Chunhui Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chunhui Li has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Lishui Cui
National Institute of Metrology (NIM), Beijing 100029, P. R. China
2 shared publications- Peijuan Cao
Tianjin Key Laboratory of Process Measurement and Control, School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China
2 shared publications - Chao Wang
School of Electrical and Information Engineering, Tianjin University, Tianjin, China
1 shared publication - Han Zhang
School of Traffic and Transportation, Beijing Jiaotong University, Beijing 100044, China
1 shared publication - Hongbing Ding
School of Electrical and Information Engineering, Tianjin University, Tianjin, China
1 shared publication Peijuan Cao
1 shared publication
Latest Publications
- 26 July 2025
- Published by Elsevier in Measurement
- Vol. 256
Experimental investigation of critical flow in a venturi nozzle facility with hydrogen at pressures up to 70 MPa
- 26 July 2025
- Published by Elsevier in Measurement
- Vol. 256
Experimental investigation of critical flow in a venturi nozzle facility with hydrogen at pressures up to 70 MPa
- 7 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-16
The Thermal Effect on Discharge Coefficient of Sonic Nozzle Based on Reconstructed Body Temperature Distribution by Improved SOR Method
For the sonic nozzles, the discharge coefficient (Cd) is an essential parameter of flow characteristics, which is obviously influenced by the thermal effect determined by the nozzle body temperature distribution. In this study, two types of thermocouple arrays for temperature acquisition of nozzle body were designed to investigate the thermal effect. The temperature isothermal maps of nozzle body were reconstructed by improved Successive Over-relaxation (SOR) method combining the Simple Kriging Interpolation Method and Particle Swarm Optimization (SKIM-PSO), which can effectively eliminate the phenomenon of bull’s eye and non-smoothness of the SKIM. And then, the accuracy of the new algorithm were checked by cross validation with test sets of d = 5.25 mm nozzles with different structure. It is found that the maximum error Δemax of the new algorithm is less than 0.2 °C. Thermal effect on discharge coefficient was analyzed with above reconstructed temperature distribution, which is classified into two aspects, the thermal boundary layer correction factor CT and the constrained thermal deformation correction factor Ca related with the throat area. The CT is 1-3.845Ret -0.5ΔT/T from similar solution of the boundary layer. Unlike the free expansion, the slopes of the Ca of constrained expansion for three AISI304 nozzles with d = 2.00, 5.25 and 7.45 mm are -1.24×10-5, +1.98×10-5 and +2.49×10-5, respectively. With the correction of CT and Ca, the prediction error of discharge coefficient is reduced from 0.14% 0.15% to 0.08% 0.1% for d = 2.00 and 7.45 mm two nozzles.
- 7 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-16
The Thermal Effect on Discharge Coefficient of Sonic Nozzle Based on Reconstructed Body Temperature Distribution by Improved SOR Method
For the sonic nozzles, the discharge coefficient (Cd) is an essential parameter of flow characteristics, which is obviously influenced by the thermal effect determined by the nozzle body temperature distribution. In this study, two types of thermocouple arrays for temperature acquisition of nozzle body were designed to investigate the thermal effect. The temperature isothermal maps of nozzle body were reconstructed by improved Successive Over-relaxation (SOR) method combining the Simple Kriging Interpolation Method and Particle Swarm Optimization (SKIM-PSO), which can effectively eliminate the phenomenon of bull’s eye and non-smoothness of the SKIM. And then, the accuracy of the new algorithm were checked by cross validation with test sets of d = 5.25 mm nozzles with different structure. It is found that the maximum error Δemax of the new algorithm is less than 0.2 °C. Thermal effect on discharge coefficient was analyzed with above reconstructed temperature distribution, which is classified into two aspects, the thermal boundary layer correction factor CT and the constrained thermal deformation correction factor Ca related with the throat area. The CT is 1-3.845Ret -0.5ΔT/T from similar solution of the boundary layer. Unlike the free expansion, the slopes of the Ca of constrained expansion for three AISI304 nozzles with d = 2.00, 5.25 and 7.45 mm are -1.24×10-5, +1.98×10-5 and +2.49×10-5, respectively. With the correction of CT and Ca, the prediction error of discharge coefficient is reduced from 0.14% 0.15% to 0.08% 0.1% for d = 2.00 and 7.45 mm two nozzles.
- 1 April 2018
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 60, 105-109
Throat diameter influence on the flow characteristics of a critical Venturi sonic nozzle
- 1 April 2018
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 60, 105-109
Throat diameter influence on the flow characteristics of a critical Venturi sonic nozzle