Moises Coll Rivas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Moises Coll Rivas has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Albert Jiménez Obach
Hospital de Mataro, Mataro, Barcelona, Spain
1 shared publicationAlejandro Allepuz
Agency for Health Quality and Assessment of Catalonia (Agència de Qualitat i Avaluació Sanitàries de Catalunya [AQuAS]), Barcelona, Spain
1 shared publicationArt Sedrakyan
Weill Cornell Medical College, 402 East 67th Street, New York, NY 10065
1 shared publication- Barbara Bordini
Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
1 shared publication Elizabeth Paxton
Surgical Outcomes & Analysis Department, Kaiser Permanente, 8954 Rio San Diego Drive, Suite 406, San Diego, CA 92108
1 shared publication- Eulogio Pleguezuelos
Physical Medicine and Rehabilitation Department, Hospital de Mataró, 08304 Barcelona, Spain
1 shared publication
Latest Publications
- 1 July 2016
- Published by Elsevier in Value in Health
- Vol. 19 (5) , 680-687
Predicting the Burden of Revision Knee Arthroplasty: Simulation of a 20-Year Horizon
- 1 July 2016
- Published by Elsevier in Value in Health
- Vol. 19 (5) , 680-687
Predicting the Burden of Revision Knee Arthroplasty: Simulation of a 20-Year Horizon
- 17 December 2014
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 96 (Supplement) , 25-33
Distributed Analysis of Hip Implants Using Six National and Regional Registries: Comparing Metal-on-Metal with Metal-on-Highly Cross-Linked Polyethylene Bearings in Cementless Total Hip Arthroplasty in Young Patients
The regulation of medical devices has attracted controversy recently because of problems related to metal-on-metal hip implants. There is growing evidence that metal-on-metal implants fail early and cause local and systemic complications. However, the failure associated with metal-on-metal head size is not consistently documented and needs to be communicated to patients and surgeons. The purpose of this study is to compare implant survival of metal on metal with that of metal on highly cross-linked polyethylene. Using a distributed health data network, primary total hip arthroplasties were identified from six national and regional total joint arthroplasty registries (2001 to 2010). Inclusion criteria were patient age of forty-five to sixty-four years, cementless total hip arthroplasties, primary osteoarthritis diagnosis, and exclusion of the well-known outlier implant ASR (articular surface replacement). The primary outcome was revision for any reason. A meta-analysis of survival probabilities was performed with use of a fixed-effects model. Metal-on-metal implants with a large head size of >36 mm were compared with metal-on-highly cross-linked polyethylene implants. Metal-on-metal implants with a large head size of >36 mm were used in 5172 hips and metal-on-highly cross-linked polyethylene implants were used in 14,372 hips. Metal-on-metal total hip replacements with a large head size of >36 mm had an increased risk of revision compared with metal-on-highly cross-linked polyethylene total hip replacements with more than two years of follow-up, with no difference during the first two years after implantation. The results of the hazard ratios (and 95% confidence intervals) from the multivariable model at various durations of follow-up were 0.95 (0.74 to 1.23) at zero to two years (p = 0.698), 1.42 (1.16 to 1.75) at more than two years to four years (p = 0.001), 1.78 (1.45 to 2.19) at more than four years to six years (p < 0.001), and 2.15 (1.63 to 2.83) at more than six years to seven years (p < 0.001). We conducted a comparison of large-head-size, metal-on-metal implants and metal-on-highly cross-linked polyethylene implants in younger patients with uncemented fixation. We found consistent and strong evidence worldwide that large-head-size, metal-on-metal implants were associated with increased risk of revision after two years compared with metal-on-highly cross-linked polyethylene implants, with the effect becoming more pronounced over time.
- 17 December 2014
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 96 (Supplement) , 25-33
Distributed Analysis of Hip Implants Using Six National and Regional Registries: Comparing Metal-on-Metal with Metal-on-Highly Cross-Linked Polyethylene Bearings in Cementless Total Hip Arthroplasty in Young Patients
The regulation of medical devices has attracted controversy recently because of problems related to metal-on-metal hip implants. There is growing evidence that metal-on-metal implants fail early and cause local and systemic complications. However, the failure associated with metal-on-metal head size is not consistently documented and needs to be communicated to patients and surgeons. The purpose of this study is to compare implant survival of metal on metal with that of metal on highly cross-linked polyethylene. Using a distributed health data network, primary total hip arthroplasties were identified from six national and regional total joint arthroplasty registries (2001 to 2010). Inclusion criteria were patient age of forty-five to sixty-four years, cementless total hip arthroplasties, primary osteoarthritis diagnosis, and exclusion of the well-known outlier implant ASR (articular surface replacement). The primary outcome was revision for any reason. A meta-analysis of survival probabilities was performed with use of a fixed-effects model. Metal-on-metal implants with a large head size of >36 mm were compared with metal-on-highly cross-linked polyethylene implants. Metal-on-metal implants with a large head size of >36 mm were used in 5172 hips and metal-on-highly cross-linked polyethylene implants were used in 14,372 hips. Metal-on-metal total hip replacements with a large head size of >36 mm had an increased risk of revision compared with metal-on-highly cross-linked polyethylene total hip replacements with more than two years of follow-up, with no difference during the first two years after implantation. The results of the hazard ratios (and 95% confidence intervals) from the multivariable model at various durations of follow-up were 0.95 (0.74 to 1.23) at zero to two years (p = 0.698), 1.42 (1.16 to 1.75) at more than two years to four years (p = 0.001), 1.78 (1.45 to 2.19) at more than four years to six years (p < 0.001), and 2.15 (1.63 to 2.83) at more than six years to seven years (p < 0.001). We conducted a comparison of large-head-size, metal-on-metal implants and metal-on-highly cross-linked polyethylene implants in younger patients with uncemented fixation. We found consistent and strong evidence worldwide that large-head-size, metal-on-metal implants were associated with increased risk of revision after two years compared with metal-on-highly cross-linked polyethylene implants, with the effect becoming more pronounced over time.
- 26 February 2013
- Published by SAGE Publications in The International Journal of Lower Extremity Wounds
- Vol. 12 (1) , 39-43
Total Hip Replacement in an Ipsilateral Above-the-Knee Amputation
In this article, we present a case report of a 62-year-old patient who previously underwent an above-the-knee amputation for vascular disease and we performed a total hip replacement on him because of hip osteoarthritis. As the only postoperative complication, the patient developed a methicillin-resistant Staphylococcus aureus surgical site infection, which was successfully treated. The surgical technique and the postoperative rehabilitation program are described in detail in an attempt to detect and face the challenges that patients with major lower limb amputations may present. The literature is reviewed and all known cases of hip replacements in amputees are presented.
- 26 February 2013
- Published by SAGE Publications in The International Journal of Lower Extremity Wounds
- Vol. 12 (1) , 39-43
Total Hip Replacement in an Ipsilateral Above-the-Knee Amputation
In this article, we present a case report of a 62-year-old patient who previously underwent an above-the-knee amputation for vascular disease and we performed a total hip replacement on him because of hip osteoarthritis. As the only postoperative complication, the patient developed a methicillin-resistant Staphylococcus aureus surgical site infection, which was successfully treated. The surgical technique and the postoperative rehabilitation program are described in detail in an attempt to detect and face the challenges that patients with major lower limb amputations may present. The literature is reviewed and all known cases of hip replacements in amputees are presented.