Yongyi Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yongyi Zhao has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Ashok Veeraraghavan
Rice University
6 shared publications - Jacob T. Robinson
Department of Bioengineering, Rice University, Houston, TX, USA
6 shared publications Andreas H. Hielscher
Department of Biomedical Engineering, New York University Tandon School of Engineering, New York, NY, USA
3 shared publicationsAnkit Raghuram
Rice University, Department of Electrical and Computer Engineering, Houston, Texas, United States
2 shared publications- Ankit Raghuram
Department of Electrical and Computer Engineering, Rice University, Houston, TX, USA
2 shared publications Ashok Veeraraghavan
Rice University, Department of Electrical and Computer Engineering, Houston, Texas, United States
2 shared publications
Latest Publications
- Open Access
- 1 August 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (08) , 1-12
Noninvasive monitoring of fetal tissue oxygenation level using time-domain NIRS
SignificanceFetal oxygenation level is a critical indicator of fetal health throughout pregnancy and labor. Existing clinical devices predominantly employ invasive techniques, posing risks to both the fetus and the mother.AimTo address this concern, we present a noninvasive method for precise fetal oxygenation level monitoring using time-domain near-infrared spectroscopy (TD-NIRS).ApproachOur method leverages the advantages of time-domain information for accurate separation of optical properties from two distinct layers, thereby enabling noninvasive detection of deep tissue oxygenation levels.ResultsWe validate the proposed method via Monte Carlo simulations and develop a fiber-based TD-NIRS prototype system. In a two-layer tissue phantom experiment, the system accurately estimates the deep-layer absorption coefficient. We further demonstrate the ability of our prototype system to detect changes in the tissue oxygenation index (TOI) through in vivo experiments: (1) TOI measurements of the human forearm with a tissue phantom and (2) transabdominal fetal monitoring on a pregnant ewe.ConclusionsThe results suggest a significant potential for the use of TD-NIRS to noninvasively and safely monitor the fetal oxygenation level.
- 1 August 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (08) , 1-12
Open AccessNoninvasive monitoring of fetal tissue oxygenation level using time-domain NIRS
SignificanceFetal oxygenation level is a critical indicator of fetal health throughout pregnancy and labor. Existing clinical devices predominantly employ invasive techniques, posing risks to both the fetus and the mother.AimTo address this concern, we present a noninvasive method for precise fetal oxygenation level monitoring using time-domain near-infrared spectroscopy (TD-NIRS).ApproachOur method leverages the advantages of time-domain information for accurate separation of optical properties from two distinct layers, thereby enabling noninvasive detection of deep tissue oxygenation levels.ResultsWe validate the proposed method via Monte Carlo simulations and develop a fiber-based TD-NIRS prototype system. In a two-layer tissue phantom experiment, the system accurately estimates the deep-layer absorption coefficient. We further demonstrate the ability of our prototype system to detect changes in the tissue oxygenation index (TOI) through in vivo experiments: (1) TOI measurements of the human forearm with a tissue phantom and (2) transabdominal fetal monitoring on a pregnant ewe.ConclusionsThe results suggest a significant potential for the use of TD-NIRS to noninvasively and safely monitor the fetal oxygenation level.
- 27 May 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (6) , 753-768
SCREEN: SCatteREr ENabled optical asymmetry
Optics that allow us to see clearly along one viewing direction while obscuring others’ view of us are useful in numerous settings, including privacy-preserving window screens and one-way mirrors for psychological studies. Additionally, due to the rise of cameras that are able to see outside the visible spectrum, there is a need for optics that can also provide one-way visibility at these wavelengths. This is particularly challenging for thermal (i.e., infrared) imaging because most existing methods require precise control of scene illumination, which is difficult to achieve in the infrared. To address this challenge, we demonstrate broadband, passive one-way visibility by precisely tuning the position and optical parameters of a single optical scatterer. We show the benefits of our approach in both a simulated and an experimental testbed. With experimental data, we demonstrate a 5.22× and 5.23× improvement in the degree of asymmetry for midwave infrared (MWIR) and visible (VIS) wavelengths, respectively. Ultimately, our method introduces a robust, passive one-way visibility system at midwave infrared (MWIR), which can aid in numerous privacy preservation applications.
- 27 May 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (6) , 753-768
SCREEN: SCatteREr ENabled optical asymmetry
Optics that allow us to see clearly along one viewing direction while obscuring others’ view of us are useful in numerous settings, including privacy-preserving window screens and one-way mirrors for psychological studies. Additionally, due to the rise of cameras that are able to see outside the visible spectrum, there is a need for optics that can also provide one-way visibility at these wavelengths. This is particularly challenging for thermal (i.e., infrared) imaging because most existing methods require precise control of scene illumination, which is difficult to achieve in the infrared. To address this challenge, we demonstrate broadband, passive one-way visibility by precisely tuning the position and optical parameters of a single optical scatterer. We show the benefits of our approach in both a simulated and an experimental testbed. With experimental data, we demonstrate a 5.22× and 5.23× improvement in the degree of asymmetry for midwave infrared (MWIR) and visible (VIS) wavelengths, respectively. Ultimately, our method introduces a robust, passive one-way visibility system at midwave infrared (MWIR), which can aid in numerous privacy preservation applications.
- 1 May 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (9) , 3122-3125
High spatial resolution diffuse optical tomography with directional information
Diffuse optical tomography (DOT) is a promising method for imaging through densely scattering media such as the human tissue and skull. DOT has various biomedical applications in functional brain imaging and breast cancer detection with the advantages of being portable, inexpensive, and noninvasive. However, achieving high spatial resolution remains a challenge in traditional DOT setups. In this work, we propose a multi-directional DOT (MD-DOT) approach that utilizes the directional information of detected photons to enhance spatial resolution. Using Monte Carlo-based simulations with a complete DOT reconstruction pipeline, we demonstrate that incorporating directional information significantly improves spatial resolution to the mm scale. Overall, this work shows promising improvements in DOT-related medical imaging applications where precision is critical, such as early detection of small tumors.
- 1 May 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (9) , 3122-3125
High spatial resolution diffuse optical tomography with directional information
Diffuse optical tomography (DOT) is a promising method for imaging through densely scattering media such as the human tissue and skull. DOT has various biomedical applications in functional brain imaging and breast cancer detection with the advantages of being portable, inexpensive, and noninvasive. However, achieving high spatial resolution remains a challenge in traditional DOT setups. In this work, we propose a multi-directional DOT (MD-DOT) approach that utilizes the directional information of detected photons to enhance spatial resolution. Using Monte Carlo-based simulations with a complete DOT reconstruction pipeline, we demonstrate that incorporating directional information significantly improves spatial resolution to the mm scale. Overall, this work shows promising improvements in DOT-related medical imaging applications where precision is critical, such as early detection of small tumors.
- Open Access
Angle Sensitive Pixels for Lensless Imaging on Spherical Sensors
We propose OrbCam, a lensless architecture for imaging with spherical sensors. Prior work in lensless imager techniques have focused largely on using planar sensors; for such designs, it is important to use a modulation element, e.g. amplitude or phase masks, to construct a invertible imaging system. In contrast, we show that the diversity of pixel orientations on a curved surface is sufficient to improve the conditioning of the mapping between the scene and the sensor. Hence, when imaging on a spherical sensor, all pixels can have the same angular response function such that the lensless imager is comprised of pixels that are identical to each other and differ only in their orientations. We provide the computational tools for the design of the angular response of the pixels in a spherical sensor that leads to well-conditioned and noise-robust measurements. We validate our design in both simulation and a lab prototype. The implications of our design is that the lensless imaging can be enabled easily for curved and flexible surfaces thereby opening up a new set of application domains.
Open AccessAngle Sensitive Pixels for Lensless Imaging on Spherical Sensors
We propose OrbCam, a lensless architecture for imaging with spherical sensors. Prior work in lensless imager techniques have focused largely on using planar sensors; for such designs, it is important to use a modulation element, e.g. amplitude or phase masks, to construct a invertible imaging system. In contrast, we show that the diversity of pixel orientations on a curved surface is sufficient to improve the conditioning of the mapping between the scene and the sensor. Hence, when imaging on a spherical sensor, all pixels can have the same angular response function such that the lensless imager is comprised of pixels that are identical to each other and differ only in their orientations. We provide the computational tools for the design of the angular response of the pixels in a spherical sensor that leads to well-conditioned and noise-robust measurements. We validate our design in both simulation and a lab prototype. The implications of our design is that the lensless imaging can be enabled easily for curved and flexible surfaces thereby opening up a new set of application domains.
- 8 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 9 (25730436) , 459-474
High-Speed Time-Domain Diffuse Optical Tomography With a Sensitivity Equation-Based Neural Network
Steady progress in time-domain diffuse optical tomography (TD-DOT) technology is allowing for the first time the design of low-cost, compact, and high-performance systems, thus promising more widespread clinical TD-DOT use, such as for recording brain tissue hemodynamics. TD-DOT is known to provide more accurate values of optical properties and physiological parameters compared to its frequency-domain or steady-state counterparts. However, achieving high temporal resolution is still difficult, as solving the inverse problem is computationally demanding, leading to relatively long reconstruction times. The runtime is further compromised by processes that involve ‘nontrivial’ empirical tuning of reconstruction parameters, which increases complexity and inefficiency. To address these challenges, we present a new reconstruction algorithm that combines a deep-learning approach with our previously introduced sensitivity-equation-based, non-iterative sparse optical reconstruction (SENSOR) code. The new algorithm (called SENSOR-NET) unfolds the iterations of SENSOR into a deep neural network. In this way, we achieve high-resolution sparse reconstruction using only learned parameters, thus eliminating the need to tune parameters prior to reconstruction empirically. Furthermore, once trained, the reconstruction time is not dependent on the number of sources or wavelengths used. We validate our method with numerical and experimental data and show that accurate reconstructions with 1 mm spatial resolution can be obtained in under 20 milliseconds regardless of the number of sources used in the setup. This opens the door for real-time brain monitoring and other high-speed DOT applications.
- 8 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 9 (25730436) , 459-474
High-Speed Time-Domain Diffuse Optical Tomography With a Sensitivity Equation-Based Neural Network
Steady progress in time-domain diffuse optical tomography (TD-DOT) technology is allowing for the first time the design of low-cost, compact, and high-performance systems, thus promising more widespread clinical TD-DOT use, such as for recording brain tissue hemodynamics. TD-DOT is known to provide more accurate values of optical properties and physiological parameters compared to its frequency-domain or steady-state counterparts. However, achieving high temporal resolution is still difficult, as solving the inverse problem is computationally demanding, leading to relatively long reconstruction times. The runtime is further compromised by processes that involve ‘nontrivial’ empirical tuning of reconstruction parameters, which increases complexity and inefficiency. To address these challenges, we present a new reconstruction algorithm that combines a deep-learning approach with our previously introduced sensitivity-equation-based, non-iterative sparse optical reconstruction (SENSOR) code. The new algorithm (called SENSOR-NET) unfolds the iterations of SENSOR into a deep neural network. In this way, we achieve high-resolution sparse reconstruction using only learned parameters, thus eliminating the need to tune parameters prior to reconstruction empirically. Furthermore, once trained, the reconstruction time is not dependent on the number of sources or wavelengths used. We validate our method with numerical and experimental data and show that accurate reconstructions with 1 mm spatial resolution can be obtained in under 20 milliseconds regardless of the number of sources used in the setup. This opens the door for real-time brain monitoring and other high-speed DOT applications.
- Open Access
- 1 March 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (03) , 036002-24
Unrolled-DOT: an interpretable deep network for diffuse optical tomography
Light scattering is one of the primary limitations for optical imaging in biological tissue. It leads to lower spatial resolution, contrast and signal-to-noise ratio (SNR). Many optical imaging methods attempt to mitigate the effects of scattering through ballistic imaging, filtering unscattered photons from heavily scattered photons. A number of ballistic imaging techniques have been developed, including spatial filtering (i.e., confocal microscopy), polarimetry, and time-of-flight (ToF) imaging.1 – 4 Unfortunately, the number of ballistic photons decreases exponentially with optical thickness. For example, optical imaging through the human skull requires imaging through of tissue with scattering coefficient . This corresponds to mean free paths, which indicates on average a photon will undergo 60 scattering events while propagating through a scatterer of this thickness. Therefore, only one ballistic photon would remain for every photons from the light source. As a result, most ballistic imaging methods fail to image beyond a few millimeters of tissue. The limited depth of ballistic imaging has led to great interest in diffuse optical tomography, a technique that uses ballistic and diffuse photons to image through densely scattering media.- 1 March 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (03) , 036002-24
Open AccessUnrolled-DOT: an interpretable deep network for diffuse optical tomography
Light scattering is one of the primary limitations for optical imaging in biological tissue. It leads to lower spatial resolution, contrast and signal-to-noise ratio (SNR). Many optical imaging methods attempt to mitigate the effects of scattering through ballistic imaging, filtering unscattered photons from heavily scattered photons. A number of ballistic imaging techniques have been developed, including spatial filtering (i.e., confocal microscopy), polarimetry, and time-of-flight (ToF) imaging.1 – 4 Unfortunately, the number of ballistic photons decreases exponentially with optical thickness. For example, optical imaging through the human skull requires imaging through of tissue with scattering coefficient . This corresponds to mean free paths, which indicates on average a photon will undergo 60 scattering events while propagating through a scatterer of this thickness. Therefore, only one ballistic photon would remain for every photons from the light source. As a result, most ballistic imaging methods fail to image beyond a few millimeters of tissue. The limited depth of ballistic imaging has led to great interest in diffuse optical tomography, a technique that uses ballistic and diffuse photons to image through densely scattering media. - 13 November 2022
- Published by Springer Nature
- p. 538-556
PANDORA: Polarization-Aided Neural Decomposition of Radiance
- 13 November 2022
- Published by Springer Nature
- p. 538-556
PANDORA: Polarization-Aided Neural Decomposition of Radiance
- 9 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Pattern Analysis and Machine Intelligence
- Vol. 43 (7) , 2206-2219
High Resolution, Deep Imaging Using Confocal Time-of-Flight Diffuse Optical Tomography
Light scattering by tissue severely limits how deep beneath the surface one can image, and the spatial resolution one can obtain from these images. Diffuse optical tomography (DOT) is one of the most powerful techniques for imaging deep within tissue – well beyond the conventional$\sim$ 10-15 mean scattering lengths tolerated by ballistic imaging techniques such as confocal and two-photon microscopy. Unfortunately, existing DOT systems are limited, achieving only centimeter-scale resolution. Furthermore, they suffer from slow acquisition times and slow reconstruction speeds making real-time imaging infeasible. We show that time-of-flight diffuse optical tomography (ToF-DOT) and its confocal variant (CToF-DOT), by exploiting the photon travel time information, allow us to achieve millimeter spatial resolution in the highly scattered diffusion regime ($> \!\!50$ mean free paths). In addition, we demonstrate two additional innovations: focusing on confocal measurements, and multiplexing the illumination sources allow us to significantly reduce the measurement acquisition time. Finally, we rely on a novel convolutional approximation that allows us to develop a fast reconstruction algorithm, achieving a 100× speedup in reconstruction time compared to traditional DOT reconstruction techniques. Together, we believe that these technical advances serve as the first step towards real-time, millimeter resolution, deep tissue imaging using DOT.- 9 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Pattern Analysis and Machine Intelligence
- Vol. 43 (7) , 2206-2219
High Resolution, Deep Imaging Using Confocal Time-of-Flight Diffuse Optical Tomography
Light scattering by tissue severely limits how deep beneath the surface one can image, and the spatial resolution one can obtain from these images. Diffuse optical tomography (DOT) is one of the most powerful techniques for imaging deep within tissue – well beyond the conventional$\sim$ 10-15 mean scattering lengths tolerated by ballistic imaging techniques such as confocal and two-photon microscopy. Unfortunately, existing DOT systems are limited, achieving only centimeter-scale resolution. Furthermore, they suffer from slow acquisition times and slow reconstruction speeds making real-time imaging infeasible. We show that time-of-flight diffuse optical tomography (ToF-DOT) and its confocal variant (CToF-DOT), by exploiting the photon travel time information, allow us to achieve millimeter spatial resolution in the highly scattered diffusion regime ($> \!\!50$ mean free paths). In addition, we demonstrate two additional innovations: focusing on confocal measurements, and multiplexing the illumination sources allow us to significantly reduce the measurement acquisition time. Finally, we rely on a novel convolutional approximation that allows us to develop a fast reconstruction algorithm, achieving a 100× speedup in reconstruction time compared to traditional DOT reconstruction techniques. Together, we believe that these technical advances serve as the first step towards real-time, millimeter resolution, deep tissue imaging using DOT.- Open Access
High Resolution, Deep Imaging Using Confocal Time-of-flight Diffuse Optical Tomography
Light scattering by tissue severely limits how deep beneath the surface one can image, and the spatial resolution one can obtain from these images. Diffuse optical tomography (DOT) is one of the most powerful techniques for imaging deep within tissue -- well beyond the conventional $\sim$10-15 mean scattering lengths tolerated by ballistic imaging techniques such as confocal and two-photon microscopy. Unfortunately, existing DOT systems are limited, achieving only centimeter-scale resolution. Furthermore, they suffer from slow acquisition times and slow reconstruction speeds making real-time imaging infeasible. We show that time-of-flight diffuse optical tomography (ToF-DOT) and its confocal variant (CToF-DOT), by exploiting the photon travel time information, allow us to achieve millimeter spatial resolution in the highly scattered diffusion regime ($> 50 $ mean free paths). In addition, we demonstrate two additional innovations: focusing on confocal measurements, and multiplexing the illumination sources allow us to significantly reduce the measurement acquisition time. Finally, we rely on a novel convolutional approximation that allows us to develop a fast reconstruction algorithm, achieving a 100$\times$ speedup in reconstruction time compared to traditional DOT reconstruction techniques. Together, we believe that these technical advances serve as the first step towards real-time, millimeter resolution, deep tissue imaging using DOT.Open AccessHigh Resolution, Deep Imaging Using Confocal Time-of-flight Diffuse Optical Tomography
Light scattering by tissue severely limits how deep beneath the surface one can image, and the spatial resolution one can obtain from these images. Diffuse optical tomography (DOT) is one of the most powerful techniques for imaging deep within tissue -- well beyond the conventional $\sim$10-15 mean scattering lengths tolerated by ballistic imaging techniques such as confocal and two-photon microscopy. Unfortunately, existing DOT systems are limited, achieving only centimeter-scale resolution. Furthermore, they suffer from slow acquisition times and slow reconstruction speeds making real-time imaging infeasible. We show that time-of-flight diffuse optical tomography (ToF-DOT) and its confocal variant (CToF-DOT), by exploiting the photon travel time information, allow us to achieve millimeter spatial resolution in the highly scattered diffusion regime ($> 50 $ mean free paths). In addition, we demonstrate two additional innovations: focusing on confocal measurements, and multiplexing the illumination sources allow us to significantly reduce the measurement acquisition time. Finally, we rely on a novel convolutional approximation that allows us to develop a fast reconstruction algorithm, achieving a 100$\times$ speedup in reconstruction time compared to traditional DOT reconstruction techniques. Together, we believe that these technical advances serve as the first step towards real-time, millimeter resolution, deep tissue imaging using DOT.