DRDavid Rot

David Rot

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


David Rot has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Jakub Jirinec

    Department of Electrical Power Engineering and Environmental Engineering, University of West Bohemia, Pilsen, Czech Republic

    5 shared publications
  • Stanislav Jirinec

    Regional Scientific Research Centre, University of West Bohemia, Pilsen, Czech Republic

    4 shared publications
  • Jiri Kozeny

    Department of Electrical Power Engineering and Environmental Engineering, University of West Bohemia, Pilsen, Czech Republic

    3 shared publications
  • Antonin Podhrazky

    Regional Scientific Research Centre, University of West Bohemia, Pilsen, Czech Republic

    2 shared publications
  • Igor Poznyak

    Department of Electrotechnology, Saint-Petersburg Electrotechnical University "LETI", St. Petersburg, Russia

    2 shared publications
  • J. Kozeny

    Department of Electrical Power Engineering and Environmental Engineering, University of West Bohemia Pilsen, Czech Republic

    2 shared publications

Latest Publications

  • Development of Hardening Machine and Intelligent Control

    by Michal Knedlik, David Rot

    This article focuses on introducing the developed hardening machine based on induction heating. This machine differs significantly from conventional solutions mainly due to its extensive measuring system, which gives us a complete overview of what is happening during the process. Furthermore, the developed control system using PLC is described. This paper also mentions the design of own control of the frequency converter using microcontrollers.

  • Manipulation System for Measuring Heat Flux in Radioactive Melt

    by Michal Knedlík, David Rot, Jan Hrbek

    This article is focused on introducing of the manipulation system, which is used to insert equipment or measuring probes into the chamber of a cold crucible during experimental induction skull melting. The measuring probe could be, e.g., calorimeter for measuring heat flux from a melt, which is created in the cold crucible by electromagnetic induction. The first part describes the technical parameters of the manipulator and the possibilities of manipulator controlling. The manipulation system is controlled by the algorithm implemented in the programmable logic controller CompactRIO or by mechanical controller called manual pulse generator, which is independent of the programmable logic controller. Different control methods increase the safety of the system. The next part contents basic information about the control algorithm based on LabVIEW software and the user interface of the touch screen. The article also deals with testing the manipulator, which was used in an experiment simulating corium behavior under conditions of the severe accident of a nuclear power plant. The last part describes simulations of electromagnetic field and temperature field in the chamber of the cold crucible, which were confirmed with real measuring. The goal of the simulations was to determine the effect on the manipulation system and calculation of Joule's losses in the calorimeter before immersion into the melt. The most significant heat transfer to the calorimeter was the radiation from a melt, which was also calculated.

  • Distortion in Induction-Hardened Cylindrical Part

    by Jiří Hájek, David Rot, Jakub Jiřinec

    This article concerns distortion of a workpiece after induction-hardening under various conditions. It focuses particularly on the effects of quenching water temperature, PAG polymer concentration and the rotation speed of the workpiece during induction hardening. Electrical as well as non-electrical quantities which affect the process were monitored. They included the current passing through the inductor, the power frequency, quenching water temperature, the flow rate of the quenchant through the spray-quench device, the speed of rotation of the workpiece and some others. The workpiece was a cylinder 70 mm in length which contained a drilled off-axis through hole. Prior to hardening, dimensions of the workpiece and the hole were measured on three planes set in different distances from the bottom face. The measurement was repeated after induction hardening and the findings are reported in this article. Post-process hardness was measured on the cylindrical surface of the workpiece. Hardening depths obtained with different quenchants were measured.


  • The Energy Efficient Solution for Intelligent Lighting

    by Jakub Jirinec, David Rot, Raytcho Velev

    The aim of this article is to introduce the intelligent lighting control system. The created control system is able to diagnose current conditions and control the lighting system operatively to achieve the required lighting standard at minimal energy costs. The developed system will thus further reduce the energy consumption of the buildings in which it will be applied. The system was created in cooperation with Südluft Systemtechnik and will serve primarily for lighting control of commercial kitchens.


  • Preliminary Experiments While Designing a Cold Crucible for Metal Melting

    by David Rot, Jakub Jiřinec

    This article deals with issues arising during the design and production of a cold crucible (CC) for melting metals and alloys using electromagnetic induction. The article deals particularly with the results from tests and numerical simulations for designing the CC. The heat fluxes from different metals and their alloys to two different CCs and one calorimeter were measured during the tests. The required magnetohydrodynamic effects on the melted load were verified, and related (independent) electrical and thermal quantities were measured. The dependent electric parameters (R, L, Z) were measured on the inductor and on the primary side of the high frequency transformer. The experiments were numerically simulated first, and the experimental and simulated results were then compared. The final part of the article contains the final design of the CC. The final CC was tested for the transfer of energy from the inductor into a load placed inside the CC and the required magnetohydrodynamic effects on the melted load inside the CC were partly verified too.


  • Measuring System for Recuperation Units

    by Jakub Jiřinec, David Rot

    The article is primarily concerned with the measurement of heat recovery units for different work environments. At present, great emphasis is placed on indoor air quality. The quality of the indoor environment greatly influences the concentration, response, and overall quality of work. This is important in the area of the main control room of the nuclear power plant. For efficient suction of these spaces, it is necessary to handle the entire control process so that the air is delivered to the desired location in proper quantity and quality. For this reason, it is necessary to know the properties of the used components (e.g., recuperator). To calculate the efficiency of heat recovery unit, it is necessary to measure temperature, humidity, and air volume in its individual parts. Based on these requirements, a measurement system was created to achieve the appropriate data for the further optimization process. The first part briefly describes the created measuring system primarily tested on SL-Thermo (Plattling, Germany) units produced by the Südluft Systemtechnik (Plattling, Germany). The core of the system is based on an industrial programmable logic controller (PLC) in combination with LabVIEW (Austin, TX) software. The software can be used in laboratory condition or in the real operation. The next part is devoted to measurement of the heat recovery unit in laboratory condition, where the different operating states of the heat recovery unit were simulated. On the basis of the measurements made, a final evaluation was made and some structural modifications were recommended, which would increase the efficiency of the regenerative unit.


  • Induction system for hardening of small parts

    by David Rot, Jakub Jirinec, Jiri Kozeny, Antonin Podhrazky, Jiri Hajek, Stanislav Jirinec

    This article deals with the process of the induction hardening of a small machine part. We have cooperated on the design and production of a compact induction system for hardening of small machine parts with the company PEARTEC which develops and produces their own induction converters. The whole process included the production of a frequency convertor, a transformer, an inductor, the compact construction of a machine with an integrated cooling circuit for the cooling of the induction system, a cooling circuit with the hardening liquid for the hardening of machine parts including the collecting vessel, a feeder (feeding mechanism) for the machine parts and the distributor (distribution board) of the machine. The whole induction hardening system was optimized and the hardened machine parts were put to tests of hardness, the microscopic control of the hardened surface and a chemical material analysis of the machine part. The demanded functionality of the whole induction hardening system was verified in this way.


  • The parameters measurement of heat recovery units

    by Jakub Jirinec, David Rot

    The article deals with the issue of heat recovery units (especially waste-heat recovery of industrial kitchens) and measuring system used to verify the parameters declared by manufacturer. The first part briefly describes the introduction to the given issue. The next part is devoted to the own measuring system (design, program and its own implementation). Measurements are made on the new SL-Thermo recuperation unit to verify the correct operation of the measuring system.

  • Induction melting of aluminium oxide in the cold crucible

    by David Rot, Jiri Kozeny, Stanislav Jirinec, Jakub Jirinec, Antonin Podhrazky, Igor Poznyak

    This article deals with the process of the experimental induction melting of aluminium oxide in so called cold crucible (CC). The experiment took place in a couple of steps, that were needed for a successful realisation of the melting. The first step was the designing of suitable parameters of the cold crucible regarding the depth of penetration of the eddy currents into the melted aluminium oxide and the output power of the high frequency generator for melting in the cold crucible. The process of the experiment itself then consisted in the preparation of cold crucible for melting. The overheating of the starting material to the melting point of the load. The melting of the load. The endurance of the load in steady-state at a constant temperature. The controlled cooling of the load. The removal of the ingot of aluminium oxide from the cold crucible. The article is dedicated to the process of the experiment with respect to the development of the heating losses considering the input power during the melting process in the whole induction system.


  • Advanced measurements for analysis and data acquisition from the cold crucible

    by David Rot, Jakub Jirinec, Stanislav Jirinec, Jiri Kozeny

    The main task of this paper is to introduce the created measuring system which is used for analysis and data acquisition of measuring devices and sub-sensors installed on an experimental cold crucible. The motivation for creating a measuring system was need to accurately monitor and measure the behavior of the individual components of the cold crucible. Another reason for the development of measuring system was verification of numerical models which we focused on in previous years when we did not have appropriate equipment. The detailed description and results of numerical simulations were published in the article [1], [2]. Knowledge and core of measuring system creating in LabView software will be also used for measuring and data acquisition of the other induction devices in our laboratory.