Gang Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gang Ma has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Guangnu Fu
State Grid Zhejiang Longgang Electric Power Supply Corporation, Longgang 325802, China
1 shared publication Guchao Xu
School of Electrical and Automation Engineering Nanjing Normal University No. 78 Bancang Street, Xuanwu District Nanjing People's Republic of China
1 shared publication- Jun He
College of Electrical Engineering of Shanghai University of Electric Power, Yangpu District, Shanghai 200090, China
1 shared publication - Qian Liu
School of Electrical & Automation Engineering, Nanjing Normal University, Nanjing 210023, China
1 shared publication Rong Ju
School of Electrical and Automation Engineering Nanjing Normal University No. 78 Bancang Street, Xuanwu District Nanjing People's Republic of China
1 shared publication- Weikang Li
School of Electrical & Automation Engineering, Nanjing Normal University, Nanjing 210023, China
1 shared publication
Latest Publications
- Open Access
Research on Packet Control Strategy of Constant-Frequency Air-Conditioning Demand Response Based on Improved Particle Swarm Optimization Algorithm
To better utilize air-conditioning load in terms of demand side response potential and improve precision and speed, a control strategy of traditional temperature-control air conditioning, determining frequency load as the research object, and air conditioning determined with a frequency theory model and the Monte Carlo method, were used to construct a power aggregation model. This was combined with user feedback to study thermal comfort as a lateral load demand response resource to determine the potential demand response of power systems. Based on the state-queuing model, an air-conditioning load grouping control strategy using an improved particle swarm optimization algorithm is proposed which can accurately control the air-conditioning load following the reference load.
Open AccessResearch on Packet Control Strategy of Constant-Frequency Air-Conditioning Demand Response Based on Improved Particle Swarm Optimization Algorithm
To better utilize air-conditioning load in terms of demand side response potential and improve precision and speed, a control strategy of traditional temperature-control air conditioning, determining frequency load as the research object, and air conditioning determined with a frequency theory model and the Monte Carlo method, were used to construct a power aggregation model. This was combined with user feedback to study thermal comfort as a lateral load demand response resource to determine the potential demand response of power systems. Based on the state-queuing model, an air-conditioning load grouping control strategy using an improved particle swarm optimization algorithm is proposed which can accurately control the air-conditioning load following the reference load.
- Open Access
A New MMC Sub-Module Topology with DC Fault Blocking Capability and Capacitor Voltage Self-Balancing Capability
A large number of modular multilevel converters (MMC) are connected to HVDC transmission systems nowadays. This paper aims at the short-circuit fault in the DC line of the HVDC transmission system and the problem of capacitor voltage imbalance in MMC, proposing a new type of MMC sub-module, which has both the DC fault self-clearing ability and the capacitor voltage self-balancing ability. This sub-module combines the topology of half bridge and full bridge. It uses the reverse capacitor voltage to forcibly turn off the conducting diode to block the fault current loop. At the same time, the two capacitances charge and discharge states are consistent by utilizing the operating mode of the sub-module. It is possible to directly achieve a self-balancing capacitor voltage without complex balancing voltage control. The MATLAB/Simulink simulation verifies the effectiveness of the DC fault blocking capability and capacitor voltage balance capability of the proposed sub-module.
Open AccessA New MMC Sub-Module Topology with DC Fault Blocking Capability and Capacitor Voltage Self-Balancing Capability
A large number of modular multilevel converters (MMC) are connected to HVDC transmission systems nowadays. This paper aims at the short-circuit fault in the DC line of the HVDC transmission system and the problem of capacitor voltage imbalance in MMC, proposing a new type of MMC sub-module, which has both the DC fault self-clearing ability and the capacitor voltage self-balancing ability. This sub-module combines the topology of half bridge and full bridge. It uses the reverse capacitor voltage to forcibly turn off the conducting diode to block the fault current loop. At the same time, the two capacitances charge and discharge states are consistent by utilizing the operating mode of the sub-module. It is possible to directly achieve a self-balancing capacitor voltage without complex balancing voltage control. The MATLAB/Simulink simulation verifies the effectiveness of the DC fault blocking capability and capacitor voltage balance capability of the proposed sub-module.
- Open Access
- 17 October 2016
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 11 (1) , 194-202
Multi‐objective optimal configuration method for a standalone wind–solar–battery hybrid power system
With the development of the energy internet, the standalone wind–solar–battery hybrid power system has gradually become an effective means for the complete utilisation of clean energy for power generation. The allocation of the various types of power sources for ensuring a reliable power supply and for improving the economic efficiency of a system is a crucial issue in the system planning and design stages. The models of the power load and the power sources, containing random components, are first established in this study, based on which the power supply reliability and constraint conditions for the equipment quantities are considered for establishing various evaluation indexes for improving the system performance. Then, according to the combinations of the natural selection particle swarm optimisation algorithm and the weight coefficient transform method, a multi‐objective optimisation algorithm is proposed for optimising the configuration of a standalone wind–solar–battery hybrid power system. Finally, it is demonstrated by an example that the optimisation method not only meets the requirements of the multi‐objective optimisation system but is also significant in reducing energy wastes and fluctuations, cost saving, and in ensuring the reliability of the power supply.
- 17 October 2016
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 11 (1) , 194-202
Open AccessMulti‐objective optimal configuration method for a standalone wind–solar–battery hybrid power system
With the development of the energy internet, the standalone wind–solar–battery hybrid power system has gradually become an effective means for the complete utilisation of clean energy for power generation. The allocation of the various types of power sources for ensuring a reliable power supply and for improving the economic efficiency of a system is a crucial issue in the system planning and design stages. The models of the power load and the power sources, containing random components, are first established in this study, based on which the power supply reliability and constraint conditions for the equipment quantities are considered for establishing various evaluation indexes for improving the system performance. Then, according to the combinations of the natural selection particle swarm optimisation algorithm and the weight coefficient transform method, a multi‐objective optimisation algorithm is proposed for optimising the configuration of a standalone wind–solar–battery hybrid power system. Finally, it is demonstrated by an example that the optimisation method not only meets the requirements of the multi‐objective optimisation system but is also significant in reducing energy wastes and fluctuations, cost saving, and in ensuring the reliability of the power supply.