceptibility to decay from weathering and poor maintenance, necessitates a comprehensive assessment of their resilience against gravitational and lateral forces, including seismic activity. Consequently, there is a pressing need to develop an analysis and verification methodology, particularly focused on seismic resilience, tailored to existing elevated tanks. These structures, distinct from conventional reinforced concrete frames, are primarily designed to withstand vertical forces, emphasizing the importance of optimizing material usage in their retrofitting efforts.
- Open Access
- 3 July 2023
- Published by Elsevier in Structures
- Vol. 55, 1595-1606
Forensic estimation of the residual capacity and imposed demand on a ruptured concrete bridge stay at the time of collapse
- 3 July 2023
- Published by Elsevier in Structures
- Vol. 55, 1595-1606
Open AccessForensic estimation of the residual capacity and imposed demand on a ruptured concrete bridge stay at the time of collapse
- 5 June 2022
- Published by Elsevier in Engineering Structures
- Vol. 265
Analytical and numerical analysis of the torsional response of the multi-cell deck of a collapsed cable-stayed bridge
- 5 June 2022
- Published by Elsevier in Engineering Structures
- Vol. 265
Analytical and numerical analysis of the torsional response of the multi-cell deck of a collapsed cable-stayed bridge
- 1 August 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 34 (4) , 04020044
Numerical Study on the Collapse of the Morandi Bridge
An innovative discontinuum-based micromodeling approach, the Applied Element Method, is used in this work to investigate explicitly potential failure mechanisms that might have contributed to the collapse of the Morandi Bridge in Genoa, Italy, which occurred on August 14, 2018. While, consistently with the findings presented in a previous contribution by the same authors, the initial trigger of the collapse mechanism was assumed as the release of one of the stays, this study investigates, through a sensitivity study, the impact that several parameters and epistemic uncertainties, including reduction of cables’ cross section (potentially induced by corrosion) and various possible configurations of both passive and active reinforcements in the main deck, have on the predicted failure mode. Then, to indicate the structural elements and details in which a potential presence of corrosion should be more carefully explored, the observed debris distribution is compared with its numerical counterparts.
- 1 August 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 34 (4) , 04020044
Numerical Study on the Collapse of the Morandi Bridge
An innovative discontinuum-based micromodeling approach, the Applied Element Method, is used in this work to investigate explicitly potential failure mechanisms that might have contributed to the collapse of the Morandi Bridge in Genoa, Italy, which occurred on August 14, 2018. While, consistently with the findings presented in a previous contribution by the same authors, the initial trigger of the collapse mechanism was assumed as the release of one of the stays, this study investigates, through a sensitivity study, the impact that several parameters and epistemic uncertainties, including reduction of cables’ cross section (potentially induced by corrosion) and various possible configurations of both passive and active reinforcements in the main deck, have on the predicted failure mode. Then, to indicate the structural elements and details in which a potential presence of corrosion should be more carefully explored, the observed debris distribution is compared with its numerical counterparts.
- 1 June 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 17 (8) , 4625-4650
A methodology for the seismic multilevel assessment of unreinforced masonry church inventories in the Groningen area
- 1 June 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 17 (8) , 4625-4650
A methodology for the seismic multilevel assessment of unreinforced masonry church inventories in the Groningen area
- 1 November 2016
- Published by Wiley in Earthquake Spectra
- Vol. 32 (4) , 2291-2315
Seismic Isolation Devices Based on Sliding between Surfaces with Variable Friction Coefficient
Base isolators are effective tools to favor a high level of building performance under lateral load, providing protection to both structural and nonstructural elements. In this context, this paper discusses the possibility of employing materials with different frictional properties to enhance the response of flat and curved‐surface base isolators. Two innovative devices, referred to as “BowTie” and “BowC,” are introduced and discussed in some detail. A series of nonlinear time history analyses are then conducted using a customized computer program and considering a number of case study structures, designed applying a displacement‐based approach. The results of the analyses are used to discuss the key differences between variable friction and constant friction sliding isolation devices. It is shown that the newly proposed isolators may represent an improvement on classic base‐isolation solutions, in light of their higher energy absorption capacity, which contributes to significantly enhance their performance.
- 1 November 2016
- Published by Wiley in Earthquake Spectra
- Vol. 32 (4) , 2291-2315
Seismic Isolation Devices Based on Sliding between Surfaces with Variable Friction Coefficient
Base isolators are effective tools to favor a high level of building performance under lateral load, providing protection to both structural and nonstructural elements. In this context, this paper discusses the possibility of employing materials with different frictional properties to enhance the response of flat and curved‐surface base isolators. Two innovative devices, referred to as “BowTie” and “BowC,” are introduced and discussed in some detail. A series of nonlinear time history analyses are then conducted using a customized computer program and considering a number of case study structures, designed applying a displacement‐based approach. The results of the analyses are used to discuss the key differences between variable friction and constant friction sliding isolation devices. It is shown that the newly proposed isolators may represent an improvement on classic base‐isolation solutions, in light of their higher energy absorption capacity, which contributes to significantly enhance their performance.