DGDo-Heon Gu

Do-Heon Gu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Do-Heon Gu has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Use of photocaged molecular oxygen for time-resolved serial X-ray crystallography

    by Sofia Jaho, Arturo Landeros de la Isla, Danny Axford, Sinan Battah, James Beilsten-Edmands, Do-Heon Gu, Sam Horrell, Gabriel Karras, Marina Lučić, Aidan E. Meekings, et al.

    Photocages offer an attractive means of synchronously triggering enzyme-substrate driven reactions in biological systems in crystallo expanding the reach of light-driven catalysis. We describe the application of photocaged molecular oxygen to trigger molecular oxygen binding in crystals of myoglobin under anaerobic conditions and follow structural changes using both serial synchrotron and serial femtosecond X-ray crystallography. This is enabled through use of fixed targets under anaerobic conditions, utilising thin polymeric films with low molecular oxygen permeability and validated by serially collecting deoxy myoglobin structures and complementary in crystallo UV-Vis spectroscopy. Release of molecular oxygen from the photocage and subsequent binding of the gaseous ligand is structurally visualised in oxygen-bound structures of myoglobin at 5 and 10 ms and various laser parameters. We present a robust workflow for enabling anaerobic room-temperature data collection of oxygen-sensitive samples on fixed targets and report the successful photo-release of caged molecular oxygen for time-resolved serial crystallography.

  • Open Access

    Drop-on-fixed-target reaction initiation approach for serial and time-resolved crystallography

    by Jos J. A. G. Kamps, Philip Hinchliffe, Johan Glerup, Emily I. Freeman, Pauline A. Lang, Catherine L. Tooke, Michael Beer, Laura Parkinson, Do-Heon Gu, Sehan Park, et al.

    We describe the design and implementation of a drop-on-fixed-target method for time-resolved serial crystallography at both synchrotron and XFEL facilities. A piezoelectric droplet dispensing pipette is employed for addition of picolitre volume aqueous droplets (∼40–90 pl; ∼40–55 µm diameter sphere), containing (co-)substrate(s) or ligand(s), onto enzyme microcrystals previously loaded into the trapezoidal wells of an etched crystalline silicon fixed-target chip containing 25 600 wells in a high-density, square grid with 125 µm centre-to-centre well spacing. These features demand exquisite accuracy and thereby constrain motion controls to enable robust time-resolved crystallographic studies. The system was tested with three enzyme systems, comprising lysozyme and two β-lactamases, CTX-M-15 and AmpC EC . Mitigation strategies for cross-well contamination, including the implementation of interleaved controls, are described; the overall performance of the system at synchrotron and X-ray free-electron laser facilities was evaluated. This drop-on-fixed-target method is a reliable framework for time-resolved crystallography and will improve the consistency of measurements across facilities.


  • Open Access

    Increasing X-ray energy improves data quality in serial crystallography

    by Do-Heon Gu, Danny Axford, James Beilsten-Edmands, Sofia Jaho, Robin L. Owen

    Serial synchrotron crystallography (SSX) enables structure determination from microcrystals under near-physiological, room-temperature conditions but is limited in part due to the inevitable onset of radiation damage. The ability to reduce the absorbed dose while retaining, or even improving, data quality is an attractive means of mitigating this limitation. Advances in detector technology have made the use of high-energy X-rays a routine approach in MX, improving diffraction efficiency and enhancing overall data quality. Here, we systematically evaluate low-dose SSX data collected at five different X-ray energies from 12.4 to 25 keV using a CdTe Eiger2 detector while maintaining a constant dose. Higher photon energies increased the mean diffracted intensity and signal-to-noise ratio per unit dose, and facilitated higher-resolution structure determination, even with limited crystal numbers. These findings highlight the advantages of high-energy X-rays and provide practical guidance for optimizing SSX experiments in probing protein dynamics.


  • Open Access

    Time-resolved ligand dynamics revealed in a β-lactamase using room-temperature serial crystallography

    by Philip Hinchliffe, Catherine L Tooke, Michael Beer, Pierre Aller, Jos Jag Kamps, Laura Parkinson, Tiankun Zhou, Nicholas Devenish, Do-Heon Gu, Anastasya Shilova, et al.

    β-Lactamases catalyze β-lactam antibiotic hydrolysis and are important contributors to bacterial antimicrobial resistance; β-lactamase inhibitors are widely used to overcome β-lactamase-mediated antibiotic resistance. Nucleophilic serine β-lactamases (SBLs) react with their substrates and clinically available inhibitors via a covalent reaction to give complexes which can undergo further reaction. Using room temperature drop on fixed target serial crystallography, where ligands are rapidly mixed with microcrystals, and classical single-crystal crystallography at cryogenic temperatures, we investigate the reversible covalent reaction of the SBL CTX-M-15 with the diazobicyclooctane inhibitor avibactam. We observe avibactam covalently reacted (ring-opened) with the nucleophilic Ser70, at timepoints from 80 ms to minutes (room temperature) and hours (100 K). These crystallographic data reveal time-dependent movement of the avibactam carbamoyl complex, from 1.3 s onwards, that has implications for the 5-exo-trig recyclization mechanism that determines inhibitor reformation. Combined with molecular dynamics simulations and quantum mechanics calculations at the density functional theory level, the results show that in the first seconds of the reaction the avibactam N-sulfate nitrogen is poorly positioned for recyclization. This subsequently equilibrates after 10 s to a stable endpoint that is in a conformation potentially primed to initiate recyclization through attack of the N-sulfate nitrogen on the carbamoyl carbon. These results further demonstrate the capacity of room-temperature serial crystallography to capture time-resolved changes in ligand conformation at an enzyme active site, complementing discrete classical cryo-crystallography. These data inform on ligand dynamics and the stereoelectronics of diazobicyclooctane inhibition, aiding drug discovery efforts to develop inhibitors of nucleophilic enzymes.

  • Open Access

    Drop on fixed target reaction initiation approach for serial and time resolved crystallography

    by Jos J. A. G. Kamps, Philip Hinchliffe, Johan Glerup, Emily I. Freeman, Pauline A. Lang, Catherine L Tooke, Michael Beer, Laura Parkinson, Do-Heon Gu, Sehan Park, et al.

    We describe the design and implementation of a drop on fixed target method for time-resolved serial crystallography at both synchrotron and XFEL facilities. A piezoelectric droplet dispensing pipette is employed for addition of picolitre volume (40 - 90 pL) aqueous droplets, containing (co-)substrate(s) or ligand(s), onto enzyme microcrystals immobilised on a solid support. The system was tested with various enzyme systems, including lysozyme and two beta-lactamases, CTX-M-15 and AmpC. Mitigation strategies for cross-well contamination, including the implementation of interleaved controls, are described; the overall performance of the system at synchrotron and X-ray free electron laser facilities was evaluated. This drop on fixed target method is a reliable framework for time-resolved crystallography and will improve the consistency of measurements across facilities.

  • Open Access

    Novel fixed-target serial crystallography flip-holder for macromolecular crystallography beamlines at synchrotron radiation sources

    by Do-Heon Gu, Dong Tak Jeong, Cheolsoo Eo, Pil-Won Seo, Jeong-Sun Kim, Suk-Youl Park

    Synchrotron serial crystallography (SSX) is an emerging method for determining crystal structure at room temperature using synchrotron radiation facilities. Despite the various approaches available, reducing sample consumption, removing mother liquid from crystal solution, soaking small molecules for protein–ligand complex structure and prevention of sample dehydration are still challenging problems to be overcome in SSX. Therefore, we have developed a new flip-type fixed-target SSX sample holder for conventional protein crystallography beamlines based on nylon mesh and kapton film. The potential of the flip-holder was evaluated in an SSX experiment with lysozyme crystals at room temperature. About 19600 diffraction images were collected during 40 minutes using a repetition rate of 10 Hz at the 11C beamline of the Pohang Accelerator Laboratory, and the crystal structure of lysozyme was determined at 1.89 Å resolution. This straightforward flip-holder can be used in synchrotron beamlines for routine crystallography.


  • Open Access

    BL-11C Micro-MX: a high-flux microfocus macromolecular-crystallography beamline for micrometre-sized protein crystals at Pohang Light Source II

    by Do-Heon Gu, Cheolsoo Eo, Seung-A Hwangbo, Sung-Chul Ha, Jin Hong Kim, Hyoyun Kim, Chae-Soon Lee, In Deuk Seo, Young Duck Yun, Woulwoo Lee, et al.

    BL-11C, a new protein crystallography beamline, is an in-vacuum undulator-based microfocus beamline used for macromolecular crystallography at the Pohang Accelerator Laboratory and it was made available to users in June 2017. The beamline is energy tunable in the range 5.0–20 keV to support conventional single- and multi-wavelength anomalous-dispersion experiments against a wide range of heavy metals. At the standard working energy of 12.659 keV, the monochromated beam is focused to 4.1 µm (V) × 8.5 µm (H) full width at half-maximum at the sample position and the measured photon flux is 1.3 × 1012 photons s−1. The experimental station is equipped with a Pilatus3 6M detector, a micro-diffractometer (MD2S) incorporating a multi-axis goniometer, and a robotic sample exchanger (CATS) with a dewar capacity of 90 samples. This beamline is suitable for structural determination of weakly diffracting crystalline substances, such as biomaterials, including protein, nucleic acids and their complexes. In addition, serial crystallography experiments for determining crystal structures at room temperature are possible. Herein, the current beamline characteristics, technical information for users and some recent scientific highlights are described.