NANeha Anegondi

Neha Anegondi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Neha Anegondi has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Prospective OCT Study of Rubella Retinopathy

    by Jyoti Matalia, Anand Vinekar, Neha Anegondi, Shwetha Mangalesh, Hemant Anaspure, K. Bhujang Shetty, Abhijit Sinha Roy


  • Quantitative Comparison Between Optical Coherence Tomography Angiography and Fundus Fluorescein Angiography Images: Effect of Vessel Enhancement

    by Thirumalesh Mochi, Neha Anegondi, Molleti Girish, Chaitra Jayadev, Abhijit Sinha Roy

    BACKGROUND AND OBJECTIVE: To compare the vascular parameters derived from optical coherence tomography angiography (OCTA) and fundus fluorescein angiography (FFA) images. PATIENTS AND METHODS: Twenty-two eyes of 22 patients were imaged with OCTA and FFA. FFA images were cropped to the same dimension as OCTA images after registration. Vessel enhancement using a Frangi filter and local fractal analysis was applied to the superficial layer of the OCTA and cropped FFA images. Foveal avascular zone (FAZ) area, vessel density, spacing between large vessels, and spacing between small vessels were quantified. RESULTS: FAZ area was similar between original OCTA, Frangi-filtered OCTA, and FFA images (P = .32). Actual OCTA images had significantly higher vessel density (35.2% ± 1.45%, P < .001) than Frangi-filtered OCTA images (29.8% ± 0.78%) and Frangi-filtered FFA images (25.5% ± 2.41%). Spacing between large vessels was significantly lower in original OCTA images (31.9% ± 1.47%, P < .001) than Frangi-filtered OCTA images (36.8% ± 1.24%) and Frangi-filtered FFA images (60.1% ± 2.68%). Further, FFA images had significantly lower spacing between small vessels (14.4% ± 0.43%, P < .001) than original OCTA images (32.7% ± 1.03%) and Frangi-filtered OCTA images (33.4% ± 0.81%). CONCLUSION: FAZ area was similar between OCTA and FFA, independent of vessel enhancement. However, vessel enhancement improved the agreement of vascular parameters between OCTA and FFA images of the same eye. [ Ophthalmic Surg Lasers Imaging Retina . 2018;49:e175–e181.]


  • Quantitative Comparison of Retinal Vascular Features in Optical Coherence Tomography Angiography Images From Three Different Devices

    by Neha Anegondi, Arpita Kshirsagar, Thirumalesh B. Mochi, Abhijit Sinha Roy

    BACKGROUND AND OBJECTIVE: To compare optical coherence tomography angiography (OCTA) images from three different devices. PATIENTS AND METHODS: This was a prospective, observational, cross-sectional study. All eyes (n = 24) were imaged thrice each time with swept-source OCT (DRI OCT Triton Plus; Topcon, Tokyo, Japan), spectral-domain OCTA (AngioVue; Optovue, Fremont, CA), and SD-OCT Angioplex (Cirrus HD-OCT 5000; Carl Zeiss Meditec, Jena, Germany). Outcome measures were foveal avascular zone (FAZ) area, vessel density, spacing between large vessels (SLV), and spacing between small vessels (SSV). They were calculated using local fractal analyses and Frangi filter. RESULTS: The vascular parameters showed good to excellent repeatability (intraclass coefficient > 0.8) in the three devices. The FAZ area ( P = .3) and vessel density of the superficial layer ( P = .8) were similar between the devices. In the deep layer, vessel density was significantly higher ( P = .02) with Angio-Vue images compared to those acquired using the other devices. However, SLV was significantly higher ( P < .05) and SSV was significantly lower ( P < .05) on Angioplex scans compared to other devices. Vessel parameters were significantly altered in Frangi-filtered images as compared to nonfiltered images. CONCLUSIONS: Vessel density showed good repeatability among the three devices, although there were differences in vessel parameters between the devices. Also, vessel parameters changed significantly after Frangi filtering. [ Ophthalmic Surg Lasers Imaging Retina . 2018;49:488–496.]


  • Quantitative evaluation of optical coherence tomography angiography images of diabetic retinopathy eyes before and after removal of projection artifacts

    by Nivedhitha Govindaswamy, Santosh G. Gadde, Lavanya Chidambara, Devanshi Bhanushali, Neha Anegondi, Abhijit Sinha Roy

    Projection artifacts (PAs) affect the quantification of vascular parameters in the deep layer optical coherence tomography (OCT) angiography image. This study eliminated PA and quantified its effect on imaging. 53 eyes (30 subjects) of normal Indian subjects and 113 eyes (92 patients) of type 2 diabetes mellitus with retinopathy (DR) underwent imaging with a scan area of 3 mm × 3 mm. In this study, a normalized cross‐correlation between superficial and deep layer was used to remove PA in deep layer. Local fractal analysis was done to compute vascular parameters such as foveal avascular zone area (mm2), vessel density (%), spacing between large vessels (%) and spacing between small vessels (%). Before PA removal, vessel density for mild nonproliferative (NPDR), moderate NPDR, severe NPDR and proliferative DR were 42.56 ±1.69%, 40.69 ±0.72%, 37.34 ±0.85% and 35.61 ±1.26%, respectively. After artifact removal, vessel density was 28.9 ±1.22%, 29.9 ±0.56%, 26.19 ±0.59% and 24.02 ±0.94%, respectively. All the vascular parameters were statistically significant (P <.001) between normal and disease eyes, irrespective of superficial and deep retinal layers. Parafoveal sectoral analyses showed that temporal zone had the lowest vessel density and may undergo DR‐related changes first. The current approach enabled rapid and accurate quantitative interpretation of DR eyes, without PA.


  • Age and myopia associated optical coherence tomography of retina and choroid in pediatric eyes

    by Jyoti Matalia, Neha Sutheekshna Anegondi, Leio Veeboy, Abhijit Sinha Roy

    Purpose: To evaluate the association between retinal and choroidal thickness and volume along with choroidal vessel volume in children using optical coherence tomography (OCT) images. Methods: 113 normal eyes of children ranging from 5-17 years of age were imaged with a clinical OCT scanner (Optovue Inc., Fremont, USA). The retina, choroid and choroidal vessels were automatically segmented with algorithms. Parameters evaluated were thickness and volume. Location specific analyses of thickness were also performed at a distance of 2.5 mm from foveal center. Multivariate analyses of variance were used to analyze the effect of age and myopia. Manual segmentation of the fovea and subfoveal choroid thickness was also performed to compare with the algorithm segmentation. Results: There was excellent agreement between manual and automatic segmentation (intra-class correlation of 0.95). Within the same eye, total retinal and choroid thickness of nasal and temporal location were significantly lower than the superior and inferior thickness (P < 0.0001). With age (P = 0.026) and myopia (P < 0.001), foveal thickness increased. Choroid volume, vessel volume and temporal choroid thickness increased with increasing myopia (P < 0.05). There was significant positive correlation between choroid volume and retinal volume (r = 0.62, P < 0.0001), choroid volume and vessel volume (r = 0.48, P < 0.0001), and with foveal thickness (r = 0.31, P = 0.009). Choroid vessel volume also showed significant positive correlations with the other metrics (P < 0.05). Conclusion: Retinal and choroidal structural features were quantified simultaneously from OCT images. Magnitude of myopia had a greater effect on retino-choroid features than age in children.


  • An automated framework to quantify areas of regional ischemia in retinal vascular diseases with OCT angiography

    by Neha Anegondi, Lavanya Chidambara, Devanshi Bhanushali, Santosh G. K. Gadde, Naresh Kumar Yadav, Abhijit Sinha Roy

    In this observational and cross‐sectional study, capillary nonperfusion (CNP) and vascular changes in branch retinal vein occlusion (BRVO, sample size [n] = 26) and choroidal neovascularization (CNV, n = 29) were evaluated. Subjects underwent imaging using Optical coherence tomography angiography (Angiovue OCTA, RTVue XR, Optovue Inc., Fremont, California). Local fractal analysis was applied to the OCTA images of superficial, deep and choriocapillaris layer. CNP area (BRVO eyes) and vascular parameters were computed using local fractal‐based method. Sensitivity and specificity of vascular parameters were assessed with receiver operating characteristics curve. Automated CNP area showed excellent agreement with manually quantified CNP areas in both superficial (intraclass coefficient [ICC] = 0.96) and deep (ICC = 0.96) layers. BRVO eyes showed significantly altered (P < .05) vascular parameters in both superficial and deep layer as compared to normal eyes (n = 30). CNVM eyes had significantly higher capillary free zones (P < .001) as compared to normal eyes. In normal vs BRVO eyes, vessel density and spacing between the large vessels had similar area under the curve (AUC) (P > .05) in both superficial (0.97 and 0.97, respectively) and deep layer (0.99 and 0.98, respectively). Further, capillary free zones showed high AUC (0.92) in differentiating CNV eyes from normal eyes.


  • Open Access

    Discriminant Function of Optical Coherence Tomography Angiography to Determine Disease Severity in Glaucoma

    by Rajesh S. Kumar, Neha Anegondi, Rachana S. Chandapura, Suria Sudhakaran, Sujatha V. Kadambi, Harsha L. Rao, Tin Aung, Abhijit Sinha Roy

    Purpose: To determine the discriminant function of optical coherence tomography angiography (OCTA) by disease severity in glaucoma. Methods: In this prospective, observational cross-sectional study, all subjects underwent visual fields, retinal nerve fiber layer (RNFL) measurements, and OCTA imaging. Local fractal analysis was applied to OCTA images (radial peripapillary capillaries [RPC] layer). Vessel density en face and inside the disc and spacing between large and small vessels were quantified. Stepwise logistic regression was performed and a glaucoma severity score (range, 0–1: 0, normal; 1, severe glaucoma) was developed by using global and regional (superotemporal [ST], inferotemporal [IT], temporal, superonasal [SN], inferonasal, and nasal) vascular parameters. Glaucoma severity score was compared with visual field and RNFL indices. Results: One hundred ninety-nine eyes (112 subjects) with glaucoma (28 eyes preperimetric; 83 early, 43 moderate, and 45 severe glaucoma) and 74 normal (54 subjects) eyes were enrolled. Preperimetric and glaucomatous eyes had significantly altered (P < 0.001) global vascular parameters as compared to normal; regionally, ST, then SN and IT sectors (in that order) showed more change in glaucomatous eyes. Vascular parameters showed better discriminant ability (area under the curve [AUC], sensitivity, and specificity of 0.70, 69.2%, and 72.9%, respectively) than structural parameters between normal and preperimetric glaucomatous eyes. Vascular parameters had comparable AUC (P > 0.05) to visual fields for perimetric glaucoma. Glaucoma severity score identified preperimetric glaucoma and early glaucoma better than did visual fields. Conclusions: Vascular parameters could be a useful adjunct tool to evaluate/diagnose glaucoma. Longitudinal studies are needed to determine their use in early detection and prognostication.


  • Open Access

    Linking Retinal Microvasculature Features With Severity of Diabetic Retinopathy Using Optical Coherence Tomography Angiography

    by Devanshi Bhanushali, Neha Anegondi, Santosh G. K. Gadde, Priya Srinivasan, Lavanya Chidambara, Naresh Kumar Yadav, Abhijit Sinha Roy

    Purpose: To correlate retinal vascular features with severity and systemic indicators of diabetic retinopathy (DR) using optical coherence tomography angiography (OCTA). Methods: A total of 209 eyes of 122 type 2 diabetes mellitus patients with DR and 60 eyes of 31 normal Indian subjects underwent OCTA imaging. The diabetic retinopathy patients were graded as having either nonproliferative diabetic retinopathy (NPDR: mild, moderate, and severe NPDR using Early Treatment Diabetic Retinopathy Study classification) or proliferative diabetic retinopathy (PDR). Local fractal analysis was applied to the superficial and deep retinal OCTA images. Foveal avascular zone area (FAZ in mm2); vessel density (%); spacing between large vessels (%); and spacing between small vessels (%) were analyzed. Sensitivity and specificity of vascular parameters were assessed with receiver operating characteristics (ROC) curve. Results: Normal eyes had a significantly lower FAZ area, higher vessel density, and lower spacing between large and small vessels compared with DR grades (P < 0.001). In the superficial layer, PDR and severe NPDR had higher spacing between large vessels than mild and moderate NPDR (P = 0.04). However, mild NPDR had higher spacing between the small vessels (P < 0.001). Spacing between the large vessels in the superficial retinal layer correlated positively with HbA1c (r = 0.25, P = 0.03); fasting (r = 0.23, P = 0.02); and postprandial (r = 0.26, P = 0.03) blood sugar. The same spacing in the deep retinal vascular plexus had the highest area under the ROC curve (0.99 ± 0.01) and was uniformly elevated in all diabetic eyes (P > 0.05). Conclusions: Spacing between the large vessels in the superficial and deep retinal layers had superior diagnostic performance than overall vessel density.


  • Open Access

    Author Response: Quantification of Vessel Density in Retinal Optical Coherence Tomography Angiography Images Using Local Fractal Dimension

    by Santosh G. K. Gadde, Neha Anegondi, Devanshi Bhanushali, Lavanya Chidambar, Naresh Kumar Yadav, Aruj Khurana, Abhijit Sinha Roy

    FIGURE 1. (A) Optical coherence tomography angiography (OCTA) image of the superficial retinal vascular plexus of size 3 • 3 mm with motion artifacts. (B) Corresponding contour map created with normalized ratio of local fractal dimension values.


  • Open Access

    Quantification of Vessel Density in Retinal Optical Coherence Tomography Angiography Images Using Local Fractal Dimension

    by Santosh G. K. Gadde, Neha Anegondi, Devanshi Bhanushali, Lavanya Chidambara, Naresh Kumar Yadav, Aruj Khurana, Abhijit Sinha Roy

    Purpose: To evaluate a fully automated local fractal dimension method to quantify vessel density and foveal avascular zone (FAZ) area in optical coherence tomography angiography (OCTA) images. Methods: Fifty-two healthy Asian Indian eyes underwent imaging prospectively with OCTA system. Superficial and deep retinal vascular plexus was imaged. Local fractal analysis was applied to the OCTA images. A scan area of 3 × 3 mm was selected in the superficial and deep retinal layers. Foveal avascular zone area and vessel density were quantified in circular and sectoral zones around the fovea. A unique contour map of vessel density and dropout zones was developed to perform regional comparisons. Results: Foveal avascular zone of superficial (0.35 ± 0.013 mm2) and deep (0.49 ± 0.012 mm2) retinal vascular plexus was segmented. The agreement between the manually segmented and local fractal dimension segmented FAZ area was 0.97 (95% confidence interval [CI]: 0.94–0.98) and did not change significantly with age (P = 0.94 and 0.21, respectively). The vessel density was greater in the deep than the superficial retinal vascular plexus (P < 0.0001). When the image was subdivided into sectors around the FAZ, inferior sector had greater vessel density than the others (temporal, superior, and nasal) in both superficial and deep retinal vascular plexus (P < 0.05). These observations were similar to recent studies on animal retinal vasculature map. Conclusions: A novel implementation of local fractal dimension to calculate vessel density and FAZ area was demonstrated. Age did not impact vessel density but sectoral analyses showed greater vessel density in the inferior zone.