MDMartina Descovich

Martina Descovich

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Martina Descovich has a total of 258 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Deep match: A zero-shot framework for improved fiducial-free respiratory motion tracking

    by Di Xu, Martina Descovich, Hengjie Liu, Yi Lao, Alexander R. Gottschalk, Ke Sheng


  • Physics of Stereotactic Radiosurgery and Stereotactic Body Radiotherapy

    by Angélica Pérez-Andújar, Martina Descovich, Cynthia Chuang

  • Top Cited Papers

    DoseNet: a volumetric dose prediction algorithm using 3D fully-convolutional neural networks

    by Vasant P Kearney, Jason W Chan, Samuel Haaf, Martina Descovich, Timothy D Solberg

    The goal of this study is to demonstrate the feasibility of a novel fully-convolutional volumetric dose prediction neural network (DoseNet) and test its performance on a cohort of prostate stereotactic body radiotherapy (SBRT) patients. DoseNet is suggested as a superior alternative to U-Net and fully connected distance map-based neural networks for non-coplanar SBRT prostate dose prediction. DoseNet utilizes 3D convolutional downsampling with corresponding 3D deconvolutional upsampling to preserve memory while simultaneously increasing the receptive field of the network. DoseNet was implemented on 2 Nvidia 1080 Ti graphics processing units and utilizes a 3 phase learning protocol to help achieve convergence and improve generalization. DoseNet was trained, validated, and tested with 151 patients following Kaggle completion rules. The dosimetric quality of DoseNet was evaluated by comparing the predicted dose distribution with the clinically approved delivered dose distribution in terms of conformity index, heterogeneity index, and various clinically relevant dosimetric parameters. The results indicate that the DoseNet algorithm is a superior alternative to U-Net and fully connected methods for prostate SBRT patients. DoseNet required ~50.1 h to train, and ~0.83 s to make a prediction on a 128 × 128 × 64 voxel image. In conclusion, DoseNet is capable of making accurate volumetric dose predictions for non-coplanar SBRT prostate patients, while simultaneously preserving computational efficiency.


  • SBRT for High-Risk Prostate Cancer

    by Alejandro González-Motta, Mekhail Anwar, Alexander Gottschalk, Martina Descovich, Mack Roach

  • A continuous arc delivery optimization algorithm for CyberKnife m6

    by Vasant Kearney, Martina Descovich, Atchar Sudhyadhom, Joey P. Cheung, Christopher McGuinness, Timothy D. Solberg

    Purpose This study aims to reduce the delivery time of CyberKnife m6 treatments by allowing for non‐coplanar continuous arc delivery. To achieve this, a novel non‐coplanar continuous arc delivery optimization algorithm was developed for the CyberKnife m6 treatment system (CyberArc‐m6). Methods and Materials CyberArc‐m6 uses a 5 step overarching strategy, in which an initial set of beam geometries is determined, the robotic delivery path is calculated, direct aperture optimization is conducted, intermediate MLC configurations are extracted, and the final beam weights are computed for the continuous arc radiation source model. This algorithm was implemented on 5 prostate and 3 brain patients, previously planned using a conventional step‐and‐shoot CyberKnife m6 delivery technique. The dosimetric quality of the CyberArc‐m6 plans was assessed using locally confined mutual information (LCMI), conformity index (CI), heterogeneity index (HI), and a variety of common clinical dosimetric objectives. Results Using conservative optimization tuning parameters, CyberArc‐m6 plans were able to achieve an average CI difference of 0.036 ± 0.025, an average HI difference of 0.046 ± 0.038, and an average LCMI of 0.920 ± 0.030 compared with the original CyberKnife m6 plans. Including a 5 second per minute image alignment time and a 5 minute set up time, conservative CyberArc‐m6 plans achieved an average treatment delivery speed up of 1.545x ± 0.305x compared with step‐and‐shoot plans. Conclusions The CyberArc‐m6 algorithm was able to achieve dosimetrically similar plans compared to their step‐and‐shoot CyberKnife m6 counterparts, while simultaneously reducing treatment delivery times.


  • Open Access

    Influence of respiratory motion management technique on radiation pneumonitis risk with robotic stereotactic body radiation therapy

    by Christopher H. Chapman, Christopher McGuinness, Alexander R. Gottschalk, Sue S. Yom, Adam A. Garsa, Mekhail Anwar, Steve E. Braunstein, Atchar Sudhyadhom, Paul Keall, Martina Descovich

    Purpose/Objectives: For lung stereotactic body radiation therapy (SBRT), real‐time tumor tracking (RTT) allows for less radiation to normal lung compared to the internal target volume (ITV) method of respiratory motion management. To quantify the advantage of RTT, we examined the difference in radiation pneumonitis risk between these two techniques using a normal tissue complication probability (NTCP) model.Materials/Method: 20 lung SBRT treatment plans using RTT were replanned with the ITV method using respiratory motion information from a 4D‐CT image acquired at the original simulation. Risk of symptomatic radiation pneumonitis was calculated for both plans using a previously derived NTCP model. Features available before treatment planning that identified significant increase in NTCP with ITV versus RTT plans were identified.Results: Prescription dose to the planning target volume (PTV) ranged from 22 to 60 Gy in 1–5 fractions. The median tumor diameter was 3.5 cm (range 2.1–5.5 cm) with a median volume of 14.5 mL (range 3.6–59.9 mL). The median increase in PTV volume from RTT to ITV plans was 17.1 mL (range 3.5–72.4 mL), and the median increase in PTV/lung volume ratio was 0.46% (range 0.13–1.98%). Mean lung dose and percentage dose–volumes were significantly higher in ITV plans at all levels tested. The median NTCP was 5.1% for RTT plans and 8.9% for ITV plans, with a median difference of 1.9% (range 0.4–25.5%, pairwise P < 0.001). Increases in NTCP between plans were best predicted by increases in PTV volume and PTV/lung volume ratio.Conclusions: The use of RTT decreased the risk of radiation pneumonitis in all plans. However, for most patients the risk reduction was minimal. Differences in plan PTV volume and PTV/lung volume ratio may identify patients who would benefit from RTT technique before completing treatment planning.


  • Stereotactic Body Radiotherapy (SBRT) in the Management of Clinically Localized Prostate Cancer: Where are We Now?

    by Mack Roach, Nora Fahim, Michael Wahl, Soha A. Ahmed, Martina Descovich

    BACKGROUND: Stereotactic body radiotherapy (SBRT) is a recent addition to the armamentarium for treating clinically localized prostate cancer. SBRT is a special form of image-guided radiotherapy (IGRT) that involves the delivery of a small number of very high-dose fractions (e.g. 35 to 40 Gy, in 4 to 5 fractions). The slow-growing nature of prostate adenocarcinoma is thought to be associated to a low α[alpha]/β[beta] ratio of ~1.5, that is believed to confer a preferential sensitivity to ultra-hypofractionation. Literature documenting excellent long-term outcomes and relatively low toxicity with high dose-rate (HDR) brachytherapy (using similar dose-fractionation) provided a clinical rationale for SBRT. METHODS: A review was performed of available literature focusing on the current status of SBRT for clinically localized prostate cancer, including trends, evidence of late toxicity and unresolved issues. RESULTS: The adoption of SBRT for prostate cancer has been rapid, increasing from <1% in 2004 (in all patient groups), to 8.8% by 2012. Cost and convenience have contributed to this trend, despite the risk that the toxicity may be slightly higher. RTOG 0938 demonstrated the clinical tolerance and feasibility in a multi-institutional setting and is expected to form the basis for a definitive phase III trial comparing SBRT to a more conventional fractionation scheme. Whether the use of rectal spacers or modified dose constraints will improve the risk benefit ratio remains to be elucidated. More work is also needed to assess the role of SBRT as a boost after conventional radiation, in the setting of "salvage" therapy and as palliation for urinary tract obstruction due to prostate cancer. CONCLUSION: There appears to be a substantial and growing interest SBRT for clinically localized prostate but much more work is needed to define its role relative to others forms of radiation including conventional external beam radiation and brachytherapy.


  • (P086) Success of Stereotactic Body Radiation Therapy in Central Versus Peripheral Retreatment of Non-Small Cell Lung Cancer

    by Jason Chan, Julian Johnson, Ann Lazar, Steve Braunstein, Martina Descovich, Alexander Gottschalk, Adam Garsa, Sue Yom

  • Open Access

    Respiration-Induced Intraorgan Deformation of the Liver: Implications for Treatment Planning in Patients Treated With Fiducial Tracking

    by Anna K. Paulsson, Sue S. Yom, Mekhail Anwar, Dilini Pinnaduwage, Atchar Sudhyadhom, Alexander R. Gottschalk, Albert J. Chang, Martina Descovich

    Stereotactic body radiation therapy is a well-tolerated modality for the treatment of primary and metastatic liver lesions, and fiducials are often used as surrogates for tumor tracking during treatment. We evaluated respiratory-induced liver deformation by measuring the rigidity of the fiducial configuration during the breathing cycle. Seventeen patients, with 18 distinct treatment courses, were treated with stereotactic body radiosurgery using multiple fiducials. Liver deformation was empirically quantified by measuring the intrafiducial distances at different phases of respiration. Data points were collected at the 0%, 50%, and 100% inspiration points, and the distance between each pair of fiducials was measured at the 3 phases. The rigid body error was calculated as the maximum difference in the intrafiducial distances. Liver disease was calculated with Child-Pugh score using laboratory values within 3 months of initiation of treatment. A peripheral fiducial was defined as within 1.5 cm of the liver edge, and all other fiducials were classified as central. For 5 patients with only peripheral fiducials, the fiducial configuration had more deformation (average maximum rigid body error 7.11 mm, range: 1.89-11.35 mm) when compared to patients with both central and peripheral and central fiducials only (average maximum rigid body error 3.36 mm, range: 0.5-9.09 mm, P = .037). The largest rigid body errors (11.3 and 10.6 mm) were in 2 patients with Child-Pugh class A liver disease and multiple peripheral fiducials. The liver experiences internal deformation, and the fiducial configuration should not be assumed to act as a static structure. We observed greater deformation at the periphery than at the center of the liver. In our small data set, we were not able to identify cirrhosis, which is associated with greater rigidity of the liver, as predictive for deformation. Treatment planning based only on fiducial localization must take potential intraorgan deformation into account.


  • Open Access

    Interfraction Anatomical Variability Can Lead to Significantly Increased Rectal Dose for Patients Undergoing Stereotactic Body Radiotherapy for Prostate Cancer

    by Michael Wahl, Martina Descovich, Erin Shugard, Dilini Pinnaduwage, Atchar Sudhyadhom, Albert Chang, Mack Roach, Alexander Gottschalk, Josephine Chen

    Stereotactic body radiotherapy for prostate cancer is rapidly growing in popularity. Stereotactic body radiotherapy plans mimic those of high-dose rate brachytherapy, with tight margins and inhomogeneous dose distributions. The impact of interfraction anatomical changes on the dose received by organs at risk under these conditions has not been well documented. To estimate anatomical variation during stereotactic body radiotherapy, 10 patients were identified who received a prostate boost using robotic stereotactic body radiotherapy after completing 25 fractions of pelvic radiotherapy with daily megavoltage computed tomography. Rectal and bladder volumes were delineated on each megavoltage computed tomography, and the stereotactic body radiotherapy boost plan was registered to each megavoltage computed tomography image using a point-based rigid registration with 3 fiducial markers placed in the prostate. The volume of rectum and bladder receiving 75% of the prescription dose (V75%) was measured for each megavoltage computed tomography. The rectal V75% from the daily megavoltage computed tomographies was significantly greater than the planned V75% (median increase of 0.93 cm3, P < .001), whereas the bladder V75% on megavoltage computed tomography was not significantly changed (median decrease of −0.12 cm3, P = .57). Although daily prostate rotation was significantly correlated with bladder V75% (Spearman ρ = .21, P = .023), there was no association between rotation and rectal V75% or between prostate deformation and either rectal or bladder V75%. Planning organ-at-risk volume-based replanning techniques using either a 6-mm isotropic expansion of the plan rectal contour or a 1-cm expansion from the planning target volume in the superior and posterior directions demonstrated significantly improved rectal V75% on daily megavoltage computed tomographies compared to the original stereotactic body radiotherapy plan, without compromising plan quality. Thus, despite tight margins and full translational and rotational corrections provided by robotic stereotactic body radiotherapy, we find that interfraction anatomical variations can lead to a substantial increase in delivered rectal doses during prostate stereotactic body radiotherapy. A planning organ-at-risk volume-based approach to treatment planning may help mitigate the impact of daily organ motion and reduce the risk of rectal toxicity.