KLKrystian Leski

Krystian Leski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Krystian Leski has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Catalytic oxidation of lean hexane-air and isopropanol-air mixtures using the Ag/Fe2O3/cenosphere catalyst in the fluidized bed reactor

    by Przemysław Migas, Dariusz Bradło, Krystian Leski, Jan Wrona

    The results of the catalytic oxidation of isopropanol and hexane on Fe2O3/cenosphere (Fe2O3/C) and Ag/Fe2O3/cenosphere (Ag/Fe2O3/C) catalysts in a fluidized bed reactor are presented. The Fe2O3/C catalyst was developed by depositing an Fe2O3 layer on cenospheres by chemical vapor deposition of Fe, followed by oxidation of the Fe layer. The Ag/Fe2O3/C catalyst was obtained by Ag/Fe ion exchange. The catalysts were analyzed by AAS, XRD, and SEM-EDS methods, and the composition of the gaseous products formed during the process was determined using an FTIR analyzer. Catalytic oxidation of isopropanol and hexane was carried out at temperatures ranging from 200 to 450 ◦C. Enrichment of the cenosphere coating with Ag significantly improves the catalytic decomposition of isopropanol. The temperature of allmost full conversion of this pollutant to CO2 in the Ag/Fe2O3/C process is approximately 370 ◦C, while the same decomposition using an Fe2O3/C catalyst requires temperatures higher than 450 ◦C. Analysis of the toxicity of exhaust gases generated during the catalytic conversion of hexane showed that up to 450 ◦C, the gaseous products produced are more toxic than hexane. However, a decrease in the toxicity of the gaseous products during isopropanol conversion was achieved, both for the Fe2O3/C and Ag/Fe2O3/C processes

  • Open Access

    Innovative Method of Biomass Combustion in the Binary Fluidised Bed

    by Krystian Leski, Gabriela Berkowicz-Płatek, Witold Żukowski, Jakub Szyman

    In this study, a binary fluidised bed made out of quartz sand and cenospheres for the biomass combustion process was created. Materials were fluidised with air to achieve a vertical density profile (from 0.5 g/cm³ to 1.1 g/cm³) resulting from grains segregation. The density profile was selected to ensure optimal control over the location of the combusted fuel particle. This involved positioning the process as close to the bottom sieve as possible. Fluidised bed combustion was carried out at temperatures of 600 °C, 700 °C, 820 °C and 870 °C using straw, willow and sawmill pellets as fuels. Qualitative and quantitative analysis of flue gases was performed using an FTIR spectrometer. Over 90 % carbon conversion from the biomass to carbon dioxide was achieved at 700 °C. At 820 °C and 870 °C, 100 % of biomass carbon left the reactor as CO 2 . The composition of organic compounds in the process products remained low, reaching a maximum of 3.0 % wt. at 600 °C. To gain further insights into the processes occurring in the immediate vicinity of biomass samples, a complementary TGA/FTIR analysis was conducted. This aimed to clarify the impact of the biomass particle decomposition stage in the fluidised bed combustion process. The proposed mechanism for biomass combustion in the binary fluidised bed contains the particle decomposition stage and the subsequent stage resulting from the coalescence of bubbles containing flammable components and bubbles containing oxidiser.

  • Open Access

    Polyolefin Pyrolysis in Multilayer Fluidized Beds: An Innovative Approach to Obtain Valuable Alternative Fuels

    by Witold Żukowski, Krystian Leski, Gabriela Berkowicz-Płatek, Jan Wrona

    This paper presents the application of two versions of the multilayer fluidized bed made out of two materials with significantly different densities. The first type of fluidized bed was composed of raw cenospheres and quartz sand. The second type of fluidized bed was composed of cenospheres coated with iron oxides and quartz sand. A variable vertical density profiles in the prepared fluidized beds were confirmed, making them suitable for processing polymeric materials, specifically, polyolefins with a density below 1 g/cm3. The polyolefin pyrolysis process was investigated in both versions of the fluidized bed at temperatures of 520, 540, 560, and 590 °C. The products of the pyrolysis were monitored using high-resolution infrared spectroscopy (with a resolution of 1 cm−1). While the process is organized in these fluidized beds, the absence of the accumulation of solid residues is notable. The results show that the pyrolytic gaseous mixture is composed of numerous compounds, namely, unsaturated and saturated aliphatic hydrocarbons and benzene. The possibility of producing a gas rich in ethylene, propylene, and 1-butene during the pyrolysis was demonstrated. Additionally, during the pyrolysis of both polymers, the production of benzene was shown with yields, ranging from 5%wt. in the fluidized bed made out of raw cenospheres to 11 %wt. in the fluidized bed made out of cenospheres modified by iron oxides. Due to the complex nature of the resulting pyrolytic gas, it is suggested that we process the created gaseous mixtures entirely in a steam conversion process, making them a potential source of hydrogen.


  • Open Access

    Numerical Analysis of Minimum Ground Temperature for Heat Extraction in Horizontal Ground Heat Exchangers

    by Krystian Leski, Przemysław Luty, Monika Gwadera, Barbara Larwa

    In this work, numerical simulation calculations were performed to investigate the minimum ground temperature that occurs when extracting thermal energy in a horizontal ground heat exchanger system in the Central European climate. The influence of ground thermal conductivity, heat flux extracted from the ground, periodic interruptions in the operation of the heat exchanger, periodic supply of heat energy to the ground, relative humidity of the ambient air, evaporation rate coefficient, and convective heat transfer coefficient on the ground minimum temperature were investigated. Based on the simulation, it was found that the high value of ground thermal conductivity favorably affects the operation of the installation with a ground heat exchanger. Both the reduction of the maximum heat flux taken from the ground, as well as periodic interruptions in the operation of the exchanger effectively protects the ground against excessive cooling. Further, it was found that heat supply to the ground in summer only slightly raises its minimum temperature, as well as the decrease of the relative humidity of the ambient air and evaporation rate coefficient. The change of the convective heat transfer coefficient has no significant impact on the minimum annual ground temperature.