Agnese Chendi
Agnese Chendi has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Marco Bertolini
Medical Physics Unit, Azienda USL-IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
2 shared publications - Mauro Iori
Medical Physics Unit, Azienda USL-IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
2 shared publications - Alessandra Palma
Centro Nazionale Intelligenza Artificiale e Tecnologie Innovative per la Salute, Istituto Superiore di Sanità, Roma, Italy
1 shared publication - Alessio Bruni
Radiation Oncology Unit, Department of Oncology and Hematology, University Hospital of Modena, Modena, Italy
1 shared publication - Andrea Nitrosi
Medical Physics Unit, Azienda USL-IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
1 shared publication Antonella Rosi
Centro Nazionale Tecnologie Innovative in Sanità Pubblica, Istituto Superiore di Sanità, Roma, Lazio, ITALY
1 shared publication
Latest Publications
- Open Access
- 18 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (14) , 7211
Validation of RayStation Monte Carlo Beam Model for Matched LINACs
Accurate dose calculation is crucial in radiation therapy, particularly when employing advanced techniques such as VMAT. Monte Carlo (MC) algorithms are widely recognized as the gold standard for dose calculation. This study aimed to validate an MC dose calculation model in RayStation® TPS and to compare its performance against the Collapsed Cone (CC). The MC model was evaluated using measured data from four matched Elekta® Versa HD LINACs. Validation followed AAPM TG-157, TG-244 and IAEA TECDOC guidelines, including homogeneous media, heterogeneous media and advanced techniques (VMAT, IMRT, dMLC). MC showed high agreement with measurements, with most results within a 2% dose difference or passing a gamma criteria ≥95%. Performance was comparable or superior to CC in many cases, especially in small-field stereotactic plans. Impact of grid size and statistical uncertainty was assessed to find the optimal values. This study indicated a 2 mm grid size with 0.5% uncertainty as the optimal balance between accuracy and computation time. In conclusion, this study demonstrated that the MC model can provide accurate dose calculations for treatment plans, with computation times compatible with clinical practice. The use of MC appears to be particularly advantageous for advanced techniques and in the presence of tissue heterogeneities.
- 18 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (14) , 7211
Open AccessValidation of RayStation Monte Carlo Beam Model for Matched LINACs
Accurate dose calculation is crucial in radiation therapy, particularly when employing advanced techniques such as VMAT. Monte Carlo (MC) algorithms are widely recognized as the gold standard for dose calculation. This study aimed to validate an MC dose calculation model in RayStation® TPS and to compare its performance against the Collapsed Cone (CC). The MC model was evaluated using measured data from four matched Elekta® Versa HD LINACs. Validation followed AAPM TG-157, TG-244 and IAEA TECDOC guidelines, including homogeneous media, heterogeneous media and advanced techniques (VMAT, IMRT, dMLC). MC showed high agreement with measurements, with most results within a 2% dose difference or passing a gamma criteria ≥95%. Performance was comparable or superior to CC in many cases, especially in small-field stereotactic plans. Impact of grid size and statistical uncertainty was assessed to find the optimal values. This study indicated a 2 mm grid size with 0.5% uncertainty as the optimal balance between accuracy and computation time. In conclusion, this study demonstrated that the MC model can provide accurate dose calculations for treatment plans, with computation times compatible with clinical practice. The use of MC appears to be particularly advantageous for advanced techniques and in the presence of tissue heterogeneities.
- 30 September 2021
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 41 (4) , 689-706
How direct measurements of worker eyes with a Scheimpflug camera can affect lensdose coefficients in interventional radiology
The 2013/59/Euratom Directive reduced the occupational exposure limits for the lens. Since it has become crucial to estimate the dose absorbed by the lens, we have studied the individual variability of exposed workers’ ocular conformations with respect to the data estimated from their personal dosimetry. The anterior eye conformations of 45 exposed workers were acquired using Scheimpflug imaging and classified according to their sight conditions (emmetropia, myopia or hypermetropia). Three eye models were computed, with two lens reconstructions, and implemented in an interventional radiology scenario using Monte Carlo code. The models were dosimetrically analysed by simulating setup A, a theoretical monoenergetic and isotropic photon source (10–150 keV) and setup B, a more realistic interventional setting with an angiographic x-ray unit (50, 75, 100 kV peak). Scheimpflug imaging provided an average anterior chamber depth of (6.4 ± 0.5) mm and a lens depth of (3.9 ± 0.3) mm, together with a reconstructed equatorial lens length of (7.1–10.1) mm. Using these data for model reconstruction, dose coefficients (DCs) were simulated for all ocular structures. Regardless of the eye model used, the DCs showed a similar trend with radiation energy, which highlighted that for the same energy and setup, no significant dependence on ocular morphology and workers’ visual conditions was observed. The maximum difference obtained did not exceed 1% for all eye models or structures analysed. Therefore, the individual variabilities of worker ocular anatomy do not require any additional correction, compared to the personal dosimetry data measured with a dedicated lens dosimeter. To estimate the dose absorbed by the other eye structures, it is, instead, essential to know the spectrum of the source that has generated the irradiation, since there are differences between monoenergetic sources and more realistic angiographic units.
- 30 September 2021
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 41 (4) , 689-706
How direct measurements of worker eyes with a Scheimpflug camera can affect lensdose coefficients in interventional radiology
The 2013/59/Euratom Directive reduced the occupational exposure limits for the lens. Since it has become crucial to estimate the dose absorbed by the lens, we have studied the individual variability of exposed workers’ ocular conformations with respect to the data estimated from their personal dosimetry. The anterior eye conformations of 45 exposed workers were acquired using Scheimpflug imaging and classified according to their sight conditions (emmetropia, myopia or hypermetropia). Three eye models were computed, with two lens reconstructions, and implemented in an interventional radiology scenario using Monte Carlo code. The models were dosimetrically analysed by simulating setup A, a theoretical monoenergetic and isotropic photon source (10–150 keV) and setup B, a more realistic interventional setting with an angiographic x-ray unit (50, 75, 100 kV peak). Scheimpflug imaging provided an average anterior chamber depth of (6.4 ± 0.5) mm and a lens depth of (3.9 ± 0.3) mm, together with a reconstructed equatorial lens length of (7.1–10.1) mm. Using these data for model reconstruction, dose coefficients (DCs) were simulated for all ocular structures. Regardless of the eye model used, the DCs showed a similar trend with radiation energy, which highlighted that for the same energy and setup, no significant dependence on ocular morphology and workers’ visual conditions was observed. The maximum difference obtained did not exceed 1% for all eye models or structures analysed. Therefore, the individual variabilities of worker ocular anatomy do not require any additional correction, compared to the personal dosimetry data measured with a dedicated lens dosimeter. To estimate the dose absorbed by the other eye structures, it is, instead, essential to know the spectrum of the source that has generated the irradiation, since there are differences between monoenergetic sources and more realistic angiographic units.
- 2 June 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (11) , 11NT02
Physical characterization of a novel wireless DRX Plus 3543C using both a carbon nano tube (CNT) mobile x-ray system and a traditional x-ray system
This work aims to characterize the novel DRX Plus 3543C detector in terms of detective quantum efficiency (DQE) using both a mobile x-ray system called Carestream DRX Revolution Nano and a traditional x-ray system (Carestream DRX Evolution). We used the commercial system DRX Revolution Nano, equipped with a new x-ray source based on CNT technology and field emission (FE) as the electron emitter (cathode). An innovative aspect of this device is its intrinsic selection of the focal spot size. We tested the system using three IEC-specified beam qualities (RQA3, 5 and 7) in terms of modulation transfer function (MTF), normalized noise power spectra (NNPS) and DQE as defined in the IEC 62220-1-1:2015. We compared the results obtained using DRX Revolution Nano and DRX Evolution with correlation and with Bland–Altman plots to study their agreement. RQA3 MTF is slightly lower than the RQA5 and 7 curves between 0.5 and 2.5 cycles mm −1 . We measured MTF values of about 0.6 at 1 lp mm −1 and about 0.28 lp mm −1 at 2 lp mm −1 . The NNPS curves show a decreasing trend with the energy regarding the DRX Revolution Nano. On the other hand, the DRX Evolution NNPS curve at RQA3 is greater than the one at RQA5, but the one at RQA5 is less than the one at RQA7. The DQE(0) ranged between about 0.82 (DRX Evolution at RQA3) and 0.54 (DRX Evolution at RQA7). As expected, the squared Pearson’s correlation coefficients between the two x-ray tubes were always in an optimal agreement, and Bland–Altman plots confirmed a substantial equivalence between the two physical characterizations of the wireless detector. In conclusion, we can show that the dynamic focal selection of the system equipped with CNT does not play a substantial role in image quality compared to a traditional system in terms of physical characterisation of the detector in our measurement conditions.
- 2 June 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (11) , 11NT02
Physical characterization of a novel wireless DRX Plus 3543C using both a carbon nano tube (CNT) mobile x-ray system and a traditional x-ray system
This work aims to characterize the novel DRX Plus 3543C detector in terms of detective quantum efficiency (DQE) using both a mobile x-ray system called Carestream DRX Revolution Nano and a traditional x-ray system (Carestream DRX Evolution). We used the commercial system DRX Revolution Nano, equipped with a new x-ray source based on CNT technology and field emission (FE) as the electron emitter (cathode). An innovative aspect of this device is its intrinsic selection of the focal spot size. We tested the system using three IEC-specified beam qualities (RQA3, 5 and 7) in terms of modulation transfer function (MTF), normalized noise power spectra (NNPS) and DQE as defined in the IEC 62220-1-1:2015. We compared the results obtained using DRX Revolution Nano and DRX Evolution with correlation and with Bland–Altman plots to study their agreement. RQA3 MTF is slightly lower than the RQA5 and 7 curves between 0.5 and 2.5 cycles mm −1 . We measured MTF values of about 0.6 at 1 lp mm −1 and about 0.28 lp mm −1 at 2 lp mm −1 . The NNPS curves show a decreasing trend with the energy regarding the DRX Revolution Nano. On the other hand, the DRX Evolution NNPS curve at RQA3 is greater than the one at RQA5, but the one at RQA5 is less than the one at RQA7. The DQE(0) ranged between about 0.82 (DRX Evolution at RQA3) and 0.54 (DRX Evolution at RQA7). As expected, the squared Pearson’s correlation coefficients between the two x-ray tubes were always in an optimal agreement, and Bland–Altman plots confirmed a substantial equivalence between the two physical characterizations of the wireless detector. In conclusion, we can show that the dynamic focal selection of the system equipped with CNT does not play a substantial role in image quality compared to a traditional system in terms of physical characterisation of the detector in our measurement conditions.