Yuchen Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yuchen Zhang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Shiqiang Hou
Laboratory of Power System Operation and Analysis, School of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin, China
2 shared publications Shulei Xue
Laboratory of Power System Operation and Analysis, School of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin, China
2 shared publicationsYanling Lv
School of electrical and electronic engineering, Harbin University of Science and Technology, Harbin, China
2 shared publications- Yanling Lyu
Laboratory of Power System Operation and Analysis, School of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin, China
2 shared publications A. Chakma
University of Calgary
1 shared publication- Brij B. Maini
Department of Chemical and Petroleum Engineering, Schulich School of Engineering, University of Calgary, 2500 University Drive NW, Calgary, AB T2N 1N4, Canada
1 shared publication
Latest Publications
- Open Access
- 5 August 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 181
Bi-level day-ahead dispatch framework for full-timescale control ancillary services provision by heterogeneous electric vehicle clusters
- 5 August 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 181
Open AccessBi-level day-ahead dispatch framework for full-timescale control ancillary services provision by heterogeneous electric vehicle clusters
- 6 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-13
Chaos Suppression Based on Fractional-Order Model in a Doubly-Fed Induction Generator
Chaotic oscillations in doubly-fed induction generator (DFIG) systems, caused by strong nonlinear coupling and parameter uncertainties, pose significant risks to power system stability. Although increasing evidence indicates that electromechanical systems exhibit fractional-order characteristics, most existing chaos suppression methods are developed within an integer-order framework, leading to inherent modeling mismatch and limited decoupling accuracy in fractional-order systems. Based on Caputo’s fractional-order calculus, fractional-order operators are incorporated into the traditional interactor algorithm, thereby enabling the development of a fractional-order interactor. This framework enables the construction of a fractional-order pseudolinear model and a corresponding fractional-order internal model, thereby facilitating effective system decoupling. On this basis, a fractional-order internal model control strategy is developed for chaos suppression. The effectiveness of the proposed approach is validated through numerical simulations and hardware-in-the-loop experiments on a fractional-order DFIG system under different fractional orders. The proposed control strategy can be readily extended to the decoupling and stabilization of other fractional-order nonlinear systems.
- 6 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-13
Chaos Suppression Based on Fractional-Order Model in a Doubly-Fed Induction Generator
Chaotic oscillations in doubly-fed induction generator (DFIG) systems, caused by strong nonlinear coupling and parameter uncertainties, pose significant risks to power system stability. Although increasing evidence indicates that electromechanical systems exhibit fractional-order characteristics, most existing chaos suppression methods are developed within an integer-order framework, leading to inherent modeling mismatch and limited decoupling accuracy in fractional-order systems. Based on Caputo’s fractional-order calculus, fractional-order operators are incorporated into the traditional interactor algorithm, thereby enabling the development of a fractional-order interactor. This framework enables the construction of a fractional-order pseudolinear model and a corresponding fractional-order internal model, thereby facilitating effective system decoupling. On this basis, a fractional-order internal model control strategy is developed for chaos suppression. The effectiveness of the proposed approach is validated through numerical simulations and hardware-in-the-loop experiments on a fractional-order DFIG system under different fractional orders. The proposed control strategy can be readily extended to the decoupling and stabilization of other fractional-order nonlinear systems.
- 2 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (2) , 911-927
Modeling and Chaos Dynamics Analysis of Doubly-Fed Induction Generator Based on Incommensurate Fractional-Order
The performance of complex doubly-fed induction generator (DFIG) systems is subject to the detrimental effects of chaotic dynamics. However, existing analyses of the chaotic states of DFIG systems ignore external excitations that can profoundly affect the operating state of the system, and integer-order models have been typically employed even though the inductance of DFIG systems has been demonstrated to have a fractional-order characteristic. The present work addresses these issues by conducting nonlinear dynamics analyses of an incommensurate fractional-order DFIG system according to different system operating parameters and model orders under external excitation conditions. Firstly, a fractional-order DFIG model is established with realistic parameters, and is transformed into a structure that greatly facilitates an analysis of its nonlinear dynamics by applying time-scale and affine transformations. The results of qualitative and quantitative analyses yield detailed descriptions of the nonlinear dynamics of the system under the action of multi-parameter coupling. Accordingly, the obtained analyses provide a theoretical basis and support for the design, operation, and control of DFIGs.
- 2 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (2) , 911-927
Modeling and Chaos Dynamics Analysis of Doubly-Fed Induction Generator Based on Incommensurate Fractional-Order
The performance of complex doubly-fed induction generator (DFIG) systems is subject to the detrimental effects of chaotic dynamics. However, existing analyses of the chaotic states of DFIG systems ignore external excitations that can profoundly affect the operating state of the system, and integer-order models have been typically employed even though the inductance of DFIG systems has been demonstrated to have a fractional-order characteristic. The present work addresses these issues by conducting nonlinear dynamics analyses of an incommensurate fractional-order DFIG system according to different system operating parameters and model orders under external excitation conditions. Firstly, a fractional-order DFIG model is established with realistic parameters, and is transformed into a structure that greatly facilitates an analysis of its nonlinear dynamics by applying time-scale and affine transformations. The results of qualitative and quantitative analyses yield detailed descriptions of the nonlinear dynamics of the system under the action of multi-parameter coupling. Accordingly, the obtained analyses provide a theoretical basis and support for the design, operation, and control of DFIGs.
- Open Access
- 30 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 148305-148314
Bifurcation and Chaotic Characterization of Incommensurate Fractional-Order Model for AC/DC Parallel Transmission System
This paper presents a novel investigation into the nonlinear dynamics of an AC/DC parallel transmission system through the development of an incommensurate fractional-order model. This model, incorporating Caputo’s fractional-order calculus, is specifically designed to analyze the fractional-order characteristics of the system. Numerical simulations are conducted under varying system parameters and model orders, producing bifurcation diagrams, spectra, phase diagrams, and dynamic parameter spaces using the 0-1 test. The findings reveal that changes in the fractional order significantly influence the size of chaotic attractors and the stability intervals of the system. Notably, a higher control gain in the excitation link triggers interior crises and expands chaotic attractors, while variations in the rectifier trigger lag angle result in merging, boundary, and interior crises. This research offers a new theoretical foundation for understanding and controlling bifurcation and chaos in AC/DC parallel transmission systems, thereby contributing to enhanced system stability and the design of control strategies.
- 30 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 148305-148314
Open AccessBifurcation and Chaotic Characterization of Incommensurate Fractional-Order Model for AC/DC Parallel Transmission System
This paper presents a novel investigation into the nonlinear dynamics of an AC/DC parallel transmission system through the development of an incommensurate fractional-order model. This model, incorporating Caputo’s fractional-order calculus, is specifically designed to analyze the fractional-order characteristics of the system. Numerical simulations are conducted under varying system parameters and model orders, producing bifurcation diagrams, spectra, phase diagrams, and dynamic parameter spaces using the 0-1 test. The findings reveal that changes in the fractional order significantly influence the size of chaotic attractors and the stability intervals of the system. Notably, a higher control gain in the excitation link triggers interior crises and expands chaotic attractors, while variations in the rectifier trigger lag angle result in merging, boundary, and interior crises. This research offers a new theoretical foundation for understanding and controlling bifurcation and chaos in AC/DC parallel transmission systems, thereby contributing to enhanced system stability and the design of control strategies.
- Open Access
- 17 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 71371-71378
Research on Centre of Inertia Based Frequency Sampling and System Frequency Distribution Characteristics
As the amount of new energy injected into the power system increases, the system inertia decreases and the spatio-temporal characteristics become apparent. Due to the uneven distribution of inertia in the power system, the dispersion of the frequency response after disturbance is more pronounced, and the inertia estimation error has a random nature when different frequency measurement points are selected. For the above problems, a method is proposed to select the frequency measurement point based on the centre of inertia. Firstly, based on the frequency dynamic response characteristics, the main influencing factors of the frequency distribution characteristics are studied and the spatial and temporal distribution characteristics of the frequency of the new energy power system are analyzed. Secondly, the method of frequency sampling through the centre of inertia is proposed with full consideration of the electrical distance and generator inertia constants. Finally, a 10 machine 39 bus system is simulated as an example. Simulation results show that using the centre of inertia as the frequency sampling point during inertia evaluation can reduce the inertia evaluation error by up to 16.15%. The results verify the correctness of the above theoretical analysis and provide a favourable basis for further improving the accuracy of the power system inertia estimation.
- 17 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 71371-71378
Open AccessResearch on Centre of Inertia Based Frequency Sampling and System Frequency Distribution Characteristics
As the amount of new energy injected into the power system increases, the system inertia decreases and the spatio-temporal characteristics become apparent. Due to the uneven distribution of inertia in the power system, the dispersion of the frequency response after disturbance is more pronounced, and the inertia estimation error has a random nature when different frequency measurement points are selected. For the above problems, a method is proposed to select the frequency measurement point based on the centre of inertia. Firstly, based on the frequency dynamic response characteristics, the main influencing factors of the frequency distribution characteristics are studied and the spatial and temporal distribution characteristics of the frequency of the new energy power system are analyzed. Secondly, the method of frequency sampling through the centre of inertia is proposed with full consideration of the electrical distance and generator inertia constants. Finally, a 10 machine 39 bus system is simulated as an example. Simulation results show that using the centre of inertia as the frequency sampling point during inertia evaluation can reduce the inertia evaluation error by up to 16.15%. The results verify the correctness of the above theoretical analysis and provide a favourable basis for further improving the accuracy of the power system inertia estimation.
- Open Access
- 7 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 139112-139120
Multivariate Cooperative Internal Mode Control of RBF Neural Network for Power System Chaos Suppression
In this paper, a multivariate cooperative internal mode control method based on RBF neural network (RBF-NN) inverse system is proposed to suppress the chaotic behavior in the power system. Firstly, a seven-dimensional model of the controlled power system including energy storage (ES) and static var compensator (SVC) is constructed, and the chaotic dynamics of the system is analyzed by local bifurcation diagram, attractor phase diagram and timing diagram, and the merging crisis and coexistence of chaotic attractors are found in the power system under the action of the low-frequency power disturbance. Secondly, considering the parameter uncertainties of the power system, an RBF-NN inverse system model of the controlled power system is established based on inverse system theory and neural network theory to realize its pseudo-linearization, and a multivariable cooperative internal mode controller is designed to suppress the chaotic behavior in the power system by combining the ES and the SVC. Finally, the effectiveness and robustness of the proposed chaos suppression control strategy are verified by simulation.
- 7 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 139112-139120
Open AccessMultivariate Cooperative Internal Mode Control of RBF Neural Network for Power System Chaos Suppression
In this paper, a multivariate cooperative internal mode control method based on RBF neural network (RBF-NN) inverse system is proposed to suppress the chaotic behavior in the power system. Firstly, a seven-dimensional model of the controlled power system including energy storage (ES) and static var compensator (SVC) is constructed, and the chaotic dynamics of the system is analyzed by local bifurcation diagram, attractor phase diagram and timing diagram, and the merging crisis and coexistence of chaotic attractors are found in the power system under the action of the low-frequency power disturbance. Secondly, considering the parameter uncertainties of the power system, an RBF-NN inverse system model of the controlled power system is established based on inverse system theory and neural network theory to realize its pseudo-linearization, and a multivariable cooperative internal mode controller is designed to suppress the chaotic behavior in the power system by combining the ES and the SVC. Finally, the effectiveness and robustness of the proposed chaos suppression control strategy are verified by simulation.
- 26 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 69 (12) , 4849-4853
Sliding Mode Control of Two-Parameter Fourth-Order Chaos Model of Power System
As a complex nonlinear system, the power system in operation may experience chaotic oscillation which can threaten the stability of the system for unexpected events and uncertain factors. Initially, through considering factors such as the generators, the power system node voltage amplitude and phase angle, this article establishes a fourth-order power system dynamic model and a two-parameter fourth-order power system mathematical model with load reactive power and mechanical input power as chaotic parameters to explore the mechanism and characteristics of chaos in the power system with the chaos theory. In addition, a sliding mode controller based on exponential reaching law for four state variables is designed, which is used to suppress the chaotic oscillation of the power system and guarantee the system can work stably at the target operating point within the chaotic parameter range. The designed controller can effectively suppress the chaos in power system and has an ideal performance.
- 26 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 69 (12) , 4849-4853
Sliding Mode Control of Two-Parameter Fourth-Order Chaos Model of Power System
As a complex nonlinear system, the power system in operation may experience chaotic oscillation which can threaten the stability of the system for unexpected events and uncertain factors. Initially, through considering factors such as the generators, the power system node voltage amplitude and phase angle, this article establishes a fourth-order power system dynamic model and a two-parameter fourth-order power system mathematical model with load reactive power and mechanical input power as chaotic parameters to explore the mechanism and characteristics of chaos in the power system with the chaos theory. In addition, a sliding mode controller based on exponential reaching law for four state variables is designed, which is used to suppress the chaotic oscillation of the power system and guarantee the system can work stably at the target operating point within the chaotic parameter range. The designed controller can effectively suppress the chaos in power system and has an ideal performance.
- 13 June 1999
- Published by Society of Petroleum Engineers (SPE)
Effects of Temperature On Foamy Oil Flow In Solution Gas-drive In Cold Lake Field
The roles of foamy oil flow in cold production of heavy oils under solution gas-drive have been extensively studied in recent years. However, the mechanisms of foamy oil flow in porous media are still not fully understood. The viscosities of heavy oils and bitumen are often so high that the solution gas drive should yield very little oil production. However, several heavy oil reservoirs in Canada and Venezuela have displayed very high solution gas drive recovery factors and foamy oil flow is believed to be the cause. The recovery factor projected for steam stimulation operation in Cold Lake is also very high, up to 30% of OOIP. Since the primary drive energy in Cold Lake comes from solution gas drive, it has been suggested that foamy oil flow may be responsible for this high recovery factor. The objective of this work was to examine the effects of temperature on foamy oil flow in a clean sand with Cold Lake oil and methane gas. Solution gas drive experiments were carried out in a sand-pack at several different temperatures and depletion rates. The results show that in isothermal depletion tests, the highest recovery factor does not occur at the highest temperature used. Instead, a much lower optimum temperature exists which provides the highest recovery. The reasons for this appear to be the diminished gas solubility and reduced foamy behaviour at higher temperatures, which counteract the positive influence of reduced viscosity Introduction: It has been found that an oil continuous foam is produced during primary production of heavy oil in several heavy oil reservoirs. Essentially the foam is formed by release of solution gas in the continuous oil phase. These foamy oils, because of their very complex structure, exhibit complicated and unusual flow behaviour. They exhibit not only remarkable rheological properties, but also very marked trapped gas effects, which in turn, may be responsible for the high primary oil recovery factor. In solution gas-drive process, the primary drive energy comes from the dissolved gas in the oil phase. The role of the dispersed gas bubbles in the oil displacement process has been studied for a long time by a number of investigators. The formation of dispersed gas bubbles in the heavy oil has been suggested to be an important factor contributing to the success in primary production of several heavy oil reservoirs. [1,2,3] Several investigators have reported the results of pressure depletion experiments. These results indicate that the beneficial effects of foamy oil diminish as the rate of pressure change becomes small. However, most previous work on foamy oil flow has been aimed at cold production, so that the temperature factor is not considered. Although some useful insights into the foamy oil flow mechanisms were developed, foamy oil flow in conjunction with thermal recovery methods has not been adequately studied. Maini and Nicola[4] have carried out laboratory scale solution gas-drive experiments to examine the effect of the rate of pressure change. Their results indicated that the solution gas-drive recovery factor increased dramatically as the rate of pressure decline was increased.
- 13 June 1999
- Published by Society of Petroleum Engineers (SPE)
Effects of Temperature On Foamy Oil Flow In Solution Gas-drive In Cold Lake Field
The roles of foamy oil flow in cold production of heavy oils under solution gas-drive have been extensively studied in recent years. However, the mechanisms of foamy oil flow in porous media are still not fully understood. The viscosities of heavy oils and bitumen are often so high that the solution gas drive should yield very little oil production. However, several heavy oil reservoirs in Canada and Venezuela have displayed very high solution gas drive recovery factors and foamy oil flow is believed to be the cause. The recovery factor projected for steam stimulation operation in Cold Lake is also very high, up to 30% of OOIP. Since the primary drive energy in Cold Lake comes from solution gas drive, it has been suggested that foamy oil flow may be responsible for this high recovery factor. The objective of this work was to examine the effects of temperature on foamy oil flow in a clean sand with Cold Lake oil and methane gas. Solution gas drive experiments were carried out in a sand-pack at several different temperatures and depletion rates. The results show that in isothermal depletion tests, the highest recovery factor does not occur at the highest temperature used. Instead, a much lower optimum temperature exists which provides the highest recovery. The reasons for this appear to be the diminished gas solubility and reduced foamy behaviour at higher temperatures, which counteract the positive influence of reduced viscosity Introduction: It has been found that an oil continuous foam is produced during primary production of heavy oil in several heavy oil reservoirs. Essentially the foam is formed by release of solution gas in the continuous oil phase. These foamy oils, because of their very complex structure, exhibit complicated and unusual flow behaviour. They exhibit not only remarkable rheological properties, but also very marked trapped gas effects, which in turn, may be responsible for the high primary oil recovery factor. In solution gas-drive process, the primary drive energy comes from the dissolved gas in the oil phase. The role of the dispersed gas bubbles in the oil displacement process has been studied for a long time by a number of investigators. The formation of dispersed gas bubbles in the heavy oil has been suggested to be an important factor contributing to the success in primary production of several heavy oil reservoirs. [1,2,3] Several investigators have reported the results of pressure depletion experiments. These results indicate that the beneficial effects of foamy oil diminish as the rate of pressure change becomes small. However, most previous work on foamy oil flow has been aimed at cold production, so that the temperature factor is not considered. Although some useful insights into the foamy oil flow mechanisms were developed, foamy oil flow in conjunction with thermal recovery methods has not been adequately studied. Maini and Nicola[4] have carried out laboratory scale solution gas-drive experiments to examine the effect of the rate of pressure change. Their results indicated that the solution gas-drive recovery factor increased dramatically as the rate of pressure decline was increased.