Xiaochen Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xiaochen Xu has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Aatish Chandak
Texas Instruments, Bangalore, India
1 shared publication- Abhishek Vishwa
Texas Instruments, Bangalore, India
1 shared publication - Dijeesh K
Texas Instruments, Bangalore, India
1 shared publication Elisa Granata
Texas Instruments, Milan, Italy
1 shared publication- Ge Wang
Rensselaer Polytechnic Institute
1 shared publication - Haiou Shen
Information and Navigation College, Air Force Engineering University, Xi’an, China
1 shared publication
Latest Publications
- Open Access
- 1 June 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1948 (1) , 012219
A density functional theory study on thermal properties of perfect and defective graphene
In present work, the graphene with various defects have been investigated by First-principles based on DFT, and the properties are compared to perfect graphene. The calculated results show that the topological structure exhibits the minimum defect formation energy, which will be the easiest defective structure to form. The Perfect graphene, Single-vacancy graphene and Double-vacancy graphene exhibit metallicity, but the electrical conductivity of Perfect graphene is not as good as vacancy defective graphene. The Topology graphene is semiconductor. Single-vacancy defect emerging in graphene will pin the C atoms along with the vacancy. The C atoms closest to vacancy is easy to loosen in Double-vacancy graphene. The Topology graphene is comparatively stable in defective graphene.
- 1 June 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1948 (1) , 012219
Open AccessA density functional theory study on thermal properties of perfect and defective graphene
In present work, the graphene with various defects have been investigated by First-principles based on DFT, and the properties are compared to perfect graphene. The calculated results show that the topological structure exhibits the minimum defect formation energy, which will be the easiest defective structure to form. The Perfect graphene, Single-vacancy graphene and Double-vacancy graphene exhibit metallicity, but the electrical conductivity of Perfect graphene is not as good as vacancy defective graphene. The Topology graphene is semiconductor. Single-vacancy defect emerging in graphene will pin the C atoms along with the vacancy. The C atoms closest to vacancy is easy to loosen in Double-vacancy graphene. The Topology graphene is comparatively stable in defective graphene.
- 4 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (4) , 1296-1304
A Programmable Platform for Accelerating the Development of Smart Ultrasound Transducer Probe
During the COVID-19 pandemic, an ultra-portable ultrasound smart probe has proven to be one of the few practical diagnostic and monitoring tools for doctors who are fully covered with personal protective equipment. The real-time, safety, ease of sanitization and ultra-portability features of an ultrasound smart probe make it extreme suitable for diagnosing COVID-19. In this paper, we discuss the implementation of a smart probe designed according to the classic architecture of ultrasound scanners. The design balanced both performance and power consumption. This programmable platform for an ultrasound smart probe supports a 64-channel full digital beamformer. The platform’s size is smaller than 10 cm by 5 cm. It achieves a 60-dBFS signal-to-noise ratio (SNR) and an average power consumption of ~4 W with 80% power efficiency. The platform is capable of achieving triplex B-mode, M-mode, color, pulsed-wave Doppler mode imaging in real time. The hardware design files are available for researchers and engineers for further study, improvement or rapid commercialization of ultrasound smart probes to fight COVID-19.
- 4 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (4) , 1296-1304
A Programmable Platform for Accelerating the Development of Smart Ultrasound Transducer Probe
During the COVID-19 pandemic, an ultra-portable ultrasound smart probe has proven to be one of the few practical diagnostic and monitoring tools for doctors who are fully covered with personal protective equipment. The real-time, safety, ease of sanitization and ultra-portability features of an ultrasound smart probe make it extreme suitable for diagnosing COVID-19. In this paper, we discuss the implementation of a smart probe designed according to the classic architecture of ultrasound scanners. The design balanced both performance and power consumption. This programmable platform for an ultrasound smart probe supports a 64-channel full digital beamformer. The platform’s size is smaller than 10 cm by 5 cm. It achieves a 60-dBFS signal-to-noise ratio (SNR) and an average power consumption of ~4 W with 80% power efficiency. The platform is capable of achieving triplex B-mode, M-mode, color, pulsed-wave Doppler mode imaging in real time. The hardware design files are available for researchers and engineers for further study, improvement or rapid commercialization of ultrasound smart probes to fight COVID-19.
- Open Access
Omni-tomography/Multi-tomography -- Integrating Multiple Modalities for Simultaneous Imaging
Current tomographic imaging systems need major improvements, especially when multi-dimensional, multi-scale, multi-temporal and multi-parametric phenomena are under investigation. Both preclinical and clinical imaging now depend on in vivo tomography, often requiring separate evaluations by different imaging modalities to define morphologic details, delineate interval changes due to disease or interventions, and study physiological functions that have interconnected aspects. Over the past decade, fusion of multimodality images has emerged with two different approaches: post-hoc image registration and combined acquisition on PET-CT, PET-MRI and other hybrid scanners. There are intrinsic limitations for both the post-hoc image analysis and dual/triple modality approaches defined by registration errors and physical constraints in the acquisition chain. We envision that tomography will evolve beyond current modality fusion and towards grand fusion, a large scale fusion of all or many imaging modalities, which may be referred to as omni-tomography or multi-tomography. Unlike modality fusion, grand fusion is here proposed for truly simultaneous but often localized reconstruction in terms of all or many relevant imaging mechanisms such as CT, MRI, PET, SPECT, US, optical, and possibly more. In this paper, the technical basis for omni-tomography is introduced and illustrated with a top-level design of a next generation scanner, interior tomographic reconstructions of representative modalities, and anticipated applications of omni-tomography.
Open AccessOmni-tomography/Multi-tomography -- Integrating Multiple Modalities for Simultaneous Imaging
Current tomographic imaging systems need major improvements, especially when multi-dimensional, multi-scale, multi-temporal and multi-parametric phenomena are under investigation. Both preclinical and clinical imaging now depend on in vivo tomography, often requiring separate evaluations by different imaging modalities to define morphologic details, delineate interval changes due to disease or interventions, and study physiological functions that have interconnected aspects. Over the past decade, fusion of multimodality images has emerged with two different approaches: post-hoc image registration and combined acquisition on PET-CT, PET-MRI and other hybrid scanners. There are intrinsic limitations for both the post-hoc image analysis and dual/triple modality approaches defined by registration errors and physical constraints in the acquisition chain. We envision that tomography will evolve beyond current modality fusion and towards grand fusion, a large scale fusion of all or many imaging modalities, which may be referred to as omni-tomography or multi-tomography. Unlike modality fusion, grand fusion is here proposed for truly simultaneous but often localized reconstruction in terms of all or many relevant imaging mechanisms such as CT, MRI, PET, SPECT, US, optical, and possibly more. In this paper, the technical basis for omni-tomography is introduced and illustrated with a top-level design of a next generation scanner, interior tomographic reconstructions of representative modalities, and anticipated applications of omni-tomography.