Birgit Schachler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Birgit Schachler has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Guido Pleßmann
Reiner Lemoine Institut gGmbH Rudower Chaussee 12 12489 Berlin Germany
2 shared publications - Julian Bartels
DLR–Institut für Vernetzte Energiesysteme e.V., Carl-von-Ossietzky-Str. 15, 26129 Oldenburg, Germany
2 shared publications - Malte Scharf
Centre for Sustainable Energy Systems, Europa-Universität Flensburg, Auf dem Campus 1, 24943 Flensburg, Germany
2 shared publications - Stephan Günther
Institute for Intelligent Cooperative Systems, Otto-von-Guericke-University Magdeburg, Postfach 4120, 39016 Magdeburg, Germany
2 shared publications - Ulf Philipp Müller
Centre for Sustainable Energy Systems, Flensburg University of Applied Sciences, Kanzleistraße 91-93, 24943 Flensburg, Germany
2 shared publications - Wolf-Dieter Bunke
Centre for Sustainable Energy Systems, Europa-Universität Flensburg, Auf dem Campus 1, 24943 Flensburg, Germany
2 shared publications
Latest Publications
- Open Access
- 2 December 2025
- Published by IOP Publishing in Environmental Research: Energy
- Vol. 2 (4)
Challenges of top-down flexibility deployment for grid expansion across all voltage levels
The energy transition in Germany demands a comprehensive transformation of electricity grids at all levels, making them central to the achievement of climate goals and the integration of renewable energy in all energy sectors. However, grid infrastructure currently represents a critical bottleneck. In particular, the role of medium and low voltage grids is changing. Historically designed to distribute electricity from the transmission system to demands, medium and low voltage grids must now adapt to accommodate distributed generation, increased flexibility, and new demands driven by sector coupling. Flexibility options, such as demand response and energy storage, offer potential solutions, but their efficient deployment requires optimized coordination. In order to contribute to the identification of an effective coordination strategy, the open-source tool eGo has been developed. The objective is to quantify the expansion needs of the grid at all levels in Germany, considering flexibility options from the sectors electricity, heat, gas, and mobility using a top-down approach. The method is applied to a mid-term scenario depicting the year 2035. The results show that while top-down dispatch optimization is effective for extra-high and high voltage grids, it can exacerbate expansion requirements in medium and low voltage grids. As a result, flexibility options can reduce system costs by only 1 %, taking into account the need for expansion at all grid levels. The curtailment of intermittent renewables can be significantly reduced by 71 %. Coordinated dispatch across grid operators and levels is therefore essential to fully leverage flexibility options, ensuring that the energy transition proceeds efficiently across the entire electricity grid.
- 2 December 2025
- Published by IOP Publishing in Environmental Research: Energy
- Vol. 2 (4)
Open AccessChallenges of top-down flexibility deployment for grid expansion across all voltage levels
The energy transition in Germany demands a comprehensive transformation of electricity grids at all levels, making them central to the achievement of climate goals and the integration of renewable energy in all energy sectors. However, grid infrastructure currently represents a critical bottleneck. In particular, the role of medium and low voltage grids is changing. Historically designed to distribute electricity from the transmission system to demands, medium and low voltage grids must now adapt to accommodate distributed generation, increased flexibility, and new demands driven by sector coupling. Flexibility options, such as demand response and energy storage, offer potential solutions, but their efficient deployment requires optimized coordination. In order to contribute to the identification of an effective coordination strategy, the open-source tool eGo has been developed. The objective is to quantify the expansion needs of the grid at all levels in Germany, considering flexibility options from the sectors electricity, heat, gas, and mobility using a top-down approach. The method is applied to a mid-term scenario depicting the year 2035. The results show that while top-down dispatch optimization is effective for extra-high and high voltage grids, it can exacerbate expansion requirements in medium and low voltage grids. As a result, flexibility options can reduce system costs by only 1 %, taking into account the need for expansion at all grid levels. The curtailment of intermittent renewables can be significantly reduced by 71 %. Coordinated dispatch across grid operators and levels is therefore essential to fully leverage flexibility options, ensuring that the energy transition proceeds efficiently across the entire electricity grid.
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 2001-2010
On the Integration of Electric Vehicles Into German Distribution Grids Through Smart Charging
Efforts to decarbonise the transport sector lead to an increasing share of electric vehicles (EVs), which can significantly stress future distribution grids. The level of stress thereby not only depends on the number of integrated EVs but also the existing topology of the grid and present shares of supply and demand units. We therefore examine the influence of different charging strategies on distinct distribution grid types, namely PV-, wind- and load-dominated grids, and compare the effects on curtailment needs and reinforcement costs. With the help of a quadratic problem formulation, including linearised AC power flow constraints, we deduce optimised charging profiles to minimise the additional stress on the grids. We compare the results to rule-based charging strategies to extract suggestions for the effective integration of EVs. Our analysis shows that the potential of the examined charging strategies to decrease curtailment necessary to solve arising grid issues is limited. However, the additional grid expansion costs caused by EV integration, which mainly occur in the low voltage, can be reduced significantly compared to reference charging, where EV charging is mostly uncontrolled. The optimised charging strategy reduces the total reinforcement costs by 59 %, a reduced charging by 57 % and a residual load based charging by 5 % compared to the reference charging over all investigated grids. Our results also show that the charging strategies prove to be differently useful in the different types of grids. This stresses the importance of considering various grid topologies when investigating the influence of smart charging on distribution grids
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 2001-2010
On the Integration of Electric Vehicles Into German Distribution Grids Through Smart Charging
Efforts to decarbonise the transport sector lead to an increasing share of electric vehicles (EVs), which can significantly stress future distribution grids. The level of stress thereby not only depends on the number of integrated EVs but also the existing topology of the grid and present shares of supply and demand units. We therefore examine the influence of different charging strategies on distinct distribution grid types, namely PV-, wind- and load-dominated grids, and compare the effects on curtailment needs and reinforcement costs. With the help of a quadratic problem formulation, including linearised AC power flow constraints, we deduce optimised charging profiles to minimise the additional stress on the grids. We compare the results to rule-based charging strategies to extract suggestions for the effective integration of EVs. Our analysis shows that the potential of the examined charging strategies to decrease curtailment necessary to solve arising grid issues is limited. However, the additional grid expansion costs caused by EV integration, which mainly occur in the low voltage, can be reduced significantly compared to reference charging, where EV charging is mostly uncontrolled. The optimised charging strategy reduces the total reinforcement costs by 59 %, a reduced charging by 57 % and a residual load based charging by 5 % compared to the reference charging over all investigated grids. Our results also show that the charging strategies prove to be differently useful in the different types of grids. This stresses the importance of considering various grid topologies when investigating the influence of smart charging on distribution grids
- Open Access
- 28 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 36 (5) , 3830-3839
Techno-Economic Assessment of Flexibility Options Versus Grid Expansion in Distribution Grids
In this paper five different flexibility options are analysed from a techno-economic perspective as alternatives to traditional grid expansion for a specific distribution grid in Germany. The options are: two reactive power control strategies with photovoltaic inverters (as a function of the power feed-in, or of the voltage at the connection point), one residential and two large scale battery storage applications (primary control reserve with autonomous reactive power control or self consumption maximisation strategy with autonomous reactive power control). For the pilot grid located in Southern Germany a photovoltaic expansion pathway is determined. The main goal of this work is to quantify the grid expansion actions that can be avoided by applying these five flexibility options for the assumed expansion pathway, focusing on large scale battery storages. It is shown that the five flexibility options increase the hosting capacity for PV systems, compared to a scenario without, by up to 45%. Furthermore, the results of the economic assessment indicate that the analysed flexibility options might be a viable alternative to traditional grid expansion as all of them show a cost reduction potential for the pilot region. These results could encourage DSOs to consider the integration of additional PV and battery storage systems not as a problem which triggers grid expansion, but as part of the solution reducing future grid expansion costs.
- 28 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 36 (5) , 3830-3839
Open AccessTechno-Economic Assessment of Flexibility Options Versus Grid Expansion in Distribution Grids
In this paper five different flexibility options are analysed from a techno-economic perspective as alternatives to traditional grid expansion for a specific distribution grid in Germany. The options are: two reactive power control strategies with photovoltaic inverters (as a function of the power feed-in, or of the voltage at the connection point), one residential and two large scale battery storage applications (primary control reserve with autonomous reactive power control or self consumption maximisation strategy with autonomous reactive power control). For the pilot grid located in Southern Germany a photovoltaic expansion pathway is determined. The main goal of this work is to quantify the grid expansion actions that can be avoided by applying these five flexibility options for the assumed expansion pathway, focusing on large scale battery storages. It is shown that the five flexibility options increase the hosting capacity for PV systems, compared to a scenario without, by up to 45%. Furthermore, the results of the economic assessment indicate that the analysed flexibility options might be a viable alternative to traditional grid expansion as all of them show a cost reduction potential for the pilot region. These results could encourage DSOs to consider the integration of additional PV and battery storage systems not as a problem which triggers grid expansion, but as part of the solution reducing future grid expansion costs.
- Open Access
Integrated Techno-Economic Power System Planning of Transmission and Distribution Grids
The energy transition towards renewable and more distributed power production triggers the need for grid and storage expansion on all voltage levels. Today’s power system planning focuses on certain voltage levels or spatial resolutions. In this work we present an open source software tool eGo which is able to optimize grid and storage expansion throughout all voltage levels in a developed top-down approach. Operation and investment costs are minimized by applying a multi-period linear optimal power flow considering the grid infrastructure of the extra-high and high-voltage (380 to 110 kV) level. Hence, the common differentiation of transmission and distribution grid is partly dissolved, integrating the high-voltage level into the optimization problem. Consecutively, optimized curtailment and storage units are allocated in the medium voltage grid in order to lower medium and low voltage grid expansion needs, that are consequently determined. Here, heuristic optimization methods using the non-linear power flow were developed. Applying the tool on future scenarios we derived cost-efficient grid and storage expansion for all voltage levels in Germany. Due to the integrated approach, storage expansion and curtailment can significantly lower grid expansion costs in medium and low voltage grids and at the same time serve the optimal functioning of the overall system. Nevertheless, the cost-reducing effect for the whole of Germany was marginal. Instead, the consideration of realistic, spatially differentiated time series led to substantial overall savings.
Open AccessIntegrated Techno-Economic Power System Planning of Transmission and Distribution Grids
The energy transition towards renewable and more distributed power production triggers the need for grid and storage expansion on all voltage levels. Today’s power system planning focuses on certain voltage levels or spatial resolutions. In this work we present an open source software tool eGo which is able to optimize grid and storage expansion throughout all voltage levels in a developed top-down approach. Operation and investment costs are minimized by applying a multi-period linear optimal power flow considering the grid infrastructure of the extra-high and high-voltage (380 to 110 kV) level. Hence, the common differentiation of transmission and distribution grid is partly dissolved, integrating the high-voltage level into the optimization problem. Consecutively, optimized curtailment and storage units are allocated in the medium voltage grid in order to lower medium and low voltage grid expansion needs, that are consequently determined. Here, heuristic optimization methods using the non-linear power flow were developed. Applying the tool on future scenarios we derived cost-efficient grid and storage expansion for all voltage levels in Germany. Due to the integrated approach, storage expansion and curtailment can significantly lower grid expansion costs in medium and low voltage grids and at the same time serve the optimal functioning of the overall system. Nevertheless, the cost-reducing effect for the whole of Germany was marginal. Instead, the consideration of realistic, spatially differentiated time series led to substantial overall savings.
- Open Access
- 26 April 2019
- Published by MDPI AG in Preprints.org
Integrated techno-economic power system planning of transmission and distribution grids
The energy transition towards renewable and more decentral power production triggers the need for grid and storage expansion on all voltage levels. Today's power system planning focuses on certain voltage levels or spatial resolutions. In this work we present an open source software tool eGo which is able to optimize grid and storage expansion throughout all voltage levels in a developed top-down approach. System costs are minimized by applying a linear optimal power flow considering the grid infrastructure of the extra-high and high-voltage (380 to 110 kV) level. Hence, the common differentiation of transmission and distribution grid is partly dissolved, integrating the high-voltage level into the optimization problem. Consecutively, optimized curtailment and storage units are allocated in the medium voltage grid in order to lower medium and low voltage grid expansion needs, that are consequently determined. Here, heuristic optimization methods using the non-linear power flow were developed. Applying the tool on future scenarios we derived cost-efficient grid and storage expansion for all voltage levels in Germany. Due to the integrated approach storage expansion and curtailment can significantly lower grid expansion costs in medium and low voltage grids and at the same time serve the optimal functioning of the overall system. Nevertheless, the cost-reducing effect for the whole of Germany was marginal. Instead, the consideration of realistic, spatially differentiated time series lead to substantial overall savings.
- 26 April 2019
- Published by MDPI AG in Preprints.org
Open AccessIntegrated techno-economic power system planning of transmission and distribution grids
The energy transition towards renewable and more decentral power production triggers the need for grid and storage expansion on all voltage levels. Today's power system planning focuses on certain voltage levels or spatial resolutions. In this work we present an open source software tool eGo which is able to optimize grid and storage expansion throughout all voltage levels in a developed top-down approach. System costs are minimized by applying a linear optimal power flow considering the grid infrastructure of the extra-high and high-voltage (380 to 110 kV) level. Hence, the common differentiation of transmission and distribution grid is partly dissolved, integrating the high-voltage level into the optimization problem. Consecutively, optimized curtailment and storage units are allocated in the medium voltage grid in order to lower medium and low voltage grid expansion needs, that are consequently determined. Here, heuristic optimization methods using the non-linear power flow were developed. Applying the tool on future scenarios we derived cost-efficient grid and storage expansion for all voltage levels in Germany. Due to the integrated approach storage expansion and curtailment can significantly lower grid expansion costs in medium and low voltage grids and at the same time serve the optimal functioning of the overall system. Nevertheless, the cost-reducing effect for the whole of Germany was marginal. Instead, the consideration of realistic, spatially differentiated time series lead to substantial overall savings.