Juan Carlos García Naranjo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Juan Carlos García Naranjo has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Bruno da Silva
Department of Electronics and Informatics, Vrije Universiteit Brussel, 1050 Brussels, Belgium
5 shared publications - Joan Lambert Cause
Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium
5 shared publications - Johan Stiens
Department of Electronics and Informatics, Vrije Universiteit Brussel, Brussels, Belgium
5 shared publications - Ángel Solé Morillo
Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium
5 shared publications - Manuel Arsenio Lores Guevara
Centro de Biofísica Médica, Universidad de Oriente
3 shared publications Alexander Sóñora-Mengana
Centro de biofísica Médica. Santiago de Cuba. Cuba
2 shared publications
Latest Publications
- Open Access
A Lightweight Hybrid Authentication and Key Agreement Protocol for Decentralized Device-to-Device Communication with Post-Quantum Confidentiality
Device-to-device (D2D) communication is expected to become a key component of 6G and IoT systems, enabling low-latency and infrastructure-independent connectivity. A major challenge is to establish secure session keys between previously unknown devices without relying on an online trusted third party, while also ensuring resilience against future quantum adversaries. This paper proposes a lightweight hybrid authentication and key agreement protocol for decentralized D2D communication. The approach combines IPFS-assisted distributed key discovery with a two-message protocol that uses post-quantum key encapsulation for long-term confidentiality, while retaining elliptic curve cryptography (ECC) for efficient real-time authentication under classical security assumptions.This design reflects the different temporal security requirements of confidentiality and authentication and provides a practical trade-off between quantum resilience and computational efficiency. The proposed scheme achieves mutual authentication under classical ECC assumptions, secure session key establishment, and resistance against common attacks, while providing post-quantum confidentiality protection against future quantum adversaries and removing the need for an online trusted third party (TTP) during protocol execution. The results demonstrate that the protocol offers a competitive and practical solution for secure decentralized D2D communication in IoT and future 6G environments.
Open AccessA Lightweight Hybrid Authentication and Key Agreement Protocol for Decentralized Device-to-Device Communication with Post-Quantum Confidentiality
Device-to-device (D2D) communication is expected to become a key component of 6G and IoT systems, enabling low-latency and infrastructure-independent connectivity. A major challenge is to establish secure session keys between previously unknown devices without relying on an online trusted third party, while also ensuring resilience against future quantum adversaries. This paper proposes a lightweight hybrid authentication and key agreement protocol for decentralized D2D communication. The approach combines IPFS-assisted distributed key discovery with a two-message protocol that uses post-quantum key encapsulation for long-term confidentiality, while retaining elliptic curve cryptography (ECC) for efficient real-time authentication under classical security assumptions.This design reflects the different temporal security requirements of confidentiality and authentication and provides a practical trade-off between quantum resilience and computational efficiency. The proposed scheme achieves mutual authentication under classical ECC assumptions, secure session key establishment, and resistance against common attacks, while providing post-quantum confidentiality protection against future quantum adversaries and removing the need for an online trusted third party (TTP) during protocol execution. The results demonstrate that the protocol offers a competitive and practical solution for secure decentralized D2D communication in IoT and future 6G environments.
- Open Access
- 29 June 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (13) , 5704
The Impact of Contact Force on Signal Quality Indices in Photoplethysmography Measurements
Photoplethysmography (PPG) is widely used to assess cardiovascular health. Yet, its effectiveness is often hindered by external factors like contact force (CF), which significantly affects the accuracy and reliability of measurements. This study investigates how variations in the CF at the index fingertips influence six signal quality indices (SQIs)—including the perfusion index, skewness, kurtosis, entropy, zero-crossing rate, and relative power—using data from 11 healthy participants. Our analysis of normalized CF values reveals that lower CF ranges (0.2 to 0.4) may be optimal for extracting information about perfusion and blood flow. However, they may not be the best range to capture all the physiological details within the PPG pulse. In contrast, higher CF ranges (0.4 to 0.6) enable capturing more complex signals that could be physiologically representative. The findings underscore the necessity of considering viscoelastic tissue properties and individual biomechanical differences, advocating for both the normalization of CF for improved cross-subject comparison and personalized CF calibration to adapt PPG devices to diverse populations. These strategies ensure measurement reliability and consistency, thereby advancing the accuracy of cardiac and vascular assessments. Our study offers guidelines for adjusting the CF levels to balance signal detail and perfusion quality, customized to meet specific analytical requirements, with direct implications for both clinical and research environments.
- 29 June 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (13) , 5704
Open AccessThe Impact of Contact Force on Signal Quality Indices in Photoplethysmography Measurements
Photoplethysmography (PPG) is widely used to assess cardiovascular health. Yet, its effectiveness is often hindered by external factors like contact force (CF), which significantly affects the accuracy and reliability of measurements. This study investigates how variations in the CF at the index fingertips influence six signal quality indices (SQIs)—including the perfusion index, skewness, kurtosis, entropy, zero-crossing rate, and relative power—using data from 11 healthy participants. Our analysis of normalized CF values reveals that lower CF ranges (0.2 to 0.4) may be optimal for extracting information about perfusion and blood flow. However, they may not be the best range to capture all the physiological details within the PPG pulse. In contrast, higher CF ranges (0.4 to 0.6) enable capturing more complex signals that could be physiologically representative. The findings underscore the necessity of considering viscoelastic tissue properties and individual biomechanical differences, advocating for both the normalization of CF for improved cross-subject comparison and personalized CF calibration to adapt PPG devices to diverse populations. These strategies ensure measurement reliability and consistency, thereby advancing the accuracy of cardiac and vascular assessments. Our study offers guidelines for adjusting the CF levels to balance signal detail and perfusion quality, customized to meet specific analytical requirements, with direct implications for both clinical and research environments.
- Open Access
Evaluating Vascular Depth-Dependent Changes in Multi-Wavelength PPG Signals Due to Contact Force
Photoplethysmography (PPG) is a non-invasive method used for cardiovascular monitoring, with multi-wavelength PPG (MW-PPG) enhancing its efficacy by using multiple wavelengths for improved assessment. This study explores how contact force (CF) variations impact MW-PPG signals. Data from 11 healthy subjects are analyzed to investigate the still understudied specific effects of CF on PPG signals. The obtained dataset includes simultaneous recording of five PPG wavelengths (470, 525, 590, 631, and 940 nm), CF, skin temperature, and the tonometric measurement derived from CF. The evolution of raw signals and the PPG DC and AC components are analyzed in relation to the increasing and decreasing faces of the CF. Findings reveal individual variability in signal responses related to skin and vasculature properties and demonstrate hysteresis and wavelength-dependent responses to CF changes. Notably, all wavelengths except 631 nm showed that the DC component of PPG signals correlates with CF trends, suggesting the potential use of this component as an indirect CF indicator. However, further validation is needed for practical application. The study underscores the importance of biomechanical properties at the measurement site and inter-individual variability and proposes the arterial pressure wave as a key factor in PPG signal formation.
Open AccessEvaluating Vascular Depth-Dependent Changes in Multi-Wavelength PPG Signals Due to Contact Force
Photoplethysmography (PPG) is a non-invasive method used for cardiovascular monitoring, with multi-wavelength PPG (MW-PPG) enhancing its efficacy by using multiple wavelengths for improved assessment. This study explores how contact force (CF) variations impact MW-PPG signals. Data from 11 healthy subjects are analyzed to investigate the still understudied specific effects of CF on PPG signals. The obtained dataset includes simultaneous recording of five PPG wavelengths (470, 525, 590, 631, and 940 nm), CF, skin temperature, and the tonometric measurement derived from CF. The evolution of raw signals and the PPG DC and AC components are analyzed in relation to the increasing and decreasing faces of the CF. Findings reveal individual variability in signal responses related to skin and vasculature properties and demonstrate hysteresis and wavelength-dependent responses to CF changes. Notably, all wavelengths except 631 nm showed that the DC component of PPG signals correlates with CF trends, suggesting the potential use of this component as an indirect CF indicator. However, further validation is needed for practical application. The study underscores the importance of biomechanical properties at the measurement site and inter-individual variability and proposes the arterial pressure wave as a key factor in PPG signal formation.
- Open Access
Anomaly Detection in Multi-Wavelength Photoplethysmography Using Lightweight Machine Learning Algorithms
Over the past few years, there has been increased interest in photoplethysmography (PPG) technology, which has revealed that, in addition to heart rate and oxygen saturation, the pulse shape of the PPG signal contains much more valuable information. Lately, the wearable market has shifted towards a multi-wavelength and multichannel approach to increase signal robustness and facilitate the extraction of other intrinsic information from the signal. This transition presents several challenges related to complexity, accuracy, and reliability of algorithms. To address these challenges, anomaly detection stages can be employed to increase the accuracy and reliability of estimated parameters. Powerful algorithms, such as lightweight machine learning (ML) algorithms, can be used for anomaly detection in multi-wavelength PPG (MW-PPG). The main contributions of this paper are (a) proposing a set of features with high information gain for anomaly detection in MW-PPG signals in the classification context, (b) assessing the impact of window size and evaluating various lightweight ML models to achieve highly accurate anomaly detection, and (c) examining the effectiveness of MW-PPG signals in detecting artifacts.
Open AccessAnomaly Detection in Multi-Wavelength Photoplethysmography Using Lightweight Machine Learning Algorithms
Over the past few years, there has been increased interest in photoplethysmography (PPG) technology, which has revealed that, in addition to heart rate and oxygen saturation, the pulse shape of the PPG signal contains much more valuable information. Lately, the wearable market has shifted towards a multi-wavelength and multichannel approach to increase signal robustness and facilitate the extraction of other intrinsic information from the signal. This transition presents several challenges related to complexity, accuracy, and reliability of algorithms. To address these challenges, anomaly detection stages can be employed to increase the accuracy and reliability of estimated parameters. Powerful algorithms, such as lightweight machine learning (ML) algorithms, can be used for anomaly detection in multi-wavelength PPG (MW-PPG). The main contributions of this paper are (a) proposing a set of features with high information gain for anomaly detection in MW-PPG signals in the classification context, (b) assessing the impact of window size and evaluating various lightweight ML models to achieve highly accurate anomaly detection, and (c) examining the effectiveness of MW-PPG signals in detecting artifacts.
- Open Access
Novel Multi-Parametric Sensor System for Comprehensive Multi-Wavelength Photoplethysmography Characterization
Photoplethysmography (PPG) is widely used to assess cardiovascular health. However, its usage and standardization are limited by the impact of variable contact force and temperature, which influence the accuracy and reliability of the measurements. Although some studies have evaluated the impact of these phenomena on signal amplitude, there is still a lack of knowledge about how these perturbations can distort the signal morphology, especially for multi-wavelength PPG (MW-PPG) measurements. This work presents a modular multi-parametric sensor system that integrates continuous and real-time acquisition of MW-PPG, contact force, and temperature signals. The implemented design solution allows for a comprehensive characterization of the effects of the variations in these phenomena on the contour of the MW-PPG signal. Furthermore, a dynamic DC cancellation circuitry was implemented to improve measurement resolution and obtain high-quality raw multi-parametric data. The accuracy of the MW-PPG signal acquisition was assessed using a synthesized reference PPG optical signal. The performance of the contact force and temperature sensors was evaluated as well. To determine the overall quality of the multi-parametric measurement, an in vivo measurement on the index finger of a volunteer was performed. The results indicate a high precision and accuracy in the measurements, wherein the capacity of the system to obtain high-resolution and low-distortion MW-PPG signals is highlighted. These findings will contribute to developing new signal-processing approaches, advancing the accuracy and robustness of PPG-based systems, and bridging existing gaps in the literature.
Open AccessNovel Multi-Parametric Sensor System for Comprehensive Multi-Wavelength Photoplethysmography Characterization
Photoplethysmography (PPG) is widely used to assess cardiovascular health. However, its usage and standardization are limited by the impact of variable contact force and temperature, which influence the accuracy and reliability of the measurements. Although some studies have evaluated the impact of these phenomena on signal amplitude, there is still a lack of knowledge about how these perturbations can distort the signal morphology, especially for multi-wavelength PPG (MW-PPG) measurements. This work presents a modular multi-parametric sensor system that integrates continuous and real-time acquisition of MW-PPG, contact force, and temperature signals. The implemented design solution allows for a comprehensive characterization of the effects of the variations in these phenomena on the contour of the MW-PPG signal. Furthermore, a dynamic DC cancellation circuitry was implemented to improve measurement resolution and obtain high-quality raw multi-parametric data. The accuracy of the MW-PPG signal acquisition was assessed using a synthesized reference PPG optical signal. The performance of the contact force and temperature sensors was evaluated as well. To determine the overall quality of the multi-parametric measurement, an in vivo measurement on the index finger of a volunteer was performed. The results indicate a high precision and accuracy in the measurements, wherein the capacity of the system to obtain high-resolution and low-distortion MW-PPG signals is highlighted. These findings will contribute to developing new signal-processing approaches, advancing the accuracy and robustness of PPG-based systems, and bridging existing gaps in the literature.
- Open Access
PPG EduKit: An Adjustable Photoplethysmography Evaluation System for Educational Activities
The grown interest in healthcare applications has made biomedical engineering one of the fastest growing disciplines in recent years. Photoplethysmography (PPG) has gained popularity in recent years due to its versatility for noninvasive monitoring of vital signs such as heart rate, respiratory rate, blood oxygen saturation and blood pressure. In this work, an adjustable PPG-based educational device called PPG EduKit, which aims to facilitate the learning of the PPG technology for a wide range of engineering and medical disciplines is proposed. Through the use of this educational platform, the PPG signal can be understood, modified and implemented along with the extraction of its relevant physiological information from a didactic, intuitive and practical way. The PPG Edukit is evaluated for the extraction of physiological parameters such as heart rate and blood oxygen level, demonstrating how its features contribute to engineering and medical students to assimilate technical concepts in electrical circuits, biomedical instrumentation, and human physiology.
Open AccessPPG EduKit: An Adjustable Photoplethysmography Evaluation System for Educational Activities
The grown interest in healthcare applications has made biomedical engineering one of the fastest growing disciplines in recent years. Photoplethysmography (PPG) has gained popularity in recent years due to its versatility for noninvasive monitoring of vital signs such as heart rate, respiratory rate, blood oxygen saturation and blood pressure. In this work, an adjustable PPG-based educational device called PPG EduKit, which aims to facilitate the learning of the PPG technology for a wide range of engineering and medical disciplines is proposed. Through the use of this educational platform, the PPG signal can be understood, modified and implemented along with the extraction of its relevant physiological information from a didactic, intuitive and practical way. The PPG Edukit is evaluated for the extraction of physiological parameters such as heart rate and blood oxygen level, demonstrating how its features contribute to engineering and medical students to assimilate technical concepts in electrical circuits, biomedical instrumentation, and human physiology.
- Open Access
- 1 November 2021
- Published by Editorial Primmate in Orange Journal
- Vol. 3 (5) , 42-52
Detección de arritmias a partir de la determinación de la frecuencia cardiaca con fotopletismografía
Las enfermedades cardiovasculares (ECV) cobran la vida de cerca de 18 millones de personas cada año, constituyendo la principal causa de muerte e incapacidad en el mundo. Entre las enfermedades cardiovasculares, las arritmias cardiacas son las más comunes. Desde hace varios años, nuevos estudios han destacado las potencialidades de la onda fotopletismográfica para detectar arritmias, superando en sencillez y reducción de costos a la electrocardiografía (ECG). En este estudio se propone un método de detección de picos sistólicos de la onda fotopletismográfica para determinar la frecuencia cardiaca y con ello establecer la presencia de taquicardia, bradicardia o asístole. El método de detección de picos sistólicos calcula la primera derivada de la señal previamente filtrada. A continuación aplica un proceso de umbralización. Finalmente, en una etapa de agrupamiento se emplea el algoritmo DBSCAN. El algoritmo de detección de picos fue evaluado en 42 señales de una base de datos internacional multiparamétrica para la estimación del RR. La evaluación del método mostró alta exactitud y precisión (0±2 ms) y una sensibilidad y valor predictivo positivo del 99 %. Estos resultados permiten determinar la frecuencia cardiaca con una exactitud y precisión de 0±1 latido por minuto. Además, este algoritmo es evaluado en clasificación de arritmias utilizando 155 señales de la base de datos del PhysioNet/Computing in Cardiology Challenge del 2015. Para esta evaluación el algoritmo mostró resultados aceptables en la detección de asístole, bradicardia y taquicardia. La sensibilidad y el valor predictivo positivo fue del 79% y 88% para asístole, 74% y 64% para bradicardia y, 80% y 99% para taquicardia respectivamente. La efectividad del método puede afectarse en registros de señales con grandes variaciones de amplitud y/o con relaciones señal-ruido (SNR) bajas. No obstante, los resultados en estas condiciones son aceptables y son muy buenos en señales de alto SNR.
- 1 November 2021
- Published by Editorial Primmate in Orange Journal
- Vol. 3 (5) , 42-52
Open AccessDetección de arritmias a partir de la determinación de la frecuencia cardiaca con fotopletismografía
Las enfermedades cardiovasculares (ECV) cobran la vida de cerca de 18 millones de personas cada año, constituyendo la principal causa de muerte e incapacidad en el mundo. Entre las enfermedades cardiovasculares, las arritmias cardiacas son las más comunes. Desde hace varios años, nuevos estudios han destacado las potencialidades de la onda fotopletismográfica para detectar arritmias, superando en sencillez y reducción de costos a la electrocardiografía (ECG). En este estudio se propone un método de detección de picos sistólicos de la onda fotopletismográfica para determinar la frecuencia cardiaca y con ello establecer la presencia de taquicardia, bradicardia o asístole. El método de detección de picos sistólicos calcula la primera derivada de la señal previamente filtrada. A continuación aplica un proceso de umbralización. Finalmente, en una etapa de agrupamiento se emplea el algoritmo DBSCAN. El algoritmo de detección de picos fue evaluado en 42 señales de una base de datos internacional multiparamétrica para la estimación del RR. La evaluación del método mostró alta exactitud y precisión (0±2 ms) y una sensibilidad y valor predictivo positivo del 99 %. Estos resultados permiten determinar la frecuencia cardiaca con una exactitud y precisión de 0±1 latido por minuto. Además, este algoritmo es evaluado en clasificación de arritmias utilizando 155 señales de la base de datos del PhysioNet/Computing in Cardiology Challenge del 2015. Para esta evaluación el algoritmo mostró resultados aceptables en la detección de asístole, bradicardia y taquicardia. La sensibilidad y el valor predictivo positivo fue del 79% y 88% para asístole, 74% y 64% para bradicardia y, 80% y 99% para taquicardia respectivamente. La efectividad del método puede afectarse en registros de señales con grandes variaciones de amplitud y/o con relaciones señal-ruido (SNR) bajas. No obstante, los resultados en estas condiciones son aceptables y son muy buenos en señales de alto SNR.
- Open Access
- 1 January 2019
- Published by Science Publishing Group in International Journal of Biochemistry, Biophysics & Molecular Biology
- Vol. 4 (2) , 25
Determination of Dynamic Viscosity in Samples of Blood Plasma and Hemoglobin Solution Using Nuclear Magnetic Resonance
The viscosity evaluation in Plasma is extremely useful in the clinical evaluation of different diseases. A procedure is presented, based on Protonic Magnetic Resonance, for the evaluation of the dynamic viscosity in Blood Plasma and in hemoglobin solution from the determination of the transverse relaxation time (T2). To experimentally determine the T2 value, the impulse series Carr-Purcell-Meiboon-Gill was used in a MARAN DRX console (OXFORD INSTRUMENTS) and a homogeneous magnetic system (B0 = 0.095T). Values were obtained for the viscosity of the blood plasma and hemoglobin of 1.68 ± 0.12 mPas and 12.78 ± 3.55 mPas respectively, which agreed with the determined, in the same samples, using an Ostwald viscometer (1, 45 ± 0.06 mPas for the plasma and 12.82 ± 3.35 mPas for the dissolution of hemoglobin). The dynamic viscosity of the blood plasma was determined in 236 patients with Multiple Myeloma (2.19 ± 0.58 mPas), 142 with Drepanocytic Anemia (2.20 ± 0.79 mPas) showing statistically significant increases with respect to the characteristic values of the controls (1.68 ± 0.12mPas). Magnetic Relaxation is an option to evaluate plasma viscosity because it minimizes the volume of sample needed and eliminates the need to wash the viscometer between determinations. Magnetic Relaxation can compensate its relative high cost, compared with other Viscosimetry methods, facilitating other determinations of utility in several diseases.
- 1 January 2019
- Published by Science Publishing Group in International Journal of Biochemistry, Biophysics & Molecular Biology
- Vol. 4 (2) , 25
Open AccessDetermination of Dynamic Viscosity in Samples of Blood Plasma and Hemoglobin Solution Using Nuclear Magnetic Resonance
The viscosity evaluation in Plasma is extremely useful in the clinical evaluation of different diseases. A procedure is presented, based on Protonic Magnetic Resonance, for the evaluation of the dynamic viscosity in Blood Plasma and in hemoglobin solution from the determination of the transverse relaxation time (T2). To experimentally determine the T2 value, the impulse series Carr-Purcell-Meiboon-Gill was used in a MARAN DRX console (OXFORD INSTRUMENTS) and a homogeneous magnetic system (B0 = 0.095T). Values were obtained for the viscosity of the blood plasma and hemoglobin of 1.68 ± 0.12 mPas and 12.78 ± 3.55 mPas respectively, which agreed with the determined, in the same samples, using an Ostwald viscometer (1, 45 ± 0.06 mPas for the plasma and 12.82 ± 3.35 mPas for the dissolution of hemoglobin). The dynamic viscosity of the blood plasma was determined in 236 patients with Multiple Myeloma (2.19 ± 0.58 mPas), 142 with Drepanocytic Anemia (2.20 ± 0.79 mPas) showing statistically significant increases with respect to the characteristic values of the controls (1.68 ± 0.12mPas). Magnetic Relaxation is an option to evaluate plasma viscosity because it minimizes the volume of sample needed and eliminates the need to wash the viscometer between determinations. Magnetic Relaxation can compensate its relative high cost, compared with other Viscosimetry methods, facilitating other determinations of utility in several diseases.
- 5 December 2018
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 50 (4) , 541-551
MR Relaxation Studies of Hemoglobin Aggregation Process in Sickle Cell Disease: Application for Diagnostics and Therapeutics
- 5 December 2018
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 50 (4) , 541-551
MR Relaxation Studies of Hemoglobin Aggregation Process in Sickle Cell Disease: Application for Diagnostics and Therapeutics
- 5 June 2018
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 49 (10) , 1075-1083
Plasma Dynamic Viscosity Determined by NMR
- 5 June 2018
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 49 (10) , 1075-1083
Plasma Dynamic Viscosity Determined by NMR