Paul Blazek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Paul Blazek has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Milo M. Lin
The University of Texas Southwestern Medical Center
2 shared publications - Steven Vernino
Department of Neurology, University of Texas Southwestern Medical Center, Dallas, USA
2 shared publications Amy Conger
Univ Texas SW Med Ctr Dallas, Dept Neurol & Neurotherapeut, Dallas, TX 75390 USA
1 shared publicationAri Green
Univ Calif San Francisco, Dept Neurol, San Francisco, CA USA
1 shared publication- Benjamin M. Greenberg
Department of Neurology, University of Texas Southwestern Medical Center, Dallas, TX, USA
1 shared publication Beverley Adams-Huet
Department of Clinical Sciences, University of Texas Southwestern, Dallas, USA
1 shared publication
Latest Publications
- 19 February 2024
- Published by Springer Nature in Nature Computational Science
- Vol. 4 (2) , 110-118
Automated discovery of algorithms from data
To automate the discovery of new scientific and engineering principles, artificial intelligence must distill explicit rules from experimental data. This has proven difficult because existing methods typically search through the enormous space of possible functions. Here we introduce deep distilling, a machine learning method that does not perform searches but instead learns from data using symbolic essence neural networks and then losslessly condenses the network parameters into a concise algorithm written in computer code. This distilled code, which can contain loops and nested logic, is equivalent to the neural network but is human-comprehensible and orders-of-magnitude more compact. On arithmetic, vision and optimization tasks, the distilled code is capable of out-of-distribution systematic generalization to solve cases orders-of-magnitude larger and more complex than the training data. The distilled algorithms can sometimes outperform human-designed algorithms, demonstrating that deep distilling is able to discover generalizable principles complementary to human expertise.
- 19 February 2024
- Published by Springer Nature in Nature Computational Science
- Vol. 4 (2) , 110-118
Automated discovery of algorithms from data
To automate the discovery of new scientific and engineering principles, artificial intelligence must distill explicit rules from experimental data. This has proven difficult because existing methods typically search through the enormous space of possible functions. Here we introduce deep distilling, a machine learning method that does not perform searches but instead learns from data using symbolic essence neural networks and then losslessly condenses the network parameters into a concise algorithm written in computer code. This distilled code, which can contain loops and nested logic, is equivalent to the neural network but is human-comprehensible and orders-of-magnitude more compact. On arithmetic, vision and optimization tasks, the distilled code is capable of out-of-distribution systematic generalization to solve cases orders-of-magnitude larger and more complex than the training data. The distilled algorithms can sometimes outperform human-designed algorithms, demonstrating that deep distilling is able to discover generalizable principles complementary to human expertise.
- 22 September 2021
- Published by Springer Nature in Nature Computational Science
- Vol. 1 (9) , 607-618
Explainable neural networks that simulate reasoning
- 22 September 2021
- Published by Springer Nature in Nature Computational Science
- Vol. 1 (9) , 607-618
Explainable neural networks that simulate reasoning
- Open Access
- 11 August 2016
- Published by Springer Nature
- p. 287-300
“La Chispa de la Ciudad de México”: Co-creation of Organizational Innovations and Its Implications for Managing Innovation
- 11 August 2016
- Published by Springer Nature
- p. 287-300
Open Access“La Chispa de la Ciudad de México”: Co-creation of Organizational Innovations and Its Implications for Managing Innovation
- 24 July 2013
- Published by Springer Nature in Clinical Autonomic Research
- Vol. 23 (6) , 297-303
Dynamic pupillometry as an autonomic testing tool
Objective To determine normal values for pupillometry indices in healthy control subjects and to examine these indices in patients with autonomic dysfunction and healthy controls. Methods Infrared video pupillometry was used to investigate the pupil response to a brief light flash in 79 healthy controls, 28 patients with normal autonomic function (composite autonomic severity score, CASS < 2), and 26 patients with moderate to severe autonomic failure (CASS > 4) seen in our autonomic laboratory from January 2008 to June 2011. In six subjects, we examined the effects of varying light stimulus intensity and light stimulus duration. Descriptive analysis, correlation, and ANCOVA adjusted for age were performed. Results We determined eight indices corresponding to parasympathetic and sympathetic pupil function. Baseline pupil diameter (BPD), maximum constriction velocity (MCV), absolute constriction amplitude (ACA), and maximum dilation velocity (MDV) negatively correlated with age (p < 0.01) among controls. MCV and ACA increased with increasing intensity of light stimulus from 3.5 to 112 μW. Indices of parasympathetic pupil innervation (MCV and ACA) were lower in the high CASS group compared to others (p < 0.0001). Indices of sympathetic pupil function, time to reach 75 % of initial resting diameter during pupillary dilation (T¾), and dilation velocity at T¾ (DV¾) did not differ significantly in the three study groups. However, T¾ corrected for the magnitude of pupillary constriction (T¾:ACA) was higher in the high CASS group suggesting sympathetic dysfunction in that group (p = 0.0003). Conclusions Indices of pupillomotor function significantly differ between patients with moderate to severe autonomic failure and healthy controls.
- 24 July 2013
- Published by Springer Nature in Clinical Autonomic Research
- Vol. 23 (6) , 297-303
Dynamic pupillometry as an autonomic testing tool
Objective To determine normal values for pupillometry indices in healthy control subjects and to examine these indices in patients with autonomic dysfunction and healthy controls. Methods Infrared video pupillometry was used to investigate the pupil response to a brief light flash in 79 healthy controls, 28 patients with normal autonomic function (composite autonomic severity score, CASS < 2), and 26 patients with moderate to severe autonomic failure (CASS > 4) seen in our autonomic laboratory from January 2008 to June 2011. In six subjects, we examined the effects of varying light stimulus intensity and light stimulus duration. Descriptive analysis, correlation, and ANCOVA adjusted for age were performed. Results We determined eight indices corresponding to parasympathetic and sympathetic pupil function. Baseline pupil diameter (BPD), maximum constriction velocity (MCV), absolute constriction amplitude (ACA), and maximum dilation velocity (MDV) negatively correlated with age (p < 0.01) among controls. MCV and ACA increased with increasing intensity of light stimulus from 3.5 to 112 μW. Indices of parasympathetic pupil innervation (MCV and ACA) were lower in the high CASS group compared to others (p < 0.0001). Indices of sympathetic pupil function, time to reach 75 % of initial resting diameter during pupillary dilation (T¾), and dilation velocity at T¾ (DV¾) did not differ significantly in the three study groups. However, T¾ corrected for the magnitude of pupillary constriction (T¾:ACA) was higher in the high CASS group suggesting sympathetic dysfunction in that group (p = 0.0003). Conclusions Indices of pupillomotor function significantly differ between patients with moderate to severe autonomic failure and healthy controls.
- 1 December 2012
- Published by Elsevier in Journal of the Neurological Sciences
- Vol. 323 (1-2) , 193-200
Objective characterization of the relative afferent pupillary defect in MS
- 1 December 2012
- Published by Elsevier in Journal of the Neurological Sciences
- Vol. 323 (1-2) , 193-200
Objective characterization of the relative afferent pupillary defect in MS