PZPeng Zhang

Peng Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Peng Zhang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High-Stability Polarization-Based Interrogation Method With Cross-Correlation for Optical Fiber Interferometric Acoustic Sensors

    by Haokun Yang, Shuang Wang, Kun Liu, Junfeng Jiang, Zhiyuan Li, Xiaoshuang Dai, Xueping Li, Peng Zhang, Tiegen Liu

    In this work, we propose and demonstrate a high-stability polarization-based interrogation method using cross-correlation for optical fiber interferometric acoustic sensing. Specifically, an extrinsic Fabry-Perot interferometric (EFPI) sensor based on polyphenylene sulfide (PPS) diaphragm is firstly used for signal detection, and then a cross-correlation interrogation system is formed with a birefringent crystal based on polarization low-coherence interference technology. Finally, the direct current (DC) component of the interference signal can be acquired in real-time with the help of the birefringent crystals block of known length. The system does not require an orthogonal relationship between the interference signals. Moreover, it can still work when the initial cavity length of the sensor drifts due to the influence of the environment. Theoretical simulations and a series of experiments have been carried out to verify the feasibility of the proposed scheme. And experimental results show that the sensor's initial cavity length shifts from 90.082 μm to 88.451μm or 91.692 μm under 1kHz acoustic signal, the maximum relative demodulation error is 0.4539 nm, and the signal-to-noise ratio(SNR)can reach 80 dB. Compared with the reported schemes, the proposed interrogation scheme simplifies the system configuration, and has properties of low cost, strong robustness, and high-frequency, so it has great potential in practical engineering applications.


  • Intensity self-compensation method against multi-factors for polarization-based Fabry–Perot interrogation system

    by Zhiyuan Li, Shuang Wang, Junfeng Jiang, Haokun Yang, Peng Zhang, Xiaoshuang Dai, Xueping Li, Tiegen Liu

    Phase interrogation methods for fiber-optic Fabry–Perot (F-P) sensors may inevitably fail in the field due to the influences of irrelevant factors on signal intensity. To address this severe problem, this Letter proposes an intensity self-compensation method (ISCM) to eliminate the consecutive signal fluctuations of a polarization-based F-P interrogation system caused by multiple factors. By providing only the initial intensities of the reference signals, this attempt realizes the real-time intensity compensation of the output signals without affecting their quadrature relationship. Consecutive intensity fluctuations caused by variation of light source power, fiber loss, and polarization state are reduced to 2%–3% by the ISCM. Furthermore, the method performs ideally under dynamic modulation of the sensor. In addition, it can be applied against the inconsistent fluctuations between signals and is suitable for F-P sensors with single or multiple cavities. Owing to the high efficiency, real-time ability, and no moving parts advantage, the proposed method provides an excellent candidate for improving the accuracy and stability of F-P interrogation systems.


  • A Fiber-Optic Extrinsic Fabry–Perot Hydrophone Based on Archimedes Spiral-Type Sensitive Diaphragm

    by Peng Zhang, Shuang Wang, Junfeng Jiang, Zhiyuan Li, Haokun Yang, Xiaoshuang Dai, Tiegen Liu

    A fiber-optic hydrophone based on extrinsic Fabry-Perot (F-P) interferometer is proposed. The sensitive element of the hydrophone is an Archimedes spiral metal diaphragm, and the inner surface of the diaphragm and the end face of the optical fiber form the F-P cavity. Due to the grooved surface of the sensitive diaphragm, the hydrophone is minimally affected by hydrostatic pressure. The geometry structure of sensor and finite element method (FEM) modeling are presented. Experiments of underwater acoustic response and sensitivity calibration of the hydrophone are carried out and the experimental phase results are demodulated by the orthogonal phase demodulation method based on birefringent crystals and polarization technology. The experiment results show that the hydrophone has a relatively flat signal-to-noise ratio and sensitivity within 1 kHz-20 kHz, and the average sensitivity is -172.52 dB (re. 1 rad/μPa) @ 1-20 kHz. We believe that this type of hydrophone has the potential to be applied in the field of underwater acoustic communication.


  • Open Access

    A Fiber-Optic Accelerometer Based on Extrinsic Fabry-Perot Interference for Low Frequency Micro-Vibration Measurement

    by Peng Zhang, Shuang Wang, Junfeng Jiang, Zhiyuan Li, Haokun Yang, Tiegen Liu

    A fiber-optic accelerometer based on extrinsic Fabry-Perot interferometer (EFPI) is reported. The sensor adopts flywheel diaphragm structure as a sensitive element, where the mass block is bonded in the center, while the beam of the flywheel acts as a spring. The sensitive element forms single degree of freedom spring-mass-damper system. The parameters of the accelerometer are designed based on finite element simulation (FEM), and the transfer function of the sensor is established by numerical simulation. The experiments indicate that the sensor has a wide detection frequency band with the detectable ability for micro-vibration low as 0.01 Hz, and the sensitivity is 7.02 rad/g @20 Hz, and reach an average sensitivity of 6.39 rad/g in 5–20 Hz. The research shows that the accelerometer has a good development prospect in the field of low frequency micro-vibration detection.


  • Real-Time Self-Calibrating Phase-Shifted Demodulation Method Based on Polarized Low-Coherence Interference for Optical Fiber Acoustic Sensor

    by Haokun Yang, Shuang Wang, Kun Liu, Junfeng Jiang, Yuqing Li, Zhiyuan Li, Peng Zhang, Xiaoshuang Dai, Tiegen Liu

    A real-time self-calibrating quadrature phase-shift demodulation method for external Fabry–Perot interferometric (EFPI) sensors is proposed and demonstrated. Two birefringent crystal blocks with matching lengths are used to generate two orthogonal interference signals, and the third rotating birefringent crystal block is used as a compensation path for real-time normalization of two orthogonal interference signals. The signals are finally processed by the differential cross multiplication (DCM) algorithm demodulation. Experimental results show that the demodulation scheme can not only correctly demodulate low-frequency dynamic signals but also demodulate ultrasonic signals with high stability and high speed, and has a signal-to-noise ratio (SNR) of up to 90 dB. When the sensor cavity length drifts between $- 4.94\,\,\mu \text{m}$ and $4.584 ~\mu \text{m}$ , it still has stable demodulation performance and is suitable for EFPI sensors with different diaphragms. The demodulation scheme provides a simple, effective, high-speed, and robust solution for dynamic signal measurement in complex environments based on real-time self-calibrating, which demonstrates great potential in practical engineering applications.


  • Open Access

    Environment-Robust Polarization-Based Phase-Shift Dynamic Demodulation Method for Optical Fiber Acoustic Sensor

    by Shuang Wang, Wenyan Liu, Junfeng Jiang, Zhiyuan Li, Peng Zhang, Tiegen Liu

    In this paper, an environment-robust polarization-based phase-shift dynamic demodulation method for optical fiber acoustic sensor is proposed. Through optical lever effect of polarization low-coherence interference and amplitude scaling differential cross multiplication (AS-DCM) algorithm, acoustic-source induced interference phase of the acoustic sensor can be demodulated in real-time with high precision. The maximum relative phase demodulation error was only 0.694% when the cavity length had an offset ∼4 μm. The maximum cavity length demodulation error was keeping less than 3.988 nm under the optical power reduced ten times, which demonstrated an ultra-stable demodulation for the largest permitted optical power attenuation range, to our best knowledge. The proposed method has a capability of tolerating large optical power attenuation and large cavity length random offset, providing an environment-robust way for optical fiber acoustic sensor working in extreme environments.


  • Real-Time Pressure Measurement Method Based on Rapid Phase Demodulation of Multi-Cavities F-P Sensor

    by Zhiyuan Li, Shuang Wang, Junfeng Jiang, Mei Sang, Yin Yu, Wenyan Liu, Peng Zhang, Tiegen Liu

    In this paper, a novel method for real-time pressure measurement based on rapid phase demodulation of multi-cavities Fabry-Perot (F-P) sensor is proposed. In the demodulation system, according to the principle of low-coherence interference, birefringent crystals, polarizers and analyzers are used to obtain orthogonal signals, which can significantly reduce the influence of irrelevant F-P cavities on the demodulation result, indicating that the method is suitable for rapid demodulation of F-P sensors containing multiple cavities. Experimental results also confirm that the method is able to demodulate the signal of F-P MEMS sensor in real-time. By using the four-quadrant inverse tangent operation instead of differential cross multiplier algorithm to calculate the phase of the F-P sensor, pressure in the range of 110 kPa -200 kPa is measured in real-time, with the demodulation rate of 5 kHz. The measurement errors are less than 0.41 kPa, and the standard deviations are less than 0.25 kPa. The proposed method provides a new idea for the rapid demodulation of F-P sensors containing multiple cavities, and has great potential in promotion and applications of real-time pressure measurement, such as dynamic pressure of aero-engines, shock waves and so on.


  • Hybrid Sapphire Dual-Fabry—Perot-Cavities Sensor for High Temperature and Refractive Index Measurement

    by Xun Yu, Shuang Wang, Junfeng Jiang, Kun Liu, Jie Dong, Peng Zhang, Wen Wu, Tiegen Liu

    We presented a hybrid sapphire dual-Fabry-Perot-cavities sensor for high temperature and refractive index measurement. A double-sided polished sapphire solid wafer is connected in series with a double-sided parallel sapphire C-ring and a single-sided polished sapphire mirror to form the hybrid Fabry-Perot interferometer. The double-sided polished sapphire solid wafer acts as the first Fabry-Perot cavity for temperature sensing, and the sapphire hollow C-ring cavity constitutes the second Fabry-Perot cavity for measuring the refractive index of external environment medium. The single-sided polished sapphire mirror serves as the most distal reflector. Heterogeneous fiber splicing between sapphire fiber and multimode silica fiber is realized to achieve long-distance transmission of interference signals. A series of high temperature measurement experiments range of room temperature to 1080°C in an air environment and refractive index measurement experiments in a liquid environment were carried out. The refractive index and temperature sensitivities were ${2.0659 \times 10^{5}}$ nm/RIU in the RI range of 1.3330~1.3741 and 7.837nm/°C at 1080°C.