Maman Ahmad Khan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Maman Ahmad Khan has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- Barry Hayes
School of Engineering and Architecture, University College Cork, Cork, Ireland
4 shared publications
Latest Publications
- Open Access
- 11 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 17 (2) , 2007-2017
IEEE 1588 Time Synchronization in Power Distribution System Applications: Timestamping and Accuracy Requirements
The monitoring and control of power distribution systems requires an accurate and stable time synchronization infrastructure. The major requirement for a time synchronization system is sharing a global time throughout the network. This article provides an overview of the synchronization techniques implemented in power distribution systems. The implementation of different techniques for time synchronization due to heterogeneous communication infrastructure creates various challenges in the system. Therefore, this article aims to propose a homogeneous, uniform approach for a network-based synchronization mechanism in or to implement multiple distribution system applications. For this purpose, the precision time protocol (PTP), IEEE 1588, is tested experimentally for various time criticality with an Ethernet-based communication network. The testbed uses single board computers to explore different criticality of the timestampings for IEEE 1588 (PTP) to determine how various applications need different type of timestamping depending upon the performance, cost, and accuracy requirements. These different levels of timestamping requirements for synchronization affect the performance of a range of next-generation distribution system applications. The proposed solution provides monitoring for each application using only a single time synchronization technique with an Ethernet-based network.
- 11 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 17 (2) , 2007-2017
Open AccessIEEE 1588 Time Synchronization in Power Distribution System Applications: Timestamping and Accuracy Requirements
The monitoring and control of power distribution systems requires an accurate and stable time synchronization infrastructure. The major requirement for a time synchronization system is sharing a global time throughout the network. This article provides an overview of the synchronization techniques implemented in power distribution systems. The implementation of different techniques for time synchronization due to heterogeneous communication infrastructure creates various challenges in the system. Therefore, this article aims to propose a homogeneous, uniform approach for a network-based synchronization mechanism in or to implement multiple distribution system applications. For this purpose, the precision time protocol (PTP), IEEE 1588, is tested experimentally for various time criticality with an Ethernet-based communication network. The testbed uses single board computers to explore different criticality of the timestampings for IEEE 1588 (PTP) to determine how various applications need different type of timestamping depending upon the performance, cost, and accuracy requirements. These different levels of timestamping requirements for synchronization affect the performance of a range of next-generation distribution system applications. The proposed solution provides monitoring for each application using only a single time synchronization technique with an Ethernet-based network.
- Open Access
- 14 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
A Reduced Electrically-Equivalent Model of the IEEE European Low Voltage Test Feeder
This letter presents a reduced, electrically equivalent model of the IEEE European Low Voltage Test Feeder for use in distribution network studies. The original test feeder is made up of 906 buses, of which only 55 have loads connected. This work proposes an equivalent 116 bus network which accurately represents all of the characteristics of the original test feeder, but significantly reduces the computational effort required when applied in a range of distribution system applications. The model reduction technique applied is explained in detail, and the performance of the modified network is tested under a wide range of network loading conditions. The analysis in this letter demonstrates that the modified 116 bus network produces identical results with 80% less computation time when compared to the original 906 bus network. The full data set for the modified network is provided on IEEE Dataport. Available: https://dx.doi.org/10.21227/0d2n-j565.
- 14 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessA Reduced Electrically-Equivalent Model of the IEEE European Low Voltage Test Feeder
This letter presents a reduced, electrically equivalent model of the IEEE European Low Voltage Test Feeder for use in distribution network studies. The original test feeder is made up of 906 buses, of which only 55 have loads connected. This work proposes an equivalent 116 bus network which accurately represents all of the characteristics of the original test feeder, but significantly reduces the computational effort required when applied in a range of distribution system applications. The model reduction technique applied is explained in detail, and the performance of the modified network is tested under a wide range of network loading conditions. The analysis in this letter demonstrates that the modified 116 bus network produces identical results with 80% less computation time when compared to the original 906 bus network. The full data set for the modified network is provided on IEEE Dataport. Available: https://dx.doi.org/10.21227/0d2n-j565.
- 17 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 18 (1) , 688-697
Smart Meter Based Two-Layer Distribution System State Estimation in Unbalanced MV/LV Networks
This article presents a smart meter based two-layer state estimation technique, design to enable integrated monitoring of medium-voltage (MV) and low-voltage (LV) power distribution networks. The main contributions of this work include the development of a novel topology reduction technique for LV networks in order to carry out state estimation with a reduced number of smart meter based measurements, and a linear LV state estimation technique, which reduces convergence problems in LV networks. In addition, a detailed framework for integrated MV/LV network state estimation in realistic, unbalanced three-phase networks is proposed and demonstrated using the IEEE 13 bus and IEEE 906 LV networks. The results suggest that the proposed two-layer state estimation technique is robust and provides improved distribution system state estimation accuracy compared to traditional approaches.
- 17 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 18 (1) , 688-697
Smart Meter Based Two-Layer Distribution System State Estimation in Unbalanced MV/LV Networks
This article presents a smart meter based two-layer state estimation technique, design to enable integrated monitoring of medium-voltage (MV) and low-voltage (LV) power distribution networks. The main contributions of this work include the development of a novel topology reduction technique for LV networks in order to carry out state estimation with a reduced number of smart meter based measurements, and a linear LV state estimation technique, which reduces convergence problems in LV networks. In addition, a detailed framework for integrated MV/LV network state estimation in realistic, unbalanced three-phase networks is proposed and demonstrated using the IEEE 13 bus and IEEE 906 LV networks. The results suggest that the proposed two-layer state estimation technique is robust and provides improved distribution system state estimation accuracy compared to traditional approaches.
- Open Access
- 13 July 2020
- Published by Institution of Engineering and Technology (IET) in IET Smart Grid
- Vol. 3 (5) , 705-712
PTP‐based time synchronisation of smart meter data for state estimation in power distribution networks
This paper develops a novel approach for distribution system monitoring and state estimation, where time synchronisation of smart‐meter measurements is carried out via the Precision Time Protocol (PTP). The approach is based on the concept of a Modified Smart Meter (MSM), a distribution system monitoring instrument that enables accurate time synchronisation of smart meter data. The design, application, communication technique and protocols of the MSM are described in detail. The proposed MSM device features PTP‐based time synchronisation of smart meter measurements, and the concept of unbundling is applied to collect measurements utilising the existing smart meter sensors. This is expected to reduce the overall implementation cost of an MSM‐based distribution network monitoring system compared to a system based on Phasor Measurement Units (PMUs). The problem of requiring open sky access for GPS links can potentially be solved by means of PTP synchronisation. Three‐phase state estimation simulations using the IEEE‐13 and 123 bus unbalanced test networks are employed to demonstrate the applicability of the MSM, and its performance is compared to standard PMU devices. The results indicate that the MSM may represent a workable monitoring solution for MV and LV distribution networks, with an acceptable trade‐off between cost and performance.
- 13 July 2020
- Published by Institution of Engineering and Technology (IET) in IET Smart Grid
- Vol. 3 (5) , 705-712
Open AccessPTP‐based time synchronisation of smart meter data for state estimation in power distribution networks
This paper develops a novel approach for distribution system monitoring and state estimation, where time synchronisation of smart‐meter measurements is carried out via the Precision Time Protocol (PTP). The approach is based on the concept of a Modified Smart Meter (MSM), a distribution system monitoring instrument that enables accurate time synchronisation of smart meter data. The design, application, communication technique and protocols of the MSM are described in detail. The proposed MSM device features PTP‐based time synchronisation of smart meter measurements, and the concept of unbundling is applied to collect measurements utilising the existing smart meter sensors. This is expected to reduce the overall implementation cost of an MSM‐based distribution network monitoring system compared to a system based on Phasor Measurement Units (PMUs). The problem of requiring open sky access for GPS links can potentially be solved by means of PTP synchronisation. Three‐phase state estimation simulations using the IEEE‐13 and 123 bus unbalanced test networks are employed to demonstrate the applicability of the MSM, and its performance is compared to standard PMU devices. The results indicate that the MSM may represent a workable monitoring solution for MV and LV distribution networks, with an acceptable trade‐off between cost and performance.