Tiago Franco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tiago Franco has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Paulo Alves
Research Centre in Digitalization and Intelligent Robotics (CeDRI), Instituto Politécnico de Bragança, 5300-253 Bragança, Portugal
7 shared publications - Pedro Rangel Henriques
University of Minho
5 shared publications - Maria João Varanda Pereira
Polytechnic Institute of Bragança
4 shared publications - Leonardo Sestrem
Polytechnic Institute of Bragança
3 shared publications - Paulo Leitão
Research Center in Digitalization and Intelligent Robotics (CeDRI), Instituto Politécnico de Bragança, Campus de Santa Apolónia, 5300-253 Bragança, Portugal
3 shared publications - Alfredo Silva
INOVA+, 4450-309 Porto, Portugal
2 shared publications
Latest Publications
- Open Access
- 15 April 2025
- Published by Elsevier in Biomedical Engineering Advances
- Vol. 9
Decision support systems for lower limb rehabilitation using electrical stimulation—A review
- 15 April 2025
- Published by Elsevier in Biomedical Engineering Advances
- Vol. 9
Open AccessDecision support systems for lower limb rehabilitation using electrical stimulation—A review
- 27 February 2025
- Published by Springer Nature
- p. 588-592
A Preliminary Comparative Study of Knee Kinematics and Dynamics with NanoStim and Motion Capture Systems
- 27 February 2025
- Published by Springer Nature
- p. 588-592
A Preliminary Comparative Study of Knee Kinematics and Dynamics with NanoStim and Motion Capture Systems
- Open Access
- 3 October 2024
- Published by International Association of Online Engineering (IAOE) in International Journal of Online and Biomedical Engineering (iJOE)
- Vol. 20 (13) , 60-83
Biofeedback-Based Method for Real-Time Fatigue Monitoring of Knee
This paper introduces and implements a method to monitor muscle fatigue in real-time using a wearable biofeedback system to improve muscle rehabilitation treatments. The biofeedback system consists of an electromyography (EMG) sensor to capture muscle activity and two motion sensors to track knee angles. The proposed method for monitoring muscle fatigue involves three steps: (1) recognition of the movement phases during the knee extension exercise; (2) clipping of the EMG signal and calculation of fatigue-related metrics; and (3) normalization of metrics through a calibration process. An experimental session was performed with 10 healthy subjects performing 50 repetitions of the knee extension exercise. Processed data revealed changes in fatigue-related metrics, which align with existing literature. A comparison was also made between real-time and computer processing using raw data. While minor differences were noted between the two processing methods, the mobile app closely mirrored the trajectory of processed data in the cloud, ensuring reliability and consistency. This study advances remote muscle rehabilitation by quantifying muscle fatigue during treatment sessions. Thus, health professionals can tailor treatment plans based on individual patient characteristics, optimizing treatment duration, and reducing injury risk.
- 3 October 2024
- Published by International Association of Online Engineering (IAOE) in International Journal of Online and Biomedical Engineering (iJOE)
- Vol. 20 (13) , 60-83
Open AccessBiofeedback-Based Method for Real-Time Fatigue Monitoring of Knee
This paper introduces and implements a method to monitor muscle fatigue in real-time using a wearable biofeedback system to improve muscle rehabilitation treatments. The biofeedback system consists of an electromyography (EMG) sensor to capture muscle activity and two motion sensors to track knee angles. The proposed method for monitoring muscle fatigue involves three steps: (1) recognition of the movement phases during the knee extension exercise; (2) clipping of the EMG signal and calculation of fatigue-related metrics; and (3) normalization of metrics through a calibration process. An experimental session was performed with 10 healthy subjects performing 50 repetitions of the knee extension exercise. Processed data revealed changes in fatigue-related metrics, which align with existing literature. A comparison was also made between real-time and computer processing using raw data. While minor differences were noted between the two processing methods, the mobile app closely mirrored the trajectory of processed data in the cloud, ensuring reliability and consistency. This study advances remote muscle rehabilitation by quantifying muscle fatigue during treatment sessions. Thus, health professionals can tailor treatment plans based on individual patient characteristics, optimizing treatment duration, and reducing injury risk.
- 13 December 2022
- Published by Springer Nature
- p. 111-120
Titanium Based Dry Electrodes for Biostimulation and Data Acquisition
- 13 December 2022
- Published by Springer Nature
- p. 111-120
Titanium Based Dry Electrodes for Biostimulation and Data Acquisition
- Open Access
Motion Sensors for Knee Angle Recognition in Muscle Rehabilitation Solutions
The progressive loss of functional capacity due to aging is a serious problem that can compromise human locomotion capacity, requiring the help of an assistant and reducing independence. The NanoStim project aims to develop a system capable of performing treatment with electrostimulation at the patient’s home, reducing the number of consultations. The knee angle is one of the essential attributes in this context, helping understand the patient’s movement during the treatment session. This article presents a wearable system that recognizes the knee angle through IMU sensors. The hardware chosen for the wearables are low cost, including an ESP32 microcontroller and an MPU-6050 sensor. However, this hardware impairs signal accuracy in the multitasking environment expected in rehabilitation treatment. Three optimization filters with algorithmic complexity were tested to improve the signal’s noise. The complementary filter obtained the best result, presenting an average error of 0.6 degrees and an improvement of 77% in MSE. Furthermore, an interface in the mobile app was developed to respond immediately to the recognized movement. The systems were tested with volunteers in a real environment and could successfully measure the movement performed. In the future, it is planned to use the recognized angle with the electromyography sensor.Open AccessMotion Sensors for Knee Angle Recognition in Muscle Rehabilitation Solutions
The progressive loss of functional capacity due to aging is a serious problem that can compromise human locomotion capacity, requiring the help of an assistant and reducing independence. The NanoStim project aims to develop a system capable of performing treatment with electrostimulation at the patient’s home, reducing the number of consultations. The knee angle is one of the essential attributes in this context, helping understand the patient’s movement during the treatment session. This article presents a wearable system that recognizes the knee angle through IMU sensors. The hardware chosen for the wearables are low cost, including an ESP32 microcontroller and an MPU-6050 sensor. However, this hardware impairs signal accuracy in the multitasking environment expected in rehabilitation treatment. Three optimization filters with algorithmic complexity were tested to improve the signal’s noise. The complementary filter obtained the best result, presenting an average error of 0.6 degrees and an improvement of 77% in MSE. Furthermore, an interface in the mobile app was developed to respond immediately to the recognized movement. The systems were tested with volunteers in a real environment and could successfully measure the movement performed. In the future, it is planned to use the recognized angle with the electromyography sensor. - 22 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Decision Support System for NMES Treatments : A solution design
The preservation of functional capacity in old age is associated with a more active and dignified life. Maintaining this capacity is not a trivial task; several diseases can make it difficult to practice regular physical exercises or make it unfeasible, such as knee osteoarthritis. Neuromuscular electrical stimulation (NMES) is a treatment for muscle rehabilitation positioned as an alternative. However, it is still unclear which electrostimulation configurations can produce the most effective treatment. The literature indicates that the difference in treatment depends on the intrinsic characteristics of the patients. In this scenario, a decision support system is designed to assist physiotherapists in data analyses to create a personalized treatment. The proposed treatment relies on a wearable system with an NMES actuator and biofeedback sensors. Thus, it is expected to adapt the NMES in real-time based on unique patient characteristics, such as muscle fatigue. In addition, the system architecture is designed for the treatment session to be carried out at the patient’s home, reducing costs and providing more comfort.
- 22 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Decision Support System for NMES Treatments : A solution design
The preservation of functional capacity in old age is associated with a more active and dignified life. Maintaining this capacity is not a trivial task; several diseases can make it difficult to practice regular physical exercises or make it unfeasible, such as knee osteoarthritis. Neuromuscular electrical stimulation (NMES) is a treatment for muscle rehabilitation positioned as an alternative. However, it is still unclear which electrostimulation configurations can produce the most effective treatment. The literature indicates that the difference in treatment depends on the intrinsic characteristics of the patients. In this scenario, a decision support system is designed to assist physiotherapists in data analyses to create a personalized treatment. The proposed treatment relies on a wearable system with an NMES actuator and biofeedback sensors. Thus, it is expected to adapt the NMES in real-time based on unique patient characteristics, such as muscle fatigue. In addition, the system architecture is designed for the treatment session to be carried out at the patient’s home, reducing costs and providing more comfort.
- 11 May 2022
- Published by Springer Nature
- p. 305-315
System Architecture for Home Muscle Rehabilitation Treatment
- 11 May 2022
- Published by Springer Nature
- p. 305-315
System Architecture for Home Muscle Rehabilitation Treatment
- 1 January 2022
- Published by Springer Nature
- p. 470-485
Anomaly Detection Using Smart Shirt and Machine Learning: A Systematic Review
- 1 January 2022
- Published by Springer Nature
- p. 470-485
Anomaly Detection Using Smart Shirt and Machine Learning: A Systematic Review
- 23 April 2021
- Published by Springer Nature
- p. 207-216
Implementation of Big Data Analytics Tool in a Higher Education Institution
- 23 April 2021
- Published by Springer Nature
- p. 207-216
Implementation of Big Data Analytics Tool in a Higher Education Institution