MBMarion Brickwedde

Marion Brickwedde

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marion Brickwedde has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    OPM-MEG is characterized by increased sensitivity for visual gamma-band oscillations: A parallel EEG/OPM-MEG study

    by Dario Gordillo, Marion Brickwedde, Paul Anders, Peter Krüger, Tilmann Sander, Peter J. Uhlhaas

    Electro- and magnetoencephalography (EEG/MEG) enable non-invasive measurements of gamma-band oscillations, which play a central role in cortical processing. MEG with optically pumped magnetometers (OPM-MEG) is an emerging approach that may provide increased signal-to-noise ratio (SNR) for high-frequency neural oscillations. However, whether this increased SNR extends to measurements of gamma-band oscillations during visual processing has not been established. Here, we performed simultaneous EEG and OPM-MEG recordings in 26 participants during a visual grating task and examined visually-induced power changes in the gamma (30–80 Hz) and alpha/beta (8–30 Hz) frequency ranges. Inter-trial phase coherence (ITPC) was additionally compared across modalities. Effect sizes were quantified using Cohen’s dz. OPM-MEG exhibited significantly higher SNR for visually induced gamma-band responses than EEG (dz = 0.97). This advantage was observed in the majority of participants and was accompanied by higher split-half correlations (EEG: ρ = .88; OPM-MEG: ρ = .94). In contrast, alpha/beta power changes and ITPC did not show consistent modality differences.These findings indicate that OPM-MEG provides enhanced sensitivity for detecting visually induced gamma-band oscillations compared to EEG. Improved non-invasive access to high-frequency neural dynamics may facilitate more precise investigations of cortical circuit function.

  • Open Access

    The Impact of Attention on Speech Entrainment in Clinical High-Risk for Psychosis Individuals

    by Victoria R Poulton, Tineke Grent-'T-Jong, Marion Brickwedde, Joachim Gross, Christoph U. Correll, Peter J. Uhlhaas

    Language comprehension is disrupted in schizophrenia and early-stage psychosis, but the contributions of bottom-up and top-down processing remain unclear. In the current electroencephalography (EEG) study, we investigated speech entrainment in a sample of n=21 individuals at clinical high-risk for psychosis (CHR-P) and n=25 healthy controls (HCs). Continuous speech was presented through an audiobook in three listening conditions: (1) “Active”, in which participants attended to speech; (2) “Passive”, in which participants passively listened to the audiobook while performing a concurrent visual Flanker task; and (3) “Passive-reversed”, in which participants listened to an unintelligible time-reversed and noise-vocoded version of the audiobook while performing the Flanker task. Mutual Information (MI) analyses were used to assess shared information between the speech amplitude envelope and neural oscillations in the delta (0.25-3 Hz), theta (4.5-6.5 Hz), and alpha (7-10 Hz) frequency ranges. Sensor-level and source-level results indicate stronger delta entrainment in the Active vs. Passive conditions across groups. However, compared to controls, CHR-Ps showed reduced theta entrainment in auditory cortices, independent of condition, and decreased alpha entrainment in the Passive vs. Active condition. The findings point to theta entrainment deficits in CHR-Ps during continuous speech processing, indexing a bottom-up impairment. In contrast, delta and alpha entrainment in CHR-Ps were modulated by attention. Together, these findings highlight that both bottom-up and top-down impairments contribute to speech entrainment deficits in CHR-Ps.

  • Open Access

    Cross-modal interaction of human alpha activity does not reflect inhibition of early sensory processing in a frequency-tagging study using EEG and MEG

    by Marion Brickwedde, Rupali Limachya, Roksana Markiewicz, Emma Sutton, Christopher Postzich, Kimron Shapiro, Ole Jensen, Ali Mazaheri

    Selective attention involves prioritising relevant sensory input while suppressing irrelevant stimuli. It has been proposed that oscillatory alpha-band activity (~10 Hz) aids this process by functionally inhibiting early sensory regions. However, recent studies have challenged this notion. Our EEG and MEG studies aimed to investigate whether human alpha oscillations serve as a 'gatekeeper' for downstream signal transmission. We first observed these effects in an EEG study and then replicated them using MEG, which allowed us to localise the sources. We employed a cross-modal paradigm where visual cues indicated whether upcoming targets required visual or auditory discrimination. To assess inhibition, we utilised frequency-tagging, simultaneously flickering the fixation cross at 36 Hz and playing amplitude-modulated white noise at 40 Hz during the cue-to-target interval. Consistent with prior research, we observed an increase in posterior alpha activity following cues signalling auditory targets. However, remarkably, both visual and auditory frequency-tagged responses amplified in anticipation of auditory targets, correlating with alpha activity amplitude. Our findings suggest that when attention shifts to auditory processing, the visual stream remains responsive and is not hindered by occipital alpha activity. This implies that alpha modulation does not solely regulate 'gain control' in early visual areas but rather orchestrates signal transmission to later stages of the processing stream.

  • Open Access

    Characterization of a flexible cap for simultaneous OPM-MEG and EEG measurements

    by Paul Anders, Marion Brickwedde, Tineke Grent-'T-Jong, Peter Krüger, Jens Haueisen, Peter J Uhlhaas, Tilmann H Sander-Thoemmes

    Objective. Combining Magnetoencephalography (MEG) and Electroencephalography (EEG) can lead to more accurate source reconstruction results. Previous efforts of simultaneous EEG and MEG using optically pumped magnetometers (OPM-MEG) used a two-layer setup, where a helmet or cap with mounted OPMs was worn on top of an EEG cap, resulting in decreased OPM signal amplitudes. This is inevitable for rigid OPM-MEG helmets used by most research groups, which are often heavy and need fixation, require time-consuming customization or do not adapt to different head shapes, diminishing the advantages of OPM-MEG. In this study, we therefore aimed to create a flexible cap that enables fully integrated simultaneous OPM-MEG and EEG measurements, which are suitable for source reconstruction and yield the same signal quality as each individual modality. Approach. We integrated OPM mounts into a commercial EEG cap and implemented a sensor localization pipeline based on co-registering the known OPM mount geometry to 3D scans of participants wearing the cap. In a multi-paradigm experiment with five volunteers, we investigated how much OPMs shift during an experiment due to head movements of the participant. We also compared signal-to-noise ratios and artifact strengths between single-modality and multimodal measurements. Main results. The distribution of changes in OPM positions and orientations are within acceptable limits for source reconstruction as published in a simulation study. Occipital OPMs experienced larger shifts. No systematic difference in signal-to-noise ratios or artifact strengths between single-modality and multimodal acquisition could be observed, indicating no signal degradation due to the presence of the other modality. Significance. Measuring simultaneous OPM-MEG and EEG using a flexible cap could improve source reconstruction results and help to bring OPM-MEG to clinical settings due to easier comparison and verification with the established EEG, which is relevant for presurgical epilepsy evaluation.


  • Open Access

    Optically pumped magnetometers enhance neuroimaging performance—An EEG, OPM, and SQUID-MEG study

    by Marion Brickwedde, Paul Anders, Peter Krüger, Tilmann Sander, Peter J. Uhlhaas


  • Open Access

    Cross-modal interaction of Alpha Activity does not reflect inhibition of early sensory processing: A frequency tagging study using EEG and MEG

    by Marion Brickwedde, Rupali Limachya, Roksana Markiewicz, Emma Sutton, Christopher Postzich, Kimron Shapiro, Ole Jensen, Ali Mazaheri

    Selective attention involves prioritizing relevant sensory input while suppressing irrelevant stimuli. It has been proposed that oscillatory alpha-band activity (∼10 Hz) aids this process by functionally inhibiting early sensory regions. However, recent studies have challenged this notion. Our EEG and MEG studies aimed to investigate whether alpha oscillations serve as a ‘gatekeeper’ for downstream signal transmission. We first observed these effects in an EEG study and then replicated them using MEG, which allowed us to localize the sources. We employed a cross-modal paradigm where visual cues indicated whether upcoming targets required visual or auditory discrimination. To assess inhibition, we utilized frequency-tagging, simultaneously flickering the fixation cross at 36 Hz and playing amplitude-modulated white noise at 40 Hz during the cue-to-target interval. Consistent with prior research, we observed an increase in posterior alpha activity following cues signalling auditory targets. However, remarkably, both visual and auditory frequency tagged responses amplified in anticipation of auditory targets, correlating with alpha activity amplitude. Our findings suggest that when attention shifts to auditory processing, the visual stream remains responsive and is not hindered by occipital alpha activity. This implies that alpha modulation does not solely regulate ‘gain control’ in early visual areas but rather orchestrates signal transmission to later stages of the processing stream.


  • Open Access

    OPM quantum sensors enhance non-invasive neuroimaging performance

    by M. Brickwedde, P. Anders, P. Krüger, T. Sander, P. J. Uhlhaas

    Much of our understanding of how neural circuit activity relates to human behaviour as well as mental health stems from non-invasive assessments of the central nervous system. Further progress in key questions, however, requires a higher differentiation of circuit-level activity, which remains constrained by the sensitivity and resolution of existing instruments. Here we show that neural quantum sensing with optically pumped magnetometers (OPMs) addresses this issue by significantly outperforming EEG and conventional MEG in both signal-to-noise ratio (SNR) and signal coherence across trials. SNR for OPMs was increased by up to 205% compared to EEG and by up to 40% compared to conventional MEG. Likewise, the signal coherence across trials of OPMs was increased by up to 61% compared to EEG and by up to 23% compared to conventional MEG. Our data emphasize the important role of OPMs for non-invasive neuroimaging, paving the way for significant advances in basic research as well as translational applications.

  • Open Access

    Magnetically shielded high-resolution visual stimulation for OPM-MEG applications

    by P Anders, M Brickwedde, J Voigt, T Grent-‘t-Jong, P Krüger, J Haueisen, P J Uhlhaas, T Sander

    Many magnetoencephalography (MEG) experiments require visual stimulation (VS) inside a magnetically shielded room (MSR). For conventional MEG utilizing superconducting quantum interference devices (SQUIDs), the participant’s head must stay within the semi-spherical surface of a cryogenic storage Dewar. This design allows to have many SQUID sensors as close as possible to the head in order to achieve good signal quality. Because Dewars have very restricted mobility, VS is usually realized using a projector outside of the MSR, some optical elements and a back-projection screen in the line of sight of the participant. Recently, the feasibility of MEG using optically pumped magnetometers (OPMs) was demonstrated. These sensors can be attached directly to the head because they operate near room temperature. OPM-MEG therefore offers more experimental freedom including different postures, movements or hyperscanning, creating the need for a more flexible kind of VS setup. In this paper, we present a compact, high-resolution VS setup which is enclosed by a portable magnetic shield with an opening for the projection. The VS setup is based on a single-board computer which acts as experiment control device to create visual stimuli, process inputs, log participant activity and set off trigger signals. This setup supports the new possibilities of OPM-MEG and can be easily installed into any MSR. We investigate if the shielded VS inside the MSR generates distortion signals above the noise floor of the OPMs. We also show that visual cortex activity can be evoked with our setup and recorded with a custom-made OPM-MEG cap. By applying two well-established visual stimulation paradigms, we demonstrate the ability of our setup to elicit brain activity in different frequency ranges.


  • Open Access

    Applications of OPM-MEG for translational neuroscience: a perspective

    by Marion Brickwedde, Paul Anders, Andrea A. Kühn, Roxanne Lofredi, Martin Holtkamp, Angela M. Kaindl, Tineke Grent-‘t-Jong, Peter Krüger, Tilmann Sander, Peter J. Uhlhaas

    Magnetoencephalography (MEG) allows the non-invasive measurement of brain activity at millisecond precision combined with localization of the underlying generators. So far, MEG-systems consisted of superconducting quantum interference devices (SQUIDS), which suffer from several limitations. Recent technological advances, however, have enabled the development of novel MEG-systems based on optically pumped magnetometers (OPMs), offering several advantages over conventional SQUID-MEG systems. Considering potential improvements in the measurement of neuronal signals as well as reduced operating costs, the application of OPM-MEG systems for clinical neuroscience and diagnostic settings is highly promising. Here we provide an overview of the current state-of-the art of OPM-MEG and its unique potential for translational neuroscience. First, we discuss the technological features of OPMs and benchmark OPM-MEG against SQUID-MEG and electroencephalography (EEG), followed by a summary of pioneering studies of OPMs in healthy populations. Key applications of OPM-MEG for the investigation of psychiatric and neurological conditions are then reviewed. Specifically, we suggest novel applications of OPM-MEG for the identification of biomarkers and circuit deficits in schizophrenia, dementias, movement disorders, epilepsy, and neurodevelopmental syndromes (autism spectrum disorder and attention deficit hyperactivity disorder). Finally, we give an outlook of OPM-MEG for translational neuroscience with a focus on remaining methodological and technical challenges.


  • Open Access

    Application of rapid invisible frequency tagging for brain computer interfaces

    by Marion Brickwedde, Yulia Bezsudnova, Anna Kowalczyk, Ole Jensen, Alexander Zhigalov