Beatriz Gómez-Nieto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Beatriz Gómez-Nieto has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- María Jesús Gismera
Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Avda. Francisco Tomás y Valiente, 7, Universidad Autónoma de Madrid, 28049 Madrid, Spain
8 shared publications - Jesús Rodriguez Procopio
Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Avda. Francisco Tomás y Valiente, 7, Universidad Autónoma de Madrid, 28049 Madrid, Spain
7 shared publications - Ma Teresa Sevilla
Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Avda. Francisco Tomás y Valiente, 7, Universidad Autónoma de Madrid, 28049 Madrid, Spain
6 shared publications María Teresa Sevilla
Avda. Francisco Tomás y Valiente, 7, Universidad Autónoma de Madrid, 28049, Madrid, Spain
5 shared publicationsJesús R. Procopio
4 shared publicationsMaría Jesús Gismera
Avda. Francisco Tomás y Valiente, 7, Universidad Autónoma de Madrid, 28049, Madrid, Spain
4 shared publications
Latest Publications
- Open Access
- 22 May 2026
- Published by Elsevier in SSRN Electronic Journal
HYDROPHOBIC NATURAL DEEP EUTECTIC SOLVENT-BASED DLLME FOR THE GREEN HPLC DETERMINATION OF PARABEN AND ALCOHOL PRESERVATIVES IN WATER SAMPLES
A simple, rapid, and environmentally friendly dispersive liquid-liquid microextraction (DLLME) method using hydrophobic natural deep eutectic solvents (NADES) was developed for the simultaneous determination of six parabens and phenoxyethanol in water samples. The extraction performance of several NADES composed of thymol, menthol, and fatty acids was evaluated, selecting a thymol: decanoic acid system (2:1 molar ratio) as the optimal extractant. Critical experimental variables were optimized using a multivariate approach combining Plackett-Burman and central composite designs. Under optimal conditions, the method provided high enrichment factors (85 - 133), good precision (RSD < 13%), and limits of detection between 0.065 and 0.56 ng mL-1. The method was applied to analyze different water samples, including tap, river, and wastewater samples obtaining recoveries between 78% and 118% for all the analytes in the spiked samples. The greenness and practicability of the developed method were evaluated using ChlorTox, AGREE, AGREEprep, and BAGI metrics, confirming the reduced environmental impact of the proposed approach, mainly due to the use of bio-based solvents and miniaturized extraction. This method represents a sustainable and efficient alternative for monitoring emerging preservatives in environmental waters.
- 22 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHYDROPHOBIC NATURAL DEEP EUTECTIC SOLVENT-BASED DLLME FOR THE GREEN HPLC DETERMINATION OF PARABEN AND ALCOHOL PRESERVATIVES IN WATER SAMPLES
A simple, rapid, and environmentally friendly dispersive liquid-liquid microextraction (DLLME) method using hydrophobic natural deep eutectic solvents (NADES) was developed for the simultaneous determination of six parabens and phenoxyethanol in water samples. The extraction performance of several NADES composed of thymol, menthol, and fatty acids was evaluated, selecting a thymol: decanoic acid system (2:1 molar ratio) as the optimal extractant. Critical experimental variables were optimized using a multivariate approach combining Plackett-Burman and central composite designs. Under optimal conditions, the method provided high enrichment factors (85 - 133), good precision (RSD < 13%), and limits of detection between 0.065 and 0.56 ng mL-1. The method was applied to analyze different water samples, including tap, river, and wastewater samples obtaining recoveries between 78% and 118% for all the analytes in the spiked samples. The greenness and practicability of the developed method were evaluated using ChlorTox, AGREE, AGREEprep, and BAGI metrics, confirming the reduced environmental impact of the proposed approach, mainly due to the use of bio-based solvents and miniaturized extraction. This method represents a sustainable and efficient alternative for monitoring emerging preservatives in environmental waters.
- Open Access
Optimization of a Natural-Deep-Eutectic-Solvent-Based Dispersive Liquid–Liquid Microextraction Method for the Multi-Target Determination of Emerging Contaminants in Wastewater
The widespread discharge of industrial and urban waste has led to significant increases in the environmental concentrations of numerous chemical substances. This work presents the development of a simple and environmentally friendly dispersive liquid–liquid microextraction (DLLME) method based on a hydrophobic natural deep eutectic solvent (NADES) for the determination of selected compounds from benzotriazole, benzothiazole, paraben, and UV filter families in wastewater samples. Of the twelve NADES formulations evaluated, those composed of a 4:1 molar ratio of thymol and menthol presented the highest extraction efficiencies. The influence of key experimental variables such as the pH of the aqueous sample, the ratio of NADES phase to sample volume, and the extraction time on the extraction efficiency was investigated using a multivariate optimization. Under optimal conditions, relative standard deviations below 15% and recoveries for spiked wastewater samples ranged between 82 and 108%, demonstrating the suitability of the method for routine water-quality monitoring. The sustainability and practicality of the developed method was evaluated using the assessment tools ChlorTox, AGREEprep, AGRRE, and BAGI, obtaining scores of 0.005 g in the NADES-DLLME method, 0.70, 0.52, and 72.5, respectively, demonstrating that the method is green and reliable.
Open AccessOptimization of a Natural-Deep-Eutectic-Solvent-Based Dispersive Liquid–Liquid Microextraction Method for the Multi-Target Determination of Emerging Contaminants in Wastewater
The widespread discharge of industrial and urban waste has led to significant increases in the environmental concentrations of numerous chemical substances. This work presents the development of a simple and environmentally friendly dispersive liquid–liquid microextraction (DLLME) method based on a hydrophobic natural deep eutectic solvent (NADES) for the determination of selected compounds from benzotriazole, benzothiazole, paraben, and UV filter families in wastewater samples. Of the twelve NADES formulations evaluated, those composed of a 4:1 molar ratio of thymol and menthol presented the highest extraction efficiencies. The influence of key experimental variables such as the pH of the aqueous sample, the ratio of NADES phase to sample volume, and the extraction time on the extraction efficiency was investigated using a multivariate optimization. Under optimal conditions, relative standard deviations below 15% and recoveries for spiked wastewater samples ranged between 82 and 108%, demonstrating the suitability of the method for routine water-quality monitoring. The sustainability and practicality of the developed method was evaluated using the assessment tools ChlorTox, AGREEprep, AGRRE, and BAGI, obtaining scores of 0.005 g in the NADES-DLLME method, 0.70, 0.52, and 72.5, respectively, demonstrating that the method is green and reliable.
- Open Access
- 27 June 2024
- Published by Elsevier in Green Analytical Chemistry
- Vol. 10
Green dispersive liquid–liquid microextraction of copper and nickel using a dual-function hydrophobic natural deep eutectic solvent for the analysis of water samples
- 27 June 2024
- Published by Elsevier in Green Analytical Chemistry
- Vol. 10
Open AccessGreen dispersive liquid–liquid microextraction of copper and nickel using a dual-function hydrophobic natural deep eutectic solvent for the analysis of water samples
- Open Access
- 18 July 2023
- Published by Elsevier in Green Analytical Chemistry
- Vol. 6
A slurry sampling high resolution continuum source graphite furnace atomic absorption spectrometry approach to determine metals in biomass bottom ash
- 18 July 2023
- Published by Elsevier in Green Analytical Chemistry
- Vol. 6
Open AccessA slurry sampling high resolution continuum source graphite furnace atomic absorption spectrometry approach to determine metals in biomass bottom ash
- Open Access
- 2 February 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (9) , 1105-1115
An environmentally friendly approach for the characterization of construction materials: determination of trace, minor, and major elements by slurry sampling high-resolution continuum source graphite furnace atomic absorption spectrometry
A slurry sampling method was developed for the fast determination of Pb, Ni, Fe, and Mn in construction materials by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS). For sample introduction into the GF, stable slurries were prepared by sonicating 10 mg of ground solid sample in 10.0 mL of 1% (v/v) Triton X-100 and 1% (v/v) HNO3 solution for 1.0 min. The determination of the four elements was carried out in three measurement runs, with Ni and Fe being determined simultaneously. The HR-CS GFAAS measurements were performed using analytical lines with adequate sensitivity, considering the content of each element in the material: Pb at 283.306 nm (42%), Mn at 403.080 nm (6.7%), Ni at 232.003 nm (100%) and Fe at 232.036 nm (1.4%). The pyrolysis and atomization temperatures and the use of chemical modifiers were optimized using both aqueous standards and slurry samples. At optimal conditions, samples with concentrations of Pb from 1.5 to 80 μg g−1, Ni from 4.0 to 75 μg g−1, Mn from 2.0 to 600 μg g−1, and Fe from 0.15 to 60 mg g−1 could be determined using a unique sample suspension. To assess the validity of the method, a fly ash certified reference material (CRM) was analysed using the slurry sampling HR-CS GFAAS method; this CRM and the construction material samples were also analysed by HR-CS GFAAS after the digestion of the samples. The obtained results using both methods were statistically comparable (Student's paired t-test for two independent methods at a 95% confidence level) demonstrating the suitability of the proposed method.
- 2 February 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (9) , 1105-1115
Open AccessAn environmentally friendly approach for the characterization of construction materials: determination of trace, minor, and major elements by slurry sampling high-resolution continuum source graphite furnace atomic absorption spectrometry
A slurry sampling method was developed for the fast determination of Pb, Ni, Fe, and Mn in construction materials by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS). For sample introduction into the GF, stable slurries were prepared by sonicating 10 mg of ground solid sample in 10.0 mL of 1% (v/v) Triton X-100 and 1% (v/v) HNO3 solution for 1.0 min. The determination of the four elements was carried out in three measurement runs, with Ni and Fe being determined simultaneously. The HR-CS GFAAS measurements were performed using analytical lines with adequate sensitivity, considering the content of each element in the material: Pb at 283.306 nm (42%), Mn at 403.080 nm (6.7%), Ni at 232.003 nm (100%) and Fe at 232.036 nm (1.4%). The pyrolysis and atomization temperatures and the use of chemical modifiers were optimized using both aqueous standards and slurry samples. At optimal conditions, samples with concentrations of Pb from 1.5 to 80 μg g−1, Ni from 4.0 to 75 μg g−1, Mn from 2.0 to 600 μg g−1, and Fe from 0.15 to 60 mg g−1 could be determined using a unique sample suspension. To assess the validity of the method, a fly ash certified reference material (CRM) was analysed using the slurry sampling HR-CS GFAAS method; this CRM and the construction material samples were also analysed by HR-CS GFAAS after the digestion of the samples. The obtained results using both methods were statistically comparable (Student's paired t-test for two independent methods at a 95% confidence level) demonstrating the suitability of the proposed method.