Mehmet Nuri Almali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mehmet Nuri Almali has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- İsHak Parlar
Yuzuncu Yil Universitesi
8 shared publications - Ali Can Çabuker
Department of Electrical-Electronics Engineering, Faculty of Engineering, Van Yuzuncu Yil University, Van 65000, Türkiye
5 shared publications - Atilla Bayram
Mechanical Engineering Department, Yüzüncü Yıl University, Van, Turkey
1 shared publication - Emre Biçek
Van Yuzuncu Yil Universitesi
1 shared publication - Firas Muhammad Al-Naqshbandi
Erbil Polytech Univ, Bldg & Construct Dept, Erbil, Iraq
1 shared publication - Hasan Hataş
Van Yuzuncu Yil Universitesi
1 shared publication
Latest Publications
- Open Access
- 19 August 2024
- Published by MDPI AG in Electronics
- Vol. 13 (16) , 3291
Metaheuristic Algorithm-Based Proportional–Integrative–Derivative Control of a Twin Rotor Multi Input Multi Output System
Metaheuristic algorithms are computational techniques based on the collective behavior of swarms and the study of organisms acting in communities. These algorithms involve different types of organisms. Finding controller values for nonlinear systems is a challenging task using classical approaches. Hence, using metaheuristics to find the controller values of a twin rotor multi-input multi-output system (TRMS), one of the nonlinear systems studied in the literature, seems to be more appropriate than using classical methods. In this study, different types of metaheuristic algorithms were used to find the PID controller values for a TRMS, including a genetic algorithm (GA), a dragonfly algorithm, a cuckoo algorithm, a particle swarm optimization (PSO) algorithm, and a coronavirus optimization algorithm (COVIDOA). The obtained graphs were analyzed based on certain criteria for the main rotor and tail rotor angles to reach the reference value in the TRMS. The experimental results show that when the rise and settlement times of the TRMS are compared in terms of performance, the GA took 1.5040 s (seconds) and the COVIDOA took 9.59 s to increase the pitch angle to the reference value, with the GA taking 0.7845 s and the COVIDOA taking 2.4950 s to increase the yaw angle to the reference value. For the settling time, the GA took 11.67 s and the COVIDOA took 28.01 s for the pitch angle, while the GA took 14.97 s and the COVIDOA took 26.69 s for the yaw angle. With these values, the GA and COVIDOA emerge as the foremost algorithms in this context.
- 19 August 2024
- Published by MDPI AG in Electronics
- Vol. 13 (16) , 3291
Open AccessMetaheuristic Algorithm-Based Proportional–Integrative–Derivative Control of a Twin Rotor Multi Input Multi Output System
Metaheuristic algorithms are computational techniques based on the collective behavior of swarms and the study of organisms acting in communities. These algorithms involve different types of organisms. Finding controller values for nonlinear systems is a challenging task using classical approaches. Hence, using metaheuristics to find the controller values of a twin rotor multi-input multi-output system (TRMS), one of the nonlinear systems studied in the literature, seems to be more appropriate than using classical methods. In this study, different types of metaheuristic algorithms were used to find the PID controller values for a TRMS, including a genetic algorithm (GA), a dragonfly algorithm, a cuckoo algorithm, a particle swarm optimization (PSO) algorithm, and a coronavirus optimization algorithm (COVIDOA). The obtained graphs were analyzed based on certain criteria for the main rotor and tail rotor angles to reach the reference value in the TRMS. The experimental results show that when the rise and settlement times of the TRMS are compared in terms of performance, the GA took 1.5040 s (seconds) and the COVIDOA took 9.59 s to increase the pitch angle to the reference value, with the GA taking 0.7845 s and the COVIDOA taking 2.4950 s to increase the yaw angle to the reference value. For the settling time, the GA took 11.67 s and the COVIDOA took 28.01 s for the pitch angle, while the GA took 14.97 s and the COVIDOA took 26.69 s for the yaw angle. With these values, the GA and COVIDOA emerge as the foremost algorithms in this context.
- Open Access
- 20 May 2024
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 39 (3) , 1963-1972
Memristör taklit devresi kullanılarak yeni bir işlemsel yükselteç modeli ve faz kaydırmalı osilatör devresine uygulanması
Bu çalışmada, geleneksel işlemsel yükselteç (741 ailesi) devre elemanının iç yapısı doğrusal TiO2 sürüklenme hızlı memristör (DTSHM) emulatör modeli ile yeniden tasarlanarak yeni bir op-amp modeli oluşturulmuştur. Önerilen bu op-amp modelinin optimize edilmiş çalışma koşulları ve durumları yeniden belirlendi. RC osilatörlerinden biri olan faz kaydırmalı osilatör (FKO) devresinde yükseltici eleman olarak memristor tabanlı op-amp modeli kullanılmıştır. Önerilen yeni FKO ile salınım başlama zamanı, yerleşme zamanı, hızlı fourier dönüşümü (FFT) analizi ve bunların çıkış parametreleri üzerindeki etkileri hem deneysel hem de simüle edilmiştir. Bu çalışmada önerilen yeni osilatör modeli, sadece orta frekans bölgesinde değil, aynı zamanda düşük ve yüksek frekans bölgelerinde de detaylı olarak değerlendirilmektedir. Ayrıca bu devrelerin verimliliği uygulama devreleri ile entegre edilmiş ve önerilen op-amp modelinin doğruluğu ve uygulanabilirliği teorik olarak kapsamlı bir şekilde çalışılmış ve deneysel ve simülasyon sonuçları ile desteklenmiştir. Son olarak önerilen op-amp modeli ile gerçekleştirilen osilatör devrelerinin hem simülasyonu hem de deneysel sonuçları tablolar halinde detaylı olarak sunulmuştur.
- 20 May 2024
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 39 (3) , 1963-1972
Open AccessMemristör taklit devresi kullanılarak yeni bir işlemsel yükselteç modeli ve faz kaydırmalı osilatör devresine uygulanması
Bu çalışmada, geleneksel işlemsel yükselteç (741 ailesi) devre elemanının iç yapısı doğrusal TiO2 sürüklenme hızlı memristör (DTSHM) emulatör modeli ile yeniden tasarlanarak yeni bir op-amp modeli oluşturulmuştur. Önerilen bu op-amp modelinin optimize edilmiş çalışma koşulları ve durumları yeniden belirlendi. RC osilatörlerinden biri olan faz kaydırmalı osilatör (FKO) devresinde yükseltici eleman olarak memristor tabanlı op-amp modeli kullanılmıştır. Önerilen yeni FKO ile salınım başlama zamanı, yerleşme zamanı, hızlı fourier dönüşümü (FFT) analizi ve bunların çıkış parametreleri üzerindeki etkileri hem deneysel hem de simüle edilmiştir. Bu çalışmada önerilen yeni osilatör modeli, sadece orta frekans bölgesinde değil, aynı zamanda düşük ve yüksek frekans bölgelerinde de detaylı olarak değerlendirilmektedir. Ayrıca bu devrelerin verimliliği uygulama devreleri ile entegre edilmiş ve önerilen op-amp modelinin doğruluğu ve uygulanabilirliği teorik olarak kapsamlı bir şekilde çalışılmış ve deneysel ve simülasyon sonuçları ile desteklenmiştir. Son olarak önerilen op-amp modeli ile gerçekleştirilen osilatör devrelerinin hem simülasyonu hem de deneysel sonuçları tablolar halinde detaylı olarak sunulmuştur.
- 20 February 2024
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (7) , 4169-4180
Design of Hybrid Switched Diode Multilevel Inverter Using Single DC Source
- 20 February 2024
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (7) , 4169-4180
Design of Hybrid Switched Diode Multilevel Inverter Using Single DC Source
- Open Access
- 9 December 2023
- Published by MDPI AG in Electronics
- Vol. 12 (24) , 4946
A High-Efficiency Single-Stage Isolated Sepic-Flyback AC–DC Led Driver
Regulating LED current and voltage is critical to maintaining a constant luminous flux in AC- or DC-powered LED lighting circuits. Today, users require constant current drivers that can provide a wide range of output voltages to drive different numbers of series-connected LED arrays. This work proposes an LED driver by combining an isolated SEPIC converter operating in the continuous conduction mode (CCM) and a modified Vienna rectifier. The proposed LED driver offers a single-switch control structure by adding a Vienna rectifier to the integrated SEPIC-FLYBACK converter. This driver structure provides many advantages over traditional bridge rectifier structures. The prototype circuit was tested in an 18 W continuous current mode (CCM) to verify its feasibility. As a result of the values obtained from both simulation and prototype circuit models, it has been shown to provide many of the following advantages: 95% high efficiency, high reliability, 4% low total harmonic distortion, 97% high power factor, and 70 V low switching voltage. This work meets class C 3-2 and IEC 61000 standards.
- 9 December 2023
- Published by MDPI AG in Electronics
- Vol. 12 (24) , 4946
Open AccessA High-Efficiency Single-Stage Isolated Sepic-Flyback AC–DC Led Driver
Regulating LED current and voltage is critical to maintaining a constant luminous flux in AC- or DC-powered LED lighting circuits. Today, users require constant current drivers that can provide a wide range of output voltages to drive different numbers of series-connected LED arrays. This work proposes an LED driver by combining an isolated SEPIC converter operating in the continuous conduction mode (CCM) and a modified Vienna rectifier. The proposed LED driver offers a single-switch control structure by adding a Vienna rectifier to the integrated SEPIC-FLYBACK converter. This driver structure provides many advantages over traditional bridge rectifier structures. The prototype circuit was tested in an 18 W continuous current mode (CCM) to verify its feasibility. As a result of the values obtained from both simulation and prototype circuit models, it has been shown to provide many of the following advantages: 95% high efficiency, high reliability, 4% low total harmonic distortion, 97% high power factor, and 70 V low switching voltage. This work meets class C 3-2 and IEC 61000 standards.
- 30 April 2023
- Published by Van Yuzuncu Yil University in Yüzüncü Yıl Üniversitesi Fen Bilimleri Enstitüsü Dergisi
- Vol. 28 (1) , 60-75
Tek Bir Kanaldan Kaotik Maskelenmiş Ses Sinyalinin İletilmesi
Data security is very crucial for communication systems. Encryption methods are frequently used to ensure security. Chaotic oscillators are used for the encryption of data because they produce signals that do not repeat themselves. Identical chaotic oscillators should be used and synchronized with each other in order to perform encryption and decryption processes healthily. In this study, the encrypted data and synchronization signal are transmitted to the receiver side using the frequency division multiplexing (FDM) method to realize the synchronization between two chaotic oscillators. High-frequency keying is used to increase the encryption quality of the signal to be encrypted on the transmitter side. Proportional-Integral-Derivative (PID) control is used to provide synchronization between two chaotic oscillators. The correlation test, peak signal to noise ratio (PSNR), mean square error (MSE) and spectral entropy were used to determine the accuracy relationship between the original signal and the decryption signal. As a result, simulation programs and numerical analysis verified the encryption success and reliability of the created system.
- 30 April 2023
- Published by Van Yuzuncu Yil University in Yüzüncü Yıl Üniversitesi Fen Bilimleri Enstitüsü Dergisi
- Vol. 28 (1) , 60-75
Tek Bir Kanaldan Kaotik Maskelenmiş Ses Sinyalinin İletilmesi
Data security is very crucial for communication systems. Encryption methods are frequently used to ensure security. Chaotic oscillators are used for the encryption of data because they produce signals that do not repeat themselves. Identical chaotic oscillators should be used and synchronized with each other in order to perform encryption and decryption processes healthily. In this study, the encrypted data and synchronization signal are transmitted to the receiver side using the frequency division multiplexing (FDM) method to realize the synchronization between two chaotic oscillators. High-frequency keying is used to increase the encryption quality of the signal to be encrypted on the transmitter side. Proportional-Integral-Derivative (PID) control is used to provide synchronization between two chaotic oscillators. The correlation test, peak signal to noise ratio (PSNR), mean square error (MSE) and spectral entropy were used to determine the accuracy relationship between the original signal and the decryption signal. As a result, simulation programs and numerical analysis verified the encryption success and reliability of the created system.
- Open Access
- 29 March 2023
- Published by Kütahya Dumlupinar Üniversitesi in Journal of Scientific Reports-A
- No. 052,p. 174-189
EVALUATION OF CONTROLLER PARAMETERS ON THE TWIN ROTOR MULTIPLE INPUT MULTIPLE OUTPUT SYSTEM USING BUTTERFLY-BASED PARTICLE SWARM OPTIMIZATION
Studies on the control of nonlinear systems with metaheuristic algorithms are increasing day by day. It is one of the nonlinear systems in the Twin rotor multiple input multiple output (TRMS) system, which emerged as a prototype of helicopters. This system has two control angles horizontally and vertically. In this study, the yaw and pitch angle control parameters of the TRMS system were found using both traditional and butterfly-based particle swarm optimization (BFPSO) method. In experimental studies, reference values of main propeller and tail propeller angles were tried to be reached in TRMS with fractional order proportional-integral-derivative (FOPID), proportional-integral-derivative (PID) and tilt-integral-derivative (TID) controllers.
- 29 March 2023
- Published by Kütahya Dumlupinar Üniversitesi in Journal of Scientific Reports-A
- No. 052,p. 174-189
Open AccessEVALUATION OF CONTROLLER PARAMETERS ON THE TWIN ROTOR MULTIPLE INPUT MULTIPLE OUTPUT SYSTEM USING BUTTERFLY-BASED PARTICLE SWARM OPTIMIZATION
Studies on the control of nonlinear systems with metaheuristic algorithms are increasing day by day. It is one of the nonlinear systems in the Twin rotor multiple input multiple output (TRMS) system, which emerged as a prototype of helicopters. This system has two control angles horizontally and vertically. In this study, the yaw and pitch angle control parameters of the TRMS system were found using both traditional and butterfly-based particle swarm optimization (BFPSO) method. In experimental studies, reference values of main propeller and tail propeller angles were tried to be reached in TRMS with fractional order proportional-integral-derivative (FOPID), proportional-integral-derivative (PID) and tilt-integral-derivative (TID) controllers.
- 3 August 2022
- Published by Springer Nature in Journal of Electronic Testing
- Vol. 38 (4) , 445-452
Experimental and Simulation Results of Wien Bridge Oscillator Circuıt Realized wıth Op-Amp Designed Using a Memristor
- 3 August 2022
- Published by Springer Nature in Journal of Electronic Testing
- Vol. 38 (4) , 445-452
Experimental and Simulation Results of Wien Bridge Oscillator Circuıt Realized wıth Op-Amp Designed Using a Memristor
- 4 July 2022
- Published by Springer Nature in Iranian Journal of Science and Technology, Transactions of Electrical Engineering
- Vol. 46 (4) , 913-923
Transmission and Decryption of the Audio Signal Masked with ECG by FDM Method
Today, the use of these methods as hybrids has provided the motivation to be a solution to important problems, since the existing methods are insufficient at some points in ensuring the security of personal data. In data security, the inability to decrypt and decrypt the signal to be encrypted retrospectively has always been the subject of research in terms of privacy. At this point, it was preferred to use the electrocardiography (ECG) signal, which is a signal that shows the vital signs of the human body and is also difficult to copy. In the study, firstly, the emulator circuit was obtained by using the mathematical model of the ECG signal. With this obtained signal, the audio signals are masked. The audio signal masked on the transmitter side and the signals providing synchronization were transmitted to the receiver side over a single channel using the frequency division multiplexing (FDM) method. Then, the sliding mode control (SMC) method was chosen for the synchronization of the ECG emulator circuits on the receiver and transmitter side. Histogram, spectral, mean square error (MSE), peak signal to noise ratio (PSNR), key space and key sensitivity, NSCR (number of sample change rate), UACI (unified average changing intensity) and PESQ (perceptual evaluation of speech quality) analyses were used to check the accuracy of the system. These analyses showed that the ECG encoding method has faster unit change, reduces synchronization time, minimizes losses and improves the security of the masked signal compared to other methods sent from two channels. Finally, use of an arrhythmia ECG signal for the synchronization signal on both the transmitter and receiver sides, the synchronization of this signal with the SMC method and the testing of a live audio recording in addition to the conversation, distinguishes the study from other existing studies and reveals its originality.
- 4 July 2022
- Published by Springer Nature in Iranian Journal of Science and Technology, Transactions of Electrical Engineering
- Vol. 46 (4) , 913-923
Transmission and Decryption of the Audio Signal Masked with ECG by FDM Method
Today, the use of these methods as hybrids has provided the motivation to be a solution to important problems, since the existing methods are insufficient at some points in ensuring the security of personal data. In data security, the inability to decrypt and decrypt the signal to be encrypted retrospectively has always been the subject of research in terms of privacy. At this point, it was preferred to use the electrocardiography (ECG) signal, which is a signal that shows the vital signs of the human body and is also difficult to copy. In the study, firstly, the emulator circuit was obtained by using the mathematical model of the ECG signal. With this obtained signal, the audio signals are masked. The audio signal masked on the transmitter side and the signals providing synchronization were transmitted to the receiver side over a single channel using the frequency division multiplexing (FDM) method. Then, the sliding mode control (SMC) method was chosen for the synchronization of the ECG emulator circuits on the receiver and transmitter side. Histogram, spectral, mean square error (MSE), peak signal to noise ratio (PSNR), key space and key sensitivity, NSCR (number of sample change rate), UACI (unified average changing intensity) and PESQ (perceptual evaluation of speech quality) analyses were used to check the accuracy of the system. These analyses showed that the ECG encoding method has faster unit change, reduces synchronization time, minimizes losses and improves the security of the masked signal compared to other methods sent from two channels. Finally, use of an arrhythmia ECG signal for the synchronization signal on both the transmitter and receiver sides, the synchronization of this signal with the SMC method and the testing of a live audio recording in addition to the conversation, distinguishes the study from other existing studies and reveals its originality.
- 21 June 2022
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 38 (1) , 605-616
Control of 2-Dof TRMS MIMO system using FOPID & FOSTSMC method
Helikoptere benzeyen ikinci dereceden ikiz pervaneli çoklu girişli ve çoklu çıkışlı (MIMO) doğrusal olmayan bir sistemin (TRMS) kontrol tasarımı çok karmaşık bir iştir. TRMS sistemi, bir kiriş ile birbirlerine bağlantılı olan ana ve kuyruk pervanesinde oluşmaktadır. TRMS sisteminin dengesinin sağlanması için her iki pervane açıları, pervanelerin bağlı bulunduğu DC motorların hızları değiştirilerek yapılır. TRMS sisteminin dengede çalışması sağlamak amacıyla oransal-integral-türev (PID), kesir dereceli PID (FOPID), kayan kip (SMC), Süper bükümlü kayan kip (STSMC) ve Kesirli dereceli süper bükümlü kayan kip (FOSTSMC) kontrol yöntemleri kullanılmıştır. Kontrol parametrelerinin belirlenmesi için MATLAB/Simulink programında benzetim çalışmaları yapılmıştır. Benzetim çalışmalarında bulunan en başarılı yöntemler kullanılarak, deneysel çalışmalar yapılmıştır. Benzetim ve deneysel çalışmalarının her ikisinde de ana pervane FOPID ve kuyruk pervanesi FOSTSMC yöntemi ile kontrolü diğer kontrol yöntemlerine göre en iyi sonucu verdiği görülmüştür.
- 21 June 2022
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 38 (1) , 605-616
Control of 2-Dof TRMS MIMO system using FOPID & FOSTSMC method
Helikoptere benzeyen ikinci dereceden ikiz pervaneli çoklu girişli ve çoklu çıkışlı (MIMO) doğrusal olmayan bir sistemin (TRMS) kontrol tasarımı çok karmaşık bir iştir. TRMS sistemi, bir kiriş ile birbirlerine bağlantılı olan ana ve kuyruk pervanesinde oluşmaktadır. TRMS sisteminin dengesinin sağlanması için her iki pervane açıları, pervanelerin bağlı bulunduğu DC motorların hızları değiştirilerek yapılır. TRMS sisteminin dengede çalışması sağlamak amacıyla oransal-integral-türev (PID), kesir dereceli PID (FOPID), kayan kip (SMC), Süper bükümlü kayan kip (STSMC) ve Kesirli dereceli süper bükümlü kayan kip (FOSTSMC) kontrol yöntemleri kullanılmıştır. Kontrol parametrelerinin belirlenmesi için MATLAB/Simulink programında benzetim çalışmaları yapılmıştır. Benzetim çalışmalarında bulunan en başarılı yöntemler kullanılarak, deneysel çalışmalar yapılmıştır. Benzetim ve deneysel çalışmalarının her ikisinde de ana pervane FOPID ve kuyruk pervanesi FOSTSMC yöntemi ile kontrolü diğer kontrol yöntemlerine göre en iyi sonucu verdiği görülmüştür.
- 21 June 2022
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 38 (1) , 345-356
Bir insansız kara aracının model öngörü kontrol metodu ile GPS tabanlı yol takibi
Bu makalede prototip tasarımı yapılmış olan bir insansız kara aracının yol takip kontrolü konum ve yönelim hata geri beslemesine dayalı olarak sunulmuştur. Bu otonom aracın konum ve yönelimini doğru bir şekilde tanımlamak için aracın ölçme ünitesi gerçek zamanlı küresel yer belirleme sistemi (RTK-GPS), ataletsel ölçme ünitesi (IMU) ve mutlak enkoder sensörlerini içermektedir. Mobil robotun yörünge takibi için ardışık olarak doğrusallaştırılmış ve ayrıklaştırılmış kinematik bir modele dayalı model öngörülü kontrol kullanılmıştır. Bu optimal kontrol metodu verilen bir yol referansı üzerinde hatasız bir şekilde hareket ettiği kabul edilen holonomik olmayan sanal bir araca göre oluşan en küçük konum ve yönel hatalarına ek olarak en düzgün direksiyon açısının elde edilmesi üzerine işlevini gerçekleştirmektedir. Burada takip edilen yollar bir sayısal haritalama programından elde edilen kontrol noktaları ile oluşturulan rasyonel temelli eğriler (spline) veya bilindik geometrik eğriler ile tanımlanmaktadır. Bu makale hem benzetim hem de gerçek zamanlı deneysel test çalışmalarını içermektedir. Elde edilen sonuçlar aracın tasarım performansı ve kontrol stratejisi yönünden irdelenmiştir. Gerçek araç prototipi üzerindeki fiziksel sınırlandırmalara rağmen konum ve yönelim hatalarının makul sınırlar içerisinde oluştuğu gözlemlenmiştir. Özellikle direksiyon açısının aşırı bir salınıma maruz kalmaması kullanılan kontrol metodunun iyi bir performans gösterdiğini ifade etmektedir.
- 21 June 2022
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 38 (1) , 345-356
Bir insansız kara aracının model öngörü kontrol metodu ile GPS tabanlı yol takibi
Bu makalede prototip tasarımı yapılmış olan bir insansız kara aracının yol takip kontrolü konum ve yönelim hata geri beslemesine dayalı olarak sunulmuştur. Bu otonom aracın konum ve yönelimini doğru bir şekilde tanımlamak için aracın ölçme ünitesi gerçek zamanlı küresel yer belirleme sistemi (RTK-GPS), ataletsel ölçme ünitesi (IMU) ve mutlak enkoder sensörlerini içermektedir. Mobil robotun yörünge takibi için ardışık olarak doğrusallaştırılmış ve ayrıklaştırılmış kinematik bir modele dayalı model öngörülü kontrol kullanılmıştır. Bu optimal kontrol metodu verilen bir yol referansı üzerinde hatasız bir şekilde hareket ettiği kabul edilen holonomik olmayan sanal bir araca göre oluşan en küçük konum ve yönel hatalarına ek olarak en düzgün direksiyon açısının elde edilmesi üzerine işlevini gerçekleştirmektedir. Burada takip edilen yollar bir sayısal haritalama programından elde edilen kontrol noktaları ile oluşturulan rasyonel temelli eğriler (spline) veya bilindik geometrik eğriler ile tanımlanmaktadır. Bu makale hem benzetim hem de gerçek zamanlı deneysel test çalışmalarını içermektedir. Elde edilen sonuçlar aracın tasarım performansı ve kontrol stratejisi yönünden irdelenmiştir. Gerçek araç prototipi üzerindeki fiziksel sınırlandırmalara rağmen konum ve yönelim hatalarının makul sınırlar içerisinde oluştuğu gözlemlenmiştir. Özellikle direksiyon açısının aşırı bir salınıma maruz kalmaması kullanılan kontrol metodunun iyi bir performans gösterdiğini ifade etmektedir.