Seon‐Chee Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Seon‐Chee Park has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Jin‐Min Kim
Department of Architectural Engineering, Kyung Hee University, Kyungki-do, Korea
3 shared publicationsSeung‐Geun Lee
Department of Architectural Engineering, Kyung Hee University, Kyungki-do, Korea
3 shared publicationsSeung‐Il Kim
Department of Architectural Engineering, Kyung Hee University, Kyungki-do, Korea
3 shared publicationsWon‐Kee Hong
Department of Architectural Engineering, Kyung Hee University, Kyungki-do, Korea
3 shared publicationsGyun-Taek Lim
Department of Architectural Engineering, Kyung Hee University, Yongin 446-701, Korea
2 shared publicationsHo‐Chan Lee
Department of Architectural Engineering, Kyung Hee University, Kyungki‐do, 449‐701, Korea
2 shared publications
Latest Publications
- 9 September 2011
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 21 (1) , 163-175
Investigation of the Energy Efficiency and CO2 Emission Characteristics of Pre-stressed Composite Beams
In this work, the energy efficiency and CO2 emission characteristics of a pre-stressed steel-framed reinforced concrete composite beam were investigated for application in high rise apartment buildings. The beam consisted of pre-cast and cast-in-place concrete with a structural T at the end section of the pre-cast concrete. As a result, CO2 emissions were significantly reduced by decreasing the quantity of steel. The composite beams were tested which demonstrated acceptable structural performance as flexural members. The measured flexible strengths of the pre-stressed composite beams were compared with the calculated flexural strengths based on the strain compatibility approach in the yield limit state and maximum load limit state. Good agreement between the experimental and analytical flexural capacities was observed. The application of the pre-stressed composite beams capable of enhancing energy efficiencies while decreasing CO2 emissions could provide a safe structure for a comfortable built environment and will be of great benefits to the welfare of a community as well. This work demonstrates that reduced CO2 emissions can be achieved by introducing pre-stressing in a concrete composite beam and by installing a structural T only at the end of the composite beam.
- 9 September 2011
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 21 (1) , 163-175
Investigation of the Energy Efficiency and CO2 Emission Characteristics of Pre-stressed Composite Beams
In this work, the energy efficiency and CO2 emission characteristics of a pre-stressed steel-framed reinforced concrete composite beam were investigated for application in high rise apartment buildings. The beam consisted of pre-cast and cast-in-place concrete with a structural T at the end section of the pre-cast concrete. As a result, CO2 emissions were significantly reduced by decreasing the quantity of steel. The composite beams were tested which demonstrated acceptable structural performance as flexural members. The measured flexible strengths of the pre-stressed composite beams were compared with the calculated flexural strengths based on the strain compatibility approach in the yield limit state and maximum load limit state. Good agreement between the experimental and analytical flexural capacities was observed. The application of the pre-stressed composite beams capable of enhancing energy efficiencies while decreasing CO2 emissions could provide a safe structure for a comfortable built environment and will be of great benefits to the welfare of a community as well. This work demonstrates that reduced CO2 emissions can be achieved by introducing pre-stressing in a concrete composite beam and by installing a structural T only at the end of the composite beam.
- 6 September 2011
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 21 (1) , 176-183
Evaluation of the Energy Efficiencies of Pre-cast Composite Columns
Columns manufactured with pre-cast concrete could reduce construction waste and CO2 emissions by reducing the use of temporary materials such as formwork. In this paper, three types of connection methods are introduced. The structural performance of pre-cast composite columns connected to beams was investigated for the column connection. Multi-story pre-cast composite columns could significantly reduce the construction time, resulting in a decrease in CO2 emissions. This paper reports the analysis of the compression and bending of a two-story column so as to verify the structural performances of pre-cast composite columns to provide adequate integrity to ensure a safe environment for building accommodation. In addition, a steel-framed column and a steel-framed reinforced concrete (SRC) column configured to feature the same compression performance as a pre-cast composite column were designed on the basis of the analysis results. The CO2 emissions and energy efficiency of the composite columns were compared with those of conventional steel and SRC columns during the design and construction phases. This paper also presents new composite columns providing efficient energy consumption with reduced CO2 emissions for a more environmentally conscientious construction of buildings.
- 6 September 2011
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 21 (1) , 176-183
Evaluation of the Energy Efficiencies of Pre-cast Composite Columns
Columns manufactured with pre-cast concrete could reduce construction waste and CO2 emissions by reducing the use of temporary materials such as formwork. In this paper, three types of connection methods are introduced. The structural performance of pre-cast composite columns connected to beams was investigated for the column connection. Multi-story pre-cast composite columns could significantly reduce the construction time, resulting in a decrease in CO2 emissions. This paper reports the analysis of the compression and bending of a two-story column so as to verify the structural performances of pre-cast composite columns to provide adequate integrity to ensure a safe environment for building accommodation. In addition, a steel-framed column and a steel-framed reinforced concrete (SRC) column configured to feature the same compression performance as a pre-cast composite column were designed on the basis of the analysis results. The CO2 emissions and energy efficiency of the composite columns were compared with those of conventional steel and SRC columns during the design and construction phases. This paper also presents new composite columns providing efficient energy consumption with reduced CO2 emissions for a more environmentally conscientious construction of buildings.
- 20 July 2010
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 19 (5) , 497-517
Experimental study of reinforced concrete beams strengthened with a GFRP channel and CFRP sheets
- 20 July 2010
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 19 (5) , 497-517
Experimental study of reinforced concrete beams strengthened with a GFRP channel and CFRP sheets
- 25 March 2009
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 19 (6) , 679-706
Composite beam composed of steel and precast concrete (modularized hybrid system). Part III: Application for a 19‐storey building
The authors present an experimental and analytical investigation of the modularized hybrid system (MHS) that utilizes the composite structure described in previous studies, that of a wide steel flange and precast concrete. The objective of this paper was to introduce the application of the MHS structural system to a high‐rise building in which one additional floor was added while the overall building height was maintained. The 68‐m‐tall, 18‐storey steel building was redesigned to a 19‐storey building using the composite beams, which combine the merits of ductile steel and concrete components to withstand external loading while reducing floor height. The bottom flange of the steel beam is reinforced with concrete at a manufacturing plant, eliminating the use of temporary pour forms. The erection process of the composite beams is identical to that of traditional steel construction. This paper also describes more than 30 potential applications of high‐rise composite construction using the MHS frames. The advantages of the MHS are presented in terms of reduced structural steel tonnage and shortened construction schedules. Copyright © 2009 John Wiley & Sons, Ltd.
- 25 March 2009
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 19 (6) , 679-706
Composite beam composed of steel and precast concrete (modularized hybrid system). Part III: Application for a 19‐storey building
The authors present an experimental and analytical investigation of the modularized hybrid system (MHS) that utilizes the composite structure described in previous studies, that of a wide steel flange and precast concrete. The objective of this paper was to introduce the application of the MHS structural system to a high‐rise building in which one additional floor was added while the overall building height was maintained. The 68‐m‐tall, 18‐storey steel building was redesigned to a 19‐storey building using the composite beams, which combine the merits of ductile steel and concrete components to withstand external loading while reducing floor height. The bottom flange of the steel beam is reinforced with concrete at a manufacturing plant, eliminating the use of temporary pour forms. The erection process of the composite beams is identical to that of traditional steel construction. This paper also describes more than 30 potential applications of high‐rise composite construction using the MHS frames. The advantages of the MHS are presented in terms of reduced structural steel tonnage and shortened construction schedules. Copyright © 2009 John Wiley & Sons, Ltd.
- 13 November 2008
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 19 (3) , 275-289
Composite beam composed of steel and precast concrete (Modularized Hybrid System, MHS). Part I: experimental investigation
An experimental investigation of composite beams composed of wide flange steel and precast concrete is presented. The bottom flange of the steel section is encased in precast concrete. Utilizing the merits of both steel and concrete material, the size of the steel beams can be reduced without sacrificing performance. The bottom flange of the steel beam is reinforced with concrete at a manufacturing plant, eliminating the use of temporary pour forms. The composite beams were tested to investigate how the size of the wide flange steel and how the top and bottom reinforcements influence the behaviour of the beams. Flexural load carrying capacity, load displacement relationships and failure modes were examined. The test specimens were T‐shaped composite beams with slabs, each measuring 10‐m long. The flexural moment strength of all of the composite beams—at both the yield limit state and the maximum load limit state—was measured and compared with the analytical flexural capacity.The stiffness degradation, ductility and dissipating energy capabilities of the composite beams were investigated based on the hysteresis curves. The composite beams tested in this study successfully reduced both the floor height of the building and the size of the steel beams needed to meet code requirements. Copyright © 2008 John Wiley & Sons, Ltd.
- 13 November 2008
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 19 (3) , 275-289
Composite beam composed of steel and precast concrete (Modularized Hybrid System, MHS). Part I: experimental investigation
An experimental investigation of composite beams composed of wide flange steel and precast concrete is presented. The bottom flange of the steel section is encased in precast concrete. Utilizing the merits of both steel and concrete material, the size of the steel beams can be reduced without sacrificing performance. The bottom flange of the steel beam is reinforced with concrete at a manufacturing plant, eliminating the use of temporary pour forms. The composite beams were tested to investigate how the size of the wide flange steel and how the top and bottom reinforcements influence the behaviour of the beams. Flexural load carrying capacity, load displacement relationships and failure modes were examined. The test specimens were T‐shaped composite beams with slabs, each measuring 10‐m long. The flexural moment strength of all of the composite beams—at both the yield limit state and the maximum load limit state—was measured and compared with the analytical flexural capacity.The stiffness degradation, ductility and dissipating energy capabilities of the composite beams were investigated based on the hysteresis curves. The composite beams tested in this study successfully reduced both the floor height of the building and the size of the steel beams needed to meet code requirements. Copyright © 2008 John Wiley & Sons, Ltd.