Yuan Wei
Research Subjects
Yuan Wei has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Han Wang
Graduate School of Biomedical Engineering, UNSW, Sydney, NSW, Australia
4 shared publications- Amr Al Abed
Graduate School of Biomedical Engineering, UNSW, Sydney, NSW, Australia
3 shared publications - François Ladouceur
School of Electrical Engineering and Telecommunications, UNSW, Sydney, Australia
3 shared publications - Josiah Firth
Australian National Fabrication Facility, UNSW 3 , Sydney, NSW 2052, Australia
3 shared publications - Nigel Hamilton Lovell
UNSW Sydney
3 shared publications - Reem M. Almasri
Graduate School of Biomedical Engineering
3 shared publications
Latest Publications
- 2 August 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (17) , 27462-27481
Simultaneous sensing of strain and temperature based on the inline-MZI embedded point-shaped taper structure with low crosstalk
An embedded spherical dot taper structure (EDT) based on the MZI principle is proposed in this paper, which is mainly fabricated by using two special arc discharges in the preparation process. The proposed structure involves two specialized arc discharge techniques. First, an oversaturated discharge fusion process creates a micro-arc spherical area on the fiber end face to form the first link type. Second, an unsaturated discharge-pulling taper fusion joint creates a local micro-extrusion operation on this micro-arc fiber end face to form the second link. The thermal stress from instantaneous discharge causes a reverse spherical expansion zone to form in the end face structure, similar to the micromachining of long-period fiber gratings that use local CO2 laser etching to create modulated zones. The study involves a mathematical and theoretical analysis of how geometric parameters in the spherical modulation zone impact the structure's characteristic spectrum. The research demonstrates the potential for this structure to function as a light-intensity modulated strain sensor device through both theoretical and experimental means. As per the experimental findings, the optimized structure displays a high level of strain sensing sensitivity at 0.03 dB/µε and temperature sensing sensitivity of 73 pm/°C (20°C-75°C) and 169 pm/°C (75°C-120°C). Additionally, it possesses excellent cross-sensitivity at only ∼0.0015 µε/°C. Therefore, this sensor presents a favorable option for strain and temperature synchronization sensing and monitoring components, and exhibits notable application prospects in precision engineering, which encompasses mechanical manufacturing, the power and electrical industry, healthcare domain, and certain specialized areas of small-scale precision engineering.
- 2 August 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (17) , 27462-27481
Simultaneous sensing of strain and temperature based on the inline-MZI embedded point-shaped taper structure with low crosstalk
An embedded spherical dot taper structure (EDT) based on the MZI principle is proposed in this paper, which is mainly fabricated by using two special arc discharges in the preparation process. The proposed structure involves two specialized arc discharge techniques. First, an oversaturated discharge fusion process creates a micro-arc spherical area on the fiber end face to form the first link type. Second, an unsaturated discharge-pulling taper fusion joint creates a local micro-extrusion operation on this micro-arc fiber end face to form the second link. The thermal stress from instantaneous discharge causes a reverse spherical expansion zone to form in the end face structure, similar to the micromachining of long-period fiber gratings that use local CO2 laser etching to create modulated zones. The study involves a mathematical and theoretical analysis of how geometric parameters in the spherical modulation zone impact the structure's characteristic spectrum. The research demonstrates the potential for this structure to function as a light-intensity modulated strain sensor device through both theoretical and experimental means. As per the experimental findings, the optimized structure displays a high level of strain sensing sensitivity at 0.03 dB/µε and temperature sensing sensitivity of 73 pm/°C (20°C-75°C) and 169 pm/°C (75°C-120°C). Additionally, it possesses excellent cross-sensitivity at only ∼0.0015 µε/°C. Therefore, this sensor presents a favorable option for strain and temperature synchronization sensing and monitoring components, and exhibits notable application prospects in precision engineering, which encompasses mechanical manufacturing, the power and electrical industry, healthcare domain, and certain specialized areas of small-scale precision engineering.
- 1 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 41 (13) , 4463-4472
A Bi-Directional Detection and Stimulation Optrode System With Charge Balancing for Neural Applications
The design of a bi-directional optical-electrode or ‘optrode’ for peripheral nerve and brain-machine interfacing is proposed and its principle of operation detailed, which is able to provide biphasic stimulus and charge balancing functionalities. The prototype chip is fabricated, characterised on the bench, and assessed in vivo and ex vivo . Results show that it can simultaneously stimulate and record from the rabbit sciatic nerve, and entrainment of the sino-atrial node is achieved and observed by the prototype. Then, a discrete component circuit is tested for validation of this charge-balancing effect. Experimental results from in vivo testing on rabbit sciatic nerves demonstrate that the voltage generated by photodiodes at around 0.5 to 0.6V is able to evoke compound action potentials, and the activated light-dependent resistor removed more than 80% of the post-stimulus charge stored at the interface.
- 1 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 41 (13) , 4463-4472
A Bi-Directional Detection and Stimulation Optrode System With Charge Balancing for Neural Applications
The design of a bi-directional optical-electrode or ‘optrode’ for peripheral nerve and brain-machine interfacing is proposed and its principle of operation detailed, which is able to provide biphasic stimulus and charge balancing functionalities. The prototype chip is fabricated, characterised on the bench, and assessed in vivo and ex vivo . Results show that it can simultaneously stimulate and record from the rabbit sciatic nerve, and entrainment of the sino-atrial node is achieved and observed by the prototype. Then, a discrete component circuit is tested for validation of this charge-balancing effect. Experimental results from in vivo testing on rabbit sciatic nerves demonstrate that the voltage generated by photodiodes at around 0.5 to 0.6V is able to evoke compound action potentials, and the activated light-dependent resistor removed more than 80% of the post-stimulus charge stored at the interface.
- 1 October 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (5) , 056031
Liquid crystal electro-optical transducers for electrophysiology sensing applications
Objective. Biomedical instrumentation and clinical systems for electrophysiology rely on electrodes and wires for sensing and transmission of bioelectric signals. However, this electronic approach constrains bandwidth, signal conditioning circuit designs, and the number of channels in invasive or miniature devices. This paper demonstrates an alternative approach using light to sense and transmit the electrophysiological signals. Approach. We develop a sensing, passive, fluorophore-free optrode based on the birefringence property of liquid crystals (LCs) operating at the microscale. Main results. We show that these optrodes can have the appropriate linearity ( µ ± s.d.: 99.4 ± 0.5%, n = 11 devices), relative responsivity ( µ ± s.d.: 57 ± 12%V −1 , n = 5 devices), and bandwidth ( µ ± s.d.: 11.1 ± 0.7 kHz, n = 7 devices) for transducing electrophysiology signals into the optical domain. We report capture of rabbit cardiac sinoatrial electrograms and stimulus-evoked compound action potentials from the rabbit sciatic nerve. We also demonstrate miniaturisation potential by fabricating multi-optrode arrays, by developing a process that automatically matches each transducer element area with that of its corresponding biological interface. Significance. Our method of employing LCs to convert bioelectric signals into the optical domain will pave the way for the deployment of high-bandwidth optical telecommunications techniques in ultra-miniature clinical diagnostic and research laboratory neural and cardiac interfaces.
- 1 October 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (5) , 056031
Liquid crystal electro-optical transducers for electrophysiology sensing applications
Objective. Biomedical instrumentation and clinical systems for electrophysiology rely on electrodes and wires for sensing and transmission of bioelectric signals. However, this electronic approach constrains bandwidth, signal conditioning circuit designs, and the number of channels in invasive or miniature devices. This paper demonstrates an alternative approach using light to sense and transmit the electrophysiological signals. Approach. We develop a sensing, passive, fluorophore-free optrode based on the birefringence property of liquid crystals (LCs) operating at the microscale. Main results. We show that these optrodes can have the appropriate linearity ( µ ± s.d.: 99.4 ± 0.5%, n = 11 devices), relative responsivity ( µ ± s.d.: 57 ± 12%V −1 , n = 5 devices), and bandwidth ( µ ± s.d.: 11.1 ± 0.7 kHz, n = 7 devices) for transducing electrophysiology signals into the optical domain. We report capture of rabbit cardiac sinoatrial electrograms and stimulus-evoked compound action potentials from the rabbit sciatic nerve. We also demonstrate miniaturisation potential by fabricating multi-optrode arrays, by developing a process that automatically matches each transducer element area with that of its corresponding biological interface. Significance. Our method of employing LCs to convert bioelectric signals into the optical domain will pave the way for the deployment of high-bandwidth optical telecommunications techniques in ultra-miniature clinical diagnostic and research laboratory neural and cardiac interfaces.
- 10 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (5) , 1674-1684
Impedance Properties of Multi-Optrode Biopotential Sensing Arrays
Recording and monitoring electrically-excitable cells is critical to understanding the complex cellular networking within organs as well as the processes underlying many electro-physiological pathologies. Biopotential recording using an optical-electrode (optrode) is a novel approach which has potential to significantly improve interface-instrumentation impedance mismatching as recording contact-sizes become smaller and smaller. Optrodes incorporate a conductive interface that can sense extracellular potential and an underlying layer of liquid crystals that passively transduces electrical signals into measurable optical signals. This study investigates the impedance properties of this optical technology by varying the diameter of recording sites and observing the corresponding changes in the impedance values. The results show that the liquid crystals in this optrode platform exhibit input impedance values (1 MΩ – 100 GΩ) that are three orders of magnitude higher than the corresponding interface impedance, which is appropriate for voltage sensing. The automatic scaling of the input impedance enabled within the optrode system maintains a relatively constant ratio between input and total system impedance of about one for sensing areas with diameters ranging from 40 µ m to 1 mm, at which the calculated signal loss is predicted to be <1%. This feature preserves the interface-transducer impedance ratio, regardless of the size of the recording site, allowing development of passive optrode arrays capable of very high spatial-resolution recordings.
- 10 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (5) , 1674-1684
Impedance Properties of Multi-Optrode Biopotential Sensing Arrays
Recording and monitoring electrically-excitable cells is critical to understanding the complex cellular networking within organs as well as the processes underlying many electro-physiological pathologies. Biopotential recording using an optical-electrode (optrode) is a novel approach which has potential to significantly improve interface-instrumentation impedance mismatching as recording contact-sizes become smaller and smaller. Optrodes incorporate a conductive interface that can sense extracellular potential and an underlying layer of liquid crystals that passively transduces electrical signals into measurable optical signals. This study investigates the impedance properties of this optical technology by varying the diameter of recording sites and observing the corresponding changes in the impedance values. The results show that the liquid crystals in this optrode platform exhibit input impedance values (1 MΩ – 100 GΩ) that are three orders of magnitude higher than the corresponding interface impedance, which is appropriate for voltage sensing. The automatic scaling of the input impedance enabled within the optrode system maintains a relatively constant ratio between input and total system impedance of about one for sensing areas with diameters ranging from 40 µ m to 1 mm, at which the calculated signal loss is predicted to be <1%. This feature preserves the interface-transducer impedance ratio, regardless of the size of the recording site, allowing development of passive optrode arrays capable of very high spatial-resolution recordings.
- Open Access
- 2 June 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (12) , 18915-18931
Photodiode working in zero-mode: detecting light power change with DC rejection and AC amplification
We propose a new mode of operation when using a photodiode to extract a variable optical signal from a constant (ambient) background. The basic idea of this ‘zero-mode’ of operation is to force the photodiode to operate at either zero current or zero voltage. We present possible implementations of this novel approach and provide the corresponding equivalent circuits while also demonstrating experimentally its performance. The gain and bandwidth of the zero-mode photodetector are measured and simulated, and they show highly agreement. The gain compression effect because of the nonlinearity of the forward bias region is also explored. Comparing to the conventional photoconductive photodetector, the zero-mode photodetector is able to obtain higher AC gain and lower noise. With the same component used in the circuit, the measured input referred root mean square noise of zero-mode photodetector is 4.4mV whereas that of the photoconductive mode photodetector is 96.9mV respectively, showing the feasibility of the zero-mode of operation for measuring the small variable light signal under a high power constant background light.
- 2 June 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (12) , 18915-18931
Open AccessPhotodiode working in zero-mode: detecting light power change with DC rejection and AC amplification
We propose a new mode of operation when using a photodiode to extract a variable optical signal from a constant (ambient) background. The basic idea of this ‘zero-mode’ of operation is to force the photodiode to operate at either zero current or zero voltage. We present possible implementations of this novel approach and provide the corresponding equivalent circuits while also demonstrating experimentally its performance. The gain and bandwidth of the zero-mode photodetector are measured and simulated, and they show highly agreement. The gain compression effect because of the nonlinearity of the forward bias region is also explored. Comparing to the conventional photoconductive photodetector, the zero-mode photodetector is able to obtain higher AC gain and lower noise. With the same component used in the circuit, the measured input referred root mean square noise of zero-mode photodetector is 4.4mV whereas that of the photoconductive mode photodetector is 96.9mV respectively, showing the feasibility of the zero-mode of operation for measuring the small variable light signal under a high power constant background light.