PBPablo D. Bastidas

Pablo D. Bastidas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Pablo D. Bastidas has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Simon M. Rowland

    School of Electrical and Electronic Engineering, The University of Manchester, Manchester, UK

    3 shared publications
  • Harry McDonald

    Department of Electrical & Electronic Engineering, School of Engineering, The University of Manchester, Manchester, UK

    2 shared publications
  • Suzanne Morsch

    Corrosion and Protection Centre, Department of Materials, The University of Manchester, Nancy Rothwell Building, Oxford Rd, Manchester M13 9PL, UK

    2 shared publications
  • Simon M. Rowland

    Department of Electrical and Electronic Engineering, The University of Manchester, Manchester, U.K.

    1 shared publication
  • Simon Rowland

    School of Electrical and Electronic Engineering, The University of Manchester, Manchester, United Kingdom

    1 shared publication

Latest Publications

  • The Importance of Scale in Testing for Electrical Tree Growth

    by H. McDonald, S. M. Rowland, P. Bastidas

    The importance of electrical trees and interfacial electrical track growth as aging processes in high voltage polymeric insulation systems is well established. It is argued that the majority of testing using needle-plane electrode systems with small insulation gaps is not representative of insulation in high voltage service conditions. In particular, the relationship between partial discharge magnitude, tree length and sample scale is considered. Track growth has been considered in laboratory samples with a 90 mm gap between electrodes. This arrangement allows the channels to grow independent of their proximity to the electrodes. The applied voltage and sample thickness, as well as the electrical field, are critical parameters to be considered. The growth of channels here was voltage limited. Smaller and lower voltage tests cannot replicate this behavior because in small samples tree channels are always in close proximity to, and dominated by, the electrode geometry.


  • Chemical Analysis of Solid Insulation Degradation using the AFM-IR Technique

    by Harry McDonald, Pablo D. Bastidas, Simon Rowland, Suzanne Morsch

    To enable the continued development of power transmission cabling, an understanding of the processes which result in their failures is essential. In order to do so, powerful analysis techniques are required. However, those which consider chemical degradation are lagging behind those for visible degradation. This paper presents the Atomic Force Microscopy - Infrared Spectroscopy (AFM-IR) chemical analysis technique, which can provide surface chemical analysis with resolution of ~50 nm across the infrared spectrum. Two cases are considered: interfacial tracking between epoxy and silicone rubber, and the degraded region formed in front of a needle tip in the electrical tree initiation process. The results obtained using AFM-IR are compared to the outcomes from other techniques. It is found that AFM-IR offers a unique and powerful insight into visible and non-visible degradation of solid dielectrics.

  • AFM-IR insights into the chemistry of interfacial tracking

    by Suzanne Morsch, Pablo D. Bastidas, Simon M. Rowland

    AFM-IR provides detailed sub-micron chemical maps of the local damage inflicted by partial discharges.


  • Interfacial aging in composite insulators as a result of partial discharge activity

    by Pablo D. Bastidas, Simon M. Rowland

    High voltage outdoor composite insulators used on transmission lines can be subject to degradation due to electrical discharge activity at the core-sheath interface. A methodology is described to explore the effect of de-bonding or loss of adhesion between the sheath and core in composite insulators. The use of planar geometry materials allows interfacial pressure to be varied and facilitates physical and optical imaging of the tracking as it grows and chemical analysis of the samples after aging. The associated electrode geometry allowed the tracking to develop in a constant field, unaffected by the earth electrode. Low pressure between the materials accelerated the growth the tracks. A correlation between partial discharge magnitude and track development is identified. Electrical tree growth was also observed penetrating the epoxy resin, initiated from the interfacial tracks.


  • Developing test methods for interfacial ageing in composite insulators

    by Pablo D. Bastidas, Simon M. Rowland

    High voltage insulation systems consist of a combination of different insulating materials, exposed to multiple stresses during operation. Outdoor composite insulators used in transmission lines are typically made of two solid polymeric materials bonded together to form the insulator. Work reported here contributes to the evaluation of degradation within internal interfaces by developing tests to investigate interfacial tracking, with a view to replicating the tracking phenomena seen within composite insulators in service. The present paper highlights high voltage tests on dielectric interfaces with needle electrodes generating local high fields to initiate tracking. FEA has been used to design an experiment with controlled electric field magnitudes over a 1 m sample. Moreover, information from monitoring partial discharges and surface temperature is used to understand the inception and propagation of tracking activity within the structure.