Saeed Montazeri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Saeed Montazeri has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Nathan J. Stevenson
Brain Modelling Group, QIMR Berghofer Medical Research Institute, Brisbane, QLD, Australia
4 shared publicationsSampsa Vanhatalo
BABA Center, Pediatric Research Centre, Department of Clinical Neurophysiology, Children's Hospital and HUS Diagnostic Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
4 shared publicationsManu Airaksinen
BABA Center, Pediatric Research Centre, Department of Clinical Neurophysiology, Children's Hospital and HUS Diagnostic Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
3 shared publicationsPäivi Nevalainen
BABA Center, Pediatric Research Centre, Department of Clinical Neurophysiology, Children's Hospital and HUS Diagnostic Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
3 shared publications- Päivi Nevalainen
Epilepsia Helsinki, Department of Clinical Neurophysiology, HUS Diagnostic Center, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
3 shared publications - Sampsa Vanhatalo
BABA Center, Pediatric Research Center, Departments of Physiology and Clinical Neurophysiology, New Children's Hospital, Helsinki University Hospital and University of Helsinki, Helsinki, Finland; and
3 shared publications
Latest Publications
- 11 November 2026
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
Artificial Intelligence-Based Neonatal Seizure Detection: A Pragmatic Evaluation of Clinical Performance Tradeoffs in Clinical EEG
Purpose: The aim of this study was to evaluate how three artificial intelligence (AI)-based neonatal seizure detectors (NSDs) perform in a large, clinically acquired data set and their potential to support timely seizure identification. Methods: We conducted a secondary analysis of continuous EEG (cEEG) recordings from 169 neonates born at ≥35 weeks gestation with neonatal encephalopathy. Seizure presence was determined by independent review by two or three pediatric encephalographers, and 2,455 individual seizures were annotated by a single expert as a pragmatic, clinically representative reference standard. Three NSDs were evaluated: a feature-based support vector machine detector (NSD1) and two deep-learning detectors (NSD2 and Persyst-15). Using an any-overlap approach, outcomes included neonate-level seizure identification, seizure-level detection, false detections per day (FD/day), and detection latency. Results: We analyzed 15,343 hours of cEEG (median 98 hours per neonate); 55 neonates (33%) had seizures. All NSDs identified ≥95% of neonates with seizures. Seizure-level detection varied: NSD2 detected 35% (IQR 17–53%), NSD1 63% (IQR 38–82%), and Persyst-15 60% (IQR 37–80%) of seizures. NSD1 generated significantly more FDs (46 FD/day, IQR 22–82) than NSD2 (3.2 IQR 1.2–9.3) and Persyst-15 (2.8 IQR 1.1–6.2; P < 0.0001). The median time to first true detection was <1 minute for NSD1 and Persyst-15, versus 26 minutes for NSD2. Conclusions: AI-based NSDs demonstrated high infant-level sensitivity but different tradeoffs between seizure-level detection and alarm burden. These findings highlight how AI tools may augment clinical EEG workflows and support earlier seizure recognition, while underscoring the need for evaluation under real-world conditions to guide safe and effective implementation.
- 11 November 2026
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
Artificial Intelligence-Based Neonatal Seizure Detection: A Pragmatic Evaluation of Clinical Performance Tradeoffs in Clinical EEG
Purpose: The aim of this study was to evaluate how three artificial intelligence (AI)-based neonatal seizure detectors (NSDs) perform in a large, clinically acquired data set and their potential to support timely seizure identification. Methods: We conducted a secondary analysis of continuous EEG (cEEG) recordings from 169 neonates born at ≥35 weeks gestation with neonatal encephalopathy. Seizure presence was determined by independent review by two or three pediatric encephalographers, and 2,455 individual seizures were annotated by a single expert as a pragmatic, clinically representative reference standard. Three NSDs were evaluated: a feature-based support vector machine detector (NSD1) and two deep-learning detectors (NSD2 and Persyst-15). Using an any-overlap approach, outcomes included neonate-level seizure identification, seizure-level detection, false detections per day (FD/day), and detection latency. Results: We analyzed 15,343 hours of cEEG (median 98 hours per neonate); 55 neonates (33%) had seizures. All NSDs identified ≥95% of neonates with seizures. Seizure-level detection varied: NSD2 detected 35% (IQR 17–53%), NSD1 63% (IQR 38–82%), and Persyst-15 60% (IQR 37–80%) of seizures. NSD1 generated significantly more FDs (46 FD/day, IQR 22–82) than NSD2 (3.2 IQR 1.2–9.3) and Persyst-15 (2.8 IQR 1.1–6.2; P < 0.0001). The median time to first true detection was <1 minute for NSD1 and Persyst-15, versus 26 minutes for NSD2. Conclusions: AI-based NSDs demonstrated high infant-level sensitivity but different tradeoffs between seizure-level detection and alarm burden. These findings highlight how AI tools may augment clinical EEG workflows and support earlier seizure recognition, while underscoring the need for evaluation under real-world conditions to guide safe and effective implementation.
- Open Access
- 29 April 2024
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 18, 1417744
Corrigendum: Building an open source classifier for the neonatal EEG background: a systematic feature-based approach from expert scoring to clinical visualization
Corrigendum: Building an open source classifier for the neonatal EEG background: a systematic feature-based approach from expert scoring to clinical visualization
- 29 April 2024
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 18, 1417744
Open AccessCorrigendum: Building an open source classifier for the neonatal EEG background: a systematic feature-based approach from expert scoring to clinical visualization
Corrigendum: Building an open source classifier for the neonatal EEG background: a systematic feature-based approach from expert scoring to clinical visualization
- Open Access
- 15 March 2024
- Published by Elsevier in Clinical Neurophysiology
- Vol. 162, 68-76
Clinical outcome prediction with an automated EEG trend, Brain State of the Newborn, after perinatal asphyxia
- 15 March 2024
- Published by Elsevier in Clinical Neurophysiology
- Vol. 162, 68-76
Open AccessClinical outcome prediction with an automated EEG trend, Brain State of the Newborn, after perinatal asphyxia
- Open Access
- 22 November 2022
- Published by Elsevier in The Lancet Digital Health
- Vol. 4 (12) , e884-e892
An automated bedside measure for monitoring neonatal cortical activity: a supervised deep learning-based electroencephalogram classifier with external cohort validation
- 22 November 2022
- Published by Elsevier in The Lancet Digital Health
- Vol. 4 (12) , e884-e892
Open AccessAn automated bedside measure for monitoring neonatal cortical activity: a supervised deep learning-based electroencephalogram classifier with external cohort validation
- Open Access
- 9 September 2022
- Published by Elsevier in Clinical Neurophysiology
- Vol. 143, 75-83
Sleep State Trend (SST), a bedside measure of neonatal sleep state fluctuations based on single EEG channels
- 9 September 2022
- Published by Elsevier in Clinical Neurophysiology
- Vol. 143, 75-83
Open AccessSleep State Trend (SST), a bedside measure of neonatal sleep state fluctuations based on single EEG channels
- Open Access
Ensemble learning using individual neonatal data for seizure detection
Sharing medical data between institutions is difficult in practice due to data protection laws and official procedures within institutions. Therefore, most existing algorithms are trained on relatively small electroencephalogram (EEG) data sets which is likely to be detrimental to prediction accuracy. In this work, we simulate a case when the data can not be shared by splitting the publicly available data set into disjoint sets representing data in individual institutions. We propose to train a (local) detector in each institution and aggregate their individual predictions into one final prediction. Four aggregation schemes are compared, namely, the majority vote, the mean, the weighted mean and the Dawid-Skene method. The method was validated on an independent data set using only a subset of EEG channels. The ensemble reaches accuracy comparable to a single detector trained on all the data when sufficient amount of data is available in each institution. The weighted mean aggregation scheme showed best performance, it was only marginally outperformed by the Dawid--Skene method when local detectors approach performance of a single detector trained on all available data.
Open AccessEnsemble learning using individual neonatal data for seizure detection
Sharing medical data between institutions is difficult in practice due to data protection laws and official procedures within institutions. Therefore, most existing algorithms are trained on relatively small electroencephalogram (EEG) data sets which is likely to be detrimental to prediction accuracy. In this work, we simulate a case when the data can not be shared by splitting the publicly available data set into disjoint sets representing data in individual institutions. We propose to train a (local) detector in each institution and aggregate their individual predictions into one final prediction. Four aggregation schemes are compared, namely, the majority vote, the mean, the weighted mean and the Dawid-Skene method. The method was validated on an independent data set using only a subset of EEG channels. The ensemble reaches accuracy comparable to a single detector trained on all the data when sufficient amount of data is available in each institution. The weighted mean aggregation scheme showed best performance, it was only marginally outperformed by the Dawid--Skene method when local detectors approach performance of a single detector trained on all available data.
- Open Access
- 31 May 2021
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 15
Building an Open Source Classifier for the Neonatal EEG Background: A Systematic Feature-Based Approach From Expert Scoring to Clinical Visualization
Neonatal brain monitoring in the neonatal intensive care units (NICU) requires a continuous review of the spontaneous cortical activity, i.e., the electroencephalograph (EEG) background activity. This needs development of bedside methods for an automated assessment of the EEG background activity. In this paper, we present development of the key components of a neonatal EEG background classifier, starting from the visual background scoring to classifier design, and finally to possible bedside visualization of the classifier results. A dataset with 13,200 5-minute EEG epochs (8–16 channels) from 27 infants with birth asphyxia was used for classifier training after scoring by two independent experts. We tested three classifier designs based on 98 computational features, and their performance was assessed with respect to scoring system, pre- and post-processing of labels and outputs, choice of channels, and visualization in monitor displays. The optimal solution achieved an overall classification accuracy of 97% with a range across subjects of 81–100%. We identified a set of 23 features that make the classifier highly robust to the choice of channels and missing data due to artefact rejection. Our results showed that an automated bedside classifier of EEG background is achievable, and we publish the full classifier algorithm to allow further clinical replication and validation studies.
- 31 May 2021
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 15
Open AccessBuilding an Open Source Classifier for the Neonatal EEG Background: A Systematic Feature-Based Approach From Expert Scoring to Clinical Visualization
Neonatal brain monitoring in the neonatal intensive care units (NICU) requires a continuous review of the spontaneous cortical activity, i.e., the electroencephalograph (EEG) background activity. This needs development of bedside methods for an automated assessment of the EEG background activity. In this paper, we present development of the key components of a neonatal EEG background classifier, starting from the visual background scoring to classifier design, and finally to possible bedside visualization of the classifier results. A dataset with 13,200 5-minute EEG epochs (8–16 channels) from 27 infants with birth asphyxia was used for classifier training after scoring by two independent experts. We tested three classifier designs based on 98 computational features, and their performance was assessed with respect to scoring system, pre- and post-processing of labels and outputs, choice of channels, and visualization in monitor displays. The optimal solution achieved an overall classification accuracy of 97% with a range across subjects of 81–100%. We identified a set of 23 features that make the classifier highly robust to the choice of channels and missing data due to artefact rejection. Our results showed that an automated bedside classifier of EEG background is achievable, and we publish the full classifier algorithm to allow further clinical replication and validation studies.