ELEmeline Laborie

Emeline Laborie

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Emeline Laborie has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development of an in-silico multi-scale framework to simulate mucociliary clearance

    by Émeline Laborie

    Développement d'un modèle multi-échelle in-silico pour simuler la clairance mucociliaire: Dans les voies respiratoires, la moitié de la surface épithéliale est couverte de cils. Les cils sont des filaments motiles ressemblant à des poils animés d'un mouvement de battement périodique et asymétrique. Ils sont en grande partie immergés dans une couche de fluide semblable à de l'eau, appelée la couche périciliaire et sont couverts d'une seconde couche de fluide visqueux appelée le mucus. Leur mouvement de battement leur permet de pousser sur la couche de mucus, et ce faisant, de débarrasser la trachée des poussières et pathogènes piégés à l'intérieur. Ce processus s'appelle la clairance mucociliaire et constitue le premier mécanisme de défense des voies respiratoires contre les particules potentiellement nocives inhalées. De ce fait, tout dysfonctionnement de l'un des composants de ce mécanisme, notamment des cils ou du mucus, est à l'origine de maladies respiratoires innées comme la Dyskinésie Ciliaire Primitive (DCP), ou acquises comme la COVID-19. Dans notre travail, nous utilisons la méthode de Boltzmann sur réseau couplée à la Dynamique Moléculaire pour étudier l'efficacité de la clairance mucociliaire. Nous commençons par implémenter et optimiser un modèle phénoménologique des cils basé sur un réseau élastique, et un modèle explicite de la couche de mucus, à l'échelle mésoscopique, paramétrés pour reproduire des conditions de santé normale. Ensuite, nous étudions l'influence d'un placement irrégulier des cellules ciliées sur la surface épithéliale ou d'une distribution désordonnée de leurs directions de battement, sur la coordination du battement des cils, la dynamique du fluide environnant et la clairance du mucus. Finalement, nous introduisons des défauts dans le tapis de cils afin d'émuler des caractéristiques pathologiques. Nous examinons comment la réduction de la surface ciliée ou l'immotilité de certaines cellules ciliées, reproduisant respectivement les effets d'une infection virale ou de la DCP, affectent l'efficacité du transport de mucus.

  • Open Access

    Power-law decay of force on cell membrane tethers reflects long-ranged relaxation of membrane tension

    by Emeline Laborie, Andrew Callan-Jones

    Membrane tension is an acknowledged regulator of a wide array of cell functions; however, whether it acts locally or globally in different contexts remains debated. Recent experiments that locally perturb tension and measure the response elsewhere on the membrane are not conclusive, and the mechanism of diffusive tension relaxation has been called into doubt. Here, we consider the tension response to a sudden extension of a membrane tether, and report a quantitative signature of dynamic tension relaxation, which up to now is missing. We present a theory based on tension diffusion leading to a prediction of power-law decay in time of the force holding the tether, with a material-independent exponent of 1 / 3. This prediction is confirmed to within a few percent by re-analyzing eleven sets of tether data from two cell types with distinct membrane cortical architectures. Overall, our scaling results indicate the absence of a relevant characteristic length and therefore generically reflect tension relaxation by long-range membrane lipid flows.


  • An operative framework to model mucus clearance in silico by coupling cilia motion with the liquid environment

    by Emeline Laborie, Simone Melchionna, Fabio Sterpone

    Mucociliary clearance is the first defense mechanism of the respiratory tract against inhaled particles. This mechanism is based on the collective beating motion of cilia at the surface of epithelial cells. Impaired clearance, either caused by malfunctioning or absent cilia, or mucus defects is a symptom of many respiratory diseases. Here, by exploiting the Lattice Boltzmann particle dynamics technique, we develop a model to simulate the dynamics of multiciliated cells in a two-layer fluid. Firstly, we tuned our model to reproduce the characteristic length- and time-scales of the cilia beating. We then check for the emergence of the metachronal wave as a consequence of hydrodynamic mediated correlations between beating cilia. Finally we tune the viscosity of the top fluid layer to simulate the mucus flow upon cilia beating, and evaluate the pushing efficiency of a carpet of cilia. With this work, we build a realistic framework that can be used to go explore several important physiological aspects of mucoliary clearance.


  • Open Access

    Exposure of Von Willebrand Factor Cleavage Site in A1A2A3-Fragment under Extreme Hydrodynamic Shear

    by Olivier Languin-Cattoën, Emeline Laborie, Daria O. Yurkova, Simone Melchionna, Philippe Derreumaux, Aleksey V. Belyaev, Fabio Sterpone

    Von Willebrand Factor (vWf) is a giant multimeric extracellular blood plasma involved in hemostasis. In this work we present multi-scale simulations of its three-domains fragment A1A2A3. These three domains are essential for the functional regulation of vWf. Namely the A2 domain hosts the site where the protease ADAMTS13 cleavages the multimeric vWf allowing for its length control that prevents thrombotic conditions. The exposure of the cleavage site follows the elongation/unfolding of the domain that is caused by an increased shear stress in blood. By deploying Lattice Boltzmann molecular dynamics simulations based on the OPEP coarse-grained model for proteins, we investigated at molecular level the unfolding of the A2 domain under the action of a perturbing shear flow. We described the structural steps of this unfolding that mainly concerns the β-strand structures of the domain, and we compared the process occurring under shear with that produced by the action of a directional pulling force, a typical condition of single molecule experiments. We observe, that under the action of shear flow, the competition among the elongational and rotational components of the fluid field leads to a complex behaviour of the domain, where elongated structures can be followed by partially collapsed melted globule structures with a very different degree of exposure of the cleavage site. Our simulations pose the base for the development of a multi-scale in-silico description of vWf dynamics and functionality in physiological conditions, including high resolution details for molecular relevant events, e.g., the binding to platelets and collagen during coagulation or thrombosis.


  • Dealiasing High-Frame-Rate Color Doppler Using Dual-Wavelength Processing

    by Jonathan Poree, Guillaume Goudot, Olivier Pedreira, Emeline Laborie, Lina Khider, Tristan Mirault, Emmanuel Messas, Pierre Julia, Jean-Marc Alsac, Mickael Tanter, et al.

    Doppler ultrasound is the premier modality to analyze blood flow dynamics in clinical practice. With conventional systems, Doppler can either provide a time-resolved quantification of the flow dynamics in sample volumes (spectral Doppler) or an average Doppler velocity/power [color flow imaging (CFI)] in a wide field of view (FOV) but with a limited frame rate. The recent development of ultrafast parallel systems made it possible to evaluate simultaneously color, power, and spectral Doppler in a wide FOV and at high-frame rates but at the expense of signal-to-noise ratio (SNR). However, like conventional Doppler, ultrafast Doppler is subject to aliasing for large velocities and/or large depths. In a recent study, staggered multi-pulse repetition frequency (PRF) sequences were investigated to dealias color-Doppler images. In this work, we exploit the broadband nature of pulse-echo ultrasound and propose a dual-wavelength approach for CFI dealiasing with a constant PRF. We tested the dual-wavelength bandpass processing, in silico, in laminar flow phantom and validated it in vivo in human carotid arteries ( n = 25). The in silico results showed that the Nyquist velocity could be extended up to four times the theoretical limit. In vivo, dealiased CFI were highly consistent with unfolded Spectral Doppler ( r 2 =0.83, y=1.1x+0.1, N=25) and provided consistent vector flow images. Our results demonstrate that dual-wavelength processing is an efficient method for high-velocity CFI.