IJIroshani Jayawardene

Iroshani Jayawardene

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Iroshani Jayawardene has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Synthetic data generation for electric vehicle charging

    by Magdalena Skrzycki, Iroshani Jayawardene, Xiaodong Cheng, Manya Afonso, Xiang Ma, Dumitru Roman

  • Open Access

    Synthetic Data Generation for Electric Vehicle Charging

    by Magdalena Skrzycki, Iroshani Jayawardene, Xiaodong Cheng, Manya Afonso, Xiang Ma, Dumitru Roman

    The rapid adoption of electric vehicles (EVs) creates new challenges for energy systems due to growing residential charging demand. Effective grid management requires detailed charging data, yet publicly available session-level datasets remain scarce. This study develops a conditional diffusion model to generate synthetic residential EV charging sessions conditioned on season, weekday group, and location group. The proposed model is benchmarked against an extended Conditional Tabular Generative Adversarial Network (CTGAN). Final model performance is evaluated across four residential location groups and reported as mean $\pm$ standard deviation. After Holm--Bonferroni correction, the diffusion model showed significant improvements for six of eight yearly distributional metrics, while connection-time differences were better interpreted as descriptive mean advantages and reduced variability. For aggregate load-profile reconstruction, the models showed complementary strengths: diffusion better reproduced the mean daily load curve, whereas CTGAN achieved lower errors for peak- and variability-related metrics under the simplified load-reconstruction assumption. The findings indicate that conditional synthetic charging sessions can support indicative scenario construction and downstream energy-system analysis, while detailed charging dynamics and dependency preservation require further validation.

  • Open Access

    Comparative analysis and trends in performance of identical PV panels under different climatic conditions

    by Iroshani Jayawardene, Dumitru Roman, Xiang Ma, Alessandro Liberale, Alicia Arce, Alfredo Gonzalez Naranjo, Rafael Martin Salinas, Rebeca Gutierrez, Hélène Ben Khemis, Zaher Khantouch, et al.


  • Open Access

    Resilient and Sustainable Tie-Line Bias Control for a Power System in Uncertain Environments

    by Iroshani Jayawardene, Ganesh Kumar Venayagamoorthy, Xingsi Zhong

    Interconnected power systems with large-scale penetration of photovoltaic (PV) power introduce frequency and tie-line power flow fluctuations. This is due to the variability and uncertainty characteristics of PV power. This makes automatic generation control (AGC) to be more challenging. In other words, maintaining system frequencies and tie-line power flows at the desired values, also known as “tie-line bias control” is difficult. In this paper, an enhanced tie-line bias control method is proposed by predicting PV power generation and bus frequencies. A cyber-physical two-area power system with a large PV plant consisting of phasor measurement units (PMUs) is studied. The use of synchrophasor networks consisting of PMUs can enable smooth power system operations overcoming the challenges of PV power variability and uncertainty. However, the use of PMUs in power system control creates vulnerabilities for cyber-attacks that could jeopardize the power system operations. It is shown that the frequency prediction using a virtual synchrophasor network (VSN) can mitigate the impact(s) of denial of service (DoS) attacks on physical PMUs. Enhanced AGC performance is investigated under different weather and load conditions including a weather profile during the “Great American Eclipse” of August $21^{st}, 2017$ . Typical results indicate that the enhanced AGC structure provides a resilient and sustainable tie-line bias control in uncertain environments.


  • Cellular computational extreme learning machine network based frequency predictions in a power system

    by Iroshani Jayawardene, Ganesh K. Venayagamoorthy

    Frequency is one of the most important characteristics in power system monitoring, control and protection. Frequency variations can be observed with significant changes in operating conditions. High penetration levels of renewable energy pose variability and uncertainty challenges for grid operation. It is essential to have innovative methodologies to take necessary actions to overcome these challenges. Power system frequency prediction provides an insight to better system control and protection. In this paper, a cellular computational extreme learning machine network (CCELMN) based frequency prediction approach is presented. Results are compared with those obtained with independent ELM models and persistence model and shown to outperform.


  • Situational intelligence for online coherency analysis of synchronous generators in power system

    by Yawei Wei, Iroshani Jayawardene, Paranietharan Arunagirinathan, Ke Tang, Ganesh Kumar Venayagamoorthy

    This paper presents a situational intelligence (SI) based approach to carry out coherency analysis of synchronous generator in a power system in an online manner. A cellular computational network (CCN) is used as the SI algorithm. CCN is a framework for distributed multi-timescale frequency prediction by utilizing the local and neighboring phasor measurement units (PMUs). The predicted frequency values are utilized for coherency analysis. The advantages of the CCN are scalability and distributedness which caters for on-line predicted coherency analysis for large power systems. The multi-time scale frequency predictions mitigates or minimizes delays in power system measurements and provides an insight to the power system coherent behavior apriori. The simulation studies on the New York-New England IEEE benchmark power system are presented to demonstrate that CCN based SI can be utilized in online coherency analysis. Predicted measurements can enhance resiliency to bad data. Furthermore, it is possible to utilize this approach for adaptive control of wide area power systems.