Parthasarathi Bera
Research Subjects
Research Interests
Parthasarathi Bera has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Bikash Patel
Electrical Engineering Department, Kalyani Government Engineering College, Kalyani, West Bengal, India
3 shared publications - Jyotirmoy Biswas
Kalyani Government Engineering College
2 shared publications - Arindam Karmakar1 shared publication
- Arnab Kumar Mondal
Kalyani Government Engineering College
1 shared publication - Deb Mandal1 shared publication
- Koushik Nath1 shared publication
Latest Publications
- 8 October 2025
- Published by Institute of Science, Education and Culture, Kolkata in Indian Science Cruiser
- p. 31-40
AOA based scheduling of EV in Smart Distribution System
In this work, a multi objective scheduling approach is proposed for large-scale application and adoption of Electric Vehicle (EV) in the distribution system. The amount of main grid electricity price production and CO2 emissions are minimized using Arithmetic Optimization Algorithm (AOA) for IEEE-33 bus distribution system incorporated with EV. It is also found that AOA is performed very well to identify the peak hours of the day by analysing different loads curve as well as the load forecasting reports. Keywords: Arithmetic Optimization based Algorithm, AOA, Vehicle to grid, V2G, scheduling, Electric Vehicle, EV, Distribution System Operator, DSO, Electric Vehicle Management System, EVMS.
- 8 October 2025
- Published by Institute of Science, Education and Culture, Kolkata in Indian Science Cruiser
- p. 31-40
AOA based scheduling of EV in Smart Distribution System
In this work, a multi objective scheduling approach is proposed for large-scale application and adoption of Electric Vehicle (EV) in the distribution system. The amount of main grid electricity price production and CO2 emissions are minimized using Arithmetic Optimization Algorithm (AOA) for IEEE-33 bus distribution system incorporated with EV. It is also found that AOA is performed very well to identify the peak hours of the day by analysing different loads curve as well as the load forecasting reports. Keywords: Arithmetic Optimization based Algorithm, AOA, Vehicle to grid, V2G, scheduling, Electric Vehicle, EV, Distribution System Operator, DSO, Electric Vehicle Management System, EVMS.
- 4 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
A New Transmission Line Parameter Estimation Technique and Its Impact on Fault Localization
Parameters of an underground cable (UGC) line are highly prone to change with aging and atmospheric conditions, which severely hamper the performances of some protection algorithms like fault localization methods. Online parameter estimation is the key to solve this problem. Here, a new non-iterative transmission line parameter estimation (TLPE) technique is proposed by deriving the expressions of line resistance, inductance and capacitance mathematically in terms of time-domain voltages and currents. From these derivations, line parameters are directly obtained using only one cycle pre-fault signals. To verify its utility, this TLPE technique is applied for locating faults on a UGC line by lowest potential point search method which becomes very simple with the help of estimated parameters as it need not solve any complex constraints based optimization problem. Extensive simulations are carried out to verify the proposed method and estimated parameters are found accurate for various loading conditions, noises, synchronization errors, data acquisition errors and line types. Moreover, comparison with existing TLPE methods and verification with field-data justify its utility. Appreciable accuracy is also achieved in fault localization, which doesn’t depreciate with cable aging because of usage of line parameters estimated from pre-fault values of the signals utilized for locating faults.
- 4 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
A New Transmission Line Parameter Estimation Technique and Its Impact on Fault Localization
Parameters of an underground cable (UGC) line are highly prone to change with aging and atmospheric conditions, which severely hamper the performances of some protection algorithms like fault localization methods. Online parameter estimation is the key to solve this problem. Here, a new non-iterative transmission line parameter estimation (TLPE) technique is proposed by deriving the expressions of line resistance, inductance and capacitance mathematically in terms of time-domain voltages and currents. From these derivations, line parameters are directly obtained using only one cycle pre-fault signals. To verify its utility, this TLPE technique is applied for locating faults on a UGC line by lowest potential point search method which becomes very simple with the help of estimated parameters as it need not solve any complex constraints based optimization problem. Extensive simulations are carried out to verify the proposed method and estimated parameters are found accurate for various loading conditions, noises, synchronization errors, data acquisition errors and line types. Moreover, comparison with existing TLPE methods and verification with field-data justify its utility. Appreciable accuracy is also achieved in fault localization, which doesn’t depreciate with cable aging because of usage of line parameters estimated from pre-fault values of the signals utilized for locating faults.
- 20 April 2023
- Published by Elsevier in Electric Power Systems Research
- Vol. 221
Determination of control area and design of fuzzy rule-tuned PID controller for LFC of multimachine power system
- 20 April 2023
- Published by Elsevier in Electric Power Systems Research
- Vol. 221
Determination of control area and design of fuzzy rule-tuned PID controller for LFC of multimachine power system
- 20 July 2021
- Published by Institute of Science, Education and Culture, Kolkata in Indian Science Cruiser
- Vol. 35 (3) , 31
AloA Optimized RLNN Controller for LFC of Deregulated Two-Area Power System
- 20 July 2021
- Published by Institute of Science, Education and Culture, Kolkata in Indian Science Cruiser
- Vol. 35 (3) , 31
AloA Optimized RLNN Controller for LFC of Deregulated Two-Area Power System
- 9 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (5) , 2595-2605
A Novel Method to Distinguish Internal and External Faults During Power Swing
The immunity to external faults is very important for any power swing unblocking scheme to improve its reliability. However, most of the available schemes to differentiate faults from power swing have poor reliability as they are not immune to external faults and switching. Phase comparison and current differential protection schemes can be suitable for this purpose, although their accuracy depend on the removal of sub-synchronous frequency and decaying dc component which is very prominent in current signals especially after close-in faults. In this context, the present article proposes a new method to distinguish internal and external faults during power swing on the transmission line by determining the orientation of Lissajous figure of two terminal current signals with the objective to improve the reliability without removing decaying dc component. An index is developed mathematically based on the change of orientation of Lissajous figure due to a fault to distinguish internal and external faults at swing condition and to detect the faulty phase accurately at various conditions. Performance of the method is also evaluated for close-in internal and external faults, switching events, noisy conditions and in presence of decaying dc component and is compared to the available methods to prove its merit.
- 9 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (5) , 2595-2605
A Novel Method to Distinguish Internal and External Faults During Power Swing
The immunity to external faults is very important for any power swing unblocking scheme to improve its reliability. However, most of the available schemes to differentiate faults from power swing have poor reliability as they are not immune to external faults and switching. Phase comparison and current differential protection schemes can be suitable for this purpose, although their accuracy depend on the removal of sub-synchronous frequency and decaying dc component which is very prominent in current signals especially after close-in faults. In this context, the present article proposes a new method to distinguish internal and external faults during power swing on the transmission line by determining the orientation of Lissajous figure of two terminal current signals with the objective to improve the reliability without removing decaying dc component. An index is developed mathematically based on the change of orientation of Lissajous figure due to a fault to distinguish internal and external faults at swing condition and to detect the faulty phase accurately at various conditions. Performance of the method is also evaluated for close-in internal and external faults, switching events, noisy conditions and in presence of decaying dc component and is compared to the available methods to prove its merit.
- 22 September 2018
- Published by Springer Nature
- p. 109-122
Design of Fuzzy-PI Controller for Hybrid Distributed Generation System Using Grey Wolf Optimization Algorithm
- 22 September 2018
- Published by Springer Nature
- p. 109-122
Design of Fuzzy-PI Controller for Hybrid Distributed Generation System Using Grey Wolf Optimization Algorithm
- 27 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 3019-3027
Detection of Power Swing and Fault During Power Swing Using Lissajous Figure
The paper demonstrates a power swing blocking and unblocking technique for distance relay in a hybrid transmission line consisting of an overhead line and an underground cable using Lissajous figure of voltage and current signals. The tangents perpendicular to the axis of current signal (denoted as TPI) on the Lissajous figure are found at exactly half cycle spacing during normal condition, while their spacings deviate from half cycle and are unequal during power swing and large number of TPIs are found within a small duration after fault initiation. This feature of Lissajous figure is utilized to detect the power swing and the fault during power swing. The proposed method is tested on a 5-machine 14-bus power system, simulated in electromagnetic transient program (EMTP) for symmetrical, asymmetrical and non-ideal faults and found accurate. The faults during power swing are detected within few milliseconds after fault initiation for different fault locations, fault resistances, load angles, fault inception times and swing frequencies. The comparative analysis with two conventional and two novel methods shows the potential of the proposed method.
- 27 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 3019-3027
Detection of Power Swing and Fault During Power Swing Using Lissajous Figure
The paper demonstrates a power swing blocking and unblocking technique for distance relay in a hybrid transmission line consisting of an overhead line and an underground cable using Lissajous figure of voltage and current signals. The tangents perpendicular to the axis of current signal (denoted as TPI) on the Lissajous figure are found at exactly half cycle spacing during normal condition, while their spacings deviate from half cycle and are unequal during power swing and large number of TPIs are found within a small duration after fault initiation. This feature of Lissajous figure is utilized to detect the power swing and the fault during power swing. The proposed method is tested on a 5-machine 14-bus power system, simulated in electromagnetic transient program (EMTP) for symmetrical, asymmetrical and non-ideal faults and found accurate. The faults during power swing are detected within few milliseconds after fault initiation for different fault locations, fault resistances, load angles, fault inception times and swing frequencies. The comparative analysis with two conventional and two novel methods shows the potential of the proposed method.
- 24 May 2018
- Published by Springer Nature
- p. 755-766
Design of P-I Controller of Wind Turbine with Doubly Fed Induction Generator Using Flower Pollination Algorithm
- 24 May 2018
- Published by Springer Nature
- p. 755-766
Design of P-I Controller of Wind Turbine with Doubly Fed Induction Generator Using Flower Pollination Algorithm
- 21 July 2017
- Published by Springer Nature
- p. 47-57
Design of Rule-Based Load Frequency Controller for Multi-machine System
- 21 July 2017
- Published by Springer Nature
- p. 47-57
Design of Rule-Based Load Frequency Controller for Multi-machine System
- 1 July 2012
- Published by Kalyani Government Engineering College in Reason-A Technical Journal
- Vol. 11, 47-49-47
Design of CPSS for Multimachine Power System Using Simulated Annealing Algorithm considering G-T Dynamics
Design of CPSS for Multimachine Power System Using Simulated Annealing Algorithm considering G-T Dynamics
- 1 July 2012
- Published by Kalyani Government Engineering College in Reason-A Technical Journal
- Vol. 11, 47-49-47
Design of CPSS for Multimachine Power System Using Simulated Annealing Algorithm considering G-T Dynamics
Design of CPSS for Multimachine Power System Using Simulated Annealing Algorithm considering G-T Dynamics