Diego Vergaças de Sousa Carvalho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Diego Vergaças de Sousa Carvalho has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Alexandre França Velo
Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, USA
3 shared publications Carlos Henrique de Mesquita
3 shared publicationsM.M. Hamada
3 shared publications- Pablo Antonio Salvador Vasquez
Instituto de Pesquisas Energéticas e Nucleares, IPEN–CNEN/SP
3 shared publications Anna R Petri
Nuclear and Energy Research Institute, IPEN-CNEN/SP, Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242 Cid Universitária CEP: 05508-000- São Paulo, Brasil
2 shared publicationsC.H. Mesquita
2 shared publications
Latest Publications
- Open Access
- 30 April 2021
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 9 (1A)
Development of an automated source port in IoT for application in industrial process tomography
Computed tomography technology uses an electromagnetic radiation source or particulate radiation source, to analyze / study different samples that can range from living organisms to the most diverse objects (rocks, phantoms, etc.). The use of the radioactive materials may cause harm to the operator if he is exposed to the source of radiation, so aiming at the safety of the operator, the objective of this work is to develop an Internet of Things automation system for the opening of the Industrial Process Tomography source port for industrial tomography applications. Thus, this system can drive the stepper motors through this platform can be opened at a safe distance to the operator, avoiding the operator to take radiation dose to perform this operation. For the IPT project, five source ports were made so that each was positioned diametrically opposite each array of detectors. In this project we used 192Ir sources that have activity of 18,500 MBq and that were produced in the reactor IEA-R1, from the neutron bombardment of the pellet containing stable isotope 191Ir. The main characteristics of 192Ir are: half-life of 74.2 days; radiation energy from 0.13 to 0.65 MeV. For the safety of the operator during the opening of the sources, an automated opening system with IoT that can be activated with software installed on the tomography or by a smartphone application by the MQTT protocol, which makes it possible to be monitored in real time at long distance showing the opening and closing status of each source port.
- 30 April 2021
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 9 (1A)
Open AccessDevelopment of an automated source port in IoT for application in industrial process tomography
Computed tomography technology uses an electromagnetic radiation source or particulate radiation source, to analyze / study different samples that can range from living organisms to the most diverse objects (rocks, phantoms, etc.). The use of the radioactive materials may cause harm to the operator if he is exposed to the source of radiation, so aiming at the safety of the operator, the objective of this work is to develop an Internet of Things automation system for the opening of the Industrial Process Tomography source port for industrial tomography applications. Thus, this system can drive the stepper motors through this platform can be opened at a safe distance to the operator, avoiding the operator to take radiation dose to perform this operation. For the IPT project, five source ports were made so that each was positioned diametrically opposite each array of detectors. In this project we used 192Ir sources that have activity of 18,500 MBq and that were produced in the reactor IEA-R1, from the neutron bombardment of the pellet containing stable isotope 191Ir. The main characteristics of 192Ir are: half-life of 74.2 days; radiation energy from 0.13 to 0.65 MeV. For the safety of the operator during the opening of the sources, an automated opening system with IoT that can be activated with software installed on the tomography or by a smartphone application by the MQTT protocol, which makes it possible to be monitored in real time at long distance showing the opening and closing status of each source port.
- 1 August 2018
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 62, 176-185
Liquid distribution and holdup in the random packed column
- 1 August 2018
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 62, 176-185
Liquid distribution and holdup in the random packed column
- 1 March 2017
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 53, 89-94
A portable tomography system with seventy detectors and five gamma-ray sources in fan beam geometry simulated by Monte Carlo method
- 1 March 2017
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 53, 89-94
A portable tomography system with seventy detectors and five gamma-ray sources in fan beam geometry simulated by Monte Carlo method
- 1 March 2016
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 47, 1-9
Industrial tomography using three different gamma ray
- 1 March 2016
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 47, 1-9
Industrial tomography using three different gamma ray
- 1 February 2014
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 95, 396-400
Gas–liquid distribution in a bubble column using industrial gamma-ray computed tomography
- 1 February 2014
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 95, 396-400
Gas–liquid distribution in a bubble column using industrial gamma-ray computed tomography
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Experimental and MCNP studies of Paraffin and Polyethylene in Neutron Moderation and BF3 Detector Efficiency
The Nuclear and Energy Research Institute - IPEN, offers post-graduate programs, namely: Nuclear Technology - Applications (TNA), Nuclear Technology - Materials (TNM), Nuclear Technology - Reactors (TNR). The Institute programs mission is to form expert technicians and engineers with a strong knowledge in their discipline to work in the nuclear area. The course: “Theoretical Fundaments and Practices of the Instrumentation used in Nuclear Data Acquisition” covers the use of laboratory nuclear instrumentation and the accomplishment of experiments to obtain nuclear parameters. One of these experiments is object of this work: “Experimental and MCNP Studies of Paraffin and Polyethylene Neutron Moderation and BF 3 Detector Efficiency”. Neutrons are uncharged particles and, therefore, cannot be detected by Coulomb interactions. Thus, the detector assembly used must contain some kind of material with high cross section for interaction with neutrons, called converters. A boron trifluoride (BF 3 ) detector was used in this experiment to detect neutron in real time. However, the response of this arrangement varies according to the energy range of incident neutrons. Their efficiency for thermal neutrons is above 90%, but, this result decreases, significantly, for neutrons of energy greater than 0.5 eV. The neutron moderation and, consequently, its energy variation were obtained by interposing different thicknesses of moderator material (Paraffin or Polyethylene) between the source and the detector. The detector efficiency and the optimal thickness of the moderators were determined experimentally and through computer simulations using the MCNP code. This code uses the Monte Carlo method to simulate radiation transport in matter.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Experimental and MCNP studies of Paraffin and Polyethylene in Neutron Moderation and BF3 Detector Efficiency
The Nuclear and Energy Research Institute - IPEN, offers post-graduate programs, namely: Nuclear Technology - Applications (TNA), Nuclear Technology - Materials (TNM), Nuclear Technology - Reactors (TNR). The Institute programs mission is to form expert technicians and engineers with a strong knowledge in their discipline to work in the nuclear area. The course: “Theoretical Fundaments and Practices of the Instrumentation used in Nuclear Data Acquisition” covers the use of laboratory nuclear instrumentation and the accomplishment of experiments to obtain nuclear parameters. One of these experiments is object of this work: “Experimental and MCNP Studies of Paraffin and Polyethylene Neutron Moderation and BF 3 Detector Efficiency”. Neutrons are uncharged particles and, therefore, cannot be detected by Coulomb interactions. Thus, the detector assembly used must contain some kind of material with high cross section for interaction with neutrons, called converters. A boron trifluoride (BF 3 ) detector was used in this experiment to detect neutron in real time. However, the response of this arrangement varies according to the energy range of incident neutrons. Their efficiency for thermal neutrons is above 90%, but, this result decreases, significantly, for neutrons of energy greater than 0.5 eV. The neutron moderation and, consequently, its energy variation were obtained by interposing different thicknesses of moderator material (Paraffin or Polyethylene) between the source and the detector. The detector efficiency and the optimal thickness of the moderators were determined experimentally and through computer simulations using the MCNP code. This code uses the Monte Carlo method to simulate radiation transport in matter.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Am-Be neutron irradiator used for nuclear instrumentation training
A neutron irradiator was assembled at IPEN (Nuclear and Energy Research Institute) facility to perform qualitative-quantitative analysis of materials, using thermal and fast neutrons. In order to determine the 116m In decay constant, a thermal flux obtained experimentally by Monte Carlo N-Particle Transport Code-MCNP, in a previous work, was used in the nuclear experiment. The activity calculated from the activation parameters was 13.51 ± 0.17 kBq and the activity determined experimentally was 12.51 ± 0.36 kBq. The decay constant determined by the pulse height analyzer (PHA) measures was 211.4 μ·s -1 , and that determined by fitting the data using a Multichannel Scaler (MCS) system was 200.3 ± 1.6 μ·s -1 . The half-life of 116m In found in the literature is 3256.8 s, which corresponds to a decay constant of 212.8 μ·s -1 . The present experiment does not intend to establish a new value for the decay constant: it solely aims students' practical exercises in nuclear properties of elements. This experiment is part of the nuclear experimental course.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Am-Be neutron irradiator used for nuclear instrumentation training
A neutron irradiator was assembled at IPEN (Nuclear and Energy Research Institute) facility to perform qualitative-quantitative analysis of materials, using thermal and fast neutrons. In order to determine the 116m In decay constant, a thermal flux obtained experimentally by Monte Carlo N-Particle Transport Code-MCNP, in a previous work, was used in the nuclear experiment. The activity calculated from the activation parameters was 13.51 ± 0.17 kBq and the activity determined experimentally was 12.51 ± 0.36 kBq. The decay constant determined by the pulse height analyzer (PHA) measures was 211.4 μ·s -1 , and that determined by fitting the data using a Multichannel Scaler (MCS) system was 200.3 ± 1.6 μ·s -1 . The half-life of 116m In found in the literature is 3256.8 s, which corresponds to a decay constant of 212.8 μ·s -1 . The present experiment does not intend to establish a new value for the decay constant: it solely aims students' practical exercises in nuclear properties of elements. This experiment is part of the nuclear experimental course.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 1294-1302
Multi-source third generation computed tomography for industrial multiphase flows applications
This work describes a multi-source computed tomography. It showed to be a feasible tool to study multiphase systems. In this CT scanner, two different radioactive sources, 192 Ir and 137 Cs, were placed together into a single lead collimated system. The CT is capable to determine and differentiate the attenuation coefficients of materials constituted of three phases (gas, liquid and solid), using two or more different radioisotope energies.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 1294-1302
Multi-source third generation computed tomography for industrial multiphase flows applications
This work describes a multi-source computed tomography. It showed to be a feasible tool to study multiphase systems. In this CT scanner, two different radioactive sources, 192 Ir and 137 Cs, were placed together into a single lead collimated system. The CT is capable to determine and differentiate the attenuation coefficients of materials constituted of three phases (gas, liquid and solid), using two or more different radioisotope energies.
- 1 January 2011
- Published by AIP Publishing in AIP Conference Proceedings
Internal Dosimetry of a Chylomicron-like Emulsion Labeled with [sup 14]C-CE in Humans
This paper estimates the value of the effective equivalent dose in humans due to intravenous injection of chylomicron‐like emulsion radiolabeled with A kinetic model for the chylomicron‐like emulsion in human body was proposed. The removal parameters of chylomicron‐like emulsion from the plasma were evaluated by compartimental analysis. Radiometric doses were calculated using AnaComp software and the MIRD formalism.- 1 January 2011
- Published by AIP Publishing in AIP Conference Proceedings
Internal Dosimetry of a Chylomicron-like Emulsion Labeled with [sup 14]C-CE in Humans
This paper estimates the value of the effective equivalent dose in humans due to intravenous injection of chylomicron‐like emulsion radiolabeled with A kinetic model for the chylomicron‐like emulsion in human body was proposed. The removal parameters of chylomicron‐like emulsion from the plasma were evaluated by compartimental analysis. Radiometric doses were calculated using AnaComp software and the MIRD formalism.