Dilek Tağtekin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dilek Tağtekin has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
- Elif Alkan
Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Türkiye
22 shared publications - Bora Korkut
Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkey
20 shared publications - Funda Yanıkoğlu
Istanbul Kent University
10 shared publications - Ahmad Bittar
Department of Restorative Dentistry, Faculty of Dentistry, İstinye University, İstanbul, Turkiye
6 shared publications - Pınar Yılmaz Atalı
Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkey
6 shared publications - Özlem Kanar
Marmara University, İstanbul, Türkiye
6 shared publications
Latest Publications
- Open Access
- 3 November 2026
- Published by Springer Nature in BMC Oral Health
The effect of selective carious lesion removal on gap formation and bond strength of bioactive restorations
- 3 November 2026
- Published by Springer Nature in BMC Oral Health
Open AccessThe effect of selective carious lesion removal on gap formation and bond strength of bioactive restorations
- 30 October 2026
- Published by Marmara University in Clinical and Experimental Health Sciences
- No. Advanced O,p. 556-562
Effects of Surface Pretreatment and Repair Composite Type on Bond Strength of a 3D-Printed Permanent Resin
Objectives: To evaluate the effects of surface pretreatment and repair composite type on microtensile repair bond strength (μTBS) to an aged 3D-printed permanent crown resin, with explicit consideration of the printing/post-curing workflow used.Methods: Sixty resin blocks (6 × 6 × 6 mm) were printed from Saremco Crowntec using an Asiga Max printer at 50-μm layer thickness, cleaned with 96% alcohol, and post-cured with Signum HiLite Power for 2 × 180 s before thermocycling (5,000 cycles). Blocks were assigned to three pretreatments: diamond bur roughening plus phosphoric acid cleaning, 53-μm aluminum oxide airborne-particle abrasion, or 30-μm tribochemical silica coating. Each pretreatment was repaired with either a highly filled flowable composite or a conventional microhybrid composite using silane and a self-cured universal adhesive. After an additional 5,000 thermocycles, specimens were sectioned into approximately 1-mm² sticks and tested in tension at 1 mm/min. The printed block was the experimental unit.Results: Bur-treated groups showed the lowest μTBS values (19.88-25.26 MPa). Airborne-particle abrasion groups showed higher values (36.24-42.19 MPa), and surface pretreatment had a significant effect (p < .001). Within the same pretreatment, μTBS did not differ between the highly filled flowable and microhybrid repair composites.Conclusion: Airborne-particle abrasion with aluminum oxide or tribochemical silica coating improved repair bond strength of the tested 3D-printed permanent resin compared with bur roughening. Under the conditions of this study, the highly filled flowable composite performed similarly to the conventional microhybrid composite. These findings are specific to the tested resin-printer-cleaning-post-curing workflow and should not be generalized to other permanent printed resins or post-curing units without further validation.
- 30 October 2026
- Published by Marmara University in Clinical and Experimental Health Sciences
- No. Advanced O,p. 556-562
Effects of Surface Pretreatment and Repair Composite Type on Bond Strength of a 3D-Printed Permanent Resin
Objectives: To evaluate the effects of surface pretreatment and repair composite type on microtensile repair bond strength (μTBS) to an aged 3D-printed permanent crown resin, with explicit consideration of the printing/post-curing workflow used.Methods: Sixty resin blocks (6 × 6 × 6 mm) were printed from Saremco Crowntec using an Asiga Max printer at 50-μm layer thickness, cleaned with 96% alcohol, and post-cured with Signum HiLite Power for 2 × 180 s before thermocycling (5,000 cycles). Blocks were assigned to three pretreatments: diamond bur roughening plus phosphoric acid cleaning, 53-μm aluminum oxide airborne-particle abrasion, or 30-μm tribochemical silica coating. Each pretreatment was repaired with either a highly filled flowable composite or a conventional microhybrid composite using silane and a self-cured universal adhesive. After an additional 5,000 thermocycles, specimens were sectioned into approximately 1-mm² sticks and tested in tension at 1 mm/min. The printed block was the experimental unit.Results: Bur-treated groups showed the lowest μTBS values (19.88-25.26 MPa). Airborne-particle abrasion groups showed higher values (36.24-42.19 MPa), and surface pretreatment had a significant effect (p < .001). Within the same pretreatment, μTBS did not differ between the highly filled flowable and microhybrid repair composites.Conclusion: Airborne-particle abrasion with aluminum oxide or tribochemical silica coating improved repair bond strength of the tested 3D-printed permanent resin compared with bur roughening. Under the conditions of this study, the highly filled flowable composite performed similarly to the conventional microhybrid composite. These findings are specific to the tested resin-printer-cleaning-post-curing workflow and should not be generalized to other permanent printed resins or post-curing units without further validation.
- 13 October 2026
- Published by Springer Nature in Odontology
- p. 1-7
Effect of air-abrasion and air-polishing powders on dentin hydraulic conductance before and after acid challenge
Air-polishing and air-abrasion powders may contact exposed dentin, but their effects on fluid transport after acid exposure remain unclear. This in vitro study compared hydraulic conductance before and after powder application and acid challenge. Forty-two 1.0-mm coronal dentin discs were allocated (n = 7/group) to calcium sodium phosphosilicate bioactive glass (Sylc Powder), silica-coated aluminum oxide (CoSil Powder), sodium bicarbonate (AquaCare Sodium Bicarbonate), erythritol with 0.3% chlorhexidine (AIRFLOW PLUS Powder), sodium bicarbonate (AIRFLOW CLASSIC Powder), or untreated control. After 6% citric-acid conditioning for 10 min, baseline conductance was measured. Powders were applied for 15 s, and conductance was measured immediately. After 2% citric acid for 2 min, conductance was remeasured immediately. At 3 psi, 50-µL water transit was normalized to exposed area and pressure and expressed as µL·min⁻¹·cm⁻²·cmH₂O⁻¹. Data were analyzed by two-way mixed repeated-measures analysis of variance, stage-specific Tukey comparisons, and two-sided paired t tests with Holm adjustment. Stage (F(2, 72) = 117.95, p < 0.001) and the group-by-stage interaction (F(10, 72) = 11.77, p < 0.001) were significant. Conductance decreased from baseline in all five active groups (Holm-adjusted p ≤ 0.003) but not in the control (p = 0.681). After acid challenge, Sylc Powder remained lower than all other groups (p ≤ 0.014). Scanning electron microscopy provided illustrative morphology. Under this 15-s application and 2-min challenge protocol, responses depended on powder and stage; bioactive glass produced the most persistent reduction, whereas the other powders returned toward baseline.
- 13 October 2026
- Published by Springer Nature in Odontology
- p. 1-7
Effect of air-abrasion and air-polishing powders on dentin hydraulic conductance before and after acid challenge
Air-polishing and air-abrasion powders may contact exposed dentin, but their effects on fluid transport after acid exposure remain unclear. This in vitro study compared hydraulic conductance before and after powder application and acid challenge. Forty-two 1.0-mm coronal dentin discs were allocated (n = 7/group) to calcium sodium phosphosilicate bioactive glass (Sylc Powder), silica-coated aluminum oxide (CoSil Powder), sodium bicarbonate (AquaCare Sodium Bicarbonate), erythritol with 0.3% chlorhexidine (AIRFLOW PLUS Powder), sodium bicarbonate (AIRFLOW CLASSIC Powder), or untreated control. After 6% citric-acid conditioning for 10 min, baseline conductance was measured. Powders were applied for 15 s, and conductance was measured immediately. After 2% citric acid for 2 min, conductance was remeasured immediately. At 3 psi, 50-µL water transit was normalized to exposed area and pressure and expressed as µL·min⁻¹·cm⁻²·cmH₂O⁻¹. Data were analyzed by two-way mixed repeated-measures analysis of variance, stage-specific Tukey comparisons, and two-sided paired t tests with Holm adjustment. Stage (F(2, 72) = 117.95, p < 0.001) and the group-by-stage interaction (F(10, 72) = 11.77, p < 0.001) were significant. Conductance decreased from baseline in all five active groups (Holm-adjusted p ≤ 0.003) but not in the control (p = 0.681). After acid challenge, Sylc Powder remained lower than all other groups (p ≤ 0.014). Scanning electron microscopy provided illustrative morphology. Under this 15-s application and 2-min challenge protocol, responses depended on powder and stage; bioactive glass produced the most persistent reduction, whereas the other powders returned toward baseline.
- 1 October 2026
- Published by Marmara University in Clinical and Experimental Health Sciences
- Vol. 16 (3) , 505-513
Diagnostic accuracy of short-wave infrared imaging (>1000 nm) for proximal coronal caries detection in human teeth: a systematic review
Objective: To synthesise diagnostic-accuracy evidence for short-wave infrared (SWIR) imaging at wavelengths >1000 nm in primary proximal coronal caries detection in human teeth.Methods: PubMed/MEDLINE and Scopus were exported on 9 April 2026, Web of Science Core Collection on 10 April 2026, and the Cochrane Central Register of Controlled Trials (CENTRAL) was checked on 10 April 2026. Citation chasing supplemented database searching. Both in vivo and in vitro studies were eligible. Eligible studies evaluated SWIR transillumination, reflectance, or combined approaches. Classical diagnostic-accuracy studies formed the core synthesis; lesion-depth, wavelength-optimisation, and lesion-positive clinical studies were retained narratively. Risk of bias was appraised with an adapted Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) framework.Results: Searches yielded 171 records. After duplicate removal from the exported set, 68 unique records were screened, 23 reports were assessed, 13 were excluded, and 10 studies met broader SWIR eligibility. Six studies contributed core diagnostic-accuracy evidence. SWIR methods were generally more sensitive than bitewing radiography, but specificity varied by wavelength and imaging geometry. No study was low risk of bias overall, and probable study-family overlap prevented meta-analysis.Conclusion: SWIR imaging is promising, but it is not a single homogeneous test. Current evidence supports separate interpretation of transillumination and reflectance, cautious clinical translation, and larger independent human validation studies.
- 1 October 2026
- Published by Marmara University in Clinical and Experimental Health Sciences
- Vol. 16 (3) , 505-513
Diagnostic accuracy of short-wave infrared imaging (>1000 nm) for proximal coronal caries detection in human teeth: a systematic review
Objective: To synthesise diagnostic-accuracy evidence for short-wave infrared (SWIR) imaging at wavelengths >1000 nm in primary proximal coronal caries detection in human teeth.Methods: PubMed/MEDLINE and Scopus were exported on 9 April 2026, Web of Science Core Collection on 10 April 2026, and the Cochrane Central Register of Controlled Trials (CENTRAL) was checked on 10 April 2026. Citation chasing supplemented database searching. Both in vivo and in vitro studies were eligible. Eligible studies evaluated SWIR transillumination, reflectance, or combined approaches. Classical diagnostic-accuracy studies formed the core synthesis; lesion-depth, wavelength-optimisation, and lesion-positive clinical studies were retained narratively. Risk of bias was appraised with an adapted Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) framework.Results: Searches yielded 171 records. After duplicate removal from the exported set, 68 unique records were screened, 23 reports were assessed, 13 were excluded, and 10 studies met broader SWIR eligibility. Six studies contributed core diagnostic-accuracy evidence. SWIR methods were generally more sensitive than bitewing radiography, but specificity varied by wavelength and imaging geometry. No study was low risk of bias overall, and probable study-family overlap prevented meta-analysis.Conclusion: SWIR imaging is promising, but it is not a single homogeneous test. Current evidence supports separate interpretation of transillumination and reflectance, cautious clinical translation, and larger independent human validation studies.
- 26 September 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (10) , 473
Fluorescence compatibility of various resin composites on cervical restorations: An in-vitro evaluation
- 26 September 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (10) , 473
Fluorescence compatibility of various resin composites on cervical restorations: An in-vitro evaluation
- Open Access
- 19 September 2026
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 9 (5) , 1328-1333
Twenty-four-hour optical response of demineralized enamel to glycerol-stabilized calcium phosphate: an in vitro fluorescence study
Aims: To compare 24-hour changes in quantitative light-induced fluorescence (QLF)-derived optical outcomes in artificially demineralized human enamel treated with glycerol-stabilized calcium phosphate (GCPC) or artificial saliva.Methods: Artificial enamel lesions were produced using a calcium/phosphate/fluoride-containing acetate-buffered demineralization solution (pH 4.7) for 72 hours. Forty-two enamel blocks were allocated to GCPC or artificial saliva (n=21 per group). QLF images were obtained at baseline (T0) and 24 hours (T24). Outcomes were maximum fluorescence loss (ΔFmax), integrated fluorescence loss (ΔQ), and software-mapped lesion area. ΔFmax was analyzed with t tests; ΔQ and lesion area were analyzed with nonparametric tests.Results: Mean ΔFmax change was +3.58±1.32% with GCPC and +0.67±1.52% with artificial saliva; the between-group mean difference was 2.91 percentage points (95% confidence interval, 2.02 to 3.80; Hedges g=2.01; p
- 19 September 2026
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 9 (5) , 1328-1333
Open AccessTwenty-four-hour optical response of demineralized enamel to glycerol-stabilized calcium phosphate: an in vitro fluorescence study
Aims: To compare 24-hour changes in quantitative light-induced fluorescence (QLF)-derived optical outcomes in artificially demineralized human enamel treated with glycerol-stabilized calcium phosphate (GCPC) or artificial saliva.Methods: Artificial enamel lesions were produced using a calcium/phosphate/fluoride-containing acetate-buffered demineralization solution (pH 4.7) for 72 hours. Forty-two enamel blocks were allocated to GCPC or artificial saliva (n=21 per group). QLF images were obtained at baseline (T0) and 24 hours (T24). Outcomes were maximum fluorescence loss (ΔFmax), integrated fluorescence loss (ΔQ), and software-mapped lesion area. ΔFmax was analyzed with t tests; ΔQ and lesion area were analyzed with nonparametric tests.Results: Mean ΔFmax change was +3.58±1.32% with GCPC and +0.67±1.52% with artificial saliva; the between-group mean difference was 2.91 percentage points (95% confidence interval, 2.02 to 3.80; Hedges g=2.01; p
- Open Access
- 20 July 2026
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 9 (4) , 1018-1023
Interincisal distance and patient-reported tolerability of adjunctive caries detection methods: a cross-sectional questionnaire study
Aims: To evaluate patient-reported comfort, gag reflex, and examination time across visual-tactile and adjunctive caries detection approaches, and to determine whether these outcomes differ according to interincisal distance.Methods: Adults aged 18-60 years attending routine visits between November 5, 2025 and February 5, 2026 underwent visual-tactile examination using the International Caries Detection and Assessment System II and 4 adjunctive methods: DIAGNOdent Pen (KaVo Dental GmbH, Biberach, Germany), QrayPen (AIOBIO, Seoul, Republic of Korea), QrayCam Pro (AIOBIO, Seoul, Republic of Korea), and iTero Element 5D (Align Technology, San Jose, CA, USA). Visual-tactile examination was performed first; adjunctive methods were applied in 2 counterbalanced randomized sequences. Maximum interincisal distance was categorized as ≤3,5 cm, 3,6-5,0 cm, or >5,0 cm. Comfort and gag reflex were rated on 3-point ordinal scales and quadrant examination time was categorized into 4 levels. Nonparametric tests were used.Results: Ninety-six participants were analyzed (mean age, 22,4 years). Outcomes did not differ by randomized sequence. Lower interincisal distance was associated with lower comfort and higher gag reflex for all adjunctive methods (all P ≤ ,01) and with longer time categories for QrayCam Pro, QrayPen, iTero Element 5D, and DIAGNOdent Pen (all P ≤ ,01). Across methods, comfort, gag reflex, and time differed (all P < ,001). QrayCam Pro was most frequently preferred (52/96; 54,2%), whereas iTero Element 5D was not selected.Conclusion: Interincisal distance is a practical indicator of patient tolerability and workflow impact when selecting adjunctive caries detection approaches.
- 20 July 2026
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 9 (4) , 1018-1023
Open AccessInterincisal distance and patient-reported tolerability of adjunctive caries detection methods: a cross-sectional questionnaire study
Aims: To evaluate patient-reported comfort, gag reflex, and examination time across visual-tactile and adjunctive caries detection approaches, and to determine whether these outcomes differ according to interincisal distance.Methods: Adults aged 18-60 years attending routine visits between November 5, 2025 and February 5, 2026 underwent visual-tactile examination using the International Caries Detection and Assessment System II and 4 adjunctive methods: DIAGNOdent Pen (KaVo Dental GmbH, Biberach, Germany), QrayPen (AIOBIO, Seoul, Republic of Korea), QrayCam Pro (AIOBIO, Seoul, Republic of Korea), and iTero Element 5D (Align Technology, San Jose, CA, USA). Visual-tactile examination was performed first; adjunctive methods were applied in 2 counterbalanced randomized sequences. Maximum interincisal distance was categorized as ≤3,5 cm, 3,6-5,0 cm, or >5,0 cm. Comfort and gag reflex were rated on 3-point ordinal scales and quadrant examination time was categorized into 4 levels. Nonparametric tests were used.Results: Ninety-six participants were analyzed (mean age, 22,4 years). Outcomes did not differ by randomized sequence. Lower interincisal distance was associated with lower comfort and higher gag reflex for all adjunctive methods (all P ≤ ,01) and with longer time categories for QrayCam Pro, QrayPen, iTero Element 5D, and DIAGNOdent Pen (all P ≤ ,01). Across methods, comfort, gag reflex, and time differed (all P < ,001). QrayCam Pro was most frequently preferred (52/96; 54,2%), whereas iTero Element 5D was not selected.Conclusion: Interincisal distance is a practical indicator of patient tolerability and workflow impact when selecting adjunctive caries detection approaches.
- 1 July 2026
- Published by Cumhuriyet University in Cumhuriyet Dental Journal
- Vol. 29 (2) , 223-230
Diagnostic Performance of QrayCam Pro Fluorescence Imaging with Full-Arch versus Quadrant Field-of-View for Dental Caries
Objectives: To compare the diagnostic performance of quadrant-focused (half-jaw) versus full-arch QLF imaging with QrayCam Pro for occlusal caries detection against a combined ICDAS+bitewing reference.Materials and Methods: Forty-five adults (mean age 25.1 years) each contributed one occlusal surface (sound or carious). Each surface was imaged under two protocols: quadrant-focused and full-arch. Q-ray Clinical software yielded ΔF_max (green fluorescence loss), ΔR_max (red fluorescence change), and QS scores. Diagnostic accuracy (sensitivity, specificity, area under the ROC curve [AUC]) was calculated versus the reference standard; protocol differences were assessed with MANOVA.Results: Both protocols showed high performance. For ΔR_max, both achieved AUC = 1.000 with 100% sensitivity and specificity. For ΔF_max, quadrant imaging achieved AUC = 1.000; full-arch had AUC = 0.993 (sensitivity 92.3%, specificity 94.7%). MANOVA found no significant overall difference between protocols (p = 0.790). Quadrant imaging tended to identify early enamel lesions more often.Conclusions: Quadrant-focused QLF imaging offers a small sensitivity advantage for incipient lesions while maintaining high specificity; full-arch imaging remains efficient for screening and documentation. Protocol choice can be tailored to early-lesion detection needs and AI-based analysis workflows.
- 1 July 2026
- Published by Cumhuriyet University in Cumhuriyet Dental Journal
- Vol. 29 (2) , 223-230
Diagnostic Performance of QrayCam Pro Fluorescence Imaging with Full-Arch versus Quadrant Field-of-View for Dental Caries
Objectives: To compare the diagnostic performance of quadrant-focused (half-jaw) versus full-arch QLF imaging with QrayCam Pro for occlusal caries detection against a combined ICDAS+bitewing reference.Materials and Methods: Forty-five adults (mean age 25.1 years) each contributed one occlusal surface (sound or carious). Each surface was imaged under two protocols: quadrant-focused and full-arch. Q-ray Clinical software yielded ΔF_max (green fluorescence loss), ΔR_max (red fluorescence change), and QS scores. Diagnostic accuracy (sensitivity, specificity, area under the ROC curve [AUC]) was calculated versus the reference standard; protocol differences were assessed with MANOVA.Results: Both protocols showed high performance. For ΔR_max, both achieved AUC = 1.000 with 100% sensitivity and specificity. For ΔF_max, quadrant imaging achieved AUC = 1.000; full-arch had AUC = 0.993 (sensitivity 92.3%, specificity 94.7%). MANOVA found no significant overall difference between protocols (p = 0.790). Quadrant imaging tended to identify early enamel lesions more often.Conclusions: Quadrant-focused QLF imaging offers a small sensitivity advantage for incipient lesions while maintaining high specificity; full-arch imaging remains efficient for screening and documentation. Protocol choice can be tailored to early-lesion detection needs and AI-based analysis workflows.
- 21 May 2026
- Published by Wiley in Orthodontics & Craniofacial Research
- Vol. 29 (4) , 789-800
Effect of Staining and Cleaning Agents on the Colour Stability and Surface Roughness of Clear Aligners
Aim: This study aimed to evaluate the effects of various staining and cleaning agents on the colour stability and surface roughness of Invisalign aligners (Align Technology). Materials and Methods: 240 aligners were assigned to five staining groups (coffee, black tea, cola, red wine and distilled water). They were immersed daily for 15 min over 3 times per day. Each group was divided into six cleaning subgroups (Corexyl, Cleaning Crystals, Corega ProGuard, Corega, Toothpaste and distilled water). After 7 days, colour change and surface roughness were assessed from multiple regions using a spectrophotometer and profilometer. Regional measurements from the same aligner were averaged to obtain one representative value per aligner. Robust Two‐Way ANOVA tested the effects of staining and cleaning agents. Results: Staining agents significantly affected colour change ( p < 0.001). Coffee caused the greatest discoloration, followed by tea and wine, while cola showed the lowest staining potential. All staining agents induced perceptible colour changes (∆ E 00 > 1.8). Cleaning agents also significantly influenced colour change ( p = 0.001). Corexyl and Crystals achieved significantly lower ∆ E 00 values than toothpaste and distilled water. For surface roughness, only staining agents showed a significant effect ( p = 0.001); cleaning agents and staining × cleaning interaction were not significant. Tea and wine produced significant Ra increases compared with distilled water. Conclusions: Aligner discoloration differed according to beverage type, with coffee, tea and wine producing greater changes than cola. Corexyl and Cleaning Crystals showed comparatively favourable colour stability, whereas surface roughness changes were mainly related to staining agents. These findings highlight the multifactorial nature of aligner aesthetic changes.
- 21 May 2026
- Published by Wiley in Orthodontics & Craniofacial Research
- Vol. 29 (4) , 789-800
Effect of Staining and Cleaning Agents on the Colour Stability and Surface Roughness of Clear Aligners
Aim: This study aimed to evaluate the effects of various staining and cleaning agents on the colour stability and surface roughness of Invisalign aligners (Align Technology). Materials and Methods: 240 aligners were assigned to five staining groups (coffee, black tea, cola, red wine and distilled water). They were immersed daily for 15 min over 3 times per day. Each group was divided into six cleaning subgroups (Corexyl, Cleaning Crystals, Corega ProGuard, Corega, Toothpaste and distilled water). After 7 days, colour change and surface roughness were assessed from multiple regions using a spectrophotometer and profilometer. Regional measurements from the same aligner were averaged to obtain one representative value per aligner. Robust Two‐Way ANOVA tested the effects of staining and cleaning agents. Results: Staining agents significantly affected colour change ( p < 0.001). Coffee caused the greatest discoloration, followed by tea and wine, while cola showed the lowest staining potential. All staining agents induced perceptible colour changes (∆ E 00 > 1.8). Cleaning agents also significantly influenced colour change ( p = 0.001). Corexyl and Crystals achieved significantly lower ∆ E 00 values than toothpaste and distilled water. For surface roughness, only staining agents showed a significant effect ( p = 0.001); cleaning agents and staining × cleaning interaction were not significant. Tea and wine produced significant Ra increases compared with distilled water. Conclusions: Aligner discoloration differed according to beverage type, with coffee, tea and wine producing greater changes than cola. Corexyl and Cleaning Crystals showed comparatively favourable colour stability, whereas surface roughness changes were mainly related to staining agents. These findings highlight the multifactorial nature of aligner aesthetic changes.