Tomonobu Goto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tomonobu Goto has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
Hiroshi Yoshino
Tohoku University
8 shared publicationsTonau Nakai
Faculty of Engineering, Tottori University
8 shared publicationsTomoyuki Endo
7 shared publicationsTakashi Kurabuchi
6 shared publicationsKenichi Hasegawa
Akita Prefectural University
5 shared publicationsMakoto Koganei
5 shared publications
Latest Publications
- Open Access
- 3 February 2026
- Published by Springer Nature in International Journal of Biometeorology
- Vol. 70 (2) , 48
Human simulation model for predicting body temperature, blood pressure, and blood flow rate under various thermal exposures — Part 1: development of physical model for average Japanese male in their 20s
In the mechanism of thermal health problems, not only body temperature but also blood pressure and blood flow rate are key factors. Human body simulation is a useful tool for predicting these physiological quantities under various conditions. Therefore, we aimed to develop a new human-body simulation model to predict body temperature, blood pressure, and blood flow rate. Our model consists of a “physical model” that simulates the phenomena of heat and blood transfer based on the physical properties of the human body, and an “autonomic regulation model” that simulates the phenomena in which the physical properties of the human body are regulated by the activity of the autonomic nervous system. The physical model consists of a “thermal network (TNW) model” that simulates heat flow and body temperature, and a “cardiovascular (CV) model” that simulates blood flow and blood pressure. In this study, we focused only on developing the physical model. In addition, based on experimental data from a recent study, parameter settings were derived to simulate an average Japanese male in their 20s. By applying the derived parameter settings to the physical model developed in this study, we confirmed that the calculated body temperature, blood flow rate, and blood pressure under a thermally neutral and supine condition reproduced the experimental values well.
- 3 February 2026
- Published by Springer Nature in International Journal of Biometeorology
- Vol. 70 (2) , 48
Open AccessHuman simulation model for predicting body temperature, blood pressure, and blood flow rate under various thermal exposures — Part 1: development of physical model for average Japanese male in their 20s
In the mechanism of thermal health problems, not only body temperature but also blood pressure and blood flow rate are key factors. Human body simulation is a useful tool for predicting these physiological quantities under various conditions. Therefore, we aimed to develop a new human-body simulation model to predict body temperature, blood pressure, and blood flow rate. Our model consists of a “physical model” that simulates the phenomena of heat and blood transfer based on the physical properties of the human body, and an “autonomic regulation model” that simulates the phenomena in which the physical properties of the human body are regulated by the activity of the autonomic nervous system. The physical model consists of a “thermal network (TNW) model” that simulates heat flow and body temperature, and a “cardiovascular (CV) model” that simulates blood flow and blood pressure. In this study, we focused only on developing the physical model. In addition, based on experimental data from a recent study, parameter settings were derived to simulate an average Japanese male in their 20s. By applying the derived parameter settings to the physical model developed in this study, we confirmed that the calculated body temperature, blood flow rate, and blood pressure under a thermally neutral and supine condition reproduced the experimental values well.
- 27 November 2024
- Published by Elsevier in Sustainable Cities and Society
- Vol. 118
Developing a physiological-parameter-based thermal sensation model for warm-biased outdoor settings: The steady-state part
- 27 November 2024
- Published by Elsevier in Sustainable Cities and Society
- Vol. 118
Developing a physiological-parameter-based thermal sensation model for warm-biased outdoor settings: The steady-state part
- Open Access
- 11 September 2024
- Published by Elsevier in Building and Environment
- Vol. 266
Human body temperature and cardiovascular response to changes in ambient temperature and body posture
- 11 September 2024
- Published by Elsevier in Building and Environment
- Vol. 266
Open AccessHuman body temperature and cardiovascular response to changes in ambient temperature and body posture
- Open Access
- 1 January 2022
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 17 (3) , 22-00121-00121
Difference in the chemotaxis between monotrichous and peritrichous bacteria clarified by a numerical simulation and observation
We investigate difference in the chemotactic behavior between peritrichous bacteria (Salmonella typhimurium SJW1103) and monotrichous bacteria (Vibrio alginolyticus YM4). Bacterial chemotaxis occurs by suppressing the directional change and continue the straight swimming (run) when approaching the favorable region. The manner of the directional change differs between peritrichous and monotrichous bacteria, which may cause the difference in chemotaxis. The turn angle of a peritrichous bacterium tends to be random that change the posture by loosening the flagellar bundle, whereas a monotrichous bacterium with a single flagellum tend to turn behind by the rotational change of the flagellum. In the microscopic observation, chemotactic behavior of the cells is measured in the concentration gradient of the chemoattractant (L-serine) formed by diffusion from the tip of the glass capillary. V. alginolyticus cells accumulate around the attractant more rapidly and more densely than S. typhimurium. The numerical simulation where the observed run length and turn angle distribution were taken into account, well reproduces the observed result of the cells’ distribution. The reason for the higher number density in the monotrichous bacteria is the backward directional changes when receding from the attractant source. The degree of prolongation of average duration of runs toward the attractant source does not differ significantly between V. alginolyticus and S. typhimurium cells. Considering the probability with which the swimming direction changes in terms of approaching or receding from the attractant, we are able to relate quantitatively between the degree of accumulation and the turn angle distribution.
- 1 January 2022
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 17 (3) , 22-00121-00121
Open AccessDifference in the chemotaxis between monotrichous and peritrichous bacteria clarified by a numerical simulation and observation
We investigate difference in the chemotactic behavior between peritrichous bacteria (Salmonella typhimurium SJW1103) and monotrichous bacteria (Vibrio alginolyticus YM4). Bacterial chemotaxis occurs by suppressing the directional change and continue the straight swimming (run) when approaching the favorable region. The manner of the directional change differs between peritrichous and monotrichous bacteria, which may cause the difference in chemotaxis. The turn angle of a peritrichous bacterium tends to be random that change the posture by loosening the flagellar bundle, whereas a monotrichous bacterium with a single flagellum tend to turn behind by the rotational change of the flagellum. In the microscopic observation, chemotactic behavior of the cells is measured in the concentration gradient of the chemoattractant (L-serine) formed by diffusion from the tip of the glass capillary. V. alginolyticus cells accumulate around the attractant more rapidly and more densely than S. typhimurium. The numerical simulation where the observed run length and turn angle distribution were taken into account, well reproduces the observed result of the cells’ distribution. The reason for the higher number density in the monotrichous bacteria is the backward directional changes when receding from the attractant source. The degree of prolongation of average duration of runs toward the attractant source does not differ significantly between V. alginolyticus and S. typhimurium cells. Considering the probability with which the swimming direction changes in terms of approaching or receding from the attractant, we are able to relate quantitatively between the degree of accumulation and the turn angle distribution.
- 1 January 2020
- Published by Architectural Institute of Japan in Journal of Environmental Engineering (Transactions of AIJ)
- Vol. 85 (768) , 169-176
STUDY ON ASSOCIATION BETWEEN INDOOR THERMAL ENVIRONMENT OF RESIDENTIAL BUILDINGS AND CEREBROVASCULAR DISEASE
According to statistical data reported by the Japanese government, the major causes of death for Japanese people are cancer, heart disease and cerebrovascular disease. The incidence rate of cerebrovascular disease in particular is higher during winter than summer (Hayama, 2011). One possible reason for this seasonal difference is that exposure to low temperatures can cause fluctuations in blood pressure. In houses with poor thermal insulation, indoor temperature differences between heated and non-heated spaces, such as the bathroom, corridors, and lavatory can be larger during winter. Many houses in the Tohoku region have a poor thermal environment during winter, and the incidence rate of cerebrovascular disease in this area is the highest compared to the other areas in Japan. Hasegawa and Yoshino (1985) investigated indoor thermal environment in houses of Yamagata prefecture, which is included in Tohoku region, during the heating season and the death rate of cerebrovascular disease in 1983 and 1984. As a result, the temperature difference between the heated living room and the unheated rooms was found to be great. Also it was revealed that if the lavatory temperature was low or the bedroom was not heated, the occupants living in such houses statistically tended to be susceptible to cerebral vascular accident. In order to clarify the association between the indoor environment of residential buildings and cerebrovascular disease, an epidemiological survey of 188 elderly persons living in Yamagata Prefecture in the Tohoku region of Japan was conducted. The specific areas investigated included three rural towns (former Yahata town, former Haguro town and Asahi town) and these areas are same as the investigated areas about 30 years ago. The survey was divided into three phases. The first phase (Phase 1) was a cross-sectional questionnaire on housing characteristics related to the indoor thermal environment and occupants' lifestyle habits among elderly persons. This paper describes the results obtained from this questionnaire and presents the characteristics of the indoor thermal environment and occupants' lifestyle habits during winter. Moreover, an association between the increase in rate of death due to cerebrovascular disease and factors that influenced the indoor environment of houses is examined using multivariable logistic regression analysis. The multivariable logistic regression analysis shows that always feeling a draft in the living room while operating heating equipment (AOR, 8.14; 95%CI, 1.55-42.8) and low temperature in a living room at morning (AOR, 0.87; 95%CI, 0.78-0.98) was positively associated with an increased rate of death due to cerebrovascular disease for former Yahata town. These results indicate that a poor indoor thermal environment may contribute to an increase in the rate of death due to cerebrovascular disease. In addition, a high salt diet may contribute to the onset of cerebrovascular disease. When participants moved from a living room to a bathroom during winter, they reported thermal sensations, such as ‘warm’, ‘neutral’ and ‘cold’. AOR for ‘cold’ when entering a bathroom (AOR, 0.17; 95%CI, 0.05–0.58) was significant for former Yahata. These results indicate that occupants in this town did not feel cold, although the indoor temperatures among surveyed towns were similar. AOR for light clothing when staying at home was significant for former Yahata town and participants were thinly dressed during heating season. Therefore they may be more readily exposed to a cold indoor environment than other towns.
- 1 January 2020
- Published by Architectural Institute of Japan in Journal of Environmental Engineering (Transactions of AIJ)
- Vol. 85 (768) , 169-176
STUDY ON ASSOCIATION BETWEEN INDOOR THERMAL ENVIRONMENT OF RESIDENTIAL BUILDINGS AND CEREBROVASCULAR DISEASE
According to statistical data reported by the Japanese government, the major causes of death for Japanese people are cancer, heart disease and cerebrovascular disease. The incidence rate of cerebrovascular disease in particular is higher during winter than summer (Hayama, 2011). One possible reason for this seasonal difference is that exposure to low temperatures can cause fluctuations in blood pressure. In houses with poor thermal insulation, indoor temperature differences between heated and non-heated spaces, such as the bathroom, corridors, and lavatory can be larger during winter. Many houses in the Tohoku region have a poor thermal environment during winter, and the incidence rate of cerebrovascular disease in this area is the highest compared to the other areas in Japan. Hasegawa and Yoshino (1985) investigated indoor thermal environment in houses of Yamagata prefecture, which is included in Tohoku region, during the heating season and the death rate of cerebrovascular disease in 1983 and 1984. As a result, the temperature difference between the heated living room and the unheated rooms was found to be great. Also it was revealed that if the lavatory temperature was low or the bedroom was not heated, the occupants living in such houses statistically tended to be susceptible to cerebral vascular accident. In order to clarify the association between the indoor environment of residential buildings and cerebrovascular disease, an epidemiological survey of 188 elderly persons living in Yamagata Prefecture in the Tohoku region of Japan was conducted. The specific areas investigated included three rural towns (former Yahata town, former Haguro town and Asahi town) and these areas are same as the investigated areas about 30 years ago. The survey was divided into three phases. The first phase (Phase 1) was a cross-sectional questionnaire on housing characteristics related to the indoor thermal environment and occupants' lifestyle habits among elderly persons. This paper describes the results obtained from this questionnaire and presents the characteristics of the indoor thermal environment and occupants' lifestyle habits during winter. Moreover, an association between the increase in rate of death due to cerebrovascular disease and factors that influenced the indoor environment of houses is examined using multivariable logistic regression analysis. The multivariable logistic regression analysis shows that always feeling a draft in the living room while operating heating equipment (AOR, 8.14; 95%CI, 1.55-42.8) and low temperature in a living room at morning (AOR, 0.87; 95%CI, 0.78-0.98) was positively associated with an increased rate of death due to cerebrovascular disease for former Yahata town. These results indicate that a poor indoor thermal environment may contribute to an increase in the rate of death due to cerebrovascular disease. In addition, a high salt diet may contribute to the onset of cerebrovascular disease. When participants moved from a living room to a bathroom during winter, they reported thermal sensations, such as ‘warm’, ‘neutral’ and ‘cold’. AOR for ‘cold’ when entering a bathroom (AOR, 0.17; 95%CI, 0.05–0.58) was significant for former Yahata. These results indicate that occupants in this town did not feel cold, although the indoor temperatures among surveyed towns were similar. AOR for light clothing when staying at home was significant for former Yahata town and participants were thinly dressed during heating season. Therefore they may be more readily exposed to a cold indoor environment than other towns.
- 1 November 2019
- Published by Elsevier in Building and Environment
- Vol. 165
Winter indoor environment of elderly households: A case of rural regions in northeast and southeast China
- 1 November 2019
- Published by Elsevier in Building and Environment
- Vol. 165
Winter indoor environment of elderly households: A case of rural regions in northeast and southeast China
- 20 June 2019
- Published by Architectural Institute of Japan in AIJ Journal of Technology and Design
- Vol. 25 (60) , 789-793
A RESEARCH STUDY ON INDOOR SPATIAL RADIATION DOSE RATE OF A WOODEN DETACHED HOUSE BEFORE AND AFTER THE DECONTAMINATION WORK IN NUCLEAR POWER PLANT ACCIDENT AREA
This study explored changes in spatial radiation dose rate both indoor and outdoor associated with a decontamination operation for a wooden house in a high dose rate region in Fukushima. As a result, the averaged spatial dose rate at 1m height from the floor before the decontamination was 1.73μSv/h and the dose rate after the decontamination was 0.86μSv/h. Furthermore, the results of a comparison of the dose rate between pre- and post-decontamination indicates a decrease in the dose rate at almost all points. The reduction rate of spatial dose-rate was 40 to 50% at the center of the house.
- 20 June 2019
- Published by Architectural Institute of Japan in AIJ Journal of Technology and Design
- Vol. 25 (60) , 789-793
A RESEARCH STUDY ON INDOOR SPATIAL RADIATION DOSE RATE OF A WOODEN DETACHED HOUSE BEFORE AND AFTER THE DECONTAMINATION WORK IN NUCLEAR POWER PLANT ACCIDENT AREA
This study explored changes in spatial radiation dose rate both indoor and outdoor associated with a decontamination operation for a wooden house in a high dose rate region in Fukushima. As a result, the averaged spatial dose rate at 1m height from the floor before the decontamination was 1.73μSv/h and the dose rate after the decontamination was 0.86μSv/h. Furthermore, the results of a comparison of the dose rate between pre- and post-decontamination indicates a decrease in the dose rate at almost all points. The reduction rate of spatial dose-rate was 40 to 50% at the center of the house.
- 1 January 2019
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2019, J09113P
Acoustic modes in a flow duct with an uniform flow
Eduction of acoustic impedance of a sound absorbing material in grazing flow is often performed by using a flow duct. To understand the sound filed in the flow duct is effectual for more precise eduction. We investigated how the sound field in the flow duct whose top wall consists of a sound absorbing material with constant acoustic impedance changes with Mach number of the uniform flow. For various acoustic impedance values, propagation constants in the axial direction corresponding to 0th and 1st modes were calculated from the eigenvalue equation for a fixed value of the ratio of the flow duct height to the wave length (=1.21/2π). The value was determined to satisfy the cut off condition. The propagation constant represents the attenuation coefficient and the phase change rate in the axial direction. The following were obtained. The attenuation coefficient in the 0th mode decreases as the Mach number increases when the reactance is negative. This tendency is apparent when the resistance is small. In the 1st mode, the attenuation coefficient decreases in most calculated cases. As the Mach number increases, the phase in the axial direction changes more rapidly when the reactance is negative, and it changes more slowly when the reactance is positive. As for the case in which the attenuation coefficients of the 0th and 1st modes are comparative, the attenuation coefficient in the 0th mode decreases with the increase in the Mach number, but that in the 1st mode increases. Consequently, the 0th mode becomes dominant.
- 1 January 2019
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2019, J09113P
Acoustic modes in a flow duct with an uniform flow
Eduction of acoustic impedance of a sound absorbing material in grazing flow is often performed by using a flow duct. To understand the sound filed in the flow duct is effectual for more precise eduction. We investigated how the sound field in the flow duct whose top wall consists of a sound absorbing material with constant acoustic impedance changes with Mach number of the uniform flow. For various acoustic impedance values, propagation constants in the axial direction corresponding to 0th and 1st modes were calculated from the eigenvalue equation for a fixed value of the ratio of the flow duct height to the wave length (=1.21/2π). The value was determined to satisfy the cut off condition. The propagation constant represents the attenuation coefficient and the phase change rate in the axial direction. The following were obtained. The attenuation coefficient in the 0th mode decreases as the Mach number increases when the reactance is negative. This tendency is apparent when the resistance is small. In the 1st mode, the attenuation coefficient decreases in most calculated cases. As the Mach number increases, the phase in the axial direction changes more rapidly when the reactance is negative, and it changes more slowly when the reactance is positive. As for the case in which the attenuation coefficients of the 0th and 1st modes are comparative, the attenuation coefficient in the 0th mode decreases with the increase in the Mach number, but that in the 1st mode increases. Consequently, the 0th mode becomes dominant.
- 1 January 2019
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2019, 2A2-R07
Difference in Chemotaxis of Salmonella Cells between Serine and Aspartic Acid
Peritrichous bacteria exhibit chemotaxis that cells accumulate around an attractant or recede from a repellent by repeating straight swimming and turning direction. As for chemotaxis of Salmonella typhimurium, cells are known to accumulate around aspartic acid in a shorter time than serine. In this study, we clarify that aspartic acid shows chemotaxis even at lower concentrations by measuring the degree of accumulation of bacteria by variously changing the concentration of the attractant in the capillary. In addition, the chemotactic behaviors (frequency of directional change and swimming trajectory) of a single cell were compared, but the behaviors were almost the same between serine and aspartic acid.
- 1 January 2019
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2019, 2A2-R07
Difference in Chemotaxis of Salmonella Cells between Serine and Aspartic Acid
Peritrichous bacteria exhibit chemotaxis that cells accumulate around an attractant or recede from a repellent by repeating straight swimming and turning direction. As for chemotaxis of Salmonella typhimurium, cells are known to accumulate around aspartic acid in a shorter time than serine. In this study, we clarify that aspartic acid shows chemotaxis even at lower concentrations by measuring the degree of accumulation of bacteria by variously changing the concentration of the attractant in the capillary. In addition, the chemotactic behaviors (frequency of directional change and swimming trajectory) of a single cell were compared, but the behaviors were almost the same between serine and aspartic acid.
- 1 May 2018
- Published by Elsevier in Energy and Buildings
- Vol. 167, 334-346
Indoor environmental conditions in urban and rural homes with older people during heating season: A case in cold region, China
- 1 May 2018
- Published by Elsevier in Energy and Buildings
- Vol. 167, 334-346
Indoor environmental conditions in urban and rural homes with older people during heating season: A case in cold region, China