Michael Callihan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael Callihan has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Lisa Adams Wolf
University of Massachusetts‐Amherst Amherst Massachusetts USA
6 shared publications - Edward Sazonov
The University of Alabama
3 shared publications - Nathan Jeong
Department of Electrical and Computer Engineering, The University of Alabama, Tuscaloosa, AL, USA
3 shared publications - Paul R. Clark
University of Louisville School of Nursing, 555 S. Floyd Street, Louisville, KY, United States
3 shared publications - Zachary Choffin
The University of Alabama
3 shared publications Cydne Perhats
2 shared publications
Latest Publications
- 4 November 2026
- Published by Elsevier in Journal of Emergency Nursing
- Vol. 52 (6) , 1346-1348
Approaching Emergency Nursing as an Industrial Athlete
- 4 November 2026
- Published by Elsevier in Journal of Emergency Nursing
- Vol. 52 (6) , 1346-1348
Approaching Emergency Nursing as an Industrial Athlete
- 9 September 2025
- Published by Elsevier in Journal of Emergency Nursing
- Vol. 52 (1) , 143-157
Perceived Relationships Between Emergency Department Staffing Patterns and Missed Care, Missed Decompensation, and Delays in Care
- 9 September 2025
- Published by Elsevier in Journal of Emergency Nursing
- Vol. 52 (1) , 143-157
Perceived Relationships Between Emergency Department Staffing Patterns and Missed Care, Missed Decompensation, and Delays in Care
- 2 September 2024
- Published by SAGE Publications in Workplace Health & Safety
- Vol. 72 (12) , 520-527
Reliability of Wearable Technology to Monitor Core Temperature Among Helicopter-Based EMS Crews
Background: Excessive heat stress led to more than 400 deaths in the United States from 2011 to 2021. Common methods for heat injury prevention revolve around measurements of the environment and fail to account for the unique individual response to stressors. Methods: An observational approach was utilized with nine helicopter-based emergency medical services personnel during emergency flights to compare core temperature readings obtained from an ingestible temperature monitoring pill and the estimated core temperature reading of the Slate Safety Band V2 wearable device. Comparison of data was conducted within Microsoft Excel programming to determine the mean square error (MSE), root mean square error (RMSE), mean absolute error (MAE), mean biased error (MBE), and Bland–Altman plot development. Findings: A significant bias ( t = 17.58, p < .001) toward the Slate Safety device reading higher with an average difference of −0.48°C (−0.86°F) was found, meaning the average temperature reading is 0.48°C (−0.86°F) higher with the Slate Safety device. A significant correlation of .26 ( p < .001) was noted between the ingestible pill and the wearable device with a 95% confidence interval of 0.23 to 0.29. Aggregate core temperature data demonstrated an MSE of 0.43, an RMSE of 0.65, an MAE of 0.54, and an MBE of −0.48. Conclusions/Application to Practice: The ability to monitor the physiological parameters of a worker remotely adds safety tools relative to the risks of heat stress. The slightly higher reading associated with the Slate Safety wearable device provides an added safety margin to protect our workers.
- 2 September 2024
- Published by SAGE Publications in Workplace Health & Safety
- Vol. 72 (12) , 520-527
Reliability of Wearable Technology to Monitor Core Temperature Among Helicopter-Based EMS Crews
Background: Excessive heat stress led to more than 400 deaths in the United States from 2011 to 2021. Common methods for heat injury prevention revolve around measurements of the environment and fail to account for the unique individual response to stressors. Methods: An observational approach was utilized with nine helicopter-based emergency medical services personnel during emergency flights to compare core temperature readings obtained from an ingestible temperature monitoring pill and the estimated core temperature reading of the Slate Safety Band V2 wearable device. Comparison of data was conducted within Microsoft Excel programming to determine the mean square error (MSE), root mean square error (RMSE), mean absolute error (MAE), mean biased error (MBE), and Bland–Altman plot development. Findings: A significant bias ( t = 17.58, p < .001) toward the Slate Safety device reading higher with an average difference of −0.48°C (−0.86°F) was found, meaning the average temperature reading is 0.48°C (−0.86°F) higher with the Slate Safety device. A significant correlation of .26 ( p < .001) was noted between the ingestible pill and the wearable device with a 95% confidence interval of 0.23 to 0.29. Aggregate core temperature data demonstrated an MSE of 0.43, an RMSE of 0.65, an MAE of 0.54, and an MBE of −0.48. Conclusions/Application to Practice: The ability to monitor the physiological parameters of a worker remotely adds safety tools relative to the risks of heat stress. The slightly higher reading associated with the Slate Safety wearable device provides an added safety margin to protect our workers.
- 1 July 2024
- Published by Elsevier in Journal of Emergency Nursing
- Vol. 50 (4) , 499-502
Translation of Research to Practice
- 1 July 2024
- Published by Elsevier in Journal of Emergency Nursing
- Vol. 50 (4) , 499-502
Translation of Research to Practice
- 2 February 2024
- Published by Elsevier in Journal of Emergency Nursing
- Vol. 50 (5) , 651-659
Save Your Back: Comparison of the Compressive Force on the Lower Back Based on Differences in the Training Techniques
- 2 February 2024
- Published by Elsevier in Journal of Emergency Nursing
- Vol. 50 (5) , 651-659
Save Your Back: Comparison of the Compressive Force on the Lower Back Based on Differences in the Training Techniques
- Open Access
Proof of Concept Testing of Safe Patient Handling Intervention Using Wearable Sensor Technology
Background: Healthcare workers make up one of the occupations in the United States that experience the most musculoskeletal injuries. These injuries are often related to the movement and repositioning of patients. Despite previous injury prevention attempts, injury rates remain at an unsustainable level. The purpose of this proof-of-concept study is to provide preliminary testing of the impact of a lifting intervention on common biomechanical risk factors for injury during high-risk patient movements.; Methods: A before-and-after (quasi-experimental) design was utilized to compare biomechanical risk factors before and after a lifting intervention. Kinematic data were collected using the Xsens motion capture system, while muscle activations were collected with the Delsys Trigno EMG system. Results: Improvements were noted in the lever arm distance, trunk velocity, and muscle activations during the movements following the intervention; Conclusions: The contextual lifting intervention shows a positive impact on the biomechanical risk factors for musculoskeletal injury among healthcare workers without increasing the biomechanical risk. A larger, prospective study is needed to determine the intervention’s ability to reduce injuries among healthcare workers.
Open AccessProof of Concept Testing of Safe Patient Handling Intervention Using Wearable Sensor Technology
Background: Healthcare workers make up one of the occupations in the United States that experience the most musculoskeletal injuries. These injuries are often related to the movement and repositioning of patients. Despite previous injury prevention attempts, injury rates remain at an unsustainable level. The purpose of this proof-of-concept study is to provide preliminary testing of the impact of a lifting intervention on common biomechanical risk factors for injury during high-risk patient movements.; Methods: A before-and-after (quasi-experimental) design was utilized to compare biomechanical risk factors before and after a lifting intervention. Kinematic data were collected using the Xsens motion capture system, while muscle activations were collected with the Delsys Trigno EMG system. Results: Improvements were noted in the lever arm distance, trunk velocity, and muscle activations during the movements following the intervention; Conclusions: The contextual lifting intervention shows a positive impact on the biomechanical risk factors for musculoskeletal injury among healthcare workers without increasing the biomechanical risk. A larger, prospective study is needed to determine the intervention’s ability to reduce injuries among healthcare workers.
- Open Access
Comparison of Slate Safety Wearable Device to Ingestible Pill and Wearable Heart Rate Monitor
Background: With the increase in concern for deaths and illness related to the increase in temperature globally, there is a growing need for real-time monitoring of workers for heat stress indicators. The purpose of this study was to determine the usability of the Slate Safety (SS) wearable physiological monitoring system. Methods: Twenty nurses performed a common task in a moderate or hot environment while wearing the SS device, the Polar 10 monitor, and having taken the e-Celsius ingestible pill. Data from each device was compared for correlation and accuracy. Results: High correlation was determined between the SS wearable device and the Polar 10 system (0.926) and the ingestible pill (0.595). The SS was comfortable to wear and easily monitored multiple participants from a distance. Conclusions: The Slate Safety wearable device demonstrated accuracy in measuring core temperature and heart rate while not restricting the motion of the worker, and provided a remote monitoring platform for physiological parameters.
Open AccessComparison of Slate Safety Wearable Device to Ingestible Pill and Wearable Heart Rate Monitor
Background: With the increase in concern for deaths and illness related to the increase in temperature globally, there is a growing need for real-time monitoring of workers for heat stress indicators. The purpose of this study was to determine the usability of the Slate Safety (SS) wearable physiological monitoring system. Methods: Twenty nurses performed a common task in a moderate or hot environment while wearing the SS device, the Polar 10 monitor, and having taken the e-Celsius ingestible pill. Data from each device was compared for correlation and accuracy. Results: High correlation was determined between the SS wearable device and the Polar 10 system (0.926) and the ingestible pill (0.595). The SS was comfortable to wear and easily monitored multiple participants from a distance. Conclusions: The Slate Safety wearable device demonstrated accuracy in measuring core temperature and heart rate while not restricting the motion of the worker, and provided a remote monitoring platform for physiological parameters.
- Open Access
Lower Body Joint Angle Prediction Using Machine Learning and Applied Biomechanical Inverse Dynamics
Extreme angles in lower body joints may adversely increase the risk of injury to joints. These injuries are common in the workplace and cause persistent pain and significant financial losses to people and companies. The purpose of this study was to predict lower body joint angles from the ankle to the lumbosacral joint (L5S1) by measuring plantar pressures in shoes. Joint angle prediction was aided by a designed footwear sensor consisting of six force-sensing resistors (FSR) and a microcontroller fitted with Bluetooth LE sensors. An Xsens motion capture system was utilized as a ground truth validation measuring 3D joint angles. Thirty-seven human subjects were tested squatting in an IRB-approved study. The Gaussian Process Regression (GPR) linear regression algorithm was used to create a progressive model that predicted the angles of ankle, knee, hip, and L5S1. The footwear sensor showed a promising root mean square error (RMSE) for each joint. The L5S1 angle was predicted to be RMSE of 0.21° for the X-axis and 0.22° for the Y-axis, respectively. This result confirmed that the proposed plantar sensor system had the capability to predict and monitor lower body joint angles for potential injury prevention and training of occupational workers.
Open AccessLower Body Joint Angle Prediction Using Machine Learning and Applied Biomechanical Inverse Dynamics
Extreme angles in lower body joints may adversely increase the risk of injury to joints. These injuries are common in the workplace and cause persistent pain and significant financial losses to people and companies. The purpose of this study was to predict lower body joint angles from the ankle to the lumbosacral joint (L5S1) by measuring plantar pressures in shoes. Joint angle prediction was aided by a designed footwear sensor consisting of six force-sensing resistors (FSR) and a microcontroller fitted with Bluetooth LE sensors. An Xsens motion capture system was utilized as a ground truth validation measuring 3D joint angles. Thirty-seven human subjects were tested squatting in an IRB-approved study. The Gaussian Process Regression (GPR) linear regression algorithm was used to create a progressive model that predicted the angles of ankle, knee, hip, and L5S1. The footwear sensor showed a promising root mean square error (RMSE) for each joint. The L5S1 angle was predicted to be RMSE of 0.21° for the X-axis and 0.22° for the Y-axis, respectively. This result confirmed that the proposed plantar sensor system had the capability to predict and monitor lower body joint angles for potential injury prevention and training of occupational workers.
- 24 December 2022
- Published by Elsevier in Journal of Emergency Nursing
- Vol. 49 (2) , 222-235
Determining Clinical Judgment Among Emergency Nurses During a Complex Simulation
- 24 December 2022
- Published by Elsevier in Journal of Emergency Nursing
- Vol. 49 (2) , 222-235
Determining Clinical Judgment Among Emergency Nurses During a Complex Simulation