Seokjae Kim
Seokjae Kim has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Jong-Oh Park
Korea Institute of Medical Microrobotics, Gwangju 61011, Republic of Korea
5 shared publications - Eunpyo Choi
Department of Mechanical Engineering, Sogang University, 35, Baekbeom-ro, Mapo-gu, Seoul 04107, Republic of Korea
4 shared publications - Doyeon Bang
Department of AI Convergence, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Republic of Korea
3 shared publications - Gwangjun Go
Korea Institute of Medical Microrobotics, 43-26, Cheomdangwagi-ro 208-beon-gil, Buk-gu, Gwangju 61011, Republic of Korea
3 shared publications - Junhyeok Lee
Korea Institute of Medical Microrobotics, 43–26, Cheomdangwagi-ro 208-beon-gil, Buk-gu, Gwangju 61011, Republic of Korea
3 shared publications - Minghui Nan
Robot Research Initiative, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Republic of Korea
3 shared publications
Latest Publications
- Open Access
- 21 June 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (7) , 726
Parametric Rule-Based Intelligent System (PRISM) for Design and Analysis of High-Strength Separable Microneedles
Transdermal microneedle systems have received great attention due to their minimally invasive way of delivering biomolecules through the skin with reduced pain. However, designing high-strength separable microneedles, which enable easy skin penetration and easy patch detachment, is challenging. Here, we present a Parametric Rule-based Intelligent System (PRISM), which generates the design of and analyzes high-strength separable microneedles. The PRISM platform integrates parametric 3D modeling, geometry-based structural analysis, and high-resolution micro-3D printing for the creation of high-strength separable microneedles. We fabricated prototype microneedle arrays via microscale stereolithographic printing (pµSL) and demonstrated separation of microneedle tips in a skin-mimicking phantom sample. Mechanical testing showed that the suggested design achieved 2.13 ± 0.51 N axial resistance and 73.92 ± 34.77 mN shear fracture force; this surpasses that of conventional designs. Finally, an experiment using a skin-mimicking artificial phantom sample confirmed that only the PRISM-designed separable microneedles could have been inserted and separated at the target depth, whereas conventional designs failed to detach. This approach addresses the development of microneedle systems, which achieve both robust skin phantom penetration and reliable separable delivery, presenting an efficient development tool in transdermal drug delivery technology.
- 21 June 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (7) , 726
Open AccessParametric Rule-Based Intelligent System (PRISM) for Design and Analysis of High-Strength Separable Microneedles
Transdermal microneedle systems have received great attention due to their minimally invasive way of delivering biomolecules through the skin with reduced pain. However, designing high-strength separable microneedles, which enable easy skin penetration and easy patch detachment, is challenging. Here, we present a Parametric Rule-based Intelligent System (PRISM), which generates the design of and analyzes high-strength separable microneedles. The PRISM platform integrates parametric 3D modeling, geometry-based structural analysis, and high-resolution micro-3D printing for the creation of high-strength separable microneedles. We fabricated prototype microneedle arrays via microscale stereolithographic printing (pµSL) and demonstrated separation of microneedle tips in a skin-mimicking phantom sample. Mechanical testing showed that the suggested design achieved 2.13 ± 0.51 N axial resistance and 73.92 ± 34.77 mN shear fracture force; this surpasses that of conventional designs. Finally, an experiment using a skin-mimicking artificial phantom sample confirmed that only the PRISM-designed separable microneedles could have been inserted and separated at the target depth, whereas conventional designs failed to detach. This approach addresses the development of microneedle systems, which achieve both robust skin phantom penetration and reliable separable delivery, presenting an efficient development tool in transdermal drug delivery technology.
- Open Access
- 11 February 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (2) , 434
Magnetically Actuated Microscaffold with Controllable Magnetization and Morphology for Regeneration of Osteochondral Tissue
Magnetic microscaffolds capable of targeted cell delivery have been developed for tissue regeneration. However, the microscaffolds developed so far with similar morphologies have limitations for applications to osteochondral disease, which requires simultaneous treatment of the cartilage and subchondral bone. This study proposes magnetically actuated microscaffolds tailored to the cartilage and subchondral bone for osteochondral tissue regeneration, named magnetically actuated microscaffolds for cartilage regeneration (MAM-CR) and for subchondral bone regeneration (MAM-SBR). The morphologies of the microscaffolds were controlled using a double emulsion and microfluidic flow. In addition, due to their different sizes, MAM-CR and MAM-SBR have different magnetizations because of the different amounts of magnetic nanoparticles attached to their surfaces. In terms of biocompatibility, both microscaffolds were shown to grow cells without toxicity as potential cell carriers. In magnetic actuation tests of the microscaffolds, the relatively larger MAM-SBR moved faster than the MAM-CR under the same magnetic field strength. In a feasibility test, the magnetic targeting of the microscaffolds in 3D knee cartilage phantoms showed that the MAM-SBR and MAM-CR were sequentially moved to the target sites. Thus, the proposed magnetically actuated microscaffolds provide noninvasive treatment for osteochondral tissue disease.
- 11 February 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (2) , 434
Open AccessMagnetically Actuated Microscaffold with Controllable Magnetization and Morphology for Regeneration of Osteochondral Tissue
Magnetic microscaffolds capable of targeted cell delivery have been developed for tissue regeneration. However, the microscaffolds developed so far with similar morphologies have limitations for applications to osteochondral disease, which requires simultaneous treatment of the cartilage and subchondral bone. This study proposes magnetically actuated microscaffolds tailored to the cartilage and subchondral bone for osteochondral tissue regeneration, named magnetically actuated microscaffolds for cartilage regeneration (MAM-CR) and for subchondral bone regeneration (MAM-SBR). The morphologies of the microscaffolds were controlled using a double emulsion and microfluidic flow. In addition, due to their different sizes, MAM-CR and MAM-SBR have different magnetizations because of the different amounts of magnetic nanoparticles attached to their surfaces. In terms of biocompatibility, both microscaffolds were shown to grow cells without toxicity as potential cell carriers. In magnetic actuation tests of the microscaffolds, the relatively larger MAM-SBR moved faster than the MAM-CR under the same magnetic field strength. In a feasibility test, the magnetic targeting of the microscaffolds in 3D knee cartilage phantoms showed that the MAM-SBR and MAM-CR were sequentially moved to the target sites. Thus, the proposed magnetically actuated microscaffolds provide noninvasive treatment for osteochondral tissue disease.
- Open Access
- 24 January 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (2) , 184
Wearable Localized Surface Plasmon Resonance-Based Biosensor with Highly Sensitive and Direct Detection of Cortisol in Human Sweat
Wearable biosensors have the potential for developing individualized health evaluation and detection systems owing to their ability to provide continuous real-time physiological data. Among various wearable biosensors, localized surface plasmon resonance (LSPR)-based wearable sensors can be versatile in various practical applications owing to their sensitive interactions with specific analytes. Understanding and analyzing endocrine responses to stress is particularly crucial for evaluating human performance, diagnosing stress-related diseases, and monitoring mental health, as stress takes a serious toll on physiological health and psychological well-being. Cortisol is an essential biomarker of stress because of the close relationship between cortisol concentration in the human body and stress level. In this study, a flexible LSPR biosensor was manufactured to detect cortisol levels in the human body by depositing gold nanoparticle (AuNP) layers on a 3-aminopropyltriethoxysilane (APTES)-functionalized poly (dimethylsiloxane) (PDMS) substrate. Subsequently, an aptamer was immobilized on the surface of the LSPR substrate, enabling highly sensitive and selective cortisol capture owing to its specific cortisol recognition. The biosensor exhibited excellent detection ability in cortisol solutions of various concentrations ranging from 0.1 to 1000 nM with a detection limit of 0.1 nM. The flexible LSPR biosensor also demonstrated good stability under various mechanical deformations. Furthermore, the cortisol levels of the flexible LSPR biosensor were also measured in the human epidermis before and after exercise as well as in the morning and afternoon. Our biosensors, which combine easily manufactured flexible sensors with sensitive cortisol-detecting molecules to measure human stress levels, could be versatile candidates for human-friendly products.
- 24 January 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (2) , 184
Open AccessWearable Localized Surface Plasmon Resonance-Based Biosensor with Highly Sensitive and Direct Detection of Cortisol in Human Sweat
Wearable biosensors have the potential for developing individualized health evaluation and detection systems owing to their ability to provide continuous real-time physiological data. Among various wearable biosensors, localized surface plasmon resonance (LSPR)-based wearable sensors can be versatile in various practical applications owing to their sensitive interactions with specific analytes. Understanding and analyzing endocrine responses to stress is particularly crucial for evaluating human performance, diagnosing stress-related diseases, and monitoring mental health, as stress takes a serious toll on physiological health and psychological well-being. Cortisol is an essential biomarker of stress because of the close relationship between cortisol concentration in the human body and stress level. In this study, a flexible LSPR biosensor was manufactured to detect cortisol levels in the human body by depositing gold nanoparticle (AuNP) layers on a 3-aminopropyltriethoxysilane (APTES)-functionalized poly (dimethylsiloxane) (PDMS) substrate. Subsequently, an aptamer was immobilized on the surface of the LSPR substrate, enabling highly sensitive and selective cortisol capture owing to its specific cortisol recognition. The biosensor exhibited excellent detection ability in cortisol solutions of various concentrations ranging from 0.1 to 1000 nM with a detection limit of 0.1 nM. The flexible LSPR biosensor also demonstrated good stability under various mechanical deformations. Furthermore, the cortisol levels of the flexible LSPR biosensor were also measured in the human epidermis before and after exercise as well as in the morning and afternoon. Our biosensors, which combine easily manufactured flexible sensors with sensitive cortisol-detecting molecules to measure human stress levels, could be versatile candidates for human-friendly products.
- Open Access
- 6 November 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (11) , 2393
Microrobot with Gyroid Surface and Gold Nanostar for High Drug Loading and Near-Infrared-Triggered Chemo-Photothermal Therapy
The use of untethered microrobots for precise synergistic anticancer drug delivery and controlled release has attracted attention over the past decade. A high surface area of the microrobot is desirable to achieve greater therapeutic effect by increasing the drug load. Therefore, various nano- or microporous microrobot structures have been developed to load more drugs. However, as most porous structures are not interconnected deep inside, the drug-loading efficiency may be reduced. Here, we propose a magnetically guided helical microrobot with a Gyroid surface for high drug-loading efficiency and precise drug delivery. All spaces inside the proposed microrobot are interconnected, thereby enabling drug loading deep inside the structure. Moreover, we introduce gold nanostars on the microrobot structure for near-infrared-induced photothermal therapy and triggering drug release. The results of this study encourage further exploration of a high loading efficiency in cell-based therapeutics, such as stem cells or immune cells, for microrobot-based drug-delivery systems.
- 6 November 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (11) , 2393
Open AccessMicrorobot with Gyroid Surface and Gold Nanostar for High Drug Loading and Near-Infrared-Triggered Chemo-Photothermal Therapy
The use of untethered microrobots for precise synergistic anticancer drug delivery and controlled release has attracted attention over the past decade. A high surface area of the microrobot is desirable to achieve greater therapeutic effect by increasing the drug load. Therefore, various nano- or microporous microrobot structures have been developed to load more drugs. However, as most porous structures are not interconnected deep inside, the drug-loading efficiency may be reduced. Here, we propose a magnetically guided helical microrobot with a Gyroid surface for high drug-loading efficiency and precise drug delivery. All spaces inside the proposed microrobot are interconnected, thereby enabling drug loading deep inside the structure. Moreover, we introduce gold nanostars on the microrobot structure for near-infrared-induced photothermal therapy and triggering drug release. The results of this study encourage further exploration of a high loading efficiency in cell-based therapeutics, such as stem cells or immune cells, for microrobot-based drug-delivery systems.
- Open Access
- 15 October 2021
- Published by MDPI AG in Pharmaceutics
- Vol. 13 (10) , 1689
Sonazoid-Conjugated Natural Killer Cells for Tumor Therapy and Real-Time Visualization by Ultrasound Imaging
Various cell therapy strategies, including chimeric antigen receptor-expressing T or natural killer (NK) cells and cell-mediated drug delivery, have been developed for tumor eradication. However, the efficiency of these strategies against solid tumors remains unclear. We hypothesized that real-time control and visualization of therapeutic cells, such as NK cells, would improve their therapeutic efficacy against solid tumors. In this study, we engineered Sonazoid microbubble-conjugated NK (NK_Sona) cells and demonstrated that they were detectable by ultrasound imaging in real-time and maintained their functions. The Sonazoid microbubbles on the cell membrane did not affect the cytotoxicity and viability of the NK cells in vitro. Additionally, the NK_Sona cells could be visualized by ultrasound imaging and inhibited tumor growth in vivo. Taken together, our findings demonstrate the feasibility of this new approach in the use of therapeutic cells, such as NK cells, against solid tumors.
- 15 October 2021
- Published by MDPI AG in Pharmaceutics
- Vol. 13 (10) , 1689
Open AccessSonazoid-Conjugated Natural Killer Cells for Tumor Therapy and Real-Time Visualization by Ultrasound Imaging
Various cell therapy strategies, including chimeric antigen receptor-expressing T or natural killer (NK) cells and cell-mediated drug delivery, have been developed for tumor eradication. However, the efficiency of these strategies against solid tumors remains unclear. We hypothesized that real-time control and visualization of therapeutic cells, such as NK cells, would improve their therapeutic efficacy against solid tumors. In this study, we engineered Sonazoid microbubble-conjugated NK (NK_Sona) cells and demonstrated that they were detectable by ultrasound imaging in real-time and maintained their functions. The Sonazoid microbubbles on the cell membrane did not affect the cytotoxicity and viability of the NK cells in vitro. Additionally, the NK_Sona cells could be visualized by ultrasound imaging and inhibited tumor growth in vivo. Taken together, our findings demonstrate the feasibility of this new approach in the use of therapeutic cells, such as NK cells, against solid tumors.