RCRobert Peter Cubbidge

Robert Peter Cubbidge

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Robert Peter Cubbidge has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In vivo measures of anterior scleral resistance in humans with rebound tonometry

    by Hetal D Buckhurst, Bernard Gilmartin, Andrew Lam, Robert P Cubbidge, Nicola S Logan

    Purpose: To measure regional variations in anterior scleral resistance (ASR) using a ballistic rebound tonometer (RBT) and examine whether the variations are significantly affected by ethnicity and refractive error (RE). Methods: ASR was measured using a RBT (iCare TA01) following calibration against the biomechanical properties of agarose biogels. Eight scleral regions (nasal, temporal, superior, inferior, inferior‐nasal, inferior‐temporal, superior‐nasal and superior‐temporal) were measured at locations 4mm from the limbus. Subjects were 130 young adults comprising three ethnic groups whose RE distributions [MSE (D) ± S.D.] incorporated individuals categorised as without‐myopia (NM; MSE ≥ −0.50) and with‐myopia (WM; MSE < −0.50); British‐White (BW): 26 NM + 0.52 ± 1.15D; 22 WM −3.83 ± 2.89D]; British‐South‐Asian (BSA): [9 NM + 0.49 ± 1.06D; 11 WM −5.07 ± 3.76D; Hong‐Kong‐Chinese (HKC): [11 NM + 0.39 ± 0.66D; 49 WM −4.46 ± 2.70D]. Biometric data were compiled using cycloplegic open‐field autorefraction and the Zeiss IOLMaster. Two‐ and three‐way repeated measures analysis of variances ( anova s) tested regional differences for RBT values across both refractive status and ethnicity whilst stepwise forward multiple linear regression was used as an exploratory test. Results: Significant regional variations in ASR were identified for the BW, BSA and HKC ( p < 0.001) individuals; superior‐temporal region showed the lowest levels of resistance whilst the inferior‐nasal region the highest. Compared to the BW and BSA groups, the HKC subjects displayed a significant increase in mean resistance for each respective region ( p < 0.001). With the exception of the inferior region, ethnicity was found to be the chief predictor for variation in the scleral RBT values for all other regions. Mean RE group differences were insignificant. Conclusions: The novel application of RBT to the anterior sclera confirm regional variation in ASR. Greater ASR amongst the HKC group than the BW and BSA individuals suggests that ethnic differences in anterior scleral biomechanics may exist.


  • Open Access

    Comparison between two fast threshold strategies: SPARK and SITA in normal subjects

    by Say Kiang Foo, Robert Peter Cubbidge, Rebekka Heitmar

    Background: Numerous fast threshold strategies have been developed in perimetry which use maximum likelihood approaches to estimate the threshold. A recent approach to threshold estimation has been developed estimating the threshold from a limited number of test points which further reduces examination time. This strategy, SPARK, has not been compared to the SITA strategy. The aim of this study was to compare SPARK with SITA in a normal cohort to evaluate within and between strategy agreement in threshold estimates. Methods: A total of 83 normal subjects each underwent two visual field examinations with SITA and SPARK on two separate occasions on a randomly selected eye. The eye examined and the order of strategy examined first was randomised but remained constant over the two perimetry visits. Results: Visual field examination with SPARK Precision was on average 33% faster than SITA Standard. A positive correlation between group mean sensitivities of SITA Standard and SPARK Precision (rho = 0.713, p < 0.001) was found. In total, 95% of stimulus locations were located within the 95% limits of agreement and linear regression on the differences in sensitivities showed no statistically significant proportional bias (t = 1.713, p = 0.09). Pointwise analysis showed SITA Standard had significantly larger variability for individual stimulus locations examined over two visits when compared to SPARK (t = 9.175, p < 0.001). Conclusion: The clinical examination of SPARK yields a sensitivity profile similar to SITA but in a faster examination time. The lower threshold variability of SPARK may be as a result of data smoothing in the threshold estimation process.


  • Open Access

    Retinal Vessel Oxygen Saturation Measurement Protocols and Their Agreement

    by Rebekka Heitmar, Robert P. Cubbidge

    Purpose: To assess agreement between different image sizes and analysis protocols for determination of retinal vessel oxygen saturation in the peripapillary retina of healthy individuals. Methods: Retinal oximetry measurements were acquired from 87 healthy volunteers using the IMEDOS Systems oxygen module. The peripapillary retinal vessels were assessed in a concentric annulus around the optic nerve head. Single and average vessel comparisons were made at different image field sizes of 30° and 50°. Comparisons between images obtained at 30° and 50° were made in a subset of 47 of the 87 individuals. Results: All subjects were normotensive and had normal intraocular pressures (9–16 mm Hg). Analyses of agreement between single vessel, averaged vessel, and between different size images were sought by Bland-Altman analyses, of which all yielded a low bias (Conclusions: Averaging methods yielded the best agreement; there was little difference in average arterial and venous oxygen saturation between protocols, which analyze all vessels versus the four largest vessels. The least agreement was found for single vessel measurements and comparisons between different camera angles. Translational Relevance: Standardization of image capture protocols (same image size and undertaking a vessel averaging approach for oxygenation analysis) will enhance the detection of smaller physiological changes in eye disease.


  • Open Access

    Regulation of oxygen saturation in retinal blood vessels in response to dynamic exercise

    by Rebekka Heitmar, Pravin Vekria, Robert P. Cubbidge

    Purpose: To evaluate the impact of dynamic exercise on retinal vessel oxygen saturation in healthy individuals.Methods: Twenty‐six healthy participants underwent moderate dynamic exercise (modified Master's two‐step exercise). In all subjects, intraocular pressures (IOP), systolic and diastolic blood pressures (SBP and DBP), retinal vessel calibres and retinal arterial and venous oxygen saturation were measured at baseline, immediately following exercise and 15 min postexercise.Results: Moderate dynamic exercise increased SBP and DBP immediately postexercise (SBP: 116 (±13) mmHg to 150 (±21) mmHg; p < 0.001 and DBP: 69 (±10) mmHg to 74 (±10); p < 0.001), while IOP decreased by an average of 2 mmHg (baseline: 13 (±3) mmHg)) immediately postexercise (11 (±2) mmHg). Oxygen saturation in retinal arteries remained unchanged (baseline = 93 ± 8%; immediately postexercise = 94 ± 9% and 15 min postexercise = 96 ± 8%; p = 0.069), but increased in retinal veins immediately postexercise and did not return to baseline values within 15 min postexercise (baseline = 54 ± 12%; immediately postexercise = 56 ± 15%; 15 min postexercise=57 ± 12%; p = 0.036).Conclusion: There is a mild increase in retinal venous oxygen saturation and there is a trend towards an increase in arterial saturation in otherwise healthy individuals following dynamic exercise.


  • Open Access

    Comparison of subjective and objective methods to determine the retinal arterio-venous ratio using fundus photography

    by Rebekka Heitmar, Angelos A. Kalitzeos, Sunni R. Patel, Diana Prabhu-Das, Robert P. Cubbidge


  • Open Access

    Measurement of Scleral Thickness in Humans Using Anterior Segment Optical Coherent Tomography

    by Hetal D Buckhurst, Bernard Gilmartin, Robert P Cubbidge, Nicola S Logan

    Anterior segment optical coherent tomography (AS-OCT, Visante; Zeiss) is used to examine meridional variation in anterior scleral thickness (AST) and its association with refractive error, ethnicity and gender. Scleral cross-sections of 74 individuals (28 males; 46 females; aged between 18-40 years (27.7±5.3)) were sampled twice in random order in 8 meridians: [superior (S), inferior (I), nasal (N), temporal (T), superior-temporal (ST), superior-nasal (SN), inferior-temporal (IT) and inferior-nasal (IN)]. AST was measured in 1mm anterior-to-posterior increments (designated the A-P distance) from the scleral spur (SS) over a 6mm distance. Axial length and refractive error were measured with a Zeiss IOLMaster biometer and an open-view binocular Shin-Nippon autorefractor. Intra- and inter-observer variability of AST was assessed for each of the 8 meridians. Mixed repeated measures ANOVAs tested meridional and A-P distance differences in AST with refractive error, gender and ethnicity. Only right eye data were analysed. AST (mean±SD) across all meridians and A-P distances was 725±46μm. Meridian SN was the thinnest (662±57μm) and I the thickest (806±60μm). Significant differences were found between all meridians (p<0.001), except S:ST, IT:IN, IT:N and IN:N. Significant differences between A-P distances were found except between SS and 6 mm and between 2 and 4 mm. AST measurements at 1mm (682±48 μm) were the thinnest and at 6mm (818±49 μm) the thickest (p<0.001); a significant interaction occurred between meridians and A-P distances (p<0.001). AST was significantly greater (p<0.001) in male subjects but no significant differences were found between refractive error or ethnicity. Significant variations in AST occur with regard to meridian and distance from the SS and may have utility in selecting optimum sites for pharmaceutical or surgical intervention.


  • Open Access

    Does the Swedish Interactive Threshold Algorithm (SITA) accurately map visual field loss attributed to vigabatrin?

    by Miriam L Conway, Sarah L Hosking, Haogang Zhu, Robert P Cubbidge

    Vigabatrin (VGB) is an anti-epileptic medication which has been linked to peripheral constriction of the visual field. Documenting the natural history associated with continued VGB exposure is important when making decisions about the risk and benefits associated with the treatment. Due to its speed the Swedish Interactive Threshold Algorithm (SITA) has become the algorithm of choice when carrying out Full Threshold automated static perimetry. SITA uses prior distributions of normal and glaucomatous visual field behaviour to estimate threshold sensitivity. As the abnormal model is based on glaucomatous behaviour this algorithm has not been validated for VGB recipients. We aim to assess the clinical utility of the SITA algorithm for accurately mapping VGB attributed field loss. The sample comprised one randomly selected eye of 16 patients diagnosed with epilepsy, exposed to VGB therapy. A clinical diagnosis of VGB attributed visual field loss was documented in 44% of the group. The mean age was 39.3 years ± 14.5 years and the mean deviation was -4.76 dB ±4.34 dB. Each patient was examined with the Full Threshold, SITA Standard and SITA Fast algorithm. SITA Standard was on average approximately twice as fast (7.6 minutes) and SITA Fast approximately 3 times as fast (4.7 minutes) as examinations completed using the Full Threshold algorithm (15.8 minutes). In the clinical environment, the visual field outcome with both SITA algorithms was equivalent to visual field examination using the Full Threshold algorithm in terms of visual inspection of the grey scale plots , defect area and defect severity. Our research shows that both SITA algorithms are able to accurately map visual field loss attributed to VGB. As patients diagnosed with epilepsy are often vulnerable to fatigue, the time saving offered by SITA Fast means that this algorithm has a significant advantage for use with VGB recipients.


  • The Eye and Vision

    by R.A. Armstrong, R.P. Cubbidge


  • Open Access

    Evaluation of Hemifield Sector Analysis Protocol in Multifocal Visual Evoked Potential Objective Perimetry for the Diagnosis and Early Detection of Glaucomatous Field Defects

    by Mohammad F. Mousa, Robert P. Cubbidge, Fatima Al-Mansouri, Abdulbari Bener

    Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss.


  • Open Access

    The role of hemifield sector analysis in multifocal visual evoked potential objective perimetry in the early detection of glaucomatous visual field defects

    by Abdulbari Bener, Mohamed F. Mousa, Robert P. Cubbidge, Fatima Al-Mansouri

    Objective: The purpose of this study was to examine the effectiveness of a new analysis method of mfVEP objective perimetry in the early detection of glaucomatous visual field defects compared to the gold standard technique. Methods and patients: Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes), and glaucoma suspect patients (38 eyes). All subjects underwent two standard 24-2 visual field tests: one with the Humphrey Field Analyzer and a single mfVEP test in one session. Analysis of the mfVEP results was carried out using the new analysis ­protocol: the hemifield sector analysis protocol. Results: Analysis of the mfVEP showed that the signal to noise ratio (SNR) difference between superior and inferior hemifields was statistically significant between the three groups (analysis of variance, P < 0.001 with a 95% confidence interval, 2.82, 2.89 for normal group; 2.25, 2.29 for glaucoma suspect group; 1.67, 1.73 for glaucoma group). The difference between superior and inferior hemifield sectors and hemi-rings was statistically significant in 11/11 pair of sectors and hemi-rings in the glaucoma patients group (t-test P < 0.001), statistically significant in 5/11 pairs of sectors and hemi-rings in the glaucoma suspect group (t-test P < 0.01), and only 1/11 pair was statistically significant (t-test P < 0.9). The sensitivity and specificity of the hemifield sector analysis protocol in detecting glaucoma was 97% and 86% respectively and 89% and 79% in glaucoma suspects. These results showed that the new analysis protocol was able to confirm existing visual field defects detected by standard perimetry, was able to differentiate between the three study groups with a clear distinction between normal patients and those with suspected glaucoma, and was able to detect early visual field changes not detected by standard perimetry. In addition, the distinction between normal and glaucoma patients was especially clear and significant using this analysis. Conclusion: The new hemifield sector analysis protocol used in mfVEP testing can be used to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol, it can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. The sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucomatous visual field loss. The intersector analysis protocol can detect early field changes not detected by the standard Humphrey Field Analyzer test.