Abdullah Munir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abdullah Munir has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Abdur Raheem
Department of Electrical Engineering, NED University of Engineering and Technology, Karachi, Islamic Republic of Pakistan
1 shared publicationH.M.S. Adnan Ali
Department of Electrical Engineering, NED University of Engineering & Technology, Pakistan
1 shared publicationM.M. Aman
Department of Electrical Engineering, NED University of Engineering & Technology, Pakistan
1 shared publicationMuhammad Owais Malik
Department of Electrical Engineering, NED University of Engineering and Technology, Karachi, Islamic Republic of Pakistan
1 shared publicationShariq Shaikh
Department of Electrical Engineering, NED University of Engineering & Technology, Pakistan
1 shared publicationSyed Jowaid Ahmed
Department of Geography, University of Karachi, Pakistan
1 shared publication
Latest Publications
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Lightning Flash Density Map of Pakistan on ARC-GIS® Software - An Empirical Approach
Lightning is a natural hazard that can have severe effects both on electrical power system and in general. In order to plan for lightning protection it is necessary to map out the likely occurrence of lightning at any location across the country. In this paper lightning density map of Pakistan has been developed using Pakistan Metrology Department (PMD) data over the period 1960-1990 on Arc-GIS software® platform. Such map is helpful in planning protection system for utility company's network and in general for lightning risk assessment at country level. Further lightning map also helps in predicting aviation hazards severe storm and in understanding the weather in any country. The developed lightning map shows that Pakistan lightning flash density is highest in region around Murree reaching a maximum of 9.4 flashes per km2 per year and most of the areas of Pakistan have lowest density reaching a minimum value of hardly single flash/km2/yr.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Lightning Flash Density Map of Pakistan on ARC-GIS® Software - An Empirical Approach
Lightning is a natural hazard that can have severe effects both on electrical power system and in general. In order to plan for lightning protection it is necessary to map out the likely occurrence of lightning at any location across the country. In this paper lightning density map of Pakistan has been developed using Pakistan Metrology Department (PMD) data over the period 1960-1990 on Arc-GIS software® platform. Such map is helpful in planning protection system for utility company's network and in general for lightning risk assessment at country level. Further lightning map also helps in predicting aviation hazards severe storm and in understanding the weather in any country. The developed lightning map shows that Pakistan lightning flash density is highest in region around Murree reaching a maximum of 9.4 flashes per km2 per year and most of the areas of Pakistan have lowest density reaching a minimum value of hardly single flash/km2/yr.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 120-125
Implementation of low cost non-DFT based Phasor Measurement Unit for 50 Hz power system
The interconnection of several small & large systems has increased the probability of large blackouts in the power grid. One of the leading reason behind these blackouts is low reporting rate of existing devices and unavailability of synchronized system wide data. Synchrophasor technology provides solution to the problem. Phasor Measurement Unit (PMU) is the most front end device required to implement Synchrophasor Technology. The paper proposes a non-DFT based technique for development of PMU conformed to IEEE standards C37.118.1 and C37.118.2. The proposed technique aims to reduce the processing time & sampling rate which ultimately leads to reduced cost. The hardware of PMU is implemented using Raspberry pi Model B+, ADS1015 and GPS (Global Positioning System) model PA6H on MTK3339 chipset.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 120-125
Implementation of low cost non-DFT based Phasor Measurement Unit for 50 Hz power system
The interconnection of several small & large systems has increased the probability of large blackouts in the power grid. One of the leading reason behind these blackouts is low reporting rate of existing devices and unavailability of synchronized system wide data. Synchrophasor technology provides solution to the problem. Phasor Measurement Unit (PMU) is the most front end device required to implement Synchrophasor Technology. The paper proposes a non-DFT based technique for development of PMU conformed to IEEE standards C37.118.1 and C37.118.2. The proposed technique aims to reduce the processing time & sampling rate which ultimately leads to reduced cost. The hardware of PMU is implemented using Raspberry pi Model B+, ADS1015 and GPS (Global Positioning System) model PA6H on MTK3339 chipset.