Hongsik Yoon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hongsik Yoon has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Taijin Min
9 shared publicationsGunhee Lee
6 shared publicationsAreum Kim
Department of Nano-Mechanics, Korea Institute of Machinery & Materials, Daejeon 34103, Republic of Korea
5 shared publicationsSeongBeom Jeon
5 shared publicationsSungil Lim
4 shared publicationsChanghak Lee
Department of Resources Recirculation Research, Korea Institute of Machinery & Materials, Daejeon 34103, Republic of Korea
3 shared publications
Latest Publications
- Open Access
- 16 March 2026
- Published by Korean Society of Environmental Engineering in Environmental Engineering Research
- Vol. 31 (5) , 260072
Membrane Capacitive Deionization with Barley Straw Biochar-Based Electrodes for Hardness Control
Recently, there have been increasing challenges in handling surplus biomass such as barley straw, and technologies that utilize these materials to create high value-added resources, such as electrode materials, are gaining considerable attention. In this study, a barley straw biochar-based activated carbon was synthesized from an agricultural by-product and evaluated for membrane capacitive deionization (MCDI). The electrochemical properties and hardness removal performance of the fabricated electrode were systematically investigated and compared with those of six commercial activated carbon electrodes. The biochar-based electrode exhibited a morphology comparable to commercial electrodes and showed typical electric double-layer capacitive behavior. The MCDI system achieved a deionization capacity of approximately 14 mg/g and a deionization rate of 0.035 mg/g/s. Although the deionization rate was slightly lower than that of some commercial electrodes, the biochar-based electrode demonstrated comparable deionization capacity and energy consumption (approximately 0.98 Wh/g-CaCl2). In addition, excellent cycling stability was observed, with 94.6% of the initial charge capacity retained after 180 cycles and Coulombic efficiency exceeding 99%. These results demonstrate that barley straw biochar-based activated carbon is an alternative to commercial activated carbon electrodes for CDI-based hardness control.
- 16 March 2026
- Published by Korean Society of Environmental Engineering in Environmental Engineering Research
- Vol. 31 (5) , 260072
Open AccessMembrane Capacitive Deionization with Barley Straw Biochar-Based Electrodes for Hardness Control
Recently, there have been increasing challenges in handling surplus biomass such as barley straw, and technologies that utilize these materials to create high value-added resources, such as electrode materials, are gaining considerable attention. In this study, a barley straw biochar-based activated carbon was synthesized from an agricultural by-product and evaluated for membrane capacitive deionization (MCDI). The electrochemical properties and hardness removal performance of the fabricated electrode were systematically investigated and compared with those of six commercial activated carbon electrodes. The biochar-based electrode exhibited a morphology comparable to commercial electrodes and showed typical electric double-layer capacitive behavior. The MCDI system achieved a deionization capacity of approximately 14 mg/g and a deionization rate of 0.035 mg/g/s. Although the deionization rate was slightly lower than that of some commercial electrodes, the biochar-based electrode demonstrated comparable deionization capacity and energy consumption (approximately 0.98 Wh/g-CaCl2). In addition, excellent cycling stability was observed, with 94.6% of the initial charge capacity retained after 180 cycles and Coulombic efficiency exceeding 99%. These results demonstrate that barley straw biochar-based activated carbon is an alternative to commercial activated carbon electrodes for CDI-based hardness control.
- Open Access
- 3 March 2026
- Published by Elsevier in Desalination and Water Treatment
- Vol. 325
Selective separation of ammonia from wastewater using a sweep gas-vacuum pressure hybrid type membrane degassing system
- 3 March 2026
- Published by Elsevier in Desalination and Water Treatment
- Vol. 325
Open AccessSelective separation of ammonia from wastewater using a sweep gas-vacuum pressure hybrid type membrane degassing system
- Open Access
- 23 February 2026
- Published by Elsevier in SSRN Electronic Journal
Potassium Separation from Mixed Monovalent Solutions Using Berlin Green-Based Hybrid Capacitive Deionization
Potassium supply is currently dominated by mining and is geographically concentrated, creating environmental and geopolitical vulnerabilities. These constraints have motivated potassium separation from diverse potassium-rich saline streams, including agricultural, industrial, and municipal wastewaters; desalination by-products such as bittern; and other concentrated brines. Accordingly, herein, we developed a hybrid capacitive deionization system using a Berlin-Green-type iron hexacyanoferrate (FeHCF) electrode synthesized by facile aqueous coprecipitation. This FeHCF electrode offered a Faradaic intercalation pathway beyond electric double-layer adsorption, as confirmed by rate-dependent electrochemical analyses. System performance was evaluated across Na+:K+ concentration ratios of 1:1–49:1, applied voltages from ±0.8 to ±1.2 V, and different operation-time windows. Under these conditions, the FeHCF-based HCDI system achieved a total Na++K+ deionization capacity of 0.380 ± 0.037 mmol g−1, approximately twice that of membrane CDI (MCDI; 0.189 ± 0.018 mmol g−1). Furthermore, HCDI increased charge efficiency (77.2 ±4.6%) relative to MCDI (55.6 ±3.7%) and reduced energy consumption (from 58.0 ± 4.0 (MCDI) to 41.8 ± 2.5 Wh mol−1). Together, these results establish the FeHCF-based HCDI system as an energy-efficient and composition-robust approach for potassium separation.
- 23 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPotassium Separation from Mixed Monovalent Solutions Using Berlin Green-Based Hybrid Capacitive Deionization
Potassium supply is currently dominated by mining and is geographically concentrated, creating environmental and geopolitical vulnerabilities. These constraints have motivated potassium separation from diverse potassium-rich saline streams, including agricultural, industrial, and municipal wastewaters; desalination by-products such as bittern; and other concentrated brines. Accordingly, herein, we developed a hybrid capacitive deionization system using a Berlin-Green-type iron hexacyanoferrate (FeHCF) electrode synthesized by facile aqueous coprecipitation. This FeHCF electrode offered a Faradaic intercalation pathway beyond electric double-layer adsorption, as confirmed by rate-dependent electrochemical analyses. System performance was evaluated across Na+:K+ concentration ratios of 1:1–49:1, applied voltages from ±0.8 to ±1.2 V, and different operation-time windows. Under these conditions, the FeHCF-based HCDI system achieved a total Na++K+ deionization capacity of 0.380 ± 0.037 mmol g−1, approximately twice that of membrane CDI (MCDI; 0.189 ± 0.018 mmol g−1). Furthermore, HCDI increased charge efficiency (77.2 ±4.6%) relative to MCDI (55.6 ±3.7%) and reduced energy consumption (from 58.0 ± 4.0 (MCDI) to 41.8 ± 2.5 Wh mol−1). Together, these results establish the FeHCF-based HCDI system as an energy-efficient and composition-robust approach for potassium separation.
- Open Access
- 6 November 2025
- Published by Elsevier in Water Research X
- Vol. 29
Effective removal and concentration of perfluoroalkyl substances (PFAS) using asymmetric membrane capacitive deionization with stop–flow operation
- 6 November 2025
- Published by Elsevier in Water Research X
- Vol. 29
Open AccessEffective removal and concentration of perfluoroalkyl substances (PFAS) using asymmetric membrane capacitive deionization with stop–flow operation
- Open Access
- 1 August 2025
- Published by Korean Society of Environmental Engineering in Journal of Korean Society of Environmental Engineers
- Vol. 47 (8) , 562-571
Investigation of Acid/Base Production and Energy Consumption in Redox-based Bipolar Electrodialysis for pH Control in Lithium Recovery
This study investigates the impact of key operating conditions on acid/base production and energy consumption in a redox-based bipolar membrane electrodialysis (redox-BMED) system, which enables chemical-free pH control for lithium recovery. A redox-BMED system utilizing a ferri/ferrocyanide redox couple was constructed, and the effects of applied voltage (0.6-1.2 V), cross-flow velocity (1.25-6.25cm/min), lithium feed concentration (250-2,500 mg-Li/L), and anion type (SO42- vs Cl-) were systematically examined. Acid and base production increased with higher voltages and higher cross-flow velocities, while energy consumption decreased under lower voltages and higher cross-flow velocities. Under optimal condition (1.2V, 6.25cm/min), acid/base production exceeded 260 μmole with minimal energy consumption of 44 Wh/mole. Cl- based electrolytes showed 29% higher productivity than SO42- based ones. Moreover, increasing the lithium concentration from 250 to 2,500mg-Li/L reduced energy consumption from 57 to 46 Wh/mole, confirming higher energy efficiency at higher concentrations. The system also maintained stable operation for over 120 hours without performance degradation, highlighting its scalability and durability. Overall, this study demonstrates the potential of redox-BMED as a sustainable and efficient electrochemical platform for pH control and high-purity lithium compound production in resource circulating recovery systems.
- 1 August 2025
- Published by Korean Society of Environmental Engineering in Journal of Korean Society of Environmental Engineers
- Vol. 47 (8) , 562-571
Open AccessInvestigation of Acid/Base Production and Energy Consumption in Redox-based Bipolar Electrodialysis for pH Control in Lithium Recovery
This study investigates the impact of key operating conditions on acid/base production and energy consumption in a redox-based bipolar membrane electrodialysis (redox-BMED) system, which enables chemical-free pH control for lithium recovery. A redox-BMED system utilizing a ferri/ferrocyanide redox couple was constructed, and the effects of applied voltage (0.6-1.2 V), cross-flow velocity (1.25-6.25cm/min), lithium feed concentration (250-2,500 mg-Li/L), and anion type (SO42- vs Cl-) were systematically examined. Acid and base production increased with higher voltages and higher cross-flow velocities, while energy consumption decreased under lower voltages and higher cross-flow velocities. Under optimal condition (1.2V, 6.25cm/min), acid/base production exceeded 260 μmole with minimal energy consumption of 44 Wh/mole. Cl- based electrolytes showed 29% higher productivity than SO42- based ones. Moreover, increasing the lithium concentration from 250 to 2,500mg-Li/L reduced energy consumption from 57 to 46 Wh/mole, confirming higher energy efficiency at higher concentrations. The system also maintained stable operation for over 120 hours without performance degradation, highlighting its scalability and durability. Overall, this study demonstrates the potential of redox-BMED as a sustainable and efficient electrochemical platform for pH control and high-purity lithium compound production in resource circulating recovery systems.
- 24 September 2024
- Published by Korean Society of Environmental Engineering in Environmental Engineering Research
- Vol. 30 (2) , 240436
Mercury emission and fate characteristics in various combustion sources
In this study, we investigated the behavior and emission characteristics of Hg across diverse industrial combustion sources, such as coal-fired power plants, solid refuse fuel (SRF) power plants, medical waste incinerators, and industrial waste incinerators, as well as the development of emission factors, Among the facilities, the estimated Hg control efficiency was 86% for coal-fired power plants, 69% for SRF power plants, and over 95% for medical and industrial waste incinerators. The oxidation and regulation of elemental Hg (Hg0) are considered important factors in reducing Hg air emissions, with the flue gas HCl concentration being the primary factor affecting Hg oxidation. Particulate Hg was mainly controlled in the electrostatic precipitator (ESP) at the power plant, effectively capturing dust particles ranging from 10 to 100 μm. The emission factors estimated by measuring stack flue gas exhibited their highest values at SRF power plants, with an estimated average of 127±25 mg/ton, while the lowest values were observed for industrial waste incinerators, with an average of 2.5±0.3 mg/ton. This study is significant in that it provides a comparative analysis of various real industrial cases, and the Hg emission factors are expected to offer valuable data for estimating future national Hg air emissions.
- 24 September 2024
- Published by Korean Society of Environmental Engineering in Environmental Engineering Research
- Vol. 30 (2) , 240436
Mercury emission and fate characteristics in various combustion sources
In this study, we investigated the behavior and emission characteristics of Hg across diverse industrial combustion sources, such as coal-fired power plants, solid refuse fuel (SRF) power plants, medical waste incinerators, and industrial waste incinerators, as well as the development of emission factors, Among the facilities, the estimated Hg control efficiency was 86% for coal-fired power plants, 69% for SRF power plants, and over 95% for medical and industrial waste incinerators. The oxidation and regulation of elemental Hg (Hg0) are considered important factors in reducing Hg air emissions, with the flue gas HCl concentration being the primary factor affecting Hg oxidation. Particulate Hg was mainly controlled in the electrostatic precipitator (ESP) at the power plant, effectively capturing dust particles ranging from 10 to 100 μm. The emission factors estimated by measuring stack flue gas exhibited their highest values at SRF power plants, with an estimated average of 127±25 mg/ton, while the lowest values were observed for industrial waste incinerators, with an average of 2.5±0.3 mg/ton. This study is significant in that it provides a comparative analysis of various real industrial cases, and the Hg emission factors are expected to offer valuable data for estimating future national Hg air emissions.
- Open Access
- 1 August 2024
- Published by Korean Society of Environmental Engineering in Journal of Korean Society of Environmental Engineers
- Vol. 46 (8) , 420-428
Investigation of the Deionization Rate of Asymmetric Capacitive Deionization Technology for the Treatment of Short-Chain Perfluoroalkyl Substances (PFAS)
Objectives : This study aims to introduce and evaluate the effectiveness of asymmetric membrane capacitive deionization (ACDI) in removing short-chain perfluoroalkyl substances (PFAS), specifically perfluorobutane sulfonic acid (PFBS), from aqueous solutions. This study offers important insights for the advancement of CDI technology in the sustainable treatment of industrial wastewater containing PFAS.Methods : ACDI was employed by removing the anion exchange membrane from conventional membrane capacitive deionization system. The effect of key operational parameters such as voltage (0.5~1.2 V), initial concentration (50~500 mg/L), and flow rate (1~5 ml/min) on PFBS removal efficiency was systematically investigated. Additionally, PFBS removal performance in the presence of chloride ions was also investigated to determine competing ion effects.Results and Discussion : The ACDI system significantly outperformed both CDI and MCDI, achieving a maximum deionization rate of 0.032 mg/g/s, compared to 0.012 mg/g/s for CDI and 0.01 mg/g/s for MCDI. Increasing the applied voltage from 0.5 V to 1.2 V enhanced the deionization rate, with the highest rate observed at 1.2 V. Higher initial PFBS concentrations also improved the deionization rate, increasing from 0.0009 mg/g/s at 50 mg/L to 0.032 mg/g/s at 500 mg/L. The optimal flow rate was found to be 2 ml/min, balancing ion contact time and throughput, resulting in the highest deionization rate. The presence of competing ions, such as chloride, reduced PFBS removal efficiency, as shown by the decrease in deionization rate when NaCl was added to the feed solution.Conclusion : Overall, the ACDI system demonstrated superior deionization capacity and energy efficiency for PFBS removal, highlighting its potential as a sustainable and efficient technology for treating water contaminated with short-chain PFAS. Future research should address the challenges posed by competing ions in real-world wastewater to further optimize the ACDI system’s performance.
- 1 August 2024
- Published by Korean Society of Environmental Engineering in Journal of Korean Society of Environmental Engineers
- Vol. 46 (8) , 420-428
Open AccessInvestigation of the Deionization Rate of Asymmetric Capacitive Deionization Technology for the Treatment of Short-Chain Perfluoroalkyl Substances (PFAS)
Objectives : This study aims to introduce and evaluate the effectiveness of asymmetric membrane capacitive deionization (ACDI) in removing short-chain perfluoroalkyl substances (PFAS), specifically perfluorobutane sulfonic acid (PFBS), from aqueous solutions. This study offers important insights for the advancement of CDI technology in the sustainable treatment of industrial wastewater containing PFAS.Methods : ACDI was employed by removing the anion exchange membrane from conventional membrane capacitive deionization system. The effect of key operational parameters such as voltage (0.5~1.2 V), initial concentration (50~500 mg/L), and flow rate (1~5 ml/min) on PFBS removal efficiency was systematically investigated. Additionally, PFBS removal performance in the presence of chloride ions was also investigated to determine competing ion effects.Results and Discussion : The ACDI system significantly outperformed both CDI and MCDI, achieving a maximum deionization rate of 0.032 mg/g/s, compared to 0.012 mg/g/s for CDI and 0.01 mg/g/s for MCDI. Increasing the applied voltage from 0.5 V to 1.2 V enhanced the deionization rate, with the highest rate observed at 1.2 V. Higher initial PFBS concentrations also improved the deionization rate, increasing from 0.0009 mg/g/s at 50 mg/L to 0.032 mg/g/s at 500 mg/L. The optimal flow rate was found to be 2 ml/min, balancing ion contact time and throughput, resulting in the highest deionization rate. The presence of competing ions, such as chloride, reduced PFBS removal efficiency, as shown by the decrease in deionization rate when NaCl was added to the feed solution.Conclusion : Overall, the ACDI system demonstrated superior deionization capacity and energy efficiency for PFBS removal, highlighting its potential as a sustainable and efficient technology for treating water contaminated with short-chain PFAS. Future research should address the challenges posed by competing ions in real-world wastewater to further optimize the ACDI system’s performance.
- 6 June 2024
- Published by Korean Society of Environmental Engineering in Environmental Engineering Research
- Vol. 30 (1) , 240253
CO2 microbubbling system for lithium carbonate precipitation
Lithium carbonate (Li2CO3) is becoming increasingly valuable with the growth of the lithium-ion battery industry. For effective Li2CO3 production, the efficient supply of the carbonate source to the solution is crucial. Conventionally, sodium carbonate has been used as the carbonate source; however, the importance of CO2 utilization has been recently recognized. Conventional CO2-based carbonate sourcing exhibits limited efficiency. In this study, we propose a CO2 microbubbling system based on a rotating nozzle for Li2CO3 precipitation. The CO2 micro-bubbling system demonstrated a 1.6 to 1.9 times greater precipitation reaction rate than that of the conventional CO2 bubbling system. This rate enhancement could be attributed to the increased gas-liquid contact surface and greater residence time due to the generation of CO2 microbubbles. Additionally, the Li2CO3 reaction terminated when the pH of the solution dropped below 9.4–9.7 approximately. The re-dissolution of precipitated Li2CO3 occurred below this pH range as bicarbonate ions became the dominant species over carbonate ions. This study successfully demonstrated that CO2 microbubbling technology could be an excellent alternative for carbonate sourcing systems in the Li2CO3 production industry.
- 6 June 2024
- Published by Korean Society of Environmental Engineering in Environmental Engineering Research
- Vol. 30 (1) , 240253
CO2 microbubbling system for lithium carbonate precipitation
Lithium carbonate (Li2CO3) is becoming increasingly valuable with the growth of the lithium-ion battery industry. For effective Li2CO3 production, the efficient supply of the carbonate source to the solution is crucial. Conventionally, sodium carbonate has been used as the carbonate source; however, the importance of CO2 utilization has been recently recognized. Conventional CO2-based carbonate sourcing exhibits limited efficiency. In this study, we propose a CO2 microbubbling system based on a rotating nozzle for Li2CO3 precipitation. The CO2 micro-bubbling system demonstrated a 1.6 to 1.9 times greater precipitation reaction rate than that of the conventional CO2 bubbling system. This rate enhancement could be attributed to the increased gas-liquid contact surface and greater residence time due to the generation of CO2 microbubbles. Additionally, the Li2CO3 reaction terminated when the pH of the solution dropped below 9.4–9.7 approximately. The re-dissolution of precipitated Li2CO3 occurred below this pH range as bicarbonate ions became the dominant species over carbonate ions. This study successfully demonstrated that CO2 microbubbling technology could be an excellent alternative for carbonate sourcing systems in the Li2CO3 production industry.
- Open Access
- 27 April 2024
- Published by Elsevier in Separation and Purification Technology
- Vol. 348
Efficient removal of short-chain perfluoroalkyl substances (PFAS) using asymmetric membrane capacitive deionization
- 27 April 2024
- Published by Elsevier in Separation and Purification Technology
- Vol. 348
Open AccessEfficient removal of short-chain perfluoroalkyl substances (PFAS) using asymmetric membrane capacitive deionization
- Open Access
- 26 October 2023
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 13 (45) , 31480-31486
Effect of activated carbon electrode material characteristics on hardness control performance of membrane capacitive deionization
This study provides a systematic analysis of electrode material characteristics in membrane capacitive deionization (MCDI) for hardness control, offering valuable insights for selecting optimal materials and enhancing water treatment processes.
- 26 October 2023
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 13 (45) , 31480-31486
Open AccessEffect of activated carbon electrode material characteristics on hardness control performance of membrane capacitive deionization
This study provides a systematic analysis of electrode material characteristics in membrane capacitive deionization (MCDI) for hardness control, offering valuable insights for selecting optimal materials and enhancing water treatment processes.