Xueshen Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xueshen Li has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Yu Gan
Stevens Institute of Technology (United States)
5 shared publications - Brigitta C. Brott
University of Alabama at Birmingham, Birmingham, Alabama, USA
2 shared publications - Hongshan Liu
Department of Electrical and Computer Engineering, The University of Alabama, Tuscaloosa, AL, USA
2 shared publications - Silvio Litovsky
Department of Pathology, Division of Pathology, University of Alabama at Birmingham, Birmingham, Alabama
2 shared publications - Xiaoyu Song
Centre for Quantitative Medicine, Duke-NUS Medical School, Singapore
2 shared publications - Xinlong Hou
Department of Biomedical Engineering, Stevens Institute of Technology, Hoboken, New Jersey, USA
2 shared publications
Latest Publications
- Open Access
- 16 November 2026
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Computing for Healthcare
- Vol. 8 (1) , 1-20
Diagnostic Report Generation via a ProActive Multimodal Agentic System
Automated diagnostic report generation lies at the core of clinical diagnosis and can alleviate clinician shortages. Existing diagnostic report generation methods have two major limitations: they rely on unimodal inputs (e.g., images), ignoring textual biomarkers like medical history, and lack proactive dialogue capabilities to elicit personalized clinical information. To address those issues, we propose a ProActive Multimodal Agentic (PAMA) system, which performs a comprehensive disease analysis by examining biomarkers in diverse sources, including multi-view medical images, medical histories, and diagnostic conversations. Built upon a knowledge graph and recommendation-based dialogue architecture, PAMA actively initiates adaptive, multi-turn conversations with patients, which is integrated with visual data for robust and reliable report generation. Specifically, PAMA actively generates adaptive multi-turn questions to collect clinically relevant background information and then fuses the resulting dialogue context with visual representations for robust diagnostic report generation. We validate our approach on two real-world benchmark datasets, MIMIC-CXR and IU-X-ray, through extensive quantitative evaluations and comparisons with state-of-the-art baselines. Furthermore, we conduct user studies to assess the realism and clinical quality of the generated reports. Finally, we present real-world case studies to examine the performance of our system across diverse scenarios, demonstrating its robustness on scalability, complexity, and data variability.
- 16 November 2026
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Computing for Healthcare
- Vol. 8 (1) , 1-20
Open AccessDiagnostic Report Generation via a ProActive Multimodal Agentic System
Automated diagnostic report generation lies at the core of clinical diagnosis and can alleviate clinician shortages. Existing diagnostic report generation methods have two major limitations: they rely on unimodal inputs (e.g., images), ignoring textual biomarkers like medical history, and lack proactive dialogue capabilities to elicit personalized clinical information. To address those issues, we propose a ProActive Multimodal Agentic (PAMA) system, which performs a comprehensive disease analysis by examining biomarkers in diverse sources, including multi-view medical images, medical histories, and diagnostic conversations. Built upon a knowledge graph and recommendation-based dialogue architecture, PAMA actively initiates adaptive, multi-turn conversations with patients, which is integrated with visual data for robust and reliable report generation. Specifically, PAMA actively generates adaptive multi-turn questions to collect clinically relevant background information and then fuses the resulting dialogue context with visual representations for robust diagnostic report generation. We validate our approach on two real-world benchmark datasets, MIMIC-CXR and IU-X-ray, through extensive quantitative evaluations and comparisons with state-of-the-art baselines. Furthermore, we conduct user studies to assess the realism and clinical quality of the generated reports. Finally, we present real-world case studies to examine the performance of our system across diverse scenarios, demonstrating its robustness on scalability, complexity, and data variability.
- Open Access
Towards reliable calcification detection: calibration of uncertainty in coronary optical coherence tomography images
Optical coherence tomography (OCT) has become increasingly essential in assisting the treatment of coronary artery disease (CAD). Image-guided solutions such as Percutaneous Coronary Intervention (PCI) are extensively used during the treatment of CAD. However, unidentified calcified regions within a narrowed artery could impair the outcome of the PCI. Prior to treatments, object detection is paramount to automatically procure accurate readings on the location and thickness of calcifications within the artery. Deep learning-based object detection methods have been explored in a variety of applications. The quality of object detection predictions could lead to uncertain results, which are not desirable in safety-critical scenarios. In this work, we implement an object detection model, You-Only-Look-Once v5 (YOLO), on a calcification detection framework within coronary OCT images. We evaluate the uncertainty of predictions based on the expected calibration errors, thus assessing the certainty level of detection results. To calibrate confidence scores of predictions, we implement dependent logistic calibration using each detection result's confidence and center coordinates. With the calibrated confidence score of each prediction, we lower the uncertainty of predictions in calcification detection. Our results show that the YOLO achieves higher precision and recall in comparison with the other object detection model, meanwhile producing more reliable results. The calibrated confidence of prediction results in a confidence error of approximately 0.13, suggesting that the confidence calibration on calcification detection could provide a more trustworthy result, indicating a great potential to assist clinical evaluation of treating the CAD during the imaging-guided procedure.
Open AccessTowards reliable calcification detection: calibration of uncertainty in coronary optical coherence tomography images
Optical coherence tomography (OCT) has become increasingly essential in assisting the treatment of coronary artery disease (CAD). Image-guided solutions such as Percutaneous Coronary Intervention (PCI) are extensively used during the treatment of CAD. However, unidentified calcified regions within a narrowed artery could impair the outcome of the PCI. Prior to treatments, object detection is paramount to automatically procure accurate readings on the location and thickness of calcifications within the artery. Deep learning-based object detection methods have been explored in a variety of applications. The quality of object detection predictions could lead to uncertain results, which are not desirable in safety-critical scenarios. In this work, we implement an object detection model, You-Only-Look-Once v5 (YOLO), on a calcification detection framework within coronary OCT images. We evaluate the uncertainty of predictions based on the expected calibration errors, thus assessing the certainty level of detection results. To calibrate confidence scores of predictions, we implement dependent logistic calibration using each detection result's confidence and center coordinates. With the calibrated confidence score of each prediction, we lower the uncertainty of predictions in calcification detection. Our results show that the YOLO achieves higher precision and recall in comparison with the other object detection model, meanwhile producing more reliable results. The calibrated confidence of prediction results in a confidence error of approximately 0.13, suggesting that the confidence calibration on calcification detection could provide a more trustworthy result, indicating a great potential to assist clinical evaluation of treating the CAD during the imaging-guided procedure.
- 20 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (12) , 3667-3677
Multi-Scale Reconstruction of Undersampled Spectral-Spatial OCT Data for Coronary Imaging Using Deep Learning
Coronary artery disease (CAD) is a cardiovascular condition with high morbidity and mortality. Intravascular optical coherence tomography (IVOCT) has been considered as an optimal imagining system for the diagnosis and treatment of CAD. Constrained by Nyquist theorem, dense sampling in IVOCT attains high resolving power to delineate cellular structures/features. There is a trade-off between high spatial resolution and fast scanning rate for coronary imaging. In this paper, we propose a viable spectral-spatial acquisition method that down-scales the sampling process in both spectral and spatial domain while maintaining high quality in image reconstruction. The down-scaling schedule boosts data acquisition speed without any hardware modifications. Additionally, we propose a unified multi-scale reconstruction framework, namely Multiscale-Spectral-Spatial-Magnification Network (MSSMN), to resolve highly down-scaled (compressed) OCT images with flexible magnification factors. We incorporate the proposed methods into Spectral Domain OCT (SD-OCT) imaging of human coronary samples with clinical features such as stent and calcified lesions. Our experimental results demonstrate that spectral-spatial down-scaled data can be better reconstructed than data that are down-scaled solely in either spectral or spatial domain. Moreover, we observe better reconstruction performance using MSSMN than using existing reconstruction methods. Our acquisition method and multi-scale reconstruction framework, in combination, may allow faster SD-OCT inspection with high resolution during coronary intervention.
- 20 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (12) , 3667-3677
Multi-Scale Reconstruction of Undersampled Spectral-Spatial OCT Data for Coronary Imaging Using Deep Learning
Coronary artery disease (CAD) is a cardiovascular condition with high morbidity and mortality. Intravascular optical coherence tomography (IVOCT) has been considered as an optimal imagining system for the diagnosis and treatment of CAD. Constrained by Nyquist theorem, dense sampling in IVOCT attains high resolving power to delineate cellular structures/features. There is a trade-off between high spatial resolution and fast scanning rate for coronary imaging. In this paper, we propose a viable spectral-spatial acquisition method that down-scales the sampling process in both spectral and spatial domain while maintaining high quality in image reconstruction. The down-scaling schedule boosts data acquisition speed without any hardware modifications. Additionally, we propose a unified multi-scale reconstruction framework, namely Multiscale-Spectral-Spatial-Magnification Network (MSSMN), to resolve highly down-scaled (compressed) OCT images with flexible magnification factors. We incorporate the proposed methods into Spectral Domain OCT (SD-OCT) imaging of human coronary samples with clinical features such as stent and calcified lesions. Our experimental results demonstrate that spectral-spatial down-scaled data can be better reconstructed than data that are down-scaled solely in either spectral or spatial domain. Moreover, we observe better reconstruction performance using MSSMN than using existing reconstruction methods. Our acquisition method and multi-scale reconstruction framework, in combination, may allow faster SD-OCT inspection with high resolution during coronary intervention.
- 16 March 2018
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 6 (6) , 1503-1516
Hybrid MoSe2–indocyanine green nanosheets as a highly efficient phototheranostic agent for photoacoustic imaging guided photothermal cancer therapy
The synthesis of sMoSe2–ICG NSs for highly efficient tumor photoacoustic imaging guided photothermal therapy.
- 16 March 2018
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 6 (6) , 1503-1516
Hybrid MoSe2–indocyanine green nanosheets as a highly efficient phototheranostic agent for photoacoustic imaging guided photothermal cancer therapy
The synthesis of sMoSe2–ICG NSs for highly efficient tumor photoacoustic imaging guided photothermal therapy.