Gabriel Maier Cocco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gabriel Maier Cocco has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Martin Wolter
Technical University of Dresden , Dresden , Germany
4 shared publications - Robinson Figueiredo de Camargo
Power Electronics and Control Research Group, Federal University of Santa Maria, Santa Maria, Brazil
4 shared publications - Carlos Antônio De Souza
Power Electronics and Control Research Group, Federal University of Santa Maria, Santa Maria, Brazil
2 shared publications - Felipe Bovolini Grigoletto
Federal University of Pampa
2 shared publications - Humberto Pinheiro
Federal University of Santa Maria, Santa Maria, Brazil
2 shared publications - João Pedro Scherer Cipriani
Universidade Federal de Santa Maria
2 shared publications
Latest Publications
- Open Access
- 25 July 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 264
DC bus ancillary controller enabling fast frequency response from fast charging stations
- 25 July 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 264
Open AccessDC bus ancillary controller enabling fast frequency response from fast charging stations
- Open Access
- 25 June 2026
- Published by Elsevier in Control Engineering Practice
- Vol. 175
FW-M²PC: Projection-free modulated model predictive control of grid-tied converters
- 25 June 2026
- Published by Elsevier in Control Engineering Practice
- Vol. 175
Open AccessFW-M²PC: Projection-free modulated model predictive control of grid-tied converters
- Open Access
- 17 December 2024
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 29
OSV-MPC for Harmonic and Zero-Sequence Compensation in Four-Wire Off-Grid Microgeneration Systems Based on SEIG
This paper proposes a finite control set model predictive control (FCS-MPC) strategy to address voltage regulation in isolated four-wire microgeneration systems based on self-excited induction generators. The FCS-MPC approach enables a simpler and more functional imbalance controller design. The controller determines the optimal switching vector through a cost function that employs a weighting factor for the different control variables. It effectively tracks distorted current references and prevents voltage imbalance, even in a system without frequency regulation. The employed inverter is a four-leg voltage source inverter, also known as a distribution static synchronous compensator, which provides the necessary reactive power and compensates for harmonic content along with the zero-sequence component, ensuring balanced three-phase voltages at the point of common coupling, even with unbalanced loads. The proposed control leverages the instantaneous power theory for synchronization, thereby replacing methods such as the phase-locked loop. Experimental results validate the effectiveness of the proposed control approach and assess the performance of the system in accordance with power quality standards.
- 17 December 2024
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 29
Open AccessOSV-MPC for Harmonic and Zero-Sequence Compensation in Four-Wire Off-Grid Microgeneration Systems Based on SEIG
This paper proposes a finite control set model predictive control (FCS-MPC) strategy to address voltage regulation in isolated four-wire microgeneration systems based on self-excited induction generators. The FCS-MPC approach enables a simpler and more functional imbalance controller design. The controller determines the optimal switching vector through a cost function that employs a weighting factor for the different control variables. It effectively tracks distorted current references and prevents voltage imbalance, even in a system without frequency regulation. The employed inverter is a four-leg voltage source inverter, also known as a distribution static synchronous compensator, which provides the necessary reactive power and compensates for harmonic content along with the zero-sequence component, ensuring balanced three-phase voltages at the point of common coupling, even with unbalanced loads. The proposed control leverages the instantaneous power theory for synchronization, thereby replacing methods such as the phase-locked loop. Experimental results validate the effectiveness of the proposed control approach and assess the performance of the system in accordance with power quality standards.
- 27 November 2023
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 71 (12) , 1040-1050
DC voltage ancillary controller for dynamic security of shunt-compensated microgrids
Modern power systems require special features from the distributed energy resources especially to meet the power quality and dynamic security. The distribution static synchronous compensator (DSTATCOM) has a safe DC voltage operating range that is often unexplored. Self-excited induction generators (SEIGs) with a shunt DSTATCOM is a well-known solution for low-power, low-cost generation. These systems may have poor robustness against surges and contingencies. This paper proposes an ancillary controller as a supplement in the shunt compensation of an off-grid distributed generation system powered by SEIGs. The controller consists of a variable structure that uses an adequate DC bus capacitor voltage range to provide fast frequency response (FFR) with soft recovery. The control performance for fault rejection is evaluated as well as for load disturbances and generation contingency. Simulation results are presented to demonstrate system operation and compensator performance.
- 27 November 2023
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 71 (12) , 1040-1050
DC voltage ancillary controller for dynamic security of shunt-compensated microgrids
Modern power systems require special features from the distributed energy resources especially to meet the power quality and dynamic security. The distribution static synchronous compensator (DSTATCOM) has a safe DC voltage operating range that is often unexplored. Self-excited induction generators (SEIGs) with a shunt DSTATCOM is a well-known solution for low-power, low-cost generation. These systems may have poor robustness against surges and contingencies. This paper proposes an ancillary controller as a supplement in the shunt compensation of an off-grid distributed generation system powered by SEIGs. The controller consists of a variable structure that uses an adequate DC bus capacitor voltage range to provide fast frequency response (FFR) with soft recovery. The control performance for fault rejection is evaluated as well as for load disturbances and generation contingency. Simulation results are presented to demonstrate system operation and compensator performance.
- 9 March 2022
- Published by Springer Nature in Journal of Control, Automation and Electrical Systems
- Vol. 33 (5) , 1563-1575
Modeling and Control of Hydro-PV Hybrid Power System with Three-Phase Three-Leg Split-Source Inverter
- 9 March 2022
- Published by Springer Nature in Journal of Control, Automation and Electrical Systems
- Vol. 33 (5) , 1563-1575
Modeling and Control of Hydro-PV Hybrid Power System with Three-Phase Three-Leg Split-Source Inverter
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Control of three-phase four-wire SSI DSTATCOM integrated to PV generation system
Hybrid systems play an important role in standalone power generation mainly due its flexibility and reliability. Integration of different generation sources can require various converter topologies. This paper proposes a control strategy for hybrid hydro-PV generation system employing a three-phase four-wire Split-Source Inverter (SSI). The SSI has the ability to feed ac loads with boost characteristic employing reduced switch count. In addition, the proposed control strategy ensures balanced output ac voltages under unbalanced loads providing the required active and reactive power. Simulation results are presented to demonstrate the good performance of the proposed control strategy under balanced and unbalanced linear loads.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Control of three-phase four-wire SSI DSTATCOM integrated to PV generation system
Hybrid systems play an important role in standalone power generation mainly due its flexibility and reliability. Integration of different generation sources can require various converter topologies. This paper proposes a control strategy for hybrid hydro-PV generation system employing a three-phase four-wire Split-Source Inverter (SSI). The SSI has the ability to feed ac loads with boost characteristic employing reduced switch count. In addition, the proposed control strategy ensures balanced output ac voltages under unbalanced loads providing the required active and reactive power. Simulation results are presented to demonstrate the good performance of the proposed control strategy under balanced and unbalanced linear loads.
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 630-635
Finite Set Model Predictive Control of Four-Leg Split-Source Inverters
The four-leg inverter is a commonly used solution to feed stand-alone loads since it provides three-phase balanced voltages even under unbalanced conditions. On the other hand, when the system requires input sources with reduced dc voltage, the Split-Source Inverter (SSI) is an interesting option to provide a inversion stage with boost capability. By combining the presented features, this paper presents a Finite Set Model Predictive Control (FS-MPC) for a four-leg SSI. Thus, a cost function composed by the input current and output voltages is minimized. Finally, simulation results are presented to explore the performance of the proposed approach under different operating conditions.
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 630-635
Finite Set Model Predictive Control of Four-Leg Split-Source Inverters
The four-leg inverter is a commonly used solution to feed stand-alone loads since it provides three-phase balanced voltages even under unbalanced conditions. On the other hand, when the system requires input sources with reduced dc voltage, the Split-Source Inverter (SSI) is an interesting option to provide a inversion stage with boost capability. By combining the presented features, this paper presents a Finite Set Model Predictive Control (FS-MPC) for a four-leg SSI. Thus, a cost function composed by the input current and output voltages is minimized. Finally, simulation results are presented to explore the performance of the proposed approach under different operating conditions.