Jadwiga Fabijańska-Mitek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jadwiga Fabijańska-Mitek has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Anna Stachurska
Department of Cell Biology and Immunology, Centre of Postgraduate Medical Education, Marymoncka 99/103, 01-813 Warsaw, Poland
7 shared publications - Anna Adamowicz-Salach
Department of Pediatrics, Hematology and Oncology, Medical University of Warsaw, Warsaw, Poland
3 shared publications Katarzyna Gmerek
Zakład Immunohematologii, Centrum Medyczne Kształcenia Podyplomowego, Kierownik: dr hab. n. med. Jadwiga Fabijańska-Mitek, Warszawa, Polska
3 shared publications- Adrianna Loniewska-Lwowska
Institute of Biochemistry and Biophysics, Polish Academy of Sciences, Warsaw, 02-106, Poland
2 shared publications B. Żupańska
Department of Serology, Institute of Haematology and Blood Transfusion, Warsaw, Poland
2 shared publications- Ewa Mendek-Czajkowska
Institute of Hematology and Transfusiology, Warsaw, Poland
2 shared publications
Latest Publications
- Open Access
- 28 September 2019
- Published by VM Media Group sp. z o.o in Acta Haematologica Polonica
- Vol. 50 (3) , 147-153
Strategie doboru krwinek czerwonych dla biorców w różnych sytuacjach klinicznych
Przed transfuzją krwinek czerwonych wykonuje się rutynowe testy immunohematologiczne, dzięki którym przetacza się biorcom serologicznie zgodną krew dawców. Wyzwaniem dla serologów jest dobór koncentratu krwinek czerwonych (KKCz), gdy uodpornieni biorcy mają alloprzeciwciała z powodu wcześniejszych transfuzji lub ciąż albo wytworzą autoprzeciwciała w niedokrwistościach autoimmunohemolitycznych (NAIH). Wyzwaniem dla klinicystów jest pilna, ratująca życie transfuzja bez próby zgodności. Są to przetoczenia nagłe (krwawienie) oraz sytuacje, gdy brak jest krwi o wyjątkowych fenotypach. Ważne jest tworzenie narodowych rejestrów rzadkich dawców krwinek czerwonych i uczestnictwo w rejestrze międzynarodowym oraz przekazywanie informacji o skutkach niezgodnego przetoczenia i leczeniu ograniczającym hemolizę. Inne problemy dotyczą szczególnych grup biorców krwi, czyli: płodów, noworodków, niemowląt i pozostałych dzieci. Różnią się one cechami hematologicznymi i immunologicznymi, więc testy zgodności muszą się też różnić. Skomplikowane są transfuzje po transplantacjach komórek krwiotwórczych i narządów, gdy z powodu immunologicznego chimeryzmu dochodzi do hemolizy. Ścisła współpraca między klinicystami i immunohematologami jest konieczna, by zapewnić bezpieczeństwo transfuzji w wymienionych sytuacjach klinicznych opisanych w prezentowanej publikacji.
- 28 September 2019
- Published by VM Media Group sp. z o.o in Acta Haematologica Polonica
- Vol. 50 (3) , 147-153
Open AccessStrategie doboru krwinek czerwonych dla biorców w różnych sytuacjach klinicznych
Przed transfuzją krwinek czerwonych wykonuje się rutynowe testy immunohematologiczne, dzięki którym przetacza się biorcom serologicznie zgodną krew dawców. Wyzwaniem dla serologów jest dobór koncentratu krwinek czerwonych (KKCz), gdy uodpornieni biorcy mają alloprzeciwciała z powodu wcześniejszych transfuzji lub ciąż albo wytworzą autoprzeciwciała w niedokrwistościach autoimmunohemolitycznych (NAIH). Wyzwaniem dla klinicystów jest pilna, ratująca życie transfuzja bez próby zgodności. Są to przetoczenia nagłe (krwawienie) oraz sytuacje, gdy brak jest krwi o wyjątkowych fenotypach. Ważne jest tworzenie narodowych rejestrów rzadkich dawców krwinek czerwonych i uczestnictwo w rejestrze międzynarodowym oraz przekazywanie informacji o skutkach niezgodnego przetoczenia i leczeniu ograniczającym hemolizę. Inne problemy dotyczą szczególnych grup biorców krwi, czyli: płodów, noworodków, niemowląt i pozostałych dzieci. Różnią się one cechami hematologicznymi i immunologicznymi, więc testy zgodności muszą się też różnić. Skomplikowane są transfuzje po transplantacjach komórek krwiotwórczych i narządów, gdy z powodu immunologicznego chimeryzmu dochodzi do hemolizy. Ścisła współpraca między klinicystami i immunohematologami jest konieczna, by zapewnić bezpieczeństwo transfuzji w wymienionych sytuacjach klinicznych opisanych w prezentowanej publikacji.
- 8 July 2019
- Published by Wiley in Vox Sanguinis
- Vol. 114 (6) , 576-587
Selected CD molecules and the phagocytosis of microvesicles released from erythrocytesex vivo
Background and objectives: The accumulation of microvesicles in erythrocyte concentrates during storage or irradiation may be responsible for clinical symptoms such as inflammation, coagulation and immunization. Our aim was to determine whether any of the cluster of differentiation (CD) molecules responsible for important functions are present on microvesicles, and if their expression level is dependent on the storage period of erythrocyte concentrates.Material and methods: Erythrocyte microvesicles were isolated from ‘fresh’ (2ndday) and ‘old’ (42ndday) stored erythrocyte concentrates. Qualitative cytometric analysis of 0·5 µm, erythrocyte‐derived, PS‐exposing vesicles was performed using the annexin V‐FITC, anti‐CD235a‐PE antibody and calibrated beads. The microvesicles were also visualized under a confocal microscope. The expression of the molecules CD235a, CD44, CD47, CD55, CD59 and of phosphatidylserine (PS) was compared using flow cytometry. Measurements of microvesicle phagocytosis by human monocytes were carried out using a flow cytometer and a confocal microscope.Results: The analysis of the microvesicles with calibration beads allowed us to identify these structures with a diameter of about 0·5 µm in the ‘fresh’ and ‘old’ samples. At day 2, the microvesicles had elevated expression levels of CD47, reduced expression levels of PS, CD55 and CD59. The phagocytosis index was higher for the microvesicles isolated from the 42‐day‐old erythrocyte concentrates.Conclusion: This research may bring us closer to understanding the factors responsible for erythrocyte ageing and to evaluate the quality of stored red blood concentrates intended for transfusion.
- 8 July 2019
- Published by Wiley in Vox Sanguinis
- Vol. 114 (6) , 576-587
Selected CD molecules and the phagocytosis of microvesicles released from erythrocytesex vivo
Background and objectives: The accumulation of microvesicles in erythrocyte concentrates during storage or irradiation may be responsible for clinical symptoms such as inflammation, coagulation and immunization. Our aim was to determine whether any of the cluster of differentiation (CD) molecules responsible for important functions are present on microvesicles, and if their expression level is dependent on the storage period of erythrocyte concentrates.Material and methods: Erythrocyte microvesicles were isolated from ‘fresh’ (2ndday) and ‘old’ (42ndday) stored erythrocyte concentrates. Qualitative cytometric analysis of 0·5 µm, erythrocyte‐derived, PS‐exposing vesicles was performed using the annexin V‐FITC, anti‐CD235a‐PE antibody and calibrated beads. The microvesicles were also visualized under a confocal microscope. The expression of the molecules CD235a, CD44, CD47, CD55, CD59 and of phosphatidylserine (PS) was compared using flow cytometry. Measurements of microvesicle phagocytosis by human monocytes were carried out using a flow cytometer and a confocal microscope.Results: The analysis of the microvesicles with calibration beads allowed us to identify these structures with a diameter of about 0·5 µm in the ‘fresh’ and ‘old’ samples. At day 2, the microvesicles had elevated expression levels of CD47, reduced expression levels of PS, CD55 and CD59. The phagocytosis index was higher for the microvesicles isolated from the 42‐day‐old erythrocyte concentrates.Conclusion: This research may bring us closer to understanding the factors responsible for erythrocyte ageing and to evaluate the quality of stored red blood concentrates intended for transfusion.
- 30 September 2017
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 40 (2) , 128-135
Diminished presentation of complement regulatory protein CD55 on red blood cells from patients with hereditary haemolytic anaemias
Introduction: Hereditary haemolytic anaemias (HHA) encompass a heterogeneous group of anaemias characterized by decreased red blood cell survival. The aim of this study was to evaluate the status of red blood cell (RBC) surface molecules known or previously proposed to participate in preventing premature RBC clearance, analysing erythrocytes from patients with two types of HHA: hereditary spherocytosis (HS) and microcytosis.Material/Methods: Relative binding of five monoclonal antibodies (mAbs), anti‐CD55, anti‐CD59, anti‐CD44, anti‐CD47 and anti‐CD58, was evaluated in erythrocytes of patients with HS and hereditary microcytosis, using flow cytometry. The amount of CD55 protein was assessed by semi‐quantitative Western blots densitometry analysis.Results: The majority of both HS and microcytic patients demonstrated significant reduction of anti‐CD55 binding by erythrocytes (average 23% and 19%, respectively, P < .001), with no concomitant anti‐CD59‐binding deficiency. Anti‐CD44, anti‐CD47 and anti‐CD58 binding was within the healthy control range or was slightly decreased.Conclusions: This study provides evidence supporting the presence of erythrocytes deficient in CD55 presentation in HS and hereditary microcytosis. Moreover, deficiency of CD55 antigen presentation on RBC does not correlate with the amount of CD55 in RBC membrane. Further studies using molecular techniques will clarify the exact participation of CD55 deficiency in premature RBC clearance in HHA.
- 30 September 2017
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 40 (2) , 128-135
Diminished presentation of complement regulatory protein CD55 on red blood cells from patients with hereditary haemolytic anaemias
Introduction: Hereditary haemolytic anaemias (HHA) encompass a heterogeneous group of anaemias characterized by decreased red blood cell survival. The aim of this study was to evaluate the status of red blood cell (RBC) surface molecules known or previously proposed to participate in preventing premature RBC clearance, analysing erythrocytes from patients with two types of HHA: hereditary spherocytosis (HS) and microcytosis.Material/Methods: Relative binding of five monoclonal antibodies (mAbs), anti‐CD55, anti‐CD59, anti‐CD44, anti‐CD47 and anti‐CD58, was evaluated in erythrocytes of patients with HS and hereditary microcytosis, using flow cytometry. The amount of CD55 protein was assessed by semi‐quantitative Western blots densitometry analysis.Results: The majority of both HS and microcytic patients demonstrated significant reduction of anti‐CD55 binding by erythrocytes (average 23% and 19%, respectively, P < .001), with no concomitant anti‐CD59‐binding deficiency. Anti‐CD44, anti‐CD47 and anti‐CD58 binding was within the healthy control range or was slightly decreased.Conclusions: This study provides evidence supporting the presence of erythrocytes deficient in CD55 presentation in HS and hereditary microcytosis. Moreover, deficiency of CD55 antigen presentation on RBC does not correlate with the amount of CD55 in RBC membrane. Further studies using molecular techniques will clarify the exact participation of CD55 deficiency in premature RBC clearance in HHA.
- 1 July 2017
- Published by Walter de Gruyter GmbH in Acta Haematologica Polonica
- Vol. 48 (3) , 183-188
Zastosowanie cytometrii przepływowej w badaniach immunohematologicznych krwinek czerwonych
- 1 July 2017
- Published by Walter de Gruyter GmbH in Acta Haematologica Polonica
- Vol. 48 (3) , 183-188
Zastosowanie cytometrii przepływowej w badaniach immunohematologicznych krwinek czerwonych
- 13 September 2016
- Published by Wiley in Cell Biology International
- Vol. 40 (11) , 1195-1203
3D visualization and quantitative analysis of human erythrocyte phagocytosis
Since the erythrophagocytosis of opsonized erythrocytes is investigated mainly by calculating the phagocytic index using subjective light microscopy evaluation, we present methods for the quantitative and qualitative analysis of human cell erythrophagocytosis. Erythrocytes from two storage periods were used. Using Imaris software, we were able to create a three‐dimensional model of erythrophagocytosis. The use of microscopy instead of cytometry revealed a significantly higher number of monocytes and erythrocytes that appeared active in phagocytosis. Spatial reconstruction allowed for detailed analysis of the process by precisely locating erythrocytes in phagocytes. Additionally, a technique of sequential image registration using Nis Elements software allowed for observation of the course of phagocytosis over a range of time intervals. This in vitro research may be helpful for understanding the cellular interactions between monocytes and erythrocytes. The cytometric method—being relatively rapid, sensitive, and specific—can serve as an alternative technique to microscopy in the quantitative analysis of erythrophagocytosis. This allows us to avoid counting the erythrocytes nonspecifically attached to monocytes and gives objective results.
- 13 September 2016
- Published by Wiley in Cell Biology International
- Vol. 40 (11) , 1195-1203
3D visualization and quantitative analysis of human erythrocyte phagocytosis
Since the erythrophagocytosis of opsonized erythrocytes is investigated mainly by calculating the phagocytic index using subjective light microscopy evaluation, we present methods for the quantitative and qualitative analysis of human cell erythrophagocytosis. Erythrocytes from two storage periods were used. Using Imaris software, we were able to create a three‐dimensional model of erythrophagocytosis. The use of microscopy instead of cytometry revealed a significantly higher number of monocytes and erythrocytes that appeared active in phagocytosis. Spatial reconstruction allowed for detailed analysis of the process by precisely locating erythrocytes in phagocytes. Additionally, a technique of sequential image registration using Nis Elements software allowed for observation of the course of phagocytosis over a range of time intervals. This in vitro research may be helpful for understanding the cellular interactions between monocytes and erythrocytes. The cytometric method—being relatively rapid, sensitive, and specific—can serve as an alternative technique to microscopy in the quantitative analysis of erythrophagocytosis. This allows us to avoid counting the erythrocytes nonspecifically attached to monocytes and gives objective results.
- 20 June 2016
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 38 (4) , 419-425
Quantitative fetomaternal hemorrhage assessment with the use of five laboratory tests
Summary: Introduction: In various countries, standard doses of anti‐D IgG used for postpartum immunoprophylaxis of hemolytic disease of fetus and newborn (HDFN) vary from 100 μg to 300 μg. There are also different regulations concerning FMH assessment, and opinions about applicable tests are inconclusive.Methods: Three flow cytometry tests (FCTs) with anti‐D, anti‐HbF, anti‐HbF+CA antibodies, and two modifications of microscopic Kleihauer–Betke test (KBT) were used.Results: In all artificial mixtures with known concentrations, FCTs and KBT with counting 10 000 RBCs had similar satisfying sensitivity and specificity. KBT with counting 2000 RBCs had to be disqualified because of significant discrepancies between expected and measured values of FMH. The test procedure with anti‐D was easier and shorter than the remaining tests, but it can be only used for FMH assessment in RhD‐negative mothers with RhD‐positive newborns. In one clinical sample, it was impossible to distinguish fetal RBCs from maternal F cells in KBT and FC with anti‐HbF but other tests were useful.Conclusion: In the four tests, correlation between expected and obtained results was appropriate (CCC ̴1). Each test had some advantage and limitation in any clinical situation. Therefore, it is best to have opportunity to perform two or three assays in the laboratory.
- 20 June 2016
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 38 (4) , 419-425
Quantitative fetomaternal hemorrhage assessment with the use of five laboratory tests
Summary: Introduction: In various countries, standard doses of anti‐D IgG used for postpartum immunoprophylaxis of hemolytic disease of fetus and newborn (HDFN) vary from 100 μg to 300 μg. There are also different regulations concerning FMH assessment, and opinions about applicable tests are inconclusive.Methods: Three flow cytometry tests (FCTs) with anti‐D, anti‐HbF, anti‐HbF+CA antibodies, and two modifications of microscopic Kleihauer–Betke test (KBT) were used.Results: In all artificial mixtures with known concentrations, FCTs and KBT with counting 10 000 RBCs had similar satisfying sensitivity and specificity. KBT with counting 2000 RBCs had to be disqualified because of significant discrepancies between expected and measured values of FMH. The test procedure with anti‐D was easier and shorter than the remaining tests, but it can be only used for FMH assessment in RhD‐negative mothers with RhD‐positive newborns. In one clinical sample, it was impossible to distinguish fetal RBCs from maternal F cells in KBT and FC with anti‐HbF but other tests were useful.Conclusion: In the four tests, correlation between expected and obtained results was appropriate (CCC ̴1). Each test had some advantage and limitation in any clinical situation. Therefore, it is best to have opportunity to perform two or three assays in the laboratory.
- 1 September 2015
- Published by Walter de Gruyter GmbH in Acta Haematologica Polonica
- Vol. 46, 81-82
Zmiany stanu redox i poziomu obrony antyoksydacyjnej w talasemii i innych mikrocytozach
- 1 September 2015
- Published by Walter de Gruyter GmbH in Acta Haematologica Polonica
- Vol. 46, 81-82
Zmiany stanu redox i poziomu obrony antyoksydacyjnej w talasemii i innych mikrocytozach
- Open Access
- 1 January 2014
- Published by VM Media Group sp. z o.o in Ginekologia Polska
- Vol. 85 (8) , 614-8
Feto-maternal haemorrhage assessment in a woman with a large population of red blood cells containing fetal haemoglobin
FMH quantification is necessary to calculate an individual dose of prophylactic anti-RhD immunoglobulin and to diagnose fetal anaemia causes. We encountered a healthy woman with a numerous RBCs containing fetal haemoglobin (HbF). To investigate the cause of this sign and the correct evaluation of fetal RBCs in maternal circulation. Patients samples and artificial mixtures were tested by microscopic Kleihaur-Betke (KB) and flow cytometric (FC) tests with anti-HbF + anti-CA (carbonic anhydrase), and with anti-D. The patient's blood count with reticulocyte parameters, and concentration of bilirubin, haptoglobin, iron, transferrin, ferritin, hepcidin, sTR, HbF, HbA2 were measured. Genes coding the beta- and gamma-globin were sequenced. It was impossible to distinguish the population of fetal and maternal HbF positive cells using KBT and FC with anti-HbF. Application of anti-CA and anti-D allowed to separate them. Maternal blood haematological and biochemical parameters were normal but HbF was 3.3% of total Hb concentration (normal < 1%). There were no mutations in the beta- and gamma-globin genes, but Xmn I polymorphism at -158 position in gamma-globin gene was detected in the homozygous state. A very large population of HbF positive cells sometimes can be detect in a healthy woman. Implementation of the various procedures for FMH assessment is necessary in the such case, otherwise, the detection of fetal erythrocytes may not be possible or can give false results.
- 1 January 2014
- Published by VM Media Group sp. z o.o in Ginekologia Polska
- Vol. 85 (8) , 614-8
Open AccessFeto-maternal haemorrhage assessment in a woman with a large population of red blood cells containing fetal haemoglobin
FMH quantification is necessary to calculate an individual dose of prophylactic anti-RhD immunoglobulin and to diagnose fetal anaemia causes. We encountered a healthy woman with a numerous RBCs containing fetal haemoglobin (HbF). To investigate the cause of this sign and the correct evaluation of fetal RBCs in maternal circulation. Patients samples and artificial mixtures were tested by microscopic Kleihaur-Betke (KB) and flow cytometric (FC) tests with anti-HbF + anti-CA (carbonic anhydrase), and with anti-D. The patient's blood count with reticulocyte parameters, and concentration of bilirubin, haptoglobin, iron, transferrin, ferritin, hepcidin, sTR, HbF, HbA2 were measured. Genes coding the beta- and gamma-globin were sequenced. It was impossible to distinguish the population of fetal and maternal HbF positive cells using KBT and FC with anti-HbF. Application of anti-CA and anti-D allowed to separate them. Maternal blood haematological and biochemical parameters were normal but HbF was 3.3% of total Hb concentration (normal < 1%). There were no mutations in the beta- and gamma-globin genes, but Xmn I polymorphism at -158 position in gamma-globin gene was detected in the homozygous state. A very large population of HbF positive cells sometimes can be detect in a healthy woman. Implementation of the various procedures for FMH assessment is necessary in the such case, otherwise, the detection of fetal erythrocytes may not be possible or can give false results.
- 30 September 2013
- Published by Walter de Gruyter GmbH in Acta Haematologica Polonica
- Vol. 44 (3) , 265-270
Zastosowanie cytometrii przepływowej oraz analizy proteomicznej w ocenie erytrocytarnych białek błonowych podczas przechowywania koncentratów krwinek czerwonych
For over 100 years the erythrocyte cell membrane attracted interest of transfusiologists mainly due to the antigens localized on their surface and associated risks of patient alloimmunisation and therefore the need of serological selection of donor's and recipient's blood. Presently it is known that RBC antigens and other membrane proteins play important transport and protective functions, and are involved in adhesion, maintenance of cell shape and in the process of aging and phagocytosis. Since the available results of retrospective clinical observations suggest an adverse effect of transfusion on selected groups of patients, it is important to undertake studies on the changes taking place within the cell membrane of erythrocytes stored in blood banks. Flow cytometric analysis of stored leucodepleted or non-leucodepleted erythrocyte concentrates, revealed significant changes in the level of expression of many RBC surface molecules: CD44, CD47, CD55, CD58, CD59, CD235a (GPA). In parallel, a significant development of proteomic analysis of stored RBCs is observed. Stored RBCs offer less variability of biological material, caused by drugs, illnesses, etc. when compared with clinical proteomics studies; however, the complexity of the methodology and the lack of uniform and comparable procedures may cause misinterpretation and even create artifacts. Still, modern research methods offer hope for the elaboration of aging biomarkers of stored RBCs as well as for raising the level of transfusion medicine quality.
- 30 September 2013
- Published by Walter de Gruyter GmbH in Acta Haematologica Polonica
- Vol. 44 (3) , 265-270
Zastosowanie cytometrii przepływowej oraz analizy proteomicznej w ocenie erytrocytarnych białek błonowych podczas przechowywania koncentratów krwinek czerwonych
For over 100 years the erythrocyte cell membrane attracted interest of transfusiologists mainly due to the antigens localized on their surface and associated risks of patient alloimmunisation and therefore the need of serological selection of donor's and recipient's blood. Presently it is known that RBC antigens and other membrane proteins play important transport and protective functions, and are involved in adhesion, maintenance of cell shape and in the process of aging and phagocytosis. Since the available results of retrospective clinical observations suggest an adverse effect of transfusion on selected groups of patients, it is important to undertake studies on the changes taking place within the cell membrane of erythrocytes stored in blood banks. Flow cytometric analysis of stored leucodepleted or non-leucodepleted erythrocyte concentrates, revealed significant changes in the level of expression of many RBC surface molecules: CD44, CD47, CD55, CD58, CD59, CD235a (GPA). In parallel, a significant development of proteomic analysis of stored RBCs is observed. Stored RBCs offer less variability of biological material, caused by drugs, illnesses, etc. when compared with clinical proteomics studies; however, the complexity of the methodology and the lack of uniform and comparable procedures may cause misinterpretation and even create artifacts. Still, modern research methods offer hope for the elaboration of aging biomarkers of stored RBCs as well as for raising the level of transfusion medicine quality.
- Open Access
- 8 July 2013
- Published by Termedia Sp. z.o.o. in Central European Journal of Immunology
- Vol. 38 (2) , 208-213
Experimental immunologyApplication of flow cytometry and microscopy methods in erythrophagocytosis measurement
Background: Phagocytic cells engulf erythrocytes coated with IgG antibodies and/or C3 complement components in specific cellular response. Since interaction of antibody-coated RBCs with phagocytes is evaluated mainly by measurements of the phagocytic index using a subjective microscopy method, we have applied the flow cytometry technique for erythrophagocytosis research. Aim of the study: To evaluate and compare cytometric and microscopic methods in detection and quantification of cells involved in erythrophagocytosis. Material and methods: Monocytes and erythrocytes were isolated from the 52 human blood samples. RhD positive donor’s RBCs were opsonized by specific human IgG anti-D diagnostic serum. Flow cytometry measurements of CD14+ monocytes and CD235+ erythrocytes incubated at 37°C or 4°C were performed using FACSCantoII cytometer and FACSDiva Software. Quantification of the erythrophagocytosis process was performed using cells fixed on a microscopic slide, and dynamics of this process was carried out with the use of Nikon Diaphot 300 optical microscope and Nis Elements Software. Results: Statistical analysis of the results obtained by flow cytometry showed a lower coefficient of variation, and thus a more accurate measurement compared with the microscopic method. The flow cytometry procedure makes it possible to distinguish fully-ingested erythrocytes from these attached to the phagocyte, and hence to obtain more reliable results. Conclusions: Flow cytometry can be an alternative technique in detection and evaluation of red blood cells phagocytosis since it is relatively rapid, more sensitive and objective than microscopy.
- 8 July 2013
- Published by Termedia Sp. z.o.o. in Central European Journal of Immunology
- Vol. 38 (2) , 208-213
Open AccessExperimental immunologyApplication of flow cytometry and microscopy methods in erythrophagocytosis measurement
Background: Phagocytic cells engulf erythrocytes coated with IgG antibodies and/or C3 complement components in specific cellular response. Since interaction of antibody-coated RBCs with phagocytes is evaluated mainly by measurements of the phagocytic index using a subjective microscopy method, we have applied the flow cytometry technique for erythrophagocytosis research. Aim of the study: To evaluate and compare cytometric and microscopic methods in detection and quantification of cells involved in erythrophagocytosis. Material and methods: Monocytes and erythrocytes were isolated from the 52 human blood samples. RhD positive donor’s RBCs were opsonized by specific human IgG anti-D diagnostic serum. Flow cytometry measurements of CD14+ monocytes and CD235+ erythrocytes incubated at 37°C or 4°C were performed using FACSCantoII cytometer and FACSDiva Software. Quantification of the erythrophagocytosis process was performed using cells fixed on a microscopic slide, and dynamics of this process was carried out with the use of Nikon Diaphot 300 optical microscope and Nis Elements Software. Results: Statistical analysis of the results obtained by flow cytometry showed a lower coefficient of variation, and thus a more accurate measurement compared with the microscopic method. The flow cytometry procedure makes it possible to distinguish fully-ingested erythrocytes from these attached to the phagocyte, and hence to obtain more reliable results. Conclusions: Flow cytometry can be an alternative technique in detection and evaluation of red blood cells phagocytosis since it is relatively rapid, more sensitive and objective than microscopy.