Sabine Zips
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sabine Zips has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Bernhard Wolfrum
Technical University of Munich
2 shared publications - Andreas Offenhäusser
Forschungszentrum Jülich
1 shared publication - Christian Pfeffer
EI, TUM, 9184 Munchen, Germany, 80333
1 shared publication - Dirk Mayer
Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428, Jülich, Germany
1 shared publication - Ernst Muellner
Texas Instruments Deutschland GmbH, 85356 Freising, Germany
1 shared publication - Franz Kreupl
Department of Electrical and Computer Engineering, Technical University of Munich, 80333 Munich, Germany
1 shared publication
Latest Publications
- Open Access
Inkjet-Printed and Electroplated 3D Electrodes for Recording Extracellular Signals in Cell Culture
Recent investigations into cardiac or nervous tissues call for systems that are able to electrically record in 3D as opposed to 2D. Typically, challenging microfabrication steps are required to produce 3D microelectrode arrays capable of recording at the desired position within the tissue of interest. As an alternative, additive manufacturing is becoming a versatile platform for rapidly prototyping novel sensors with flexible geometric design. In this work, 3D MEAs for cell-culture applications were fabricated using a piezoelectric inkjet printer. The aspect ratio and height of the printed 3D electrodes were user-defined by adjusting the number of deposited droplets of silver nanoparticle ink along with a continuous printing method and an appropriate drop-to-drop delay. The Ag 3D MEAs were later electroplated with Au and Pt in order to reduce leakage of potentially cytotoxic silver ions into the cellular medium. The functionality of the array was confirmed using impedance spectroscopy, cyclic voltammetry, and recordings of extracellular potentials from cardiomyocyte-like HL-1 cells.
Open AccessInkjet-Printed and Electroplated 3D Electrodes for Recording Extracellular Signals in Cell Culture
Recent investigations into cardiac or nervous tissues call for systems that are able to electrically record in 3D as opposed to 2D. Typically, challenging microfabrication steps are required to produce 3D microelectrode arrays capable of recording at the desired position within the tissue of interest. As an alternative, additive manufacturing is becoming a versatile platform for rapidly prototyping novel sensors with flexible geometric design. In this work, 3D MEAs for cell-culture applications were fabricated using a piezoelectric inkjet printer. The aspect ratio and height of the printed 3D electrodes were user-defined by adjusting the number of deposited droplets of silver nanoparticle ink along with a continuous printing method and an appropriate drop-to-drop delay. The Ag 3D MEAs were later electroplated with Au and Pt in order to reduce leakage of potentially cytotoxic silver ions into the cellular medium. The functionality of the array was confirmed using impedance spectroscopy, cyclic voltammetry, and recordings of extracellular potentials from cardiomyocyte-like HL-1 cells.
- 26 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 5 (6) , 1-4
A Cost-Effective, Impediometric Na+-Sensor in Fluids
A crucial parameter in body-fluid analysis are Na+-ions. Preferably realized as a small wearable, mostly the fabrication method, size and the costs prevented ion-selective devices to enter the big realm of IoT applications. This paper reports a printed, electrochemical sensor system for measuring Na+ ions in liquids. We designed, simulated, optimized, fabricated and experimentally evaluated the sensor structures. Employing electrochemical impedance spectroscopy on a printable, dielectric Ion-Selective-Membrane, reproducible 2-electrode-measurement results are achieved in a biological relevant, mM-range. The cross sensitivity towards K+-ions, dynamic range and drift are investigated, and a robust measurement scheme is derived. The flexible, low-cost approach can enable new IoT and Point-of-care applications in biomedicine like sweat analysis- as well as environmental monitoring.
- 26 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 5 (6) , 1-4
A Cost-Effective, Impediometric Na+-Sensor in Fluids
A crucial parameter in body-fluid analysis are Na+-ions. Preferably realized as a small wearable, mostly the fabrication method, size and the costs prevented ion-selective devices to enter the big realm of IoT applications. This paper reports a printed, electrochemical sensor system for measuring Na+ ions in liquids. We designed, simulated, optimized, fabricated and experimentally evaluated the sensor structures. Employing electrochemical impedance spectroscopy on a printable, dielectric Ion-Selective-Membrane, reproducible 2-electrode-measurement results are achieved in a biological relevant, mM-range. The cross sensitivity towards K+-ions, dynamic range and drift are investigated, and a robust measurement scheme is derived. The flexible, low-cost approach can enable new IoT and Point-of-care applications in biomedicine like sweat analysis- as well as environmental monitoring.