Seyyed Mohammad Reza Khalili
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Seyyed Mohammad Reza Khalili has a total of 130 co-authors. Here are the top co-authors by number of shared publications:
- Reza Eslami-Farsani
Faculty of Materials Science and Engineering K. N. Toosi University of Technology Tehran Iran
20 shared publications K. Malekzadeh
13 shared publicationsK. Malekzadeh Fard
Malek Ashtar University of Technology, Department of Mechanical Engineering, 4th Kilameter, Makhsous RD, Tehran, Iran
12 shared publicationsA. Shokuhfar
Department of Mechanical Engineering, K.N. Toosi University of Technology, Tehran, Iran
6 shared publicationsM. Botshekanan Dehkordi
6 shared publications- Mohammad Shariyat
Faculty of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran
6 shared publications
Latest Publications
- 27 May 2025
- Published by IOP Publishing in Engineering Research Express
- Vol. 7 (2) , 025548
Vibration energy harvesting using auxetic piezoelectric cellular solids
This study investigates vibrational energy harvesting from a cantilever plate (with clamped-free boundary conditions) using an auxetic piezoelectric patch made of PZT-5H material. An analytical model was developed by treating the auxetic piezoelectric cell as an orthotropic structure and determining its electromechanical properties through homogenization and periodic boundary conditions. A numerical model was developed in ANSYS APDL and validated against the analytical results. The influence of the geometric parameters of the auxetic piezoelectric cell on energy harvesting performance and underlying mechanisms was examined. The findings indicate that energy harvesting performance is not directly dependent on the auxetic nature (i.e., negative Poisson’s ratio); rather, when bonded to a vibrating substrate, the auxetic cell exhibits stiffener-like behavior, as revealed by displacement and stress contours. For a specific combination of cell parameters, the auxetic piezoelectric patch produced a 59% higher output voltage (29.91 V versus 18.78 V) and a 36% lower output power (0.4511 mW versus 0.7063 mW) at the peak point compared to a bulk piezoelectric patch.
- 27 May 2025
- Published by IOP Publishing in Engineering Research Express
- Vol. 7 (2) , 025548
Vibration energy harvesting using auxetic piezoelectric cellular solids
This study investigates vibrational energy harvesting from a cantilever plate (with clamped-free boundary conditions) using an auxetic piezoelectric patch made of PZT-5H material. An analytical model was developed by treating the auxetic piezoelectric cell as an orthotropic structure and determining its electromechanical properties through homogenization and periodic boundary conditions. A numerical model was developed in ANSYS APDL and validated against the analytical results. The influence of the geometric parameters of the auxetic piezoelectric cell on energy harvesting performance and underlying mechanisms was examined. The findings indicate that energy harvesting performance is not directly dependent on the auxetic nature (i.e., negative Poisson’s ratio); rather, when bonded to a vibrating substrate, the auxetic cell exhibits stiffener-like behavior, as revealed by displacement and stress contours. For a specific combination of cell parameters, the auxetic piezoelectric patch produced a 59% higher output voltage (29.91 V versus 18.78 V) and a 36% lower output power (0.4511 mW versus 0.7063 mW) at the peak point compared to a bulk piezoelectric patch.
- 27 July 2022
- Published by Wiley in Polymer Composites
- Vol. 43 (11) , 8007-8029
Lightweight biodegradable hybrid composite sandwich panel under three‐point bending loads—Experimental and numerical
In this research, the flexural behavior of lightweight biodegradable sandwich panel consisting of the outer green composite facesheets with polylactic acid (PLA) matrix and natural kenaf and cotton fibers, with five various stacking types of standard cardboard egg boxes cores under three‐point bending loads as an environmentally friendly alternative to conventional synthetic sandwich structures is investigated. The stiffness of this structure in bending is also studied using finite element simulations. The thickest specimen absorbed the most energy during flexural testing, however, the specimens containing two egg boxes inside each other were found to have a higher strength and stiffness. Using finite element method simulations to investigate the influence of composite facesheet thickness on flexural loads, it was found that the amount of the load carried by each sandwich specimen with doubled thickness was increased at least by about 50%. By changing the core's material from cardboard egg box to bamboo/PLA or kenaf‐cotton/PLA egg boxes, stiffness and strength and also the energy absorption were significantly increased. Therefore, it is possible to fabricate composite sandwich structures which are light and biodegradable for green environment and has the potential to replace many plastic products and structures that are used in food packaging and medium loads structures applications.
- 27 July 2022
- Published by Wiley in Polymer Composites
- Vol. 43 (11) , 8007-8029
Lightweight biodegradable hybrid composite sandwich panel under three‐point bending loads—Experimental and numerical
In this research, the flexural behavior of lightweight biodegradable sandwich panel consisting of the outer green composite facesheets with polylactic acid (PLA) matrix and natural kenaf and cotton fibers, with five various stacking types of standard cardboard egg boxes cores under three‐point bending loads as an environmentally friendly alternative to conventional synthetic sandwich structures is investigated. The stiffness of this structure in bending is also studied using finite element simulations. The thickest specimen absorbed the most energy during flexural testing, however, the specimens containing two egg boxes inside each other were found to have a higher strength and stiffness. Using finite element method simulations to investigate the influence of composite facesheet thickness on flexural loads, it was found that the amount of the load carried by each sandwich specimen with doubled thickness was increased at least by about 50%. By changing the core's material from cardboard egg box to bamboo/PLA or kenaf‐cotton/PLA egg boxes, stiffness and strength and also the energy absorption were significantly increased. Therefore, it is possible to fabricate composite sandwich structures which are light and biodegradable for green environment and has the potential to replace many plastic products and structures that are used in food packaging and medium loads structures applications.
- Open Access
- 23 September 2021
- Published by MDPI AG in Prosthesis
- Vol. 3 (4) , 300-313
Evaluation of Fatigue Life for Dental Implants Using FEM Analysis
The purpose of this study is to numerically analyze a 3D model of an implant under fatigue loads. A bone and a V shape implant were modeled using SolidWorks2008 software. In order to obtain an exact model, the bone was assumed as a linear orthotropic material. Mechanical loads were applied in terms of fastening torque to the abutment and mastication force applied at the top of the crown. The abutment was tightened into the implant by applying a 35 N.cm torque causing tensile stress within the abutment screw as a preload that is harmful not only for the fatigue life of the abutment, but also for the stability of the implant-abutment interface. A 700 N force at an angle of 30 degrees to the vertical direction was applied to the crown. The mechanical analysis results showed that the abutment is the critical component of the implant system in terms of fatigue failure. This is due to the fact that the tensile preloads originated from the fastening torque. The results were presented in terms of fatigue life in the abutment. Fatigue life of the abutment and implant were calculated based on the Goodman, Soderberg, Smith–Watson–Topper (SWT), and Marrow theories. According to the results of the fatigue life prediction, abutment screws may fail after about 3 × 105 cycles. The predicted results by the Goodman theory are at a very good accordance with the clinical data.
- 23 September 2021
- Published by MDPI AG in Prosthesis
- Vol. 3 (4) , 300-313
Open AccessEvaluation of Fatigue Life for Dental Implants Using FEM Analysis
The purpose of this study is to numerically analyze a 3D model of an implant under fatigue loads. A bone and a V shape implant were modeled using SolidWorks2008 software. In order to obtain an exact model, the bone was assumed as a linear orthotropic material. Mechanical loads were applied in terms of fastening torque to the abutment and mastication force applied at the top of the crown. The abutment was tightened into the implant by applying a 35 N.cm torque causing tensile stress within the abutment screw as a preload that is harmful not only for the fatigue life of the abutment, but also for the stability of the implant-abutment interface. A 700 N force at an angle of 30 degrees to the vertical direction was applied to the crown. The mechanical analysis results showed that the abutment is the critical component of the implant system in terms of fatigue failure. This is due to the fact that the tensile preloads originated from the fastening torque. The results were presented in terms of fatigue life in the abutment. Fatigue life of the abutment and implant were calculated based on the Goodman, Soderberg, Smith–Watson–Topper (SWT), and Marrow theories. According to the results of the fatigue life prediction, abutment screws may fail after about 3 × 105 cycles. The predicted results by the Goodman theory are at a very good accordance with the clinical data.
- 1 October 2019
- Published by Elsevier in Thin-Walled Structures
- Vol. 143
Numerical simulation of buckling behavior of thin walled composite shells with embedded shape memory alloy wires
- 1 October 2019
- Published by Elsevier in Thin-Walled Structures
- Vol. 143
Numerical simulation of buckling behavior of thin walled composite shells with embedded shape memory alloy wires
- 24 April 2019
- Published by SAGE Publications in Journal of Reinforced Plastics and Composites
- Vol. 38 (16) , 737-748
Study on the effective parameter of buckling behavior of cylindrical composite shells with embedded SMA wires
In this study, the buckling behavior of the cylindrical composite shells embedded with shape memory alloys is investigated experimentally. The laminated composite shells are fabricated from carbon-epoxy composite by filament-winding process with two different stacking sequences. The shape memory alloy wires with the shape memory effect and superelastic properties are placed between plies 2 and 3 of the four layers laminate with zero and 5% tensile pre-strain. Also, the effects of the number of embedded shape memory alloys wires including zero, four, and six wires are studied. Two boundary conditions CS–CS and SS–SS are used to perform the buckling test. Results show that the critical buckling load of the laminated cylindrical shells increases by using the shape memory alloy wires. It is observed that shape memory effect property of shape memory alloy wires is more effective than the other parameters. Also, from comparing the results, it is obtained that the fiber orientation and the boundary condition can change the effect of shape memory alloy wires on the buckling behavior of composite shell.
- 24 April 2019
- Published by SAGE Publications in Journal of Reinforced Plastics and Composites
- Vol. 38 (16) , 737-748
Study on the effective parameter of buckling behavior of cylindrical composite shells with embedded SMA wires
In this study, the buckling behavior of the cylindrical composite shells embedded with shape memory alloys is investigated experimentally. The laminated composite shells are fabricated from carbon-epoxy composite by filament-winding process with two different stacking sequences. The shape memory alloy wires with the shape memory effect and superelastic properties are placed between plies 2 and 3 of the four layers laminate with zero and 5% tensile pre-strain. Also, the effects of the number of embedded shape memory alloys wires including zero, four, and six wires are studied. Two boundary conditions CS–CS and SS–SS are used to perform the buckling test. Results show that the critical buckling load of the laminated cylindrical shells increases by using the shape memory alloy wires. It is observed that shape memory effect property of shape memory alloy wires is more effective than the other parameters. Also, from comparing the results, it is obtained that the fiber orientation and the boundary condition can change the effect of shape memory alloy wires on the buckling behavior of composite shell.
- 3 April 2019
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 28 (7) , 753-762
Experimental investigation on flexural properties of self-healing composites reinforced by shape memory strip
In this article, the flexural properties of self-healing smart composites reinforced by shape memory alloy strips are investigated experimentally using mechanical flexural tests. 5 groups of specimens consist of specimen without shape memory alloy (SMA) strip, specimen with one SMA strip without pre-strain, specimen with one SMA strip and 4% pre-strain, specimen with three SMA strips without pre-strain and, specimen with three SMA strips and 4% pre-strain. Short hollow glass fibers (SHGF) are embedded in all the mentioned specimens. The 25 wt. % of SHGF containing the resin and hardener were randomly distributed in the epoxy resin and the fibers/epoxy specimens were fabricated using hand layup technique. In order to determine the healing efficiency of the smart composites, the specimens were damaged initially and then subjected to flexural tests after a certain period of healing time. The influence of some effective parameters including healing time and the presence of SMA strip(s) on the healing efficiency of the smart composite was investigated. The healing efficiencies of 43.18% and 71.5% were achieved after three and seven days, respectively, for the specimens with embedded three SMA strips.
- 3 April 2019
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 28 (7) , 753-762
Experimental investigation on flexural properties of self-healing composites reinforced by shape memory strip
In this article, the flexural properties of self-healing smart composites reinforced by shape memory alloy strips are investigated experimentally using mechanical flexural tests. 5 groups of specimens consist of specimen without shape memory alloy (SMA) strip, specimen with one SMA strip without pre-strain, specimen with one SMA strip and 4% pre-strain, specimen with three SMA strips without pre-strain and, specimen with three SMA strips and 4% pre-strain. Short hollow glass fibers (SHGF) are embedded in all the mentioned specimens. The 25 wt. % of SHGF containing the resin and hardener were randomly distributed in the epoxy resin and the fibers/epoxy specimens were fabricated using hand layup technique. In order to determine the healing efficiency of the smart composites, the specimens were damaged initially and then subjected to flexural tests after a certain period of healing time. The influence of some effective parameters including healing time and the presence of SMA strip(s) on the healing efficiency of the smart composite was investigated. The healing efficiencies of 43.18% and 71.5% were achieved after three and seven days, respectively, for the specimens with embedded three SMA strips.
- 1 February 2019
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 28 (4) , 384-390
Tensile and creep behavior of microvascular based self-healing composites: Experimental study
A 3D microvascular network which was generated by 3D printing method was within the composite specimens. Healing efficiency of the composites was investigated using mechanical tensile and creep tests. The experimental results revealed that despite mechanical properties degradation in the specimens due to the presence of the embedded network, significant healing efficiency can be obtained at both room and elevated temperatures by the presented healing method. The maximum healing efficiency of 89% was obtained in tensile strength for the specimens, which were healed for 7 days. Moreover, creep behavior of the self-healing specimens showed promising results and the healing efficiency was 83% in creep rupture time of the composites at 90 °C.
- 1 February 2019
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 28 (4) , 384-390
Tensile and creep behavior of microvascular based self-healing composites: Experimental study
A 3D microvascular network which was generated by 3D printing method was within the composite specimens. Healing efficiency of the composites was investigated using mechanical tensile and creep tests. The experimental results revealed that despite mechanical properties degradation in the specimens due to the presence of the embedded network, significant healing efficiency can be obtained at both room and elevated temperatures by the presented healing method. The maximum healing efficiency of 89% was obtained in tensile strength for the specimens, which were healed for 7 days. Moreover, creep behavior of the self-healing specimens showed promising results and the healing efficiency was 83% in creep rupture time of the composites at 90 °C.
- 9 November 2018
- Published by Wiley in Polymer Composites
- Vol. 40 (5) , 1883-1889
Experimental investigation on the smart self‐healing composites based on the short hollow glass fibers and shape memory alloy strips
In the present study, self‐healing composites based on randomly oriented short hollow glass fibers and shape memory alloy (SMA) strips are investigated. Charpy impact tests were conducted to determine the healing efficiency of the specimens. The obtained results showed that an efficient healing process occurs after 7 days from the initial damage. According to the results, the presence of embedded SMA strips caused enhancement in the healing efficiency of the composites due to induced recovery force in the SMA, which leads to crack closure in the specimens. The healing efficiency of composites were calculated to be 36%, 49%, 55%, and 34% for the specimens without embedded SMA strips, and with 0%, 2%, and 4% pre‐strain SMA strips, respectively. According to the results, the healing efficiency of the specimens is affected significantly by the interfacial shear strength between the SMA strips and the glass fibers/epoxy composites. In this regards, the results showed that using 2% pre‐strained strip in the composites resulted in the highest healing efficiency. POLYM. COMPOS., 40:1883–1889, 2019. © 2018 Society of Plastics Engineers
- 9 November 2018
- Published by Wiley in Polymer Composites
- Vol. 40 (5) , 1883-1889
Experimental investigation on the smart self‐healing composites based on the short hollow glass fibers and shape memory alloy strips
In the present study, self‐healing composites based on randomly oriented short hollow glass fibers and shape memory alloy (SMA) strips are investigated. Charpy impact tests were conducted to determine the healing efficiency of the specimens. The obtained results showed that an efficient healing process occurs after 7 days from the initial damage. According to the results, the presence of embedded SMA strips caused enhancement in the healing efficiency of the composites due to induced recovery force in the SMA, which leads to crack closure in the specimens. The healing efficiency of composites were calculated to be 36%, 49%, 55%, and 34% for the specimens without embedded SMA strips, and with 0%, 2%, and 4% pre‐strain SMA strips, respectively. According to the results, the healing efficiency of the specimens is affected significantly by the interfacial shear strength between the SMA strips and the glass fibers/epoxy composites. In this regards, the results showed that using 2% pre‐strained strip in the composites resulted in the highest healing efficiency. POLYM. COMPOS., 40:1883–1889, 2019. © 2018 Society of Plastics Engineers
- 8 October 2018
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 29 (20) , 3972-3982
Optimal design of a bio-inspired self-healing metal matrix composite reinforced with NiTi shape memory alloy strips
Utilizing smart materials such as shape memory alloys as reinforcement in metal matrix composites is a novel method to bio-mimic self-healing. This study aims to investigate the influence of design factors of a self-healing metal matrix composite by employing the Taguchi method for designing of the experimental procedure. Three design factors, each in three levels, were studied simultaneously according to L-9 standard Taguchi orthogonal array to determine the optimal level of each factor in mechanical properties enhancement with a reduced number of experiments. Composite specimens were fabricated from Sn-13 wt.% Bi alloy as matrix and nickel–titanium shape memory alloy strips as reinforcement with gravity casting process. Matrix alloy was melted and casted in a preheated metallic mold in which SMA strips were installed in various quantities (one, two, or three strips) and different pre-strains (0%, 2%, or 6%). After fabrication of the specimens, a tensile test was conducted until fracture to specify mechanical properties. Then, specimens were placed in a furnace in three different temperatures (170°C, 180°C, and 190°C) to activate the shape memory effect of strips and achieve crack closure and healing. Specimens were tensile tested again after healing to calculate the amount of healed properties and healing efficiency. Results show that using three strips with 6% of pre-strain and applying 190°C healing temperature can maximize the ultimate tensile strength efficiency. Also, the existence of one strip, 0% pre-strain, and 190°C healing temperature creates the best circumstances for healing ductility.
- 8 October 2018
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 29 (20) , 3972-3982
Optimal design of a bio-inspired self-healing metal matrix composite reinforced with NiTi shape memory alloy strips
Utilizing smart materials such as shape memory alloys as reinforcement in metal matrix composites is a novel method to bio-mimic self-healing. This study aims to investigate the influence of design factors of a self-healing metal matrix composite by employing the Taguchi method for designing of the experimental procedure. Three design factors, each in three levels, were studied simultaneously according to L-9 standard Taguchi orthogonal array to determine the optimal level of each factor in mechanical properties enhancement with a reduced number of experiments. Composite specimens were fabricated from Sn-13 wt.% Bi alloy as matrix and nickel–titanium shape memory alloy strips as reinforcement with gravity casting process. Matrix alloy was melted and casted in a preheated metallic mold in which SMA strips were installed in various quantities (one, two, or three strips) and different pre-strains (0%, 2%, or 6%). After fabrication of the specimens, a tensile test was conducted until fracture to specify mechanical properties. Then, specimens were placed in a furnace in three different temperatures (170°C, 180°C, and 190°C) to activate the shape memory effect of strips and achieve crack closure and healing. Specimens were tensile tested again after healing to calculate the amount of healed properties and healing efficiency. Results show that using three strips with 6% of pre-strain and applying 190°C healing temperature can maximize the ultimate tensile strength efficiency. Also, the existence of one strip, 0% pre-strain, and 190°C healing temperature creates the best circumstances for healing ductility.