Lucas Kumosa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lucas Kumosa has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
M. Kumosa
15 shared publicationsD. Armentrout
Dept. of Eng., Denver Univ., CO, USA
12 shared publicationsB. Benedikt
8 shared publicationsD Armentrout
6 shared publicationsM Kumosa
6 shared publicationsEa Armanios
4 shared publications
Latest Publications
- Open Access
- 3 January 2023
- Published by Wiley in Advanced Science
- Vol. 10 (6) , e2205095
Commonly Overlooked Factors in Biocompatibility Studies of Neural Implants
Biocompatibility of cutting‐edge neural implants, surgical tools and techniques, and therapeutic technologies is a challenging concept that can be easily misjudged. For example, neural interfaces are routinely gauged on how effectively they determine active neurons near their recording sites. Tissue integration and toxicity of neural interfaces are frequently assessed histologically in animal models to determine tissue morphological and cellular changes in response to surgical implantation and chronic presence. A disconnect between histological and efficacious biocompatibility exists, however, as neuronal numbers frequently observed near electrodes do not match recorded neuronal spiking activity. The downstream effects of the myriad surgical and experimental factors involved in such studies are rarely examined when deciding whether a technology or surgical process is biocompatible. Such surgical factors as anesthesia, temperature excursions, bleed incidence, mechanical forces generated, and metabolic conditions are known to have strong systemic and thus local cellular and extracellular consequences. Many tissue markers are extremely sensitive to the physiological state of cells and tissues, thus significantly impacting histological accuracy. This review aims to shed light on commonly overlooked factors that can have a strong impact on the assessment of neural biocompatibility and to address the mismatch between results stemming from functional and histological methods.
- 3 January 2023
- Published by Wiley in Advanced Science
- Vol. 10 (6) , e2205095
Open AccessCommonly Overlooked Factors in Biocompatibility Studies of Neural Implants
Biocompatibility of cutting‐edge neural implants, surgical tools and techniques, and therapeutic technologies is a challenging concept that can be easily misjudged. For example, neural interfaces are routinely gauged on how effectively they determine active neurons near their recording sites. Tissue integration and toxicity of neural interfaces are frequently assessed histologically in animal models to determine tissue morphological and cellular changes in response to surgical implantation and chronic presence. A disconnect between histological and efficacious biocompatibility exists, however, as neuronal numbers frequently observed near electrodes do not match recorded neuronal spiking activity. The downstream effects of the myriad surgical and experimental factors involved in such studies are rarely examined when deciding whether a technology or surgical process is biocompatible. Such surgical factors as anesthesia, temperature excursions, bleed incidence, mechanical forces generated, and metabolic conditions are known to have strong systemic and thus local cellular and extracellular consequences. Many tissue markers are extremely sensitive to the physiological state of cells and tissues, thus significantly impacting histological accuracy. This review aims to shed light on commonly overlooked factors that can have a strong impact on the assessment of neural biocompatibility and to address the mismatch between results stemming from functional and histological methods.
- Open Access
- 1 November 2021
- Published by Elsevier in Biomaterials
- Vol. 278, 121143
Profound alterations in brain tissue linked to hypoxic episode after device implantation
- 1 November 2021
- Published by Elsevier in Biomaterials
- Vol. 278, 121143
Open AccessProfound alterations in brain tissue linked to hypoxic episode after device implantation
- Open Access
- 1 September 2020
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 343, 108842
Ice coating –A new method of brain device insertion to mitigate acute injuries
- 1 September 2020
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 343, 108842
Open AccessIce coating –A new method of brain device insertion to mitigate acute injuries
- Open Access
- 1 January 2018
- Published by Elsevier in Acta Biomaterialia
- Vol. 65, 137-149
Gelatin promotes rapid restoration of the blood brain barrier after acute brain injury
- 1 January 2018
- Published by Elsevier in Acta Biomaterialia
- Vol. 65, 137-149
Open AccessGelatin promotes rapid restoration of the blood brain barrier after acute brain injury
- 1 September 2014
- Published by Elsevier in Biomaterials
- Vol. 35 (29) , 8287-8296
Permeability of subcutaneous tissues surrounding long-term implants to oxygen
- 1 September 2014
- Published by Elsevier in Biomaterials
- Vol. 35 (29) , 8287-8296
Permeability of subcutaneous tissues surrounding long-term implants to oxygen
- 1 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 373-376
An AC Electrokinetic Device for the rapid separation and detection of cancer related DNA nanoparticulate biomarkers
The ability to rapidly detect cell free circulating (cfc) DNA and other nanoparticulate disease biomarkers directly in blood is a major challenge for nanomedicine. We now show that AC Electrokinetic (ACE) microelectrode array devices can be used to rapidly isolate and detect cfc-DNA nanoparticulates directly from whole blood and other high conductance samples (plasma, serum etc.). The device shows isolation of naked DNA in water and plasma at >;500bp size and can isolate DNA down to 50 picograms in 50uL of fluid. Disease specific cfc-DNA materials could also be detected directly in blood from patients with Chronic Lymphocytic Leukemia.
- 1 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 373-376
An AC Electrokinetic Device for the rapid separation and detection of cancer related DNA nanoparticulate biomarkers
The ability to rapidly detect cell free circulating (cfc) DNA and other nanoparticulate disease biomarkers directly in blood is a major challenge for nanomedicine. We now show that AC Electrokinetic (ACE) microelectrode array devices can be used to rapidly isolate and detect cfc-DNA nanoparticulates directly from whole blood and other high conductance samples (plasma, serum etc.). The device shows isolation of naked DNA in water and plasma at >;500bp size and can isolate DNA down to 50 picograms in 50uL of fluid. Disease specific cfc-DNA materials could also be detected directly in blood from patients with Chronic Lymphocytic Leukemia.
- 28 July 2010
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 2 (42) , 42ra53
Function of an Implanted Tissue Glucose Sensor for More than 1 Year in Animals
An implanted tissue glucose sensor can provide stable readings of glucose concentrations for more than a year.
- 28 July 2010
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 2 (42) , 42ra53
Function of an Implanted Tissue Glucose Sensor for More than 1 Year in Animals
An implanted tissue glucose sensor can provide stable readings of glucose concentrations for more than a year.
- 1 April 2006
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 421 (1-2) , 1-8
Residual stress analysis in aged graphite/PMR-15 composites using X-ray diffraction
- 1 April 2006
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 421 (1-2) , 1-8
Residual stress analysis in aged graphite/PMR-15 composites using X-ray diffraction
- 24 October 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 12 (5) , 1043-1059
An investigation of moisture and leakage currents in GRP composite hollow cylinders
The applicability of using flat composite plates and hollow core composite cylinders for moisture absorption testing of unidirectional glass/polymer composites used in high voltage composite (non-ceramic) insulators was examined. Two main issues were addressed in this work. First, the effect of specimen geometry (cylinders vs. plates) on moisture absorption by the composites was investigated both numerically and experimentally. Both classical Fickian and non-Fickian diffusions were considered. Subsequently, hollow core cylinders made up of ECR (low seed)-glass fibers and epoxy resin were tested for their high voltage properties under controlled moisture diffusion conditions. The specimens were exposed to warm, moist air and their high voltage properties were ascertained using a modified version of the ANSI test (standard C29.11 Section 7.4.2) for water diffusion electrical testing. It was found that the behavior of the hollow core cylinder and flat plate composite specimens subjected to moisture compared reasonably well experimentally and very well numerically. From the high voltage tests, a direct correlation was found between the amount of moisture that had been absorbed by the specimens and the amount of leakage current that was detected. It was shown that using the thin walled composite cylinders leakage currents could be predicted based on the amount of absorbed moisture in the insulator composites. The predictions can be made based on relatively short term moisture data even if the diffusion process in the composites is anomalous in nature with long times required for full saturation. After additional verifications, considering other composite systems, the hollow core cylinder testing under controlled moisture and high voltage conditions could become a screening test for selecting suitable glass/polymer composites for insulator applications.
- 24 October 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 12 (5) , 1043-1059
An investigation of moisture and leakage currents in GRP composite hollow cylinders
The applicability of using flat composite plates and hollow core composite cylinders for moisture absorption testing of unidirectional glass/polymer composites used in high voltage composite (non-ceramic) insulators was examined. Two main issues were addressed in this work. First, the effect of specimen geometry (cylinders vs. plates) on moisture absorption by the composites was investigated both numerically and experimentally. Both classical Fickian and non-Fickian diffusions were considered. Subsequently, hollow core cylinders made up of ECR (low seed)-glass fibers and epoxy resin were tested for their high voltage properties under controlled moisture diffusion conditions. The specimens were exposed to warm, moist air and their high voltage properties were ascertained using a modified version of the ANSI test (standard C29.11 Section 7.4.2) for water diffusion electrical testing. It was found that the behavior of the hollow core cylinder and flat plate composite specimens subjected to moisture compared reasonably well experimentally and very well numerically. From the high voltage tests, a direct correlation was found between the amount of moisture that had been absorbed by the specimens and the amount of leakage current that was detected. It was shown that using the thin walled composite cylinders leakage currents could be predicted based on the amount of absorbed moisture in the insulator composites. The predictions can be made based on relatively short term moisture data even if the diffusion process in the composites is anomalous in nature with long times required for full saturation. After additional verifications, considering other composite systems, the hollow core cylinder testing under controlled moisture and high voltage conditions could become a screening test for selecting suitable glass/polymer composites for insulator applications.
- 1 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrical Insulation Magazine
- Vol. 21 (4) , 28-41
Failure analyses of nonceramic insulators: part II - the brittle fracture model and failure prevention
In this work, an improved version of a brittle fracture model, based on the formation of nitric acid in service through corona discharges, ozone, and moisture, is presented and is used to explain several different modes of brittle fracture. Similar to Part I, we refer throughout this article to the insulators as nonceramic insulators (NCIs). To prevent brittle fracture in-service, its causes must be first established. To prevent brittle fracture in-service, its causes must be first established.
- 1 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrical Insulation Magazine
- Vol. 21 (4) , 28-41
Failure analyses of nonceramic insulators: part II - the brittle fracture model and failure prevention
In this work, an improved version of a brittle fracture model, based on the formation of nitric acid in service through corona discharges, ozone, and moisture, is presented and is used to explain several different modes of brittle fracture. Similar to Part I, we refer throughout this article to the insulators as nonceramic insulators (NCIs). To prevent brittle fracture in-service, its causes must be first established. To prevent brittle fracture in-service, its causes must be first established.