Emeline Laborie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Emeline Laborie has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Fabio Sterpone
Université Paris Cité, CNRS, Laboratoire de Biochimie Théorique, Paris, France
2 shared publications - Simone Melchionna
IAC-CNR , Via dei Taurini 19, Rome 00185
2 shared publications - Aleksey V. Belyaev
Moscow State University
1 shared publication - Andrew Callan-Jones
Laboratoire Matière et Systèmes Complexes, Université Paris Cité/CNRS (UMR 7057), Paris, France
1 shared publication - Daria O. Yurkova
Faculty of Physics, Lomonosov Moscow State University, 119991 Moscow, Russia
1 shared publication - Emmanuel Messas
Département cardiovasculaire, Hôpital Européen Georges-Pompidou, Université Paris Cité, Inserm UMR 970
1 shared publication
Latest Publications
- 7 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Development of an in-silico multi-scale framework to simulate mucociliary clearance
Développement d'un modèle multi-échelle in-silico pour simuler la clairance mucociliaire: Dans les voies respiratoires, la moitié de la surface épithéliale est couverte de cils. Les cils sont des filaments motiles ressemblant à des poils animés d'un mouvement de battement périodique et asymétrique. Ils sont en grande partie immergés dans une couche de fluide semblable à de l'eau, appelée la couche périciliaire et sont couverts d'une seconde couche de fluide visqueux appelée le mucus. Leur mouvement de battement leur permet de pousser sur la couche de mucus, et ce faisant, de débarrasser la trachée des poussières et pathogènes piégés à l'intérieur. Ce processus s'appelle la clairance mucociliaire et constitue le premier mécanisme de défense des voies respiratoires contre les particules potentiellement nocives inhalées. De ce fait, tout dysfonctionnement de l'un des composants de ce mécanisme, notamment des cils ou du mucus, est à l'origine de maladies respiratoires innées comme la Dyskinésie Ciliaire Primitive (DCP), ou acquises comme la COVID-19. Dans notre travail, nous utilisons la méthode de Boltzmann sur réseau couplée à la Dynamique Moléculaire pour étudier l'efficacité de la clairance mucociliaire. Nous commençons par implémenter et optimiser un modèle phénoménologique des cils basé sur un réseau élastique, et un modèle explicite de la couche de mucus, à l'échelle mésoscopique, paramétrés pour reproduire des conditions de santé normale. Ensuite, nous étudions l'influence d'un placement irrégulier des cellules ciliées sur la surface épithéliale ou d'une distribution désordonnée de leurs directions de battement, sur la coordination du battement des cils, la dynamique du fluide environnant et la clairance du mucus. Finalement, nous introduisons des défauts dans le tapis de cils afin d'émuler des caractéristiques pathologiques. Nous examinons comment la réduction de la surface ciliée ou l'immotilité de certaines cellules ciliées, reproduisant respectivement les effets d'une infection virale ou de la DCP, affectent l'efficacité du transport de mucus.
- 7 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Development of an in-silico multi-scale framework to simulate mucociliary clearance
Développement d'un modèle multi-échelle in-silico pour simuler la clairance mucociliaire: Dans les voies respiratoires, la moitié de la surface épithéliale est couverte de cils. Les cils sont des filaments motiles ressemblant à des poils animés d'un mouvement de battement périodique et asymétrique. Ils sont en grande partie immergés dans une couche de fluide semblable à de l'eau, appelée la couche périciliaire et sont couverts d'une seconde couche de fluide visqueux appelée le mucus. Leur mouvement de battement leur permet de pousser sur la couche de mucus, et ce faisant, de débarrasser la trachée des poussières et pathogènes piégés à l'intérieur. Ce processus s'appelle la clairance mucociliaire et constitue le premier mécanisme de défense des voies respiratoires contre les particules potentiellement nocives inhalées. De ce fait, tout dysfonctionnement de l'un des composants de ce mécanisme, notamment des cils ou du mucus, est à l'origine de maladies respiratoires innées comme la Dyskinésie Ciliaire Primitive (DCP), ou acquises comme la COVID-19. Dans notre travail, nous utilisons la méthode de Boltzmann sur réseau couplée à la Dynamique Moléculaire pour étudier l'efficacité de la clairance mucociliaire. Nous commençons par implémenter et optimiser un modèle phénoménologique des cils basé sur un réseau élastique, et un modèle explicite de la couche de mucus, à l'échelle mésoscopique, paramétrés pour reproduire des conditions de santé normale. Ensuite, nous étudions l'influence d'un placement irrégulier des cellules ciliées sur la surface épithéliale ou d'une distribution désordonnée de leurs directions de battement, sur la coordination du battement des cils, la dynamique du fluide environnant et la clairance du mucus. Finalement, nous introduisons des défauts dans le tapis de cils afin d'émuler des caractéristiques pathologiques. Nous examinons comment la réduction de la surface ciliée ou l'immotilité de certaines cellules ciliées, reproduisant respectivement les effets d'une infection virale ou de la DCP, affectent l'efficacité du transport de mucus.
- Open Access
Power-law decay of force on cell membrane tethers reflects long-ranged relaxation of membrane tension
Membrane tension is an acknowledged regulator of a wide array of cell functions; however, whether it acts locally or globally in different contexts remains debated. Recent experiments that locally perturb tension and measure the response elsewhere on the membrane are not conclusive, and the mechanism of diffusive tension relaxation has been called into doubt. Here, we consider the tension response to a sudden extension of a membrane tether, and report a quantitative signature of dynamic tension relaxation, which up to now is missing. We present a theory based on tension diffusion leading to a prediction of power-law decay in time of the force holding the tether, with a material-independent exponent of 1 / 3. This prediction is confirmed to within a few percent by re-analyzing eleven sets of tether data from two cell types with distinct membrane cortical architectures. Overall, our scaling results indicate the absence of a relevant characteristic length and therefore generically reflect tension relaxation by long-range membrane lipid flows.
Open AccessPower-law decay of force on cell membrane tethers reflects long-ranged relaxation of membrane tension
Membrane tension is an acknowledged regulator of a wide array of cell functions; however, whether it acts locally or globally in different contexts remains debated. Recent experiments that locally perturb tension and measure the response elsewhere on the membrane are not conclusive, and the mechanism of diffusive tension relaxation has been called into doubt. Here, we consider the tension response to a sudden extension of a membrane tether, and report a quantitative signature of dynamic tension relaxation, which up to now is missing. We present a theory based on tension diffusion leading to a prediction of power-law decay in time of the force holding the tether, with a material-independent exponent of 1 / 3. This prediction is confirmed to within a few percent by re-analyzing eleven sets of tether data from two cell types with distinct membrane cortical architectures. Overall, our scaling results indicate the absence of a relevant characteristic length and therefore generically reflect tension relaxation by long-range membrane lipid flows.
- 2 March 2023
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 158 (9) , 095103
An operative framework to model mucus clearance in silico by coupling cilia motion with the liquid environment
Mucociliary clearance is the first defense mechanism of the respiratory tract against inhaled particles. This mechanism is based on the collective beating motion of cilia at the surface of epithelial cells. Impaired clearance, either caused by malfunctioning or absent cilia, or mucus defects is a symptom of many respiratory diseases. Here, by exploiting the Lattice Boltzmann particle dynamics technique, we develop a model to simulate the dynamics of multiciliated cells in a two-layer fluid. Firstly, we tuned our model to reproduce the characteristic length- and time-scales of the cilia beating. We then check for the emergence of the metachronal wave as a consequence of hydrodynamic mediated correlations between beating cilia. Finally we tune the viscosity of the top fluid layer to simulate the mucus flow upon cilia beating, and evaluate the pushing efficiency of a carpet of cilia. With this work, we build a realistic framework that can be used to go explore several important physiological aspects of mucoliary clearance.
- 2 March 2023
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 158 (9) , 095103
An operative framework to model mucus clearance in silico by coupling cilia motion with the liquid environment
Mucociliary clearance is the first defense mechanism of the respiratory tract against inhaled particles. This mechanism is based on the collective beating motion of cilia at the surface of epithelial cells. Impaired clearance, either caused by malfunctioning or absent cilia, or mucus defects is a symptom of many respiratory diseases. Here, by exploiting the Lattice Boltzmann particle dynamics technique, we develop a model to simulate the dynamics of multiciliated cells in a two-layer fluid. Firstly, we tuned our model to reproduce the characteristic length- and time-scales of the cilia beating. We then check for the emergence of the metachronal wave as a consequence of hydrodynamic mediated correlations between beating cilia. Finally we tune the viscosity of the top fluid layer to simulate the mucus flow upon cilia beating, and evaluate the pushing efficiency of a carpet of cilia. With this work, we build a realistic framework that can be used to go explore several important physiological aspects of mucoliary clearance.
- Open Access
Exposure of Von Willebrand Factor Cleavage Site in A1A2A3-Fragment under Extreme Hydrodynamic Shear
Von Willebrand Factor (vWf) is a giant multimeric extracellular blood plasma involved in hemostasis. In this work we present multi-scale simulations of its three-domains fragment A1A2A3. These three domains are essential for the functional regulation of vWf. Namely the A2 domain hosts the site where the protease ADAMTS13 cleavages the multimeric vWf allowing for its length control that prevents thrombotic conditions. The exposure of the cleavage site follows the elongation/unfolding of the domain that is caused by an increased shear stress in blood. By deploying Lattice Boltzmann molecular dynamics simulations based on the OPEP coarse-grained model for proteins, we investigated at molecular level the unfolding of the A2 domain under the action of a perturbing shear flow. We described the structural steps of this unfolding that mainly concerns the -strand structures of the domain, and we compared the process occurring under shear with that produced by the action of a directional pulling force, a typical condition of single molecule experiments. We observe, that under the action of shear flow, the competition among the elongational and rotational components of the fluid field leads to a complex behaviour of the domain, where elongated structures can be followed by partially collapsed melted globule structures with a very different degree of exposure of the cleavage site. Our simulations pose the base for the development of a multi-scale in-silico description of vWf dynamics and functionality in physiological conditions, including high resolution details for molecular relevant events, e.g., the binding to platelets and collagen during coagulation or thrombosis.Open AccessExposure of Von Willebrand Factor Cleavage Site in A1A2A3-Fragment under Extreme Hydrodynamic Shear
Von Willebrand Factor (vWf) is a giant multimeric extracellular blood plasma involved in hemostasis. In this work we present multi-scale simulations of its three-domains fragment A1A2A3. These three domains are essential for the functional regulation of vWf. Namely the A2 domain hosts the site where the protease ADAMTS13 cleavages the multimeric vWf allowing for its length control that prevents thrombotic conditions. The exposure of the cleavage site follows the elongation/unfolding of the domain that is caused by an increased shear stress in blood. By deploying Lattice Boltzmann molecular dynamics simulations based on the OPEP coarse-grained model for proteins, we investigated at molecular level the unfolding of the A2 domain under the action of a perturbing shear flow. We described the structural steps of this unfolding that mainly concerns the -strand structures of the domain, and we compared the process occurring under shear with that produced by the action of a directional pulling force, a typical condition of single molecule experiments. We observe, that under the action of shear flow, the competition among the elongational and rotational components of the fluid field leads to a complex behaviour of the domain, where elongated structures can be followed by partially collapsed melted globule structures with a very different degree of exposure of the cleavage site. Our simulations pose the base for the development of a multi-scale in-silico description of vWf dynamics and functionality in physiological conditions, including high resolution details for molecular relevant events, e.g., the binding to platelets and collagen during coagulation or thrombosis. - 3 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (6) , 2117-2128
Dealiasing High-Frame-Rate Color Doppler Using Dual-Wavelength Processing
Doppler ultrasound is the premier modality to analyze blood flow dynamics in clinical practice. With conventional systems, Doppler can either provide a time-resolved quantification of the flow dynamics in sample volumes (spectral Doppler) or an average Doppler velocity/power [color flow imaging (CFI)] in a wide field of view (FOV) but with a limited frame rate. The recent development of ultrafast parallel systems made it possible to evaluate simultaneously color, power, and spectral Doppler in a wide FOV and at high-frame rates but at the expense of signal-to-noise ratio (SNR). However, like conventional Doppler, ultrafast Doppler is subject to aliasing for large velocities and/or large depths. In a recent study, staggered multi-pulse repetition frequency (PRF) sequences were investigated to dealias color-Doppler images. In this work, we exploit the broadband nature of pulse-echo ultrasound and propose a dual-wavelength approach for CFI dealiasing with a constant PRF. We tested the dual-wavelength bandpass processing, in silico, in laminar flow phantom and validated it in vivo in human carotid arteries ( n = 25). The in silico results showed that the Nyquist velocity could be extended up to four times the theoretical limit. In vivo, dealiased CFI were highly consistent with unfolded Spectral Doppler ( r 2 =0.83, y=1.1x+0.1, N=25) and provided consistent vector flow images. Our results demonstrate that dual-wavelength processing is an efficient method for high-velocity CFI.
- 3 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (6) , 2117-2128
Dealiasing High-Frame-Rate Color Doppler Using Dual-Wavelength Processing
Doppler ultrasound is the premier modality to analyze blood flow dynamics in clinical practice. With conventional systems, Doppler can either provide a time-resolved quantification of the flow dynamics in sample volumes (spectral Doppler) or an average Doppler velocity/power [color flow imaging (CFI)] in a wide field of view (FOV) but with a limited frame rate. The recent development of ultrafast parallel systems made it possible to evaluate simultaneously color, power, and spectral Doppler in a wide FOV and at high-frame rates but at the expense of signal-to-noise ratio (SNR). However, like conventional Doppler, ultrafast Doppler is subject to aliasing for large velocities and/or large depths. In a recent study, staggered multi-pulse repetition frequency (PRF) sequences were investigated to dealias color-Doppler images. In this work, we exploit the broadband nature of pulse-echo ultrasound and propose a dual-wavelength approach for CFI dealiasing with a constant PRF. We tested the dual-wavelength bandpass processing, in silico, in laminar flow phantom and validated it in vivo in human carotid arteries ( n = 25). The in silico results showed that the Nyquist velocity could be extended up to four times the theoretical limit. In vivo, dealiased CFI were highly consistent with unfolded Spectral Doppler ( r 2 =0.83, y=1.1x+0.1, N=25) and provided consistent vector flow images. Our results demonstrate that dual-wavelength processing is an efficient method for high-velocity CFI.