Jianwu Zeng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jianwu Zeng has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Zhaoxia Yang
Department of Electrical and Computer Engineering and Technology, Minnesota State University, Mankato, MN, USA
5 shared publications - Wei Qiao
Department of Electrical and Computer Engineering, University of Nebraska-Lincoln, Lincoln, NE, USA
3 shared publications Qixing Ren
Growatt New Energy Technology, Shenzhen, China
2 shared publications- Qun Zhang
Minnesota State University
2 shared publications Vincent Winstead
Department of Electrical, Computer, and Robotics Engineering, Minnesota State University, Mankato, MN, USA
2 shared publications- Xia Du
Department of Electrical Engineering, University of Arkansas, Fayetteville, AR, USA
2 shared publications
Latest Publications
- 12 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. PP (08858993) , 1-11
Locality-Preserving Graph Laplacian Manifold Learning Based Model Predictive Control for Three-Phase Inverters
This paper presents a model predictive control (MPC) strategy for three-phase inverters based on locality preserving projections (LPP). Unlike conventional machine learning (ML)–based MPC approaches that rely on predefined or high-dimensional input features, the proposed LPP-MPC automatically extracts compact, informative representations by preserving the data's intrinsic geometric structure. This dimensionality reduction enables fast linear control-law evaluation with computational complexity O(1), making the controller well-suited for real-time implementation. Experimental results demonstrate that the LPP-MPC achieves lower total harmonic distortion (THD) and reduced tracking error compared to quadratic-programming (QP) MPC under both linear and nonlinear load conditions, and the proposed controller maintains consistently lower THD throughout load transients than other methods such as two-degree-of-freedom (2DOF) MPC. Compared to existing model-free (MF) MPC and deep learning neural network (DLNN), the LPP-MPC has the lowest THD and root mean square error (RMSE) with the least computational time owing to its efficient linear structure and strong generalization capability.
- 12 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. PP (08858993) , 1-11
Locality-Preserving Graph Laplacian Manifold Learning Based Model Predictive Control for Three-Phase Inverters
This paper presents a model predictive control (MPC) strategy for three-phase inverters based on locality preserving projections (LPP). Unlike conventional machine learning (ML)–based MPC approaches that rely on predefined or high-dimensional input features, the proposed LPP-MPC automatically extracts compact, informative representations by preserving the data's intrinsic geometric structure. This dimensionality reduction enables fast linear control-law evaluation with computational complexity O(1), making the controller well-suited for real-time implementation. Experimental results demonstrate that the LPP-MPC achieves lower total harmonic distortion (THD) and reduced tracking error compared to quadratic-programming (QP) MPC under both linear and nonlinear load conditions, and the proposed controller maintains consistently lower THD throughout load transients than other methods such as two-degree-of-freedom (2DOF) MPC. Compared to existing model-free (MF) MPC and deep learning neural network (DLNN), the LPP-MPC has the lowest THD and root mean square error (RMSE) with the least computational time owing to its efficient linear structure and strong generalization capability.
- 13 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (6) , 9529-9539
A Linear Machine Learning-Based Model Predictive Control With Repetitive and PI Elements for a Three-Phase Inverter
Existing machine learning (ML) based model predictive control (MPC) methods are either inferior to the online optimized with quadratic programming (QP) MPC or have high computational complexity and cannot be implemented in the resource-limited digital signal processor (DSP). This paper solves these two issues by using linear ML methods and adding extra interpretable features. First, the intrinsic linearity of the training data generated by the QP-MPC has been theoretically proved such that the linear ML methods, e.g., linear neural network (LNN) and linear support vector regression (LSVR), can be used to capture the linearity characteristics of the training dataset. The linear operation significantly reduces the computational complexity from O(2n) to O(1) so that they can be implemented in the DSP. Second, extra features with the repetitive and proportional integral (RPI) elements are added as input to the linear ML-based MPCs. Experimental studies with QP-MPC, LNN-MPC, and LSVR-MPC with RPI elements are carried out under linear and nonlinear load conditions. The results show that linear ML-based MPCs are superior to the QP-MPC in power quality and tracking errors. Moreover, the linear ML-based MPCs outperform the QP-MPC under the parameter mismatch and two-degree-of-freedom (2DOF) controllers, demonstrating their adaptive capabilities. This article is accompanied by a video demonstrating the real-time operation.
- 13 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (6) , 9529-9539
A Linear Machine Learning-Based Model Predictive Control With Repetitive and PI Elements for a Three-Phase Inverter
Existing machine learning (ML) based model predictive control (MPC) methods are either inferior to the online optimized with quadratic programming (QP) MPC or have high computational complexity and cannot be implemented in the resource-limited digital signal processor (DSP). This paper solves these two issues by using linear ML methods and adding extra interpretable features. First, the intrinsic linearity of the training data generated by the QP-MPC has been theoretically proved such that the linear ML methods, e.g., linear neural network (LNN) and linear support vector regression (LSVR), can be used to capture the linearity characteristics of the training dataset. The linear operation significantly reduces the computational complexity from O(2n) to O(1) so that they can be implemented in the DSP. Second, extra features with the repetitive and proportional integral (RPI) elements are added as input to the linear ML-based MPCs. Experimental studies with QP-MPC, LNN-MPC, and LSVR-MPC with RPI elements are carried out under linear and nonlinear load conditions. The results show that linear ML-based MPCs are superior to the QP-MPC in power quality and tracking errors. Moreover, the linear ML-based MPCs outperform the QP-MPC under the parameter mismatch and two-degree-of-freedom (2DOF) controllers, demonstrating their adaptive capabilities. This article is accompanied by a video demonstrating the real-time operation.
- 28 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (1) , 5-13
Learning and Outperforming the Model Predictive Control With a Linear ϵ-Support Vector Machine for Power Converter
This paper presents a linear ϵ error insensitive support vector machine (ϵ-SVM) learned from the model predictive control (MPC) with very limited training samples. Unlike the existing learning-based MPC which takes the same inputs as the MPC, the ϵ-SVM learns from historical data as well. Such structure is found to have both feedforward and feedback elements that improve performance. Besides, using the ϵ error-insensitive tube also increases the noise cancellation capability. The experiment is carried out on a three-phase inverter with an L-C filter and shows that the linear ϵ-SVM-MPC not only has better performance than the artificial neural networks (ANN) MPC, but also outperforms the online MPC in both low THD values and small tracking errors regardless the load conditions. Moreover, the use of the linear kernel significantly reduces the time complexity to O (1), which is much less than O (2 n ) in either online MPC or ANN-MPC. Therefore, the linear ϵ-SVM-MPC has provided an effective way to implement the MPC and it is preferable for the DSP. This article is accompanied by a video demonstrating the real-time operation.
- 28 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (1) , 5-13
Learning and Outperforming the Model Predictive Control With a Linear ϵ-Support Vector Machine for Power Converter
This paper presents a linear ϵ error insensitive support vector machine (ϵ-SVM) learned from the model predictive control (MPC) with very limited training samples. Unlike the existing learning-based MPC which takes the same inputs as the MPC, the ϵ-SVM learns from historical data as well. Such structure is found to have both feedforward and feedback elements that improve performance. Besides, using the ϵ error-insensitive tube also increases the noise cancellation capability. The experiment is carried out on a three-phase inverter with an L-C filter and shows that the linear ϵ-SVM-MPC not only has better performance than the artificial neural networks (ANN) MPC, but also outperforms the online MPC in both low THD values and small tracking errors regardless the load conditions. Moreover, the use of the linear kernel significantly reduces the time complexity to O (1), which is much less than O (2 n ) in either online MPC or ANN-MPC. Therefore, the linear ϵ-SVM-MPC has provided an effective way to implement the MPC and it is preferable for the DSP. This article is accompanied by a video demonstrating the real-time operation.
- 24 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (7) , 6953-6963
A Carrier-Based Discontinuous PWM for an 80 Kw PV Inverter With the Reduction of the DC-Link Voltage Ripple and Common Mode Current
Discontinuous pulse width modulation (DPWM) method is broadly used in three-phase inverter to achieve high efficiency through the reduction of the switching loss. The high-power rating photovoltaic (PV) inverter with DPWM has its intrinsic issues such as large DC-link voltage ripple and high-frequency resonant current due to the large stray capacitance proportional to the power rating. To extend the application of DPWM from 10 kW to 80 kW PV inverter, a new DPWM method (DPWMn) which divides the clamping period into n intervals is proposed to achieve the three objectives simultaneously: 1) reduction of the DC-link voltage ripple; 2) suppression of the high-frequency current oscillation; 3) improve the efficiency compared to the continuous space vector PWM (SVPWM). The proposed DPWMn is validated by an 80 kW three-phase T-type PV inverter. Compared to the SVPWM, the DPWMn has reduced 30% switching loss while maintaining the similar power quality and the common mode current. Compared to the existing DPWM methods, DPWMn reduces the voltage ripple by 52% and has the minimum energy ripples. Furthermore, the carrier-based DPWMn only utilizes the measured voltage and can be easily implemented.
- 24 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (7) , 6953-6963
A Carrier-Based Discontinuous PWM for an 80 Kw PV Inverter With the Reduction of the DC-Link Voltage Ripple and Common Mode Current
Discontinuous pulse width modulation (DPWM) method is broadly used in three-phase inverter to achieve high efficiency through the reduction of the switching loss. The high-power rating photovoltaic (PV) inverter with DPWM has its intrinsic issues such as large DC-link voltage ripple and high-frequency resonant current due to the large stray capacitance proportional to the power rating. To extend the application of DPWM from 10 kW to 80 kW PV inverter, a new DPWM method (DPWMn) which divides the clamping period into n intervals is proposed to achieve the three objectives simultaneously: 1) reduction of the DC-link voltage ripple; 2) suppression of the high-frequency current oscillation; 3) improve the efficiency compared to the continuous space vector PWM (SVPWM). The proposed DPWMn is validated by an 80 kW three-phase T-type PV inverter. Compared to the SVPWM, the DPWMn has reduced 30% switching loss while maintaining the similar power quality and the common mode current. Compared to the existing DPWM methods, DPWMn reduces the voltage ripple by 52% and has the minimum energy ripples. Furthermore, the carrier-based DPWMn only utilizes the measured voltage and can be easily implemented.
- 5 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (5) , 6408-6417
A Semidiscontinuous PWM Method for Suppression of the Resonant Current in a 48 Kw Grid-Tied PV Inverter
In conventional DPWM methods, the drastic change of the modulation index during the clamping transient results in grid current oscillation, which deteriorates the power quality. This paper presents a semi-discontinuous PWM (DPWM) method for a three-level T-type grid-connected PV inverter. The semi-DPWM is achieved by injecting a continuous sinusoidal signal during the clamping transient, which reduces the grid current oscillation and reduces the total harmonic distortion of the current (THDi). First, a detailed analysis of the grid current oscillation is presented, then a semi-DPWM method is proposed to suppress the oscillation current. The experiment is carried out on a 48-kW grid-tied PV inverter to validate the effectiveness of the method. Compared with the space vector PWM (SVPWM), results show that more than 42.5% switching loss has been reduced with the semi DPWM and the efficiency is increased from 97.03% to 97.22% at the rated load. Besides, the semi DPWM method significantly suppresses the current oscillation and maintains good power quality under various operation conditions.
- 5 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (5) , 6408-6417
A Semidiscontinuous PWM Method for Suppression of the Resonant Current in a 48 Kw Grid-Tied PV Inverter
In conventional DPWM methods, the drastic change of the modulation index during the clamping transient results in grid current oscillation, which deteriorates the power quality. This paper presents a semi-discontinuous PWM (DPWM) method for a three-level T-type grid-connected PV inverter. The semi-DPWM is achieved by injecting a continuous sinusoidal signal during the clamping transient, which reduces the grid current oscillation and reduces the total harmonic distortion of the current (THDi). First, a detailed analysis of the grid current oscillation is presented, then a semi-DPWM method is proposed to suppress the oscillation current. The experiment is carried out on a 48-kW grid-tied PV inverter to validate the effectiveness of the method. Compared with the space vector PWM (SVPWM), results show that more than 42.5% switching loss has been reduced with the semi DPWM and the efficiency is increased from 97.03% to 97.22% at the rated load. Besides, the semi DPWM method significantly suppresses the current oscillation and maintains good power quality under various operation conditions.
- Open Access
- 16 December 2021
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 9
Editorial: Power Management for AC/DC Hybrid Microgrid
Editorial: Power Management for AC/DC Hybrid Microgrid
- 16 December 2021
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 9
Open AccessEditorial: Power Management for AC/DC Hybrid Microgrid
Editorial: Power Management for AC/DC Hybrid Microgrid
- Open Access
Efficiency Optimization Design of L-LLC Resonant Bidirectional DC-DC Converter
The new type of L-LLC resonant bidirectional DC-DC converter (L-LLC-BDC) has merits of high efficiency, high-power density and wide gain and power ranges, and it is suitable for energy interface between energy storage systems and DC micro grid. However, the resonances are sensitive to the parasitic parameters, which will deteriorate the efficiency. This paper investigates the intrinsic mechanism of parasitic parameters on the L-LLC-BDC operating principle and working characteristics based on the analysis of working modes and resonance tank. By taking the oscillation of parasitic parameters produced in the stage for the freewheeling stage into consideration, a parameter optimization method is proposed to reduce the resonant current oscillation while maintaining the characteristic of the natural soft switching. The experiment results not only validated the proposed parameter optimization design method, but also testified to the improvement of the efficiency through the minimization of the conduction and switching loss.
Open AccessEfficiency Optimization Design of L-LLC Resonant Bidirectional DC-DC Converter
The new type of L-LLC resonant bidirectional DC-DC converter (L-LLC-BDC) has merits of high efficiency, high-power density and wide gain and power ranges, and it is suitable for energy interface between energy storage systems and DC micro grid. However, the resonances are sensitive to the parasitic parameters, which will deteriorate the efficiency. This paper investigates the intrinsic mechanism of parasitic parameters on the L-LLC-BDC operating principle and working characteristics based on the analysis of working modes and resonance tank. By taking the oscillation of parasitic parameters produced in the stage for the freewheeling stage into consideration, a parameter optimization method is proposed to reduce the resonant current oscillation while maintaining the characteristic of the natural soft switching. The experiment results not only validated the proposed parameter optimization design method, but also testified to the improvement of the efficiency through the minimization of the conduction and switching loss.
- 20 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (11) , 12281-12291
A Multiport Bidirectional DC–DC Converter for Hybrid Renewable Energy System Integration
The bidirectional power flow in most of the existing four-port converters is achieved on the battery port located on the low voltage side, i.e., the battery is charged by the energy sources and discharged to the dc link on the high voltage side. The lack of the bidirectional power flow at the dc link prevents them from managing the power at the system level. In this article, a bidirectional four-port dc-dc converter is proposed for the integration of the hybrid renewable energy system to a dc microgrid. The proposed converter uses the least number of devices compared with the existing bidirectional multiport converters. The bidirectional battery and the dc-link ports make it a good candidate for the dc-microgrid application in which the system-level power management is desired. The working principle of the converter is first analyzed, and the power transferred by the transformer and the zero-voltage switching (ZVS) conditions are derived. Then, the converter is designed to meet the requirements of the power rating and soft switching. The proposed converter is used to interface a wind turbine, a photovoltaic panel, a battery bank, and the dc microgrid. The experiments are carried to testify the performance in both steady state and the transient. The steady-state waveforms have validated the power relationship as well as the critical ZVS conditions while maintaining relatively high efficiency. The transient testing results show that the converter can switch from one scenario to another under the different conditions. This article is accompanied by a video demonstrating the converter in the real-time operation.
- 20 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (11) , 12281-12291
A Multiport Bidirectional DC–DC Converter for Hybrid Renewable Energy System Integration
The bidirectional power flow in most of the existing four-port converters is achieved on the battery port located on the low voltage side, i.e., the battery is charged by the energy sources and discharged to the dc link on the high voltage side. The lack of the bidirectional power flow at the dc link prevents them from managing the power at the system level. In this article, a bidirectional four-port dc-dc converter is proposed for the integration of the hybrid renewable energy system to a dc microgrid. The proposed converter uses the least number of devices compared with the existing bidirectional multiport converters. The bidirectional battery and the dc-link ports make it a good candidate for the dc-microgrid application in which the system-level power management is desired. The working principle of the converter is first analyzed, and the power transferred by the transformer and the zero-voltage switching (ZVS) conditions are derived. Then, the converter is designed to meet the requirements of the power rating and soft switching. The proposed converter is used to interface a wind turbine, a photovoltaic panel, a battery bank, and the dc microgrid. The experiments are carried to testify the performance in both steady state and the transient. The steady-state waveforms have validated the power relationship as well as the critical ZVS conditions while maintaining relatively high efficiency. The transient testing results show that the converter can switch from one scenario to another under the different conditions. This article is accompanied by a video demonstrating the converter in the real-time operation.
- 11 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (4) , 3877-3887
A Composite Power Decoupling Method for a PV Inverter With Optimized Energy Buffer
A composite passive and active power decoupling method is proposed and optimized for a photovoltaic (PV) inverter. The proposed composite power decoupling (CPD) method has the following merits: 1) the dc side passive power decoupling (DC-PPD) can be automatically activated/deactivated according to the solar power to maintain more than 99% maximum power point tracking efficiency and low total harmonic current distortion (THDi); 2) the film capacitor with high reliability can be used due to the optimization of the energy buffer, e.g., a reduction of 52% and 23% in capacitance (or buffer energy) compared to DC-PPD and ac side active power decoupling, respectively; 3) control scheme developed in the d-q frame has more simple structure and requires less measurements than the existing methods. The experimental results show that the proposed CPD can dynamically control the dc-link voltage ripple under various conditions such as the abrupt change of the solar power and the load. Besides, low dc-link voltage ripple and low THDi are achieved in both steady-state and transient periods. Particularly when the solar power is less than 74%, the proposed CPD (with 261 μF) has better performance than the traditional used PPD (with 1120 μF). This article is accompanied by a video demonstrating the parameters optimization and measured waveforms.
- 11 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (4) , 3877-3887
A Composite Power Decoupling Method for a PV Inverter With Optimized Energy Buffer
A composite passive and active power decoupling method is proposed and optimized for a photovoltaic (PV) inverter. The proposed composite power decoupling (CPD) method has the following merits: 1) the dc side passive power decoupling (DC-PPD) can be automatically activated/deactivated according to the solar power to maintain more than 99% maximum power point tracking efficiency and low total harmonic current distortion (THDi); 2) the film capacitor with high reliability can be used due to the optimization of the energy buffer, e.g., a reduction of 52% and 23% in capacitance (or buffer energy) compared to DC-PPD and ac side active power decoupling, respectively; 3) control scheme developed in the d-q frame has more simple structure and requires less measurements than the existing methods. The experimental results show that the proposed CPD can dynamically control the dc-link voltage ripple under various conditions such as the abrupt change of the solar power and the load. Besides, low dc-link voltage ripple and low THDi are achieved in both steady-state and transient periods. Particularly when the solar power is less than 74%, the proposed CPD (with 261 μF) has better performance than the traditional used PPD (with 1120 μF). This article is accompanied by a video demonstrating the parameters optimization and measured waveforms.
- 11 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 81-85
Anti-Disturbance Full-Order Sliding Mode Control of PMSG-Based Wind Energy Conversion Systems
Considering the uncertainty and multi-disturbance in wind energy conversion system (WECS) and the randomness and instability of the wind power, a full-order sliding mode control (FOSMC) strategy based on an extended state observer (ESO) is proposed for the permanent magnet synchronous generator (PMSG)-based WECSs. First, based on the active disturbance rejection control (ADRC) theory, an ESO is developed to estimate the unknown states, uncertainties in the internal machine parameters and external torque disturbance. Second, a full-order sliding mode controller is designed to ensure the convergence of all system states with much reduced chattering phenomenon. Finally, the effectiveness of the proposed ESO-based FOSMC is confirmed by simulation results. The proposed FOSMC strategy will improve the efficiency and the reliability of the WECS.
- 11 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 81-85
Anti-Disturbance Full-Order Sliding Mode Control of PMSG-Based Wind Energy Conversion Systems
Considering the uncertainty and multi-disturbance in wind energy conversion system (WECS) and the randomness and instability of the wind power, a full-order sliding mode control (FOSMC) strategy based on an extended state observer (ESO) is proposed for the permanent magnet synchronous generator (PMSG)-based WECSs. First, based on the active disturbance rejection control (ADRC) theory, an ESO is developed to estimate the unknown states, uncertainties in the internal machine parameters and external torque disturbance. Second, a full-order sliding mode controller is designed to ensure the convergence of all system states with much reduced chattering phenomenon. Finally, the effectiveness of the proposed ESO-based FOSMC is confirmed by simulation results. The proposed FOSMC strategy will improve the efficiency and the reliability of the WECS.