Weidong Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Weidong Shi has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bo Zhang
The Institute of High Voltage and Insulation Technology, Tsinghua University , Beijing 100084
1 shared publication - Qingmin Li
North China Electric Power University
1 shared publication - Wah Hoon Siew
Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow G1 1XW, UK
1 shared publication - Zhuoran Liu
State Key Lab of Power System, Department of Electrical Engineering, Tsinghua University, Beijing, China
1 shared publication - Zixin Guo
China Electric Power Research Institute, Beijing, China
1 shared publication
Latest Publications
- Open Access
On the Lightning Attachment Process of Wind Turbine–Observation, Experiments and Modelling
Wind power plays an increasingly important role in power generation as one of the most popular renewable energy sources. With the increasing capacity and height of wind turbines, lightning incidents have become one of the most serious threats to wind turbines, especially for wind turbine blades. It is important to fully understand the lightning attachment process of a wind turbine, which is not only essential to academic research but also useful to the design of a lightning protection system. Plenty of work has been conducted from three main perspectives: field observations, laboratory experiments, and simulation models. In this paper, the existing research achievements have been reviewed, and problems to be solved have been proposed. The monitoring of lightning incidents on wind farms remains a challenge, and a device to capture lightning strikes to wind turbines with high efficiency is in demand. The impact of sensors on the blade on the lightning protection system cannot be ignored and needs further investigation. For the simulation model, the influence of space charge on the lightning attachment process is not fully understood, and improvements might be made to the existing model.
Open AccessOn the Lightning Attachment Process of Wind Turbine–Observation, Experiments and Modelling
Wind power plays an increasingly important role in power generation as one of the most popular renewable energy sources. With the increasing capacity and height of wind turbines, lightning incidents have become one of the most serious threats to wind turbines, especially for wind turbine blades. It is important to fully understand the lightning attachment process of a wind turbine, which is not only essential to academic research but also useful to the design of a lightning protection system. Plenty of work has been conducted from three main perspectives: field observations, laboratory experiments, and simulation models. In this paper, the existing research achievements have been reviewed, and problems to be solved have been proposed. The monitoring of lightning incidents on wind farms remains a challenge, and a device to capture lightning strikes to wind turbines with high efficiency is in demand. The impact of sensors on the blade on the lightning protection system cannot be ignored and needs further investigation. For the simulation model, the influence of space charge on the lightning attachment process is not fully understood, and improvements might be made to the existing model.
- Open Access
Numerical Analysis of Transient Performance of Grounding Grid with Lightning Rod Installed on Multi-Grounded Frame
In large substations, many lightning rods are installed on multi-grounded frames. The lightning rods, the frame, the grounding grid and the soil form a whole body, and the lightning current will be discharged from many grounding points. In this paper, based on the partial element equivalent circuit method, a numerical model, in the time domain, is developed to simulate the lightning-caused electromagnetic transients on the frame and the grounding grid. The model is verified by field testing and by comparison with commercial software. The model has several features: (1) it has a simple time domain form; (2) it is stable due to a staggered arrangement of space and time variables and an implicit difference scheme used, and (3) the dimension of the equations is relatively small because the unknown variables are divided into several groups, which are calculated one by one. With this method, the transient characteristics of the grounding grid with lightning rods on the frame are calculated, and the factors affecting the results are analyzed. It can be seen that although the frame causes the ground potential rise in an evenly distributed manner, compared with the situation in which the lightning strikes an independent lightning rod, the ground potential decrease rate near the main grounding point is almost the same because most of the current still enters the soil from the grounding electrode closest to the lightning strike. Therefore, even if there is a frame, the nearby facilities should take the same protective measures as in the case of an independent lightning rod. The ground conductors near the grounding points of the frame should be dense enough to reduce the potential gradient. The equipment should be kept at least 10 m away from the grounding point for lightning.
Open AccessNumerical Analysis of Transient Performance of Grounding Grid with Lightning Rod Installed on Multi-Grounded Frame
In large substations, many lightning rods are installed on multi-grounded frames. The lightning rods, the frame, the grounding grid and the soil form a whole body, and the lightning current will be discharged from many grounding points. In this paper, based on the partial element equivalent circuit method, a numerical model, in the time domain, is developed to simulate the lightning-caused electromagnetic transients on the frame and the grounding grid. The model is verified by field testing and by comparison with commercial software. The model has several features: (1) it has a simple time domain form; (2) it is stable due to a staggered arrangement of space and time variables and an implicit difference scheme used, and (3) the dimension of the equations is relatively small because the unknown variables are divided into several groups, which are calculated one by one. With this method, the transient characteristics of the grounding grid with lightning rods on the frame are calculated, and the factors affecting the results are analyzed. It can be seen that although the frame causes the ground potential rise in an evenly distributed manner, compared with the situation in which the lightning strikes an independent lightning rod, the ground potential decrease rate near the main grounding point is almost the same because most of the current still enters the soil from the grounding electrode closest to the lightning strike. Therefore, even if there is a frame, the nearby facilities should take the same protective measures as in the case of an independent lightning rod. The ground conductors near the grounding points of the frame should be dense enough to reduce the potential gradient. The equipment should be kept at least 10 m away from the grounding point for lightning.