Kwan Woo Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kwan Woo Kim has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
Eun Jeong Jang
Department of Surgery, Dong-A University College of Medicine, Dong-A University Medical Center, Busan, Korea
9 shared publications- Eun Jeong Jang
Department of Surgery, Dong-A University College of Medicine, Dong-A University Medical Center, Busan, Korea
8 shared publications - Dong-Sik Kim
Division of HBP Surgery and Liver Transplantation, Department of Surgery, Korea University College of Medicine, Seoul, Republic of Korea
4 shared publications Sung Hwa Kang
Department of Surgery, Dong-A University College of Medicine, Dong-A University Medical Center, Busan, Republic of Korea
4 shared publications- Sung Hwa Kang
Department of Surgery, Dong-A university College of Medicine, Busan, Korea
4 shared publications - Bong-Wan Kim
Department of Liver Transplantation and Hepatobiliary Surgery, Ajou University School of Medicine, Suwon, South Korea
3 shared publications
Latest Publications
- 24 September 2026
- Published by Springer Nature in Surgical Endoscopy
- p. 1-9
Transitioning to the robotic era for perihilar cholangiocarcinoma: initial implementation and outcomes in a single center
Background Robotic surgery for perihilar cholangiocarcinoma (pCCA) remains controversial owing to concerns regarding its technical feasibility and oncological adequacy. This study evaluated the early clinical outcomes of robotic surgery for pCCA during the institutional transition from open to robotic surgery. Methods We retrospectively analyzed 76 patients who underwent curative-intent resection for pCCA between January 2013 and January 2026. Of these patients, 66 underwent open surgery and 10 underwent robotic resection. Robotic surgery was introduced following extensive institutional experience with open and complex robotic hepatobiliary procedures. Perioperative outcomes, oncological parameters, and textbook outcome (TO) achievement were compared between the groups. Results R0 resection was achieved in 90.0% of robotic cases and 78.8% of open cases, and lymph node retrieval did not differ significantly between the groups. A higher proportion of patients in the robotic group attained TO (50.0% vs. 36.3%), although this trend did not reach statistical significance (P = 0.415). Major complications occurred in 30.0% of robotic cases and 25.7% of open cases (P = 0.780), and no 90-day mortality occurred in the robotic group. The length of hospital stay was similar despite the minimally invasive approach. Conclusions Robotic surgery for pCCA is feasible and can be safely implemented following institutional validation in highly selected patients during the early implementation phase. While our early experience demonstrates acceptable perioperative outcomes, additional studies with larger cohorts and long-term follow-up are required to further evaluate the clinical utility and outcomes of robotic surgery and to define its role in pCCA.
- 24 September 2026
- Published by Springer Nature in Surgical Endoscopy
- p. 1-9
Transitioning to the robotic era for perihilar cholangiocarcinoma: initial implementation and outcomes in a single center
Background Robotic surgery for perihilar cholangiocarcinoma (pCCA) remains controversial owing to concerns regarding its technical feasibility and oncological adequacy. This study evaluated the early clinical outcomes of robotic surgery for pCCA during the institutional transition from open to robotic surgery. Methods We retrospectively analyzed 76 patients who underwent curative-intent resection for pCCA between January 2013 and January 2026. Of these patients, 66 underwent open surgery and 10 underwent robotic resection. Robotic surgery was introduced following extensive institutional experience with open and complex robotic hepatobiliary procedures. Perioperative outcomes, oncological parameters, and textbook outcome (TO) achievement were compared between the groups. Results R0 resection was achieved in 90.0% of robotic cases and 78.8% of open cases, and lymph node retrieval did not differ significantly between the groups. A higher proportion of patients in the robotic group attained TO (50.0% vs. 36.3%), although this trend did not reach statistical significance (P = 0.415). Major complications occurred in 30.0% of robotic cases and 25.7% of open cases (P = 0.780), and no 90-day mortality occurred in the robotic group. The length of hospital stay was similar despite the minimally invasive approach. Conclusions Robotic surgery for pCCA is feasible and can be safely implemented following institutional validation in highly selected patients during the early implementation phase. While our early experience demonstrates acceptable perioperative outcomes, additional studies with larger cohorts and long-term follow-up are required to further evaluate the clinical utility and outcomes of robotic surgery and to define its role in pCCA.
- Open Access
- 31 August 2026
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2026 (9) , rjag766
Duplicate gallbladder masquerading as a choledochal cyst: a case of single-port robotic surgery
Gallbladder duplication is a rare congenital anomaly (1 in 4000 births) that can mimic other biliary pathologies, risking iatrogenic injury. A 61-year-old male presented with fever, right upper quadrant pain, and elevated aminotransferases. Contrast-enhanced computed tomography and magnetic resonance imaging initially suggested a 3.6-cm Todani type II choledochal cyst posterior to the gallbladder. Suspecting duplication, surgeons utilized a single-port robotic approach via the da Vinci SP system. Intraoperatively, two distinct gallbladders with independent cystic ducts were identified and successfully resected without complications. The operative time was 65 min, and histopathology confirmed chronic cholecystitis in both specimens. This case highlights the difficulty of differentiating gallbladder duplication from a type II choledochal cyst using cross-sectional imaging. Single-port robotic cholecystectomy offers enhanced visualization and articulating instrumentation, facilitating the safe, precise management of complex biliary anomalies.
- 31 August 2026
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2026 (9) , rjag766
Open AccessDuplicate gallbladder masquerading as a choledochal cyst: a case of single-port robotic surgery
Gallbladder duplication is a rare congenital anomaly (1 in 4000 births) that can mimic other biliary pathologies, risking iatrogenic injury. A 61-year-old male presented with fever, right upper quadrant pain, and elevated aminotransferases. Contrast-enhanced computed tomography and magnetic resonance imaging initially suggested a 3.6-cm Todani type II choledochal cyst posterior to the gallbladder. Suspecting duplication, surgeons utilized a single-port robotic approach via the da Vinci SP system. Intraoperatively, two distinct gallbladders with independent cystic ducts were identified and successfully resected without complications. The operative time was 65 min, and histopathology confirmed chronic cholecystitis in both specimens. This case highlights the difficulty of differentiating gallbladder duplication from a type II choledochal cyst using cross-sectional imaging. Single-port robotic cholecystectomy offers enhanced visualization and articulating instrumentation, facilitating the safe, precise management of complex biliary anomalies.
- Open Access
- 3 March 2026
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 27 (5) , 2366
Three-Dimensional Culture of Primary Hepatocytes in a Single-Cell Layer on Poly(vinyl alcohol) Nanofibrous Membrane
Primary hepatocyte cultures serve as an ex vivo model of liver physiology. This study aims to employ poly(vinyl alcohol) (PVA) nanofiber membranes (NMs) to establish a three-dimensional (3D) culture system that supports the long-term functionality of primary hepatocytes. Primary hepatocytes were monocultured on a PVA NM or indirectly cocultured with NIH3T3 fibroblasts on a distinct polycaprolactone (PCL) NM layer. Monocultured and cocultured hepatocytes maintained prolonged survival without supplemental growth factors. Cocultured hepatocytes formed larger aggregates composed of cell clusters attached to untreated nanofibers than monocultured cells. However, most primary hepatocytes cultured on NaOH-treated PVA NM and Arg–Gly–Asp (RGD) peptide-blended PVA (RGD-PVA) NM, under monoculture and coculture conditions, formed non-aggregated cells in a single-cell layer. In a bioinert assay, unstimulated dendritic cells were activated on untreated but not NaOH-treated PVA NM. CYP3A4 activity was higher in cocultured cells on RGD-PVA NM with fibroblasts than in monocultured cells on PVA and RGD-PVA NM. Functional hepatocyte cultures were successfully maintained in a 3D single-cell layer on RGD-PVA NM, along with fibroblasts in a layer-by-layer coculture, for a prolonged period. The prolonged culture of hepatocytes in a 3D single-cell layer may facilitate further drug discovery, toxicity studies, and translational liver research.
- 3 March 2026
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 27 (5) , 2366
Open AccessThree-Dimensional Culture of Primary Hepatocytes in a Single-Cell Layer on Poly(vinyl alcohol) Nanofibrous Membrane
Primary hepatocyte cultures serve as an ex vivo model of liver physiology. This study aims to employ poly(vinyl alcohol) (PVA) nanofiber membranes (NMs) to establish a three-dimensional (3D) culture system that supports the long-term functionality of primary hepatocytes. Primary hepatocytes were monocultured on a PVA NM or indirectly cocultured with NIH3T3 fibroblasts on a distinct polycaprolactone (PCL) NM layer. Monocultured and cocultured hepatocytes maintained prolonged survival without supplemental growth factors. Cocultured hepatocytes formed larger aggregates composed of cell clusters attached to untreated nanofibers than monocultured cells. However, most primary hepatocytes cultured on NaOH-treated PVA NM and Arg–Gly–Asp (RGD) peptide-blended PVA (RGD-PVA) NM, under monoculture and coculture conditions, formed non-aggregated cells in a single-cell layer. In a bioinert assay, unstimulated dendritic cells were activated on untreated but not NaOH-treated PVA NM. CYP3A4 activity was higher in cocultured cells on RGD-PVA NM with fibroblasts than in monocultured cells on PVA and RGD-PVA NM. Functional hepatocyte cultures were successfully maintained in a 3D single-cell layer on RGD-PVA NM, along with fibroblasts in a layer-by-layer coculture, for a prolonged period. The prolonged culture of hepatocytes in a 3D single-cell layer may facilitate further drug discovery, toxicity studies, and translational liver research.
- 21 January 2026
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 33 (5) , 3945-3946
Robotic Single-Port Right Hepatectomy: Unveiling New Possibilities
Minimally invasive liver resections, particularly right hepatectomy, are technically challenging. Single-port (SP) laparoscopic liver resection has been co
- 21 January 2026
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 33 (5) , 3945-3946
Robotic Single-Port Right Hepatectomy: Unveiling New Possibilities
Minimally invasive liver resections, particularly right hepatectomy, are technically challenging. Single-port (SP) laparoscopic liver resection has been co
- 3 October 2025
- Published by Springer Nature in Surgical Endoscopy
- Vol. 39 (12) , 8480-8487
Novel single-port robotic hepatectomy: initial clinical experience and outcomes
Background The objective of this study was to evaluate the feasibility, safety, and early outcomes of single-port (SP) robotic liver resection, including major and minor hepatectomies, using the da Vinci SP system in a low-to-intermediate-volume hepatobiliary center. Methods Twenty patients underwent robotic SP surgery between April 2024 and May 2025. Among them, 14 underwent liver resections using the SP platform, including five major (right or left hepatectomy) and nine minor (wedge resection, monosegmentectomy, caudate lobectomy, or left lateral sectionectomy) procedures. Perioperative and short-term outcomes were retrospectively analyzed. Surgical techniques, including port placement and inflow control, were standardized. In selected cases, indocyanine green fluorescence imaging was performed for enhanced anatomical precision. No conversion to multiport or open surgery was required. Results The median operative time was 201.1 min; the median hospital stay was 7.2 days. No major postoperative complications or readmissions were observed. One patient required a blood transfusion. All malignant cases achieved R0 resection; lymph node dissection was performed when indicated, and an average of 9.3 nodes was retrieved. Instrument articulation and visualization were optimized using the cobra mode, while floating port strategies were adopted based on the target location. Conclusion SP robotic liver resection is technically feasible and safe for major and minor hepatectomies. The platform overcomes many ergonomic and visualization challenges of SP laparoscopy while maintaining oncological integrity. Despite limitations, including the lack of integrated energy devices and reduced working space, the SP system offers cosmetic, precision, and ergonomic advantages. Our findings support the early adoption of SP robotic liver surgery, even in moderate-volume institutions.
- 3 October 2025
- Published by Springer Nature in Surgical Endoscopy
- Vol. 39 (12) , 8480-8487
Novel single-port robotic hepatectomy: initial clinical experience and outcomes
Background The objective of this study was to evaluate the feasibility, safety, and early outcomes of single-port (SP) robotic liver resection, including major and minor hepatectomies, using the da Vinci SP system in a low-to-intermediate-volume hepatobiliary center. Methods Twenty patients underwent robotic SP surgery between April 2024 and May 2025. Among them, 14 underwent liver resections using the SP platform, including five major (right or left hepatectomy) and nine minor (wedge resection, monosegmentectomy, caudate lobectomy, or left lateral sectionectomy) procedures. Perioperative and short-term outcomes were retrospectively analyzed. Surgical techniques, including port placement and inflow control, were standardized. In selected cases, indocyanine green fluorescence imaging was performed for enhanced anatomical precision. No conversion to multiport or open surgery was required. Results The median operative time was 201.1 min; the median hospital stay was 7.2 days. No major postoperative complications or readmissions were observed. One patient required a blood transfusion. All malignant cases achieved R0 resection; lymph node dissection was performed when indicated, and an average of 9.3 nodes was retrieved. Instrument articulation and visualization were optimized using the cobra mode, while floating port strategies were adopted based on the target location. Conclusion SP robotic liver resection is technically feasible and safe for major and minor hepatectomies. The platform overcomes many ergonomic and visualization challenges of SP laparoscopy while maintaining oncological integrity. Despite limitations, including the lack of integrated energy devices and reduced working space, the SP system offers cosmetic, precision, and ergonomic advantages. Our findings support the early adoption of SP robotic liver surgery, even in moderate-volume institutions.
- Open Access
- 15 June 2025
- Published by The Korean Society of Endo-Laparoscopic & Robotic Surgery in Journal of Minimally Invasive Surgery
- Vol. 28 (2) , 103-107
Approaches in treating infiltrative common bile duct cancer: the potential of robotic hepatopancreatoduodenectomy
Eun Jeong Jang, Kwan Woo Kim. Journal of Minimally Invasive Surgery 2025;28:103-7. https://doi.org/10.7602/jmis.2025.28.2.103
- 15 June 2025
- Published by The Korean Society of Endo-Laparoscopic & Robotic Surgery in Journal of Minimally Invasive Surgery
- Vol. 28 (2) , 103-107
Open AccessApproaches in treating infiltrative common bile duct cancer: the potential of robotic hepatopancreatoduodenectomy
Eun Jeong Jang, Kwan Woo Kim. Journal of Minimally Invasive Surgery 2025;28:103-7. https://doi.org/10.7602/jmis.2025.28.2.103
- Open Access
- 1 January 2025
- Published by The Society of Laparoscopic and Robotic Surgeons in JSLS : Journal of the Society of Laparoscopic & Robotic Surgeons
- Vol. 29 (1)
Robotic Caudate Lobectomy: Feasibility and Techniques with Da Vinci Xi and SP Systems
Minimally invasive hepatectomies, including laparoscopy and robotics, offer potential advantages over traditional open surgery, such as reduced postoperative pain, lower complication rates, and improved oncological outcomes. However, resections ...
- 1 January 2025
- Published by The Society of Laparoscopic and Robotic Surgeons in JSLS : Journal of the Society of Laparoscopic & Robotic Surgeons
- Vol. 29 (1)
Open AccessRobotic Caudate Lobectomy: Feasibility and Techniques with Da Vinci Xi and SP Systems
Minimally invasive hepatectomies, including laparoscopy and robotics, offer potential advantages over traditional open surgery, such as reduced postoperative pain, lower complication rates, and improved oncological outcomes. However, resections ...
- Open Access
- 21 October 2024
- Published by Korean Liver Transplantation Society in Annals of Liver Transplantation
- Vol. 4 (2) , 95-101
Varied strategies for alcohol-related liver transplants in South Korea
Hyun Hwa Choi, Kwang-Woong Lee, Bong-Wan Kim, Dong-Sik Kim, Gyu-Seong Choi, Hae Won Lee, Ho Joong Choi, Jaryung Han, Je Ho Ryu, Kwan Woo Kim, Man Ki Ju, Min-Su Park, Myoung Soo Kim, Seok-Hwan Kim, Seoung Hoon Kim, Shin Hwang, Sung Won Jung, Tae-Seok Kim, Woo Young Shin. Ann Liver Transplant 2024;0:. https://doi.org/10.52604/alt.24.0013
- 21 October 2024
- Published by Korean Liver Transplantation Society in Annals of Liver Transplantation
- Vol. 4 (2) , 95-101
Open AccessVaried strategies for alcohol-related liver transplants in South Korea
Hyun Hwa Choi, Kwang-Woong Lee, Bong-Wan Kim, Dong-Sik Kim, Gyu-Seong Choi, Hae Won Lee, Ho Joong Choi, Jaryung Han, Je Ho Ryu, Kwan Woo Kim, Man Ki Ju, Min-Su Park, Myoung Soo Kim, Seok-Hwan Kim, Seoung Hoon Kim, Shin Hwang, Sung Won Jung, Tae-Seok Kim, Woo Young Shin. Ann Liver Transplant 2024;0:. https://doi.org/10.52604/alt.24.0013
- 17 October 2024
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 32 (1) , 440-442
Exploring the Potential of Robotic Single-Port Surgery for Gallbladder Cancer: Initial Insights and Future Prospects
Robotic surgery has demonstrated outcomes comparable or superior to open and laparoscopic surgeries for extended cholecystectomy.1–8 Despite its adva
- 17 October 2024
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 32 (1) , 440-442
Exploring the Potential of Robotic Single-Port Surgery for Gallbladder Cancer: Initial Insights and Future Prospects
Robotic surgery has demonstrated outcomes comparable or superior to open and laparoscopic surgeries for extended cholecystectomy.1–8 Despite its adva